2019-05-27 06:55:01 +00:00
|
|
|
// SPDX-License-Identifier: GPL-2.0-or-later
|
2017-02-03 18:20:20 +00:00
|
|
|
/*
|
|
|
|
* Handling of a single switch chip, part of a switch fabric
|
|
|
|
*
|
2017-03-28 19:10:36 +00:00
|
|
|
* Copyright (c) 2017 Savoir-faire Linux Inc.
|
|
|
|
* Vivien Didelot <vivien.didelot@savoirfairelinux.com>
|
2017-02-03 18:20:20 +00:00
|
|
|
*/
|
|
|
|
|
net: dsa: Unset vlan_filtering when ports leave the bridge
When ports are standalone (after they left the bridge), they should have
no VLAN filtering semantics (they should pass all traffic to the CPU).
Currently this is not true for switchdev drivers, because the bridge
"forgets" to unset that.
Normally one would think that doing this at the bridge layer would be a
better idea, i.e. call br_vlan_filter_toggle() from br_del_if(), similar
to how nbp_vlan_init() is called from br_add_if().
However what complicates that approach, and makes this one preferable,
is the fact that for the bridge core, vlan_filtering is a per-bridge
setting, whereas for switchdev/DSA it is per-port. Also there are
switches where the setting is per the entire device, and unsetting
vlan_filtering one by one, for each leaving port, would not be possible
from the bridge core without a certain level of awareness. So do this in
DSA and let drivers be unaware of it.
Signed-off-by: Vladimir Oltean <olteanv@gmail.com>
Reviewed-by: Andrew Lunn <andrew@lunn.ch>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2019-04-28 18:45:46 +00:00
|
|
|
#include <linux/if_bridge.h>
|
2017-02-03 18:20:20 +00:00
|
|
|
#include <linux/netdevice.h>
|
|
|
|
#include <linux/notifier.h>
|
2019-02-20 22:35:39 +00:00
|
|
|
#include <linux/if_vlan.h>
|
2017-05-19 21:00:52 +00:00
|
|
|
#include <net/switchdev.h>
|
2017-05-17 19:46:03 +00:00
|
|
|
|
|
|
|
#include "dsa_priv.h"
|
2017-02-03 18:20:20 +00:00
|
|
|
|
2017-05-19 21:00:52 +00:00
|
|
|
static unsigned int dsa_switch_fastest_ageing_time(struct dsa_switch *ds,
|
|
|
|
unsigned int ageing_time)
|
|
|
|
{
|
2021-10-20 17:49:50 +00:00
|
|
|
struct dsa_port *dp;
|
2017-05-19 21:00:52 +00:00
|
|
|
|
2021-10-20 17:49:50 +00:00
|
|
|
dsa_switch_for_each_port(dp, ds)
|
2017-05-19 21:00:52 +00:00
|
|
|
if (dp->ageing_time && dp->ageing_time < ageing_time)
|
|
|
|
ageing_time = dp->ageing_time;
|
|
|
|
|
|
|
|
return ageing_time;
|
|
|
|
}
|
|
|
|
|
|
|
|
static int dsa_switch_ageing_time(struct dsa_switch *ds,
|
|
|
|
struct dsa_notifier_ageing_time_info *info)
|
|
|
|
{
|
|
|
|
unsigned int ageing_time = info->ageing_time;
|
2021-01-09 00:01:51 +00:00
|
|
|
|
|
|
|
if (ds->ageing_time_min && ageing_time < ds->ageing_time_min)
|
|
|
|
return -ERANGE;
|
|
|
|
|
|
|
|
if (ds->ageing_time_max && ageing_time > ds->ageing_time_max)
|
|
|
|
return -ERANGE;
|
2017-05-19 21:00:52 +00:00
|
|
|
|
|
|
|
/* Program the fastest ageing time in case of multiple bridges */
|
|
|
|
ageing_time = dsa_switch_fastest_ageing_time(ds, ageing_time);
|
|
|
|
|
|
|
|
if (ds->ops->set_ageing_time)
|
|
|
|
return ds->ops->set_ageing_time(ds, ageing_time);
|
|
|
|
|
|
|
|
return 0;
|
|
|
|
}
|
|
|
|
|
2021-10-20 17:49:53 +00:00
|
|
|
static bool dsa_port_mtu_match(struct dsa_port *dp,
|
|
|
|
struct dsa_notifier_mtu_info *info)
|
net: dsa: configure the MTU for switch ports
It is useful be able to configure port policers on a switch to accept
frames of various sizes:
- Increase the MTU for better throughput from the default of 1500 if it
is known that there is no 10/100 Mbps device in the network.
- Decrease the MTU to limit the latency of high-priority frames under
congestion, or work around various network segments that add extra
headers to packets which can't be fragmented.
For DSA slave ports, this is mostly a pass-through callback, called
through the regular ndo ops and at probe time (to ensure consistency
across all supported switches).
The CPU port is called with an MTU equal to the largest configured MTU
of the slave ports. The assumption is that the user might want to
sustain a bidirectional conversation with a partner over any switch
port.
The DSA master is configured the same as the CPU port, plus the tagger
overhead. Since the MTU is by definition L2 payload (sans Ethernet
header), it is up to each individual driver to figure out if it needs to
do anything special for its frame tags on the CPU port (it shouldn't
except in special cases). So the MTU does not contain the tagger
overhead on the CPU port.
However the MTU of the DSA master, minus the tagger overhead, is used as
a proxy for the MTU of the CPU port, which does not have a net device.
This is to avoid uselessly calling the .change_mtu function on the CPU
port when nothing should change.
So it is safe to assume that the DSA master and the CPU port MTUs are
apart by exactly the tagger's overhead in bytes.
Some changes were made around dsa_master_set_mtu(), function which was
now removed, for 2 reasons:
- dev_set_mtu() already calls dev_validate_mtu(), so it's redundant to
do the same thing in DSA
- __dev_set_mtu() returns 0 if ops->ndo_change_mtu is an absent method
That is to say, there's no need for this function in DSA, we can safely
call dev_set_mtu() directly, take the rtnl lock when necessary, and just
propagate whatever errors get reported (since the user probably wants to
be informed).
Some inspiration (mainly in the MTU DSA notifier) was taken from a
vaguely similar patch from Murali and Florian, who are credited as
co-developers down below.
Co-developed-by: Murali Krishna Policharla <murali.policharla@broadcom.com>
Signed-off-by: Murali Krishna Policharla <murali.policharla@broadcom.com>
Co-developed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2020-03-27 19:55:42 +00:00
|
|
|
{
|
net: dsa: make cross-chip notifiers more efficient for host events
To determine whether a given port should react to the port targeted by
the notifier, dsa_port_host_vlan_match() and dsa_port_host_address_match()
look at the positioning of the switch port currently executing the
notifier relative to the switch port for which the notifier was emitted.
To maintain stylistic compatibility with the other match functions from
switch.c, the host address and host VLAN match functions take the
notifier information about targeted port, switch and tree indices as
argument. However, these functions only use that information to retrieve
the struct dsa_port *targeted_dp, which is an invariant for the outer
loop that calls them. So it makes more sense to calculate the targeted
dp only once, and pass it to them as argument.
