mirror of
https://github.com/torvalds/linux.git
synced 2024-11-24 05:02:12 +00:00
hwmon: (f75375s) Fix automatic pwm mode setting for F75373 & F75375
In order to enable temperature mode aka automatic mode for the F75373 and F75375 chips, the two FANx_MODE bits in the fan configuration register need be set to 01, not 10. Signed-off-by: Nikolaus Schulz <mail@microschulz.de> Cc: stable@kernel.org # 2.6.32+ Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
This commit is contained in:
parent
eb564e1dbc
commit
09e87e5c4f
@ -369,7 +369,7 @@ static int set_pwm_enable_direct(struct i2c_client *client, int nr, int val)
|
||||
fanmode |= (3 << FAN_CTRL_MODE(nr));
|
||||
break;
|
||||
case 2: /* AUTOMATIC*/
|
||||
fanmode |= (2 << FAN_CTRL_MODE(nr));
|
||||
fanmode |= (1 << FAN_CTRL_MODE(nr));
|
||||
break;
|
||||
case 3: /* fan speed */
|
||||
break;
|
||||
|
Loading…
Reference in New Issue
Block a user