linux/Documentation/hwmon/tps53679.rst

188 lines
3.7 KiB
ReStructuredText
Raw Normal View History

Kernel driver tps53679
======================
Supported chips:
* Texas Instruments TPS53647
Prefix: 'tps53647'
Addresses scanned: -
Datasheet: https://www.ti.com/lit/gpn/tps53647
* Texas Instruments TPS53667
Prefix: 'tps53667'
Addresses scanned: -
Datasheet: https://www.ti.com/lit/gpn/TPS53667
* Texas Instruments TPS53676
Prefix: 'tps53676'
Addresses scanned: -
Datasheet: https://www.ti.com/lit/gpn/TPS53676
* Texas Instruments TPS53679
Prefix: 'tps53679'
Addresses scanned: -
Datasheet: https://www.ti.com/lit/gpn/TPS53679 (short version)
* Texas Instruments TPS53681
Prefix: 'tps53681'
Addresses scanned: -
Datasheet: https://www.ti.com/lit/gpn/TPS53681
* Texas Instruments TPS53688
Prefix: 'tps53688'
Addresses scanned: -
Datasheet: Available under NDA
Authors:
Vadim Pasternak <vadimp@mellanox.com>
Guenter Roeck <linux@roeck-us.net>
Description
-----------
Chips in this series are multi-phase step-down converters with one or two
output channels and up to 8 phases per channel.
Usage Notes
-----------
This driver does not probe for PMBus devices. You will have to instantiate
devices explicitly.
Example: the following commands will load the driver for an TPS53681 at address
0x60 on I2C bus #1::
# modprobe tps53679
# echo tps53681 0x60 > /sys/bus/i2c/devices/i2c-1/new_device
Sysfs attributes
----------------
======================= ========================================================
in1_label "vin"
in1_input Measured input voltage.
in1_lcrit Critical minimum input voltage
TPS53679, TPS53681, TPS53688 only.
in1_lcrit_alarm Input voltage critical low alarm.
TPS53679, TPS53681, TPS53688 only.
in1_crit Critical maximum input voltage.
in1_crit_alarm Input voltage critical high alarm.
in[N]_label "vout[1-2]"
- TPS53647, TPS53667: N=2
- TPS53679, TPS53588: N=2,3
in[N]_input Measured output voltage.
in[N]_lcrit Critical minimum input voltage.
TPS53679, TPS53681, TPS53688 only.
in[N]_lcrit_alarm Critical minimum voltage alarm.
TPS53679, TPS53681, TPS53688 only.
in[N]_alarm Output voltage alarm.
TPS53647, TPS53667 only.
in[N]_crit Critical maximum output voltage.
TPS53679, TPS53681, TPS53688 only.
in[N]_crit_alarm Output voltage critical high alarm.
TPS53679, TPS53681, TPS53688 only.
temp[N]_input Measured temperature.
- TPS53647, TPS53667: N=1
- TPS53679, TPS53681, TPS53588: N=1,2
temp[N]_max Maximum temperature.
temp[N]_crit Critical high temperature.
temp[N]_max_alarm Temperature high alarm.
temp[N]_crit_alarm Temperature critical high alarm.
power1_label "pin".
power1_input Measured input power.
power[N]_label "pout[1-2]".
- TPS53647, TPS53667: N=2
- TPS53676, TPS53679, TPS53681, TPS53588: N=2,3
power[N]_input Measured output power.
curr1_label "iin".
curr1_input Measured input current.
curr1_max Maximum input current.
curr1_max_alarm Input current high alarm.
curr1_crit Critical input current.
curr1_crit_alarm Input current critical alarm.
curr[N]_label "iout[1-2]" or "iout1.[0-5]".
The first digit is the output channel, the second
digit is the phase within the channel. Per-phase
telemetry supported on TPS53676 and TPS53681 only.
- TPS53647, TPS53667: N=2
- TPS53679, TPS53588: N=2,3
- TPS53676: N=2-8
- TPS53681: N=2-9
curr[N]_input Measured output current.
curr[N]_max Maximum output current.
curr[N]_crit Critical high output current.
curr[N]_max_alarm Output current high alarm.
curr[N]_crit_alarm Output current critical high alarm.
Limit and alarm attributes are only available for
non-phase telemetry (iout1, iout2).
======================= ========================================================