But furthermore, the targeted dp is actually known at the time the call
to dsa_port_notify() is made. It is just that we decide to only save the
indices of the port, switch and tree in the notifier structure, just to
retrace our steps and find the dp again using dsa_switch_find() and
dsa_to_port().
But both the above functions are relatively expensive, since they need
to iterate through lists. It appears more straightforward to make all
notifiers just pass the targeted dp inside their info structure, and
have the code that needs the indices to look at info->dp->index instead
of info->port, or info->dp->ds->index instead of info->sw_index, or
info->dp->ds->dst->index instead of info->tree_index.
For the sake of consistency, all cross-chip notifiers are converted to
pass the "dp" directly.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-04-15 15:46:22 +00:00
|
|
|
if (dp == info->dp)
|
net: dsa: targeted MTU notifiers should only match on one port
dsa_slave_change_mtu() calls dsa_port_mtu_change() twice:
- it sends a cross-chip notifier with the MTU of the CPU port which is
used to update the DSA links.
- it sends one targeted MTU notifier which is supposed to only match the
user port on which we are changing the MTU. The "propagate_upstream"
variable is used here to bypass the cross-chip notifier system from
switch.c
But due to a mistake, the second, targeted notifier matches not only on
the user port, but also on the DSA link which is a member of the same
switch, if that exists.
And because the DSA links of the entire dst were programmed in a
previous round to the largest_mtu via a "propagate_upstream == true"
notification, then the dsa_port_mtu_change(propagate_upstream == false)
call that is immediately upcoming will break the MTU on the one DSA link
which is chip-wise local to the dp whose MTU is changing right now.
Example given this daisy chain topology:
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ cpu ] [ user ] [ user ] [ dsa ] [ user ]
[ x ] [ ] [ ] [ x ] [ ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
ip link set sw0p1 mtu 9000
ip link set sw1p1 mtu 9000 # at this stage, sw0p1 and sw1p1 can talk
# to one another using jumbo frames
ip link set sw0p2 mtu 1500 # this programs the sw0p3 DSA link first to
# the largest_mtu of 9000, then reprograms it to
# 1500 with the "propagate_upstream == false"
# notifier, breaking communication between
# sw0p1 and sw1p1
To escape from this situation, make the targeted match really match on a
single port - the user port, and rename the "propagate_upstream"
variable to "targeted_match" to clarify the intention and avoid future
issues.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-06-21 16:42:18 +00:00
|
|
|
return true;
|
net: dsa: configure the MTU for switch ports
It is useful be able to configure port policers on a switch to accept
frames of various sizes:
- Increase the MTU for better throughput from the default of 1500 if it
is known that there is no 10/100 Mbps device in the network.
- Decrease the MTU to limit the latency of high-priority frames under
congestion, or work around various network segments that add extra
headers to packets which can't be fragmented.
For DSA slave ports, this is mostly a pass-through callback, called
through the regular ndo ops and at probe time (to ensure consistency
across all supported switches).
The CPU port is called with an MTU equal to the largest configured MTU
of the slave ports. The assumption is that the user might want to
sustain a bidirectional conversation with a partner over any switch
port.
The DSA master is configured the same as the CPU port, plus the tagger
overhead. Since the MTU is by definition L2 payload (sans Ethernet
header), it is up to each individual driver to figure out if it needs to
do anything special for its frame tags on the CPU port (it shouldn't
except in special cases). So the MTU does not contain the tagger
overhead on the CPU port.
However the MTU of the DSA master, minus the tagger overhead, is used as
a proxy for the MTU of the CPU port, which does not have a net device.
This is to avoid uselessly calling the .change_mtu function on the CPU
port when nothing should change.
So it is safe to assume that the DSA master and the CPU port MTUs are
apart by exactly the tagger's overhead in bytes.
Some changes were made around dsa_master_set_mtu(), function which was
now removed, for 2 reasons:
- dev_set_mtu() already calls dev_validate_mtu(), so it's redundant to
do the same thing in DSA
- __dev_set_mtu() returns 0 if ops->ndo_change_mtu is an absent method
That is to say, there's no need for this function in DSA, we can safely
call dev_set_mtu() directly, take the rtnl lock when necessary, and just
propagate whatever errors get reported (since the user probably wants to
be informed).
Some inspiration (mainly in the MTU DSA notifier) was taken from a
vaguely similar patch from Murali and Florian, who are credited as
co-developers down below.
Co-developed-by: Murali Krishna Policharla <murali.policharla@broadcom.com>
Signed-off-by: Murali Krishna Policharla <murali.policharla@broadcom.com>
Co-developed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2020-03-27 19:55:42 +00:00
|
|
|
|
net: dsa: targeted MTU notifiers should only match on one port
dsa_slave_change_mtu() calls dsa_port_mtu_change() twice:
- it sends a cross-chip notifier with the MTU of the CPU port which is
used to update the DSA links.
- it sends one targeted MTU notifier which is supposed to only match the
user port on which we are changing the MTU. The "propagate_upstream"
variable is used here to bypass the cross-chip notifier system from
switch.c
But due to a mistake, the second, targeted notifier matches not only on
the user port, but also on the DSA link which is a member of the same
switch, if that exists.
And because the DSA links of the entire dst were programmed in a
previous round to the largest_mtu via a "propagate_upstream == true"
notification, then the dsa_port_mtu_change(propagate_upstream == false)
call that is immediately upcoming will break the MTU on the one DSA link
which is chip-wise local to the dp whose MTU is changing right now.
Example given this daisy chain topology:
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ cpu ] [ user ] [ user ] [ dsa ] [ user ]
[ x ] [ ] [ ] [ x ] [ ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
ip link set sw0p1 mtu 9000
ip link set sw1p1 mtu 9000 # at this stage, sw0p1 and sw1p1 can talk
# to one another using jumbo frames
ip link set sw0p2 mtu 1500 # this programs the sw0p3 DSA link first to
# the largest_mtu of 9000, then reprograms it to
# 1500 with the "propagate_upstream == false"
# notifier, breaking communication between
# sw0p1 and sw1p1
To escape from this situation, make the targeted match really match on a
single port - the user port, and rename the "propagate_upstream"
variable to "targeted_match" to clarify the intention and avoid future
issues.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-06-21 16:42:18 +00:00
|
|
|
/* Do not propagate to other switches in the tree if the notifier was
|
|
|
|
* targeted for a single switch.
|
|
|
|
*/
|
|
|
|
if (info->targeted_match)
|
net: dsa: configure the MTU for switch ports
It is useful be able to configure port policers on a switch to accept
frames of various sizes:
- Increase the MTU for better throughput from the default of 1500 if it
is known that there is no 10/100 Mbps device in the network.
- Decrease the MTU to limit the latency of high-priority frames under
congestion, or work around various network segments that add extra
headers to packets which can't be fragmented.
For DSA slave ports, this is mostly a pass-through callback, called
through the regular ndo ops and at probe time (to ensure consistency
across all supported switches).
The CPU port is called with an MTU equal to the largest configured MTU
of the slave ports. The assumption is that the user might want to
sustain a bidirectional conversation with a partner over any switch
port.
