mirror of
https://github.com/torvalds/linux.git
synced 2024-11-26 22:21:42 +00:00
power: bq25890: fix ADC mode configuration
Datasheet describes two modes for reading ADC measurements: 1. continuous, 1 Hz - enabled and started by CONV_RATE bit 2. one-shot - triggered by CONV_START bit In continuous mode, CONV_START is read-only and signifies an ongoing conversion. Change the code to follow the datasheet and really disable continuous mode for power saving. Signed-off-by: Michał Mirosław <mirq-linux@rere.qmqm.pl> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
This commit is contained in:
parent
1e4724d0b7
commit
21d90eda43
@ -126,6 +126,7 @@ static const struct regmap_access_table bq25890_writeable_regs = {
|
||||
|
||||
static const struct regmap_range bq25890_volatile_reg_ranges[] = {
|
||||
regmap_reg_range(0x00, 0x00),
|
||||
regmap_reg_range(0x02, 0x02),
|
||||
regmap_reg_range(0x09, 0x09),
|
||||
regmap_reg_range(0x0b, 0x14),
|
||||
};
|
||||
@ -374,18 +375,38 @@ enum bq25890_chrg_fault {
|
||||
CHRG_FAULT_TIMER_EXPIRED,
|
||||
};
|
||||
|
||||
static bool bq25890_is_adc_property(enum power_supply_property psp)
|
||||
{
|
||||
switch (psp) {
|
||||
case POWER_SUPPLY_PROP_VOLTAGE_NOW:
|
||||
case POWER_SUPPLY_PROP_CURRENT_NOW:
|
||||
return true;
|
||||
|
||||
default:
|
||||
return false;
|
||||
}
|
||||
}
|
||||
|
||||
static int bq25890_power_supply_get_property(struct power_supply *psy,
|
||||
enum power_supply_property psp,
|
||||
union power_supply_propval *val)
|
||||
{
|
||||
int ret;
|
||||
struct bq25890_device *bq = power_supply_get_drvdata(psy);
|
||||
struct bq25890_state state;
|
||||
bool do_adc_conv;
|
||||
int ret;
|
||||
|
||||
mutex_lock(&bq->lock);
|
||||
state = bq->state;
|
||||
do_adc_conv = !state.online && bq25890_is_adc_property(psp);
|
||||
if (do_adc_conv)
|
||||
bq25890_field_write(bq, F_CONV_START, 1);
|
||||
mutex_unlock(&bq->lock);
|
||||
|
||||
if (do_adc_conv)
|
||||
regmap_field_read_poll_timeout(bq->rmap_fields[F_CONV_START],
|
||||
ret, !ret, 25000, 1000000);
|
||||
|
||||
switch (psp) {
|
||||
case POWER_SUPPLY_PROP_STATUS:
|
||||
if (!state.online)
|
||||
@ -623,8 +644,8 @@ static int bq25890_hw_init(struct bq25890_device *bq)
|
||||
}
|
||||
}
|
||||
|
||||
/* Configure ADC for continuous conversions. This does not enable it. */
|
||||
ret = bq25890_field_write(bq, F_CONV_RATE, 1);
|
||||
/* Configure ADC for continuous conversions when charging */
|
||||
ret = bq25890_field_write(bq, F_CONV_RATE, !!bq->state.online);
|
||||
if (ret < 0) {
|
||||
dev_dbg(bq->dev, "Config ADC failed %d\n", ret);
|
||||
return ret;
|
||||
@ -966,7 +987,7 @@ static int bq25890_suspend(struct device *dev)
|
||||
* If charger is removed, while in suspend, make sure ADC is diabled
|
||||
* since it consumes slightly more power.
|
||||
*/
|
||||
return bq25890_field_write(bq, F_CONV_START, 0);
|
||||
return bq25890_field_write(bq, F_CONV_RATE, 0);
|
||||
}
|
||||
|
||||
static int bq25890_resume(struct device *dev)
|
||||
@ -982,7 +1003,7 @@ static int bq25890_resume(struct device *dev)
|
||||
|
||||
/* Re-enable ADC only if charger is plugged in. */
|
||||
if (bq->state.online) {
|
||||
ret = bq25890_field_write(bq, F_CONV_START, 1);
|
||||
ret = bq25890_field_write(bq, F_CONV_RATE, 1);
|
||||
if (ret < 0)
|
||||
goto unlock;
|
||||
}
|
||||
|
Loading…
Reference in New Issue
Block a user