RDMA/hns: Update CQE specifications

According to hip08 UM, the maximum number of CQEs supported by each CQ is
4M.

Signed-off-by: Lijun Ou <oulijun@huawei.com>
Signed-off-by: Jason Gunthorpe <jgg@mellanox.com>
This commit is contained in:
Lijun Ou 2019-05-24 15:31:21 +08:00 committed by Jason Gunthorpe
parent 8ffb813255
commit 0502849d0b

View File

@ -54,7 +54,7 @@
#define HNS_ROCE_V2_MAX_CQ_NUM 0x100000
#define HNS_ROCE_V2_MAX_CQC_TIMER_NUM 0x100
#define HNS_ROCE_V2_MAX_SRQ_NUM 0x100000
#define HNS_ROCE_V2_MAX_CQE_NUM 0x10000
#define HNS_ROCE_V2_MAX_CQE_NUM 0x400000
#define HNS_ROCE_V2_MAX_SRQWQE_NUM 0x8000
#define HNS_ROCE_V2_MAX_RQ_SGE_NUM 0x100
#define HNS_ROCE_V2_MAX_SQ_SGE_NUM 0xff