The DSA master is configured the same as the CPU port, plus the tagger
overhead. Since the MTU is by definition L2 payload (sans Ethernet
header), it is up to each individual driver to figure out if it needs to
do anything special for its frame tags on the CPU port (it shouldn't
except in special cases). So the MTU does not contain the tagger
overhead on the CPU port.
However the MTU of the DSA master, minus the tagger overhead, is used as
a proxy for the MTU of the CPU port, which does not have a net device.
This is to avoid uselessly calling the .change_mtu function on the CPU
port when nothing should change.
So it is safe to assume that the DSA master and the CPU port MTUs are
apart by exactly the tagger's overhead in bytes.
Some changes were made around dsa_master_set_mtu(), function which was
now removed, for 2 reasons:
- dev_set_mtu() already calls dev_validate_mtu(), so it's redundant to
do the same thing in DSA
- __dev_set_mtu() returns 0 if ops->ndo_change_mtu is an absent method
That is to say, there's no need for this function in DSA, we can safely
call dev_set_mtu() directly, take the rtnl lock when necessary, and just
propagate whatever errors get reported (since the user probably wants to
be informed).
Some inspiration (mainly in the MTU DSA notifier) was taken from a
vaguely similar patch from Murali and Florian, who are credited as
co-developers down below.
Co-developed-by: Murali Krishna Policharla <murali.policharla@broadcom.com>
Signed-off-by: Murali Krishna Policharla <murali.policharla@broadcom.com>
Co-developed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2020-03-27 19:55:42 +00:00
|
|
|
return false;
|
|
|
|
|
2021-10-20 17:49:53 +00:00
|
|
|
if (dsa_port_is_dsa(dp) || dsa_port_is_cpu(dp))
|
net: dsa: configure the MTU for switch ports
It is useful be able to configure port policers on a switch to accept
frames of various sizes:
- Increase the MTU for better throughput from the default of 1500 if it
is known that there is no 10/100 Mbps device in the network.
- Decrease the MTU to limit the latency of high-priority frames under
congestion, or work around various network segments that add extra
headers to packets which can't be fragmented.
For DSA slave ports, this is mostly a pass-through callback, called
through the regular ndo ops and at probe time (to ensure consistency
across all supported switches).
The CPU port is called with an MTU equal to the largest configured MTU
of the slave ports. The assumption is that the user might want to
sustain a bidirectional conversation with a partner over any switch
port.
The DSA master is configured the same as the CPU port, plus the tagger
overhead. Since the MTU is by definition L2 payload (sans Ethernet
header), it is up to each individual driver to figure out if it needs to
do anything special for its frame tags on the CPU port (it shouldn't
except in special cases). So the MTU does not contain the tagger
overhead on the CPU port.
However the MTU of the DSA master, minus the tagger overhead, is used as
a proxy for the MTU of the CPU port, which does not have a net device.
This is to avoid uselessly calling the .change_mtu function on the CPU
port when nothing should change.
So it is safe to assume that the DSA master and the CPU port MTUs are
apart by exactly the tagger's overhead in bytes.
Some changes were made around dsa_master_set_mtu(), function which was
now removed, for 2 reasons:
- dev_set_mtu() already calls dev_validate_mtu(), so it's redundant to
do the same thing in DSA
- __dev_set_mtu() returns 0 if ops->ndo_change_mtu is an absent method
That is to say, there's no need for this function in DSA, we can safely
call dev_set_mtu() directly, take the rtnl lock when necessary, and just
propagate whatever errors get reported (since the user probably wants to
be informed).
Some inspiration (mainly in the MTU DSA notifier) was taken from a
vaguely similar patch from Murali and Florian, who are credited as
co-developers down below.
Co-developed-by: Murali Krishna Policharla <murali.policharla@broadcom.com>
Signed-off-by: Murali Krishna Policharla <murali.policharla@broadcom.com>
Co-developed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2020-03-27 19:55:42 +00:00
|
|
|
return true;
|
|
|
|
|
|
|
|
return false;
|
|
|
|
}
|
|
|
|
|
|
|
|
static int dsa_switch_mtu(struct dsa_switch *ds,
|
|
|
|
struct dsa_notifier_mtu_info *info)
|
|
|
|
{
|
2021-10-20 17:49:53 +00:00
|
|
|
struct dsa_port *dp;
|
|
|
|
int ret;
|
net: dsa: configure the MTU for switch ports
It is useful be able to configure port policers on a switch to accept
frames of various sizes:
- Increase the MTU for better throughput from the default of 1500 if it
is known that there is no 10/100 Mbps device in the network.
- Decrease the MTU to limit the latency of high-priority frames under
congestion, or work around various network segments that add extra
headers to packets which can't be fragmented.
For DSA slave ports, this is mostly a pass-through callback, called
through the regular ndo ops and at probe time (to ensure consistency
across all supported switches).
The CPU port is called with an MTU equal to the largest configured MTU
of the slave ports. The assumption is that the user might want to
sustain a bidirectional conversation with a partner over any switch
port.
The DSA master is configured the same as the CPU port, plus the tagger
overhead. Since the MTU is by definition L2 payload (sans Ethernet
header), it is up to each individual driver to figure out if it needs to
do anything special for its frame tags on the CPU port (it shouldn't
except in special cases). So the MTU does not contain the tagger
overhead on the CPU port.
However the MTU of the DSA master, minus the tagger overhead, is used as
a proxy for the MTU of the CPU port, which does not have a net device.
This is to avoid uselessly calling the .change_mtu function on the CPU
port when nothing should change.
So it is safe to assume that the DSA master and the CPU port MTUs are
apart by exactly the tagger's overhead in bytes.
Some changes were made around dsa_master_set_mtu(), function which was
now removed, for 2 reasons:
- dev_set_mtu() already calls dev_validate_mtu(), so it's redundant to
do the same thing in DSA
- __dev_set_mtu() returns 0 if ops->ndo_change_mtu is an absent method
That is to say, there's no need for this function in DSA, we can safely
call dev_set_mtu() directly, take the rtnl lock when necessary, and just
propagate whatever errors get reported (since the user probably wants to
be informed).
Some inspiration (mainly in the MTU DSA notifier) was taken from a
vaguely similar patch from Murali and Florian, who are credited as
co-developers down below.
Co-developed-by: Murali Krishna Policharla <murali.policharla@broadcom.com>
Signed-off-by: Murali Krishna Policharla <murali.policharla@broadcom.com>
Co-developed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2020-03-27 19:55:42 +00:00
|
|
|
|
|
|
|
if (!ds->ops->port_change_mtu)
|
|
|
|
return -EOPNOTSUPP;
|
|
|
|
|
2021-10-20 17:49:53 +00:00
|
|
|
dsa_switch_for_each_port(dp, ds) {
|
|
|
|
if (dsa_port_mtu_match(dp, info)) {
|
|
|
|
ret = ds->ops->port_change_mtu(ds, dp->index,
|
|
|
|
info->mtu);
|
net: dsa: configure the MTU for switch ports
It is useful be able to configure port policers on a switch to accept
frames of various sizes:
- Increase the MTU for better throughput from the default of 1500 if it
is known that there is no 10/100 Mbps device in the network.
- Decrease the MTU to limit the latency of high-priority frames under
congestion, or work around various network segments that add extra
headers to packets which can't be fragmented.
