scsi: smartpqi_init: fix boolean expression in pqi_device_remove_start

Fix boolean expression by using logical AND operator '&&' instead of
bitwise operator '&'.

This issue was detected with the help of Coccinelle.

Fixes: 1e46731efd ("scsi: smartpqi: check for null device pointers")
Signed-off-by: Gustavo A. R. Silva <gustavo@embeddedor.com>
Signed-off-by: Gustavo A. R. Silva <gustavo@embeddedor.com>
Acked-by: Don Brace <don.brace@microsemi.com>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
This commit is contained in:
Gustavo A. R. Silva 2019-01-03 10:47:44 -06:00 committed by Martin K. Petersen
parent 3f7e62bba0
commit 12de280b36

View File

@ -323,7 +323,7 @@ static inline void pqi_device_remove_start(struct pqi_scsi_dev *device)
static inline bool pqi_device_in_remove(struct pqi_ctrl_info *ctrl_info,
struct pqi_scsi_dev *device)
{
return device->in_remove & !ctrl_info->in_shutdown;
return device->in_remove && !ctrl_info->in_shutdown;
}