mirror of
https://github.com/torvalds/linux.git
synced 2024-11-01 09:41:44 +00:00
mac80211: mesh_plink: don't ignore holding timer
The ignore_plink_timer flag is set when doing mod_timer() if the timer was not previously active. This is to avoid executing the timeout if del_timer() was subsequently called. However, del_timer() only happens if we are moving to ESTAB state or get a close frame while in HOLDING. We cannot leave HOLDING and re-enter ESTAB unless we receive a close frame (in which case ignore_plink_timer is already set) or if the timeout expires, so there actually isn't a case where this is needed on mod_timer(). Signed-off-by: Bob Copeland <bob@cozybit.com> Signed-off-by: Johannes Berg <johannes.berg@intel.com>
This commit is contained in:
parent
58506eba78
commit
272a9e2614
@ -671,8 +671,7 @@ static void mesh_plink_close(struct ieee80211_sub_if_data *sdata,
|
||||
|
||||
sta->reason = reason;
|
||||
sta->plink_state = NL80211_PLINK_HOLDING;
|
||||
if (!mod_plink_timer(sta, mshcfg->dot11MeshHoldingTimeout))
|
||||
sta->ignore_plink_timer = true;
|
||||
mod_plink_timer(sta, mshcfg->dot11MeshHoldingTimeout);
|
||||
}
|
||||
|
||||
static u32 mesh_plink_establish(struct ieee80211_sub_if_data *sdata,
|
||||
|
Loading…
Reference in New Issue
Block a user