2014-05-08 20:49:05 +00:00
|
|
|
* Samsung S3C2410 Clock Controller
|
|
|
|
|
|
|
|
The S3C2410 clock controller generates and supplies clock to various controllers
|
|
|
|
within the SoC. The clock binding described here is applicable to the s3c2410,
|
|
|
|
s3c2440 and s3c2442 SoCs in the s3c24x family.
|
|
|
|
|
|
|
|
Required Properties:
|
|
|
|
|
|
|
|
- compatible: should be one of the following.
|
|
|
|
- "samsung,s3c2410-clock" - controller compatible with S3C2410 SoC.
|
|
|
|
- "samsung,s3c2440-clock" - controller compatible with S3C2440 SoC.
|
|
|
|
- "samsung,s3c2442-clock" - controller compatible with S3C2442 SoC.
|
|
|
|
- reg: physical base address of the controller and length of memory mapped
|
|
|
|
region.
|
|
|
|
- #clock-cells: should be 1.
|
|
|
|
|
|
|
|
Each clock is assigned an identifier and client nodes can use this identifier
|
|
|
|
to specify the clock which they consume. Some of the clocks are available only
|
|
|
|
on a particular SoC.
|
|
|
|
|
|
|
|
All available clocks are defined as preprocessor macros in
|
2014-05-14 15:03:20 +00:00
|
|
|
dt-bindings/clock/s3c2410.h header and can be used in device
|
2014-05-08 20:49:05 +00:00
|
|
|
tree sources.
|
|
|
|
|
|
|
|
External clocks:
|
|
|
|
|
|
|
|
The xti clock used as input for the plls is generated outside the SoC. It is
|
|
|
|
expected that is are defined using standard clock bindings with a
|
|
|
|
clock-output-names value of "xti".
|
|
|
|
|
|
|
|
Example: Clock controller node:
|
|
|
|
|
|
|
|
clocks: clock-controller@4c000000 {
|
|
|
|
compatible = "samsung,s3c2410-clock";
|
|
|
|
reg = <0x4c000000 0x20>;
|
|
|
|
#clock-cells = <1>;
|
|
|
|
};
|
|
|
|
|
|
|
|
Example: UART controller node that consumes the clock generated by the clock
|
|
|
|
controller (refer to the standard clock bindings for information about
|
|
|
|
"clocks" and "clock-names" properties):
|
|
|
|
|
|
|
|
serial@50004000 {
|
|
|
|
compatible = "samsung,s3c2440-uart";
|
|
|
|
reg = <0x50004000 0x4000>;
|
|
|
|
interrupts = <1 23 3 4>, <1 23 4 4>;
|
|
|
|
clock-names = "uart", "clk_uart_baud2";
|
|
|
|
clocks = <&clocks PCLK_UART0>, <&clocks PCLK_UART0>;
|
|
|
|
status = "disabled";
|
|
|
|
};
|