power: bq25890: use proper CURRENT_NOW property for I_BAT

Charge Current is more apropriately reflected by CURRENT_NOW property
(measured current) than CONSTANT_CURRENT_VOLTAGE (configured CC-phase
current limit). Fix the reference and make the sign reflect direction
of the current.

Signed-off-by: Michał Mirosław <mirq-linux@rere.qmqm.pl>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
This commit is contained in:
Michał Mirosław 2020-05-04 21:47:30 +02:00 committed by Sebastian Reichel
parent 0383024f81
commit 1e4724d0b7

View File

@ -427,15 +427,6 @@ static int bq25890_power_supply_get_property(struct power_supply *psy,
val->intval = POWER_SUPPLY_HEALTH_UNSPEC_FAILURE;
break;
case POWER_SUPPLY_PROP_CONSTANT_CHARGE_CURRENT:
ret = bq25890_field_read(bq, F_ICHGR); /* read measured value */
if (ret < 0)
return ret;
/* converted_val = ADC_val * 50mA (table 10.3.19) */
val->intval = ret * 50000;
break;
case POWER_SUPPLY_PROP_CONSTANT_CHARGE_CURRENT_MAX:
val->intval = bq25890_find_val(bq->init_data.ichg, TBL_ICHG);
break;
@ -471,6 +462,15 @@ static int bq25890_power_supply_get_property(struct power_supply *psy,
val->intval = 2304000 + ret * 20000;
break;
case POWER_SUPPLY_PROP_CURRENT_NOW:
ret = bq25890_field_read(bq, F_ICHGR); /* read measured value */
if (ret < 0)
return ret;
/* converted_val = ADC_val * 50mA (table 10.3.19) */
val->intval = ret * -50000;
break;
default:
return -EINVAL;
}
@ -645,12 +645,12 @@ static const enum power_supply_property bq25890_power_supply_props[] = {
POWER_SUPPLY_PROP_STATUS,
POWER_SUPPLY_PROP_ONLINE,
POWER_SUPPLY_PROP_HEALTH,
POWER_SUPPLY_PROP_CONSTANT_CHARGE_CURRENT,
POWER_SUPPLY_PROP_CONSTANT_CHARGE_CURRENT_MAX,
POWER_SUPPLY_PROP_CONSTANT_CHARGE_VOLTAGE,
POWER_SUPPLY_PROP_CONSTANT_CHARGE_VOLTAGE_MAX,
POWER_SUPPLY_PROP_CHARGE_TERM_CURRENT,
POWER_SUPPLY_PROP_VOLTAGE_NOW,
POWER_SUPPLY_PROP_CURRENT_NOW,
};
static char *bq25890_charger_supplied_to[] = {