For DSA slave ports, this is mostly a pass-through callback, called
through the regular ndo ops and at probe time (to ensure consistency
across all supported switches).
The CPU port is called with an MTU equal to the largest configured MTU
of the slave ports. The assumption is that the user might want to
sustain a bidirectional conversation with a partner over any switch
port.
The DSA master is configured the same as the CPU port, plus the tagger
overhead. Since the MTU is by definition L2 payload (sans Ethernet
header), it is up to each individual driver to figure out if it needs to
do anything special for its frame tags on the CPU port (it shouldn't
except in special cases). So the MTU does not contain the tagger
overhead on the CPU port.
However the MTU of the DSA master, minus the tagger overhead, is used as
a proxy for the MTU of the CPU port, which does not have a net device.
This is to avoid uselessly calling the .change_mtu function on the CPU
port when nothing should change.
So it is safe to assume that the DSA master and the CPU port MTUs are
apart by exactly the tagger's overhead in bytes.
Some changes were made around dsa_master_set_mtu(), function which was
now removed, for 2 reasons:
- dev_set_mtu() already calls dev_validate_mtu(), so it's redundant to
do the same thing in DSA
- __dev_set_mtu() returns 0 if ops->ndo_change_mtu is an absent method
That is to say, there's no need for this function in DSA, we can safely
call dev_set_mtu() directly, take the rtnl lock when necessary, and just
propagate whatever errors get reported (since the user probably wants to
be informed).
Some inspiration (mainly in the MTU DSA notifier) was taken from a
vaguely similar patch from Murali and Florian, who are credited as
co-developers down below.
Co-developed-by: Murali Krishna Policharla <murali.policharla@broadcom.com>
Signed-off-by: Murali Krishna Policharla <murali.policharla@broadcom.com>
Co-developed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2020-03-27 19:55:42 +00:00
|
|
|
if (ret)
|
|
|
|
return ret;
|
|
|
|
}
|
|
|
|
}
|
|
|
|
|
|
|
|
return 0;
|
|
|
|
}
|
|
|
|
|
2017-02-03 18:20:21 +00:00
|
|
|
static int dsa_switch_bridge_join(struct dsa_switch *ds,
|
|
|
|
struct dsa_notifier_bridge_info *info)
|
|
|
|
{
|
net: dsa: tag_8021q: manage RX VLANs dynamically at bridge join/leave time
There has been at least one wasted opportunity for tag_8021q to be used
by a driver:
https://patchwork.ozlabs.org/project/netdev/patch/20200710113611.3398-3-kurt@linutronix.de/#2484272
because of a design decision: the declared purpose of tag_8021q is to
offer source port/switch identification for a tagging driver for packets
coming from a switch with no hardware DSA tagging support. It is not
intended to provide VLAN-based port isolation, because its first user,
sja1105, had another mechanism for bridging domain isolation, the L2
Forwarding Table. So even if 2 ports are in the same VLAN but they are
separated via the L2 Forwarding Table, they will not communicate with
one another. The L2 Forwarding Table is managed by the
sja1105_bridge_join() and sja1105_bridge_leave() methods.
As a consequence, today tag_8021q does not bother too much with hooking
into .port_bridge_join() and .port_bridge_leave() because that would
introduce yet another degree of freedom, it just iterates statically
through all ports of a switch and adds the RX VLAN of one port to all
the others. In this way, whenever .port_bridge_join() is called,
bridging will magically work because the RX VLANs are already installed
everywhere they need to be.
This is not to say that the reason for the change in this patch is to
satisfy the hellcreek and similar use cases, that is merely a nice side
effect. Instead it is to make sja1105 cross-chip links work properly
over a DSA link.
For context, sja1105 today supports a degenerate form of cross-chip
bridging, where the switches are interconnected through their CPU ports
("disjoint trees" topology). There is some code which has been
generalized into dsa_8021q_crosschip_link_{add,del}, but it is not
enough, and frankly it is impossible to build upon that.
Real multi-switch DSA trees, like daisy chains or H trees, which have
actual DSA links, do not work.
The problem is that sja1105 is unlike mv88e6xxx, and does not have a PVT
for cross-chip bridging, which is a table by which the local switch can
select the forwarding domain for packets from a certain ingress switch
ID and source port. The sja1105 switches cannot parse their own DSA
tags, because, well, they don't really have support for DSA tags, it's
all VLANs.
So to make something like cross-chip bridging between sw0p0 and sw1p0 to
work over the sw0p3/sw1p3 DSA link to work with sja1105 in the topology
below:
| |
sw0p0 sw0p1 sw0p2 sw0p3 sw1p3 sw1p2 sw1p1 sw1p0
[ user ] [ user ] [ cpu ] [ dsa ] ---- [ dsa ] [ cpu ] [ user ] [ user ]
we need to ask ourselves 2 questions:
(1) how should the L2 Forwarding Table be managed?
(2) how should the VLAN Lookup Table be managed?
i.e. what should prevent packets from going to unwanted ports?
Since as mentioned, there is no PVT, the L2 Forwarding Table only
contains forwarding rules for local ports. So we can say "all user ports
are allowed to forward to all CPU ports and all DSA links".
If we allow forwarding to DSA links unconditionally, this means we must
prevent forwarding using the VLAN Lookup Table. This is in fact
asymmetric with what we do for tag_8021q on ports local to the same
switch, and it matters because now that we are making tag_8021q a core
DSA feature, we need to hook into .crosschip_bridge_join() to add/remove
the tag_8021q VLANs. So for symmetry it makes sense to manage the VLANs
for local forwarding in the same way as cross-chip forwarding.
Note that there is a very precise reason why tag_8021q hooks into
dsa_switch_bridge_join() which acts at the cross-chip notifier level,
and not at a higher level such as dsa_port_bridge_join(). We need to
install the RX VLAN of the newly joining port into the VLAN table of all
the existing ports across the tree that are part of the same bridge, and
the notifier already does the iteration through the switches for us.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-07-19 17:14:51 +00:00
|
|
|
int err;
|
net: dsa: permit cross-chip bridging between all trees in the system
One way of utilizing DSA is by cascading switches which do not all have
compatible taggers. Consider the following real-life topology:
+---------------------------------------------------------------+
| LS1028A |
| +------------------------------+ |
| | DSA master for Felix | |
| |(internal ENETC port 2: eno2))| |
| +------------+------------------------------+-------------+ |
| | Felix embedded L2 switch | |
| | | |
| | +--------------+ +--------------+ +--------------+ | |
| | |DSA master for| |DSA master for| |DSA master for| | |
| | | SJA1105 1 | | SJA1105 2 | | SJA1105 3 | | |
| | |(Felix port 1)| |(Felix port 2)| |(Felix port 3)| | |
+--+-+--------------+---+--------------+---+--------------+--+--+
+-----------------------+ +-----------------------+ +-----------------------+
| SJA1105 switch 1 | | SJA1105 switch 2 | | SJA1105 switch 3 |
+-----+-----+-----+-----+ +-----+-----+-----+-----+ +-----+-----+-----+-----+
|sw1p0|sw1p1|sw1p2|sw1p3| |sw2p0|sw2p1|sw2p2|sw2p3| |sw3p0|sw3p1|sw3p2|sw3p3|
+-----+-----+-----+-----+ +-----+-----+-----+-----+ +-----+-----+-----+-----+
The above can be described in the device tree as follows (obviously not
complete):
mscc_felix {
dsa,member = <0 0>;
ports {
port@4 {
ethernet = <&enetc_port2>;
};
};
};
sja1105_switch1 {
dsa,member = <1 1>;
ports {
port@4 {
ethernet = <&mscc_felix_port1>;
};
};
};
sja1105_switch2 {
dsa,member = <2 2>;
ports {
port@4 {
ethernet = <&mscc_felix_port2>;
};
};
};
sja1105_switch3 {
dsa,member = <3 3>;
ports {
port@4 {
ethernet = <&mscc_felix_port3>;
};
};
};
Basically we instantiate one DSA switch tree for every hardware switch
in the system, but we still give them globally unique switch IDs (will
come back to that later). Having 3 disjoint switch trees makes the
tagger drivers "just work", because net devices are registered for the
3 Felix DSA master ports, and they are also DSA slave ports to the ENETC
port. So packets received on the ENETC port are stripped of their
stacked DSA tags one by one.
