clk: exynos5433: Fix CLK_PCLK_MONOTONIC_CNT clk register assignment

CLK_PCLK_MONOTONIC_CNT clock had a wrong register assigned to it.
The correct register is ENABLE_PCLK_MIF_SECURE_MONOTONIC_CNT.

Signed-off-by: Jonghwa Lee <jonghwa3.lee@samsung.com>
Signed-off-by: Chanwoo Choi <cw00.choi@samsung.com>
Reviewed-by: Krzysztof Kozlowski <k.kozlowski.k@gmail.com>
Signed-off-by: Sylwester Nawrocki <s.nawrocki@samsung.com>
This commit is contained in:
Jonghwa Lee 2015-04-27 20:36:30 +09:00 committed by Sylwester Nawrocki
parent a84d1f546c
commit 1a9f6c887d

View File

@ -1490,7 +1490,7 @@ static struct samsung_gate_clock mif_gate_clks[] __initdata = {
/* ENABLE_PCLK_MIF_SECURE_MONOTONIC_CNT */
GATE(CLK_PCLK_MONOTONIC_CNT, "pclk_monotonic_cnt", "div_aclk_mif_133",
ENABLE_PCLK_MIF_SECURE_RTC, 0, 0, 0),
ENABLE_PCLK_MIF_SECURE_MONOTONIC_CNT, 0, 0, 0),
/* ENABLE_PCLK_MIF_SECURE_RTC */
GATE(CLK_PCLK_RTC, "pclk_rtc", "div_aclk_mif_133",