Currently, hardware bridging between ports on the same sja1105 chip is
possible, but switching between sja1105 ports on different chips is
handled by the software bridge. This is fine, but we can do better.
In fact, the dsa_8021q tag used by sja1105 is compatible with cascading.
In other words, a sja1105 switch can correctly parse and route a packet
containing a dsa_8021q tag. So if we could enable hardware bridging on
the Felix DSA master ports, cross-chip bridging could be completely
offloaded.
Such as system would be used as follows:
ip link add dev br0 type bridge && ip link set dev br0 up
for port in sw0p0 sw0p1 sw0p2 sw0p3 \
sw1p0 sw1p1 sw1p2 sw1p3 \
sw2p0 sw2p1 sw2p2 sw2p3; do
ip link set dev $port master br0
done
The above makes switching between ports on the same row be performed in
hardware, and between ports on different rows in software. Now assume
the Felix switch ports are called swp0, swp1, swp2. By running the
following extra commands:
ip link add dev br1 type bridge && ip link set dev br1 up
for port in swp0 swp1 swp2; do
ip link set dev $port master br1
done
the CPU no longer sees packets which traverse sja1105 switch boundaries
and can be forwarded directly by Felix. The br1 bridge would not be used
for any sort of traffic termination.
For this to work, we need to give drivers an opportunity to listen for
bridging events on DSA trees other than their own, and pass that other
tree index as argument. I have made the assumption, for the moment, that
the other existing DSA notifiers don't need to be broadcast to other
trees. That assumption might turn out to be incorrect. But in the
meantime, introduce a dsa_broadcast function, similar in purpose to
dsa_port_notify, which is used only by the bridging notifiers.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: Jakub Kicinski <kuba@kernel.org>
2020-05-10 16:37:41 +00:00
|
|
|
|
net: dsa: make cross-chip notifiers more efficient for host events
To determine whether a given port should react to the port targeted by
the notifier, dsa_port_host_vlan_match() and dsa_port_host_address_match()
look at the positioning of the switch port currently executing the
notifier relative to the switch port for which the notifier was emitted.
To maintain stylistic compatibility with the other match functions from
switch.c, the host address and host VLAN match functions take the
notifier information about targeted port, switch and tree indices as
argument. However, these functions only use that information to retrieve
the struct dsa_port *targeted_dp, which is an invariant for the outer
loop that calls them. So it makes more sense to calculate the targeted
dp only once, and pass it to them as argument.
But furthermore, the targeted dp is actually known at the time the call
to dsa_port_notify() is made. It is just that we decide to only save the
indices of the port, switch and tree in the notifier structure, just to
retrace our steps and find the dp again using dsa_switch_find() and
dsa_to_port().
But both the above functions are relatively expensive, since they need
to iterate through lists. It appears more straightforward to make all
notifiers just pass the targeted dp inside their info structure, and
have the code that needs the indices to look at info->dp->index instead
of info->port, or info->dp->ds->index instead of info->sw_index, or
info->dp->ds->dst->index instead of info->tree_index.
For the sake of consistency, all cross-chip notifiers are converted to
pass the "dp" directly.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-04-15 15:46:22 +00:00
|
|
|
if (info->dp->ds == ds) {
|
net: dsa: properly fall back to software bridging
If the driver does not implement .port_bridge_{join,leave}, then we must
fall back to standalone operation on that port, and trigger the error
path of dsa_port_bridge_join. This sets dp->bridge_dev = NULL.
In turn, having a non-NULL dp->bridge_dev when there is no offloading
support makes the following things go wrong:
- dsa_default_offload_fwd_mark make the wrong decision in setting
skb->offload_fwd_mark. It should set skb->offload_fwd_mark = 0 for
ports that don't offload the bridge, which should instruct the bridge
to forward in software. But this does not happen, dp->bridge_dev is
incorrectly set to point to the bridge, so the bridge is told that
packets have been forwarded in hardware, which they haven't.
- switchdev objects (MDBs, VLANs) should not be offloaded by ports that
don't offload the bridge. Standalone ports should behave as packet-in,
packet-out and the bridge should not be able to manipulate the pvid of
the port, or tag stripping on egress, or ingress filtering. This
should already work fine because dsa_slave_port_obj_add has:
case SWITCHDEV_OBJ_ID_PORT_VLAN:
if (!dsa_port_offloads_bridge_port(dp, obj->orig_dev))
return -EOPNOTSUPP;
err = dsa_slave_vlan_add(dev, obj, extack);
but since dsa_port_offloads_bridge_port works based on dp->bridge_dev,
this is again sabotaging us.
All the above work in case the port has an unoffloaded LAG interface, so
this is well exercised code, we should apply it for plain unoffloaded
bridge ports too.
Reported-by: Alvin Šipraga <alsi@bang-olufsen.dk>
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-08-23 21:22:56 +00:00
|
|
|
if (!ds->ops->port_bridge_join)
|
|
|
|
return -EOPNOTSUPP;
|
|
|
|
|
net: dsa: make cross-chip notifiers more efficient for host events
To determine whether a given port should react to the port targeted by
the notifier, dsa_port_host_vlan_match() and dsa_port_host_address_match()
look at the positioning of the switch port currently executing the
notifier relative to the switch port for which the notifier was emitted.
To maintain stylistic compatibility with the other match functions from
switch.c, the host address and host VLAN match functions take the
notifier information about targeted port, switch and tree indices as
argument. However, these functions only use that information to retrieve
the struct dsa_port *targeted_dp, which is an invariant for the outer
loop that calls them. So it makes more sense to calculate the targeted
dp only once, and pass it to them as argument.
But furthermore, the targeted dp is actually known at the time the call
to dsa_port_notify() is made. It is just that we decide to only save the
indices of the port, switch and tree in the notifier structure, just to
retrace our steps and find the dp again using dsa_switch_find() and
dsa_to_port().
But both the above functions are relatively expensive, since they need
to iterate through lists. It appears more straightforward to make all
notifiers just pass the targeted dp inside their info structure, and
have the code that needs the indices to look at info->dp->index instead
of info->port, or info->dp->ds->index instead of info->sw_index, or
info->dp->ds->dst->index instead of info->tree_index.
For the sake of consistency, all cross-chip notifiers are converted to
pass the "dp" directly.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-04-15 15:46:22 +00:00
|
|
|
err = ds->ops->port_bridge_join(ds, info->dp->index,
|
|
|
|
info->bridge,
|
2022-02-25 09:22:23 +00:00
|
|
|
&info->tx_fwd_offload,
|
|
|
|
info->extack);
|
net: dsa: tag_8021q: manage RX VLANs dynamically at bridge join/leave time
There has been at least one wasted opportunity for tag_8021q to be used
by a driver:
https://patchwork.ozlabs.org/project/netdev/patch/20200710113611.3398-3-kurt@linutronix.de/#2484272
because of a design decision: the declared purpose of tag_8021q is to
offer source port/switch identification for a tagging driver for packets
coming from a switch with no hardware DSA tagging support. It is not
intended to provide VLAN-based port isolation, because its first user,
sja1105, had another mechanism for bridging domain isolation, the L2
Forwarding Table. So even if 2 ports are in the same VLAN but they are
separated via the L2 Forwarding Table, they will not communicate with
one another. The L2 Forwarding Table is managed by the
sja1105_bridge_join() and sja1105_bridge_leave() methods.
As a consequence, today tag_8021q does not bother too much with hooking
into .port_bridge_join() and .port_bridge_leave() because that would
introduce yet another degree of freedom, it just iterates statically
through all ports of a switch and adds the RX VLAN of one port to all
the others. In this way, whenever .port_bridge_join() is called,
bridging will magically work because the RX VLANs are already installed
everywhere they need to be.
This is not to say that the reason for the change in this patch is to
satisfy the hellcreek and similar use cases, that is merely a nice side
effect. Instead it is to make sja1105 cross-chip links work properly
over a DSA link.
For context, sja1105 today supports a degenerate form of cross-chip
bridging, where the switches are interconnected through their CPU ports
("disjoint trees" topology). There is some code which has been
generalized into dsa_8021q_crosschip_link_{add,del}, but it is not
enough, and frankly it is impossible to build upon that.
Real multi-switch DSA trees, like daisy chains or H trees, which have
actual DSA links, do not work.
The problem is that sja1105 is unlike mv88e6xxx, and does not have a PVT
for cross-chip bridging, which is a table by which the local switch can
select the forwarding domain for packets from a certain ingress switch
ID and source port. The sja1105 switches cannot parse their own DSA
tags, because, well, they don't really have support for DSA tags, it's
all VLANs.
So to make something like cross-chip bridging between sw0p0 and sw1p0 to
work over the sw0p3/sw1p3 DSA link to work with sja1105 in the topology
below:
| |
sw0p0 sw0p1 sw0p2 sw0p3 sw1p3 sw1p2 sw1p1 sw1p0
[ user ] [ user ] [ cpu ] [ dsa ] ---- [ dsa ] [ cpu ] [ user ] [ user ]
we need to ask ourselves 2 questions:
(1) how should the L2 Forwarding Table be managed?
(2) how should the VLAN Lookup Table be managed?
i.e. what should prevent packets from going to unwanted ports?
Since as mentioned, there is no PVT, the L2 Forwarding Table only
contains forwarding rules for local ports. So we can say "all user ports
are allowed to forward to all CPU ports and all DSA links".
If we allow forwarding to DSA links unconditionally, this means we must
prevent forwarding using the VLAN Lookup Table. This is in fact
asymmetric with what we do for tag_8021q on ports local to the same
switch, and it matters because now that we are making tag_8021q a core
DSA feature, we need to hook into .crosschip_bridge_join() to add/remove
the tag_8021q VLANs. So for symmetry it makes sense to manage the VLANs
for local forwarding in the same way as cross-chip forwarding.
Note that there is a very precise reason why tag_8021q hooks into
dsa_switch_bridge_join() which acts at the cross-chip notifier level,
and not at a higher level such as dsa_port_bridge_join(). We need to
install the RX VLAN of the newly joining port into the VLAN table of all
the existing ports across the tree that are part of the same bridge, and
the notifier already does the iteration through the switches for us.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-07-19 17:14:51 +00:00
|
|
|
if (err)
|
|
|
|
return err;
|
|
|
|
}
|
2017-02-03 18:20:21 +00:00
|
|
|
|
net: dsa: make cross-chip notifiers more efficient for host events
To determine whether a given port should react to the port targeted by
the notifier, dsa_port_host_vlan_match() and dsa_port_host_address_match()
look at the positioning of the switch port currently executing the
notifier relative to the switch port for which the notifier was emitted.
To maintain stylistic compatibility with the other match functions from
switch.c, the host address and host VLAN match functions take the
notifier information about targeted port, switch and tree indices as
argument. However, these functions only use that information to retrieve
the struct dsa_port *targeted_dp, which is an invariant for the outer
loop that calls them. So it makes more sense to calculate the targeted
dp only once, and pass it to them as argument.
But furthermore, the targeted dp is actually known at the time the call
to dsa_port_notify() is made. It is just that we decide to only save the
indices of the port, switch and tree in the notifier structure, just to
retrace our steps and find the dp again using dsa_switch_find() and
dsa_to_port().
But both the above functions are relatively expensive, since they need
to iterate through lists. It appears more straightforward to make all
notifiers just pass the targeted dp inside their info structure, and
have the code that needs the indices to look at info->dp->index instead
of info->port, or info->dp->ds->index instead of info->sw_index, or
info->dp->ds->dst->index instead of info->tree_index.
For the sake of consistency, all cross-chip notifiers are converted to
pass the "dp" directly.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-04-15 15:46:22 +00:00
|
|
|
if (info->dp->ds != ds && ds->ops->crosschip_bridge_join) {
|
|
|
|
err = ds->ops->crosschip_bridge_join(ds,
|
|
|
|
info->dp->ds->dst->index,
|
|
|
|
info->dp->ds->index,
|
|
|
|
info->dp->index,
|
|
|
|
info->bridge,
|
2022-02-25 09:22:23 +00:00
|
|
|
info->extack);
|
net: dsa: tag_8021q: manage RX VLANs dynamically at bridge join/leave time
There has been at least one wasted opportunity for tag_8021q to be used
by a driver:
https://patchwork.ozlabs.org/project/netdev/patch/20200710113611.3398-3-kurt@linutronix.de/#2484272
because of a design decision: the declared purpose of tag_8021q is to
offer source port/switch identification for a tagging driver for packets
coming from a switch with no hardware DSA tagging support. It is not
intended to provide VLAN-based port isolation, because its first user,
sja1105, had another mechanism for bridging domain isolation, the L2
Forwarding Table. So even if 2 ports are in the same VLAN but they are
separated via the L2 Forwarding Table, they will not communicate with
one another. The L2 Forwarding Table is managed by the
sja1105_bridge_join() and sja1105_bridge_leave() methods.
As a consequence, today tag_8021q does not bother too much with hooking
into .port_bridge_join() and .port_bridge_leave() because that would
introduce yet another degree of freedom, it just iterates statically
through all ports of a switch and adds the RX VLAN of one port to all
the others. In this way, whenever .port_bridge_join() is called,
bridging will magically work because the RX VLANs are already installed
everywhere they need to be.
This is not to say that the reason for the change in this patch is to
satisfy the hellcreek and similar use cases, that is merely a nice side
effect. Instead it is to make sja1105 cross-chip links work properly
over a DSA link.
For context, sja1105 today supports a degenerate form of cross-chip
bridging, where the switches are interconnected through their CPU ports
("disjoint trees" topology). There is some code which has been
generalized into dsa_8021q_crosschip_link_{add,del}, but it is not
enough, and frankly it is impossible to build upon that.
Real multi-switch DSA trees, like daisy chains or H trees, which have
actual DSA links, do not work.
The problem is that sja1105 is unlike mv88e6xxx, and does not have a PVT
for cross-chip bridging, which is a table by which the local switch can
select the forwarding domain for packets from a certain ingress switch
ID and source port. The sja1105 switches cannot parse their own DSA
tags, because, well, they don't really have support for DSA tags, it's
all VLANs.
So to make something like cross-chip bridging between sw0p0 and sw1p0 to
work over the sw0p3/sw1p3 DSA link to work with sja1105 in the topology
below:
| |
sw0p0 sw0p1 sw0p2 sw0p3 sw1p3 sw1p2 sw1p1 sw1p0
[ user ] [ user ] [ cpu ] [ dsa ] ---- [ dsa ] [ cpu ] [ user ] [ user ]
we need to ask ourselves 2 questions:
(1) how should the L2 Forwarding Table be managed?
(2) how should the VLAN Lookup Table be managed?
i.e. what should prevent packets from going to unwanted ports?
Since as mentioned, there is no PVT, the L2 Forwarding Table only
contains forwarding rules for local ports. So we can say "all user ports
are allowed to forward to all CPU ports and all DSA links".
If we allow forwarding to DSA links unconditionally, this means we must
prevent forwarding using the VLAN Lookup Table. This is in fact
asymmetric with what we do for tag_8021q on ports local to the same
switch, and it matters because now that we are making tag_8021q a core
DSA feature, we need to hook into .crosschip_bridge_join() to add/remove
the tag_8021q VLANs. So for symmetry it makes sense to manage the VLANs
for local forwarding in the same way as cross-chip forwarding.
Note that there is a very precise reason why tag_8021q hooks into
dsa_switch_bridge_join() which acts at the cross-chip notifier level,
and not at a higher level such as dsa_port_bridge_join(). We need to
install the RX VLAN of the newly joining port into the VLAN table of all
the existing ports across the tree that are part of the same bridge, and
the notifier already does the iteration through the switches for us.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-07-19 17:14:51 +00:00
|
|
|
if (err)
|
|
|
|
return err;
|
|
|
|
}
|
2017-02-03 18:20:21 +00:00
|
|
|
|
net: dsa: tag_8021q: replace the SVL bridging with VLAN-unaware IVL bridging
For VLAN-unaware bridging, tag_8021q uses something perhaps a bit too
tied with the sja1105 switch: each port uses the same pvid which is also
used for standalone operation (a unique one from which the source port
and device ID can be retrieved when packets from that port are forwarded
to the CPU). Since each port has a unique pvid when performing
autonomous forwarding, the switch must be configured for Shared VLAN
Learning (SVL) such that the VLAN ID itself is ignored when performing
FDB lookups. Without SVL, packets would always be flooded, since FDB
lookup in the source port's VLAN would never find any entry.
First of all, to make tag_8021q more palatable to switches which might
not support Shared VLAN Learning, let's just use a common VLAN for all
ports that are under the same bridge.
Secondly, using Shared VLAN Learning means that FDB isolation can never
be enforced. But if all ports under the same VLAN-unaware bridge share
the same VLAN ID, it can.
The disadvantage is that the CPU port can no longer perform precise
source port identification for these packets. But at least we have a
mechanism which has proven to be adequate for that situation: imprecise
RX (dsa_find_designated_bridge_port_by_vid), which is what we use for
termination on VLAN-aware bridges.
The VLAN ID that VLAN-unaware bridges will use with tag_8021q is the
same one as we were previously using for imprecise TX (bridge TX
forwarding offload). It is already allocated, it is just a matter of
using it.
Note that because now all ports under the same bridge share the same
VLAN, the complexity of performing a tag_8021q bridge join decreases
dramatically. We no longer have to install the RX VLAN of a newly
joining port into the port membership of the existing bridge ports.
The newly joining port just becomes a member of the VLAN corresponding
to that bridge, and the other ports are already members of it from when
they joined the bridge themselves. So forwarding works properly.
This means that we can unhook dsa_tag_8021q_bridge_{join,leave} from the
cross-chip notifier level dsa_switch_bridge_{join,leave}. We can put
these calls directly into the sja1105 driver.
With this new mode of operation, a port controlled by tag_8021q can have
two pvids whereas before it could only have one. The pvid for standalone
operation is different from the pvid used for VLAN-unaware bridging.
This is done, again, so that FDB isolation can be enforced.
Let tag_8021q manage this by deleting the standalone pvid when a port
joins a bridge, and restoring it when it leaves it.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-02-25 09:22:16 +00:00
|
|
|
return 0;
|
2017-02-03 18:20:21 +00:00
|
|
|
}
|
|
|
|
|
2022-01-24 21:09:43 +00:00
|
|
|
static int dsa_switch_bridge_leave(struct dsa_switch *ds,
|
|
|
|
struct dsa_notifier_bridge_info *info)
|
|
|
|
{
|
net: dsa: make cross-chip notifiers more efficient for host events
To determine whether a given port should react to the port targeted by
the notifier, dsa_port_host_vlan_match() and dsa_port_host_address_match()
look at the positioning of the switch port currently executing the
notifier relative to the switch port for which the notifier was emitted.
To maintain stylistic compatibility with the other match functions from
switch.c, the host address and host VLAN match functions take the
notifier information about targeted port, switch and tree indices as
argument. However, these functions only use that information to retrieve
the struct dsa_port *targeted_dp, which is an invariant for the outer
loop that calls them. So it makes more sense to calculate the targeted
dp only once, and pass it to them as argument.
But furthermore, the targeted dp is actually known at the time the call
to dsa_port_notify() is made. It is just that we decide to only save the
indices of the port, switch and tree in the notifier structure, just to
retrace our steps and find the dp again using dsa_switch_find() and
dsa_to_port().
But both the above functions are relatively expensive, since they need
to iterate through lists. It appears more straightforward to make all
notifiers just pass the targeted dp inside their info structure, and
have the code that needs the indices to look at info->dp->index instead
of info->port, or info->dp->ds->index instead of info->sw_index, or
info->dp->ds->dst->index instead of info->tree_index.
For the sake of consistency, all cross-chip notifiers are converted to
pass the "dp" directly.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-04-15 15:46:22 +00:00
|
|
|
if (info->dp->ds == ds && ds->ops->port_bridge_leave)
|
|
|
|
ds->ops->port_bridge_leave(ds, info->dp->index, info->bridge);
|
2022-01-24 21:09:43 +00:00
|
|
|
|
net: dsa: make cross-chip notifiers more efficient for host events
To determine whether a given port should react to the port targeted by
the notifier, dsa_port_host_vlan_match() and dsa_port_host_address_match()
look at the positioning of the switch port currently executing the
notifier relative to the switch port for which the notifier was emitted.
To maintain stylistic compatibility with the other match functions from
switch.c, the host address and host VLAN match functions take the
notifier information about targeted port, switch and tree indices as
argument. However, these functions only use that information to retrieve
the struct dsa_port *targeted_dp, which is an invariant for the outer
loop that calls them. So it makes more sense to calculate the targeted
dp only once, and pass it to them as argument.
But furthermore, the targeted dp is actually known at the time the call
to dsa_port_notify() is made. It is just that we decide to only save the
indices of the port, switch and tree in the notifier structure, just to
retrace our steps and find the dp again using dsa_switch_find() and
dsa_to_port().
But both the above functions are relatively expensive, since they need
to iterate through lists. It appears more straightforward to make all
notifiers just pass the targeted dp inside their info structure, and
have the code that needs the indices to look at info->dp->index instead
of info->port, or info->dp->ds->index instead of info->sw_index, or
info->dp->ds->dst->index instead of info->tree_index.
For the sake of consistency, all cross-chip notifiers are converted to
pass the "dp" directly.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-04-15 15:46:22 +00:00
|
|
|
if (info->dp->ds != ds && ds->ops->crosschip_bridge_leave)
|
|
|
|
ds->ops->crosschip_bridge_leave(ds, info->dp->ds->dst->index,
|
|
|
|
info->dp->ds->index,
|
|
|
|
info->dp->index,
|
2022-01-24 21:09:43 +00:00
|
|
|
info->bridge);
|
|
|
|
|
net: dsa: tag_8021q: replace the SVL bridging with VLAN-unaware IVL bridging
For VLAN-unaware bridging, tag_8021q uses something perhaps a bit too
tied with the sja1105 switch: each port uses the same pvid which is also
used for standalone operation (a unique one from which the source port
and device ID can be retrieved when packets from that port are forwarded
to the CPU). Since each port has a unique pvid when performing
autonomous forwarding, the switch must be configured for Shared VLAN
Learning (SVL) such that the VLAN ID itself is ignored when performing
FDB lookups. Without SVL, packets would always be flooded, since FDB
lookup in the source port's VLAN would never find any entry.
First of all, to make tag_8021q more palatable to switches which might
not support Shared VLAN Learning, let's just use a common VLAN for all
ports that are under the same bridge.
Secondly, using Shared VLAN Learning means that FDB isolation can never
be enforced. But if all ports under the same VLAN-unaware bridge share
the same VLAN ID, it can.
The disadvantage is that the CPU port can no longer perform precise
source port identification for these packets. But at least we have a
mechanism which has proven to be adequate for that situation: imprecise
RX (dsa_find_designated_bridge_port_by_vid), which is what we use for
termination on VLAN-aware bridges.
The VLAN ID that VLAN-unaware bridges will use with tag_8021q is the
same one as we were previously using for imprecise TX (bridge TX
forwarding offload). It is already allocated, it is just a matter of
using it.
Note that because now all ports under the same bridge share the same
VLAN, the complexity of performing a tag_8021q bridge join decreases
dramatically. We no longer have to install the RX VLAN of a newly
joining port into the port membership of the existing bridge ports.
The newly joining port just becomes a member of the VLAN corresponding
to that bridge, and the other ports are already members of it from when
they joined the bridge themselves. So forwarding works properly.
This means that we can unhook dsa_tag_8021q_bridge_{join,leave} from the
cross-chip notifier level dsa_switch_bridge_{join,leave}. We can put
these calls directly into the sja1105 driver.
With this new mode of operation, a port controlled by tag_8021q can have
two pvids whereas before it could only have one. The pvid for standalone
operation is different from the pvid used for VLAN-unaware bridging.
This is done, again, so that FDB isolation can be enforced.
Let tag_8021q manage this by deleting the standalone pvid when a port
joins a bridge, and restoring it when it leaves it.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-02-25 09:22:16 +00:00
|
|
|
return 0;
|
2017-02-03 18:20:21 +00:00
|
|
|
}
|
|
|
|
|
net: dsa: introduce a separate cross-chip notifier type for host MDBs
Commit abd49535c380 ("net: dsa: execute dsa_switch_mdb_add only for
routing port in cross-chip topologies") does a surprisingly good job
even for the SWITCHDEV_OBJ_ID_HOST_MDB use case, where DSA simply
translates a switchdev object received on dp into a cross-chip notifier
for dp->cpu_dp.
To visualize how that works, imagine the daisy chain topology below and
consider a SWITCHDEV_OBJ_ID_HOST_MDB object emitted on sw2p0. How does
the cross-chip notifier know to match on all the right ports (sw0p4, the
dedicated CPU port, sw1p4, an upstream DSA link, and sw2p4, another
upstream DSA link)?
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ ] [ ] [ ] [ ] [ x ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
The answer is simple: the dedicated CPU port of sw2p0 is sw0p4, and
dsa_routing_port returns the upstream port for all switches.
That is fine, but there are other topologies where this does not work as
well. There are trees with "H" topologies in the wild, where there are 2
or more switches with DSA links between them, but every switch has its
dedicated CPU port. For these topologies, it seems stupid for the neighbor
switches to install an MDB entry on the routing port, since these
multicast addresses are fundamentally different than the usual ones we
support (and that is the justification for this patch, to introduce the
concept of a termination plane multicast MAC address, as opposed to a
forwarding plane multicast MAC address).
For example, when a SWITCHDEV_OBJ_ID_HOST_MDB would get added to sw0p0,
without this patch, it would get treated as a regular port MDB on sw0p2
and it would match on the ports below (including the sw1p3 routing port).
| |
sw0p0 sw0p1 sw0p2 sw0p3 sw1p3 sw1p2 sw1p1 sw1p0
[ user ] [ user ] [ cpu ] [ dsa ] [ dsa ] [ cpu ] [ user ] [ user ]
[ ] [ ] [ x ] [ ] ---- [ x ] [ ] [ ] [ ]
With the patch, the host MDB notifier on sw0p0 matches only on the local
switch, which is what we want for a termination plane address.
| |
sw0p0 sw0p1 sw0p2 sw0p3 sw1p3 sw1p2 sw1p1 sw1p0
[ user ] [ user ] [ cpu ] [ dsa ] [ dsa ] [ cpu ] [ user ] [ user ]
[ ] [ ] [ x ] [ ] ---- [ ] [ ] [ ] [ ]
Name this new matching function "dsa_switch_host_address_match" since we
will be reusing it soon for host FDB entries as well.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-06-29 14:06:49 +00:00
|
|
|
/* Matches for all upstream-facing ports (the CPU port and all upstream-facing
|
|
|
|
* DSA links) that sit between the targeted port on which the notifier was
|
|
|
|
* emitted and its dedicated CPU port.
|
|
|
|
*/
|
2021-10-20 17:49:53 +00:00
|
|
|
static bool dsa_port_host_address_match(struct dsa_port *dp,
|
net: dsa: make cross-chip notifiers more efficient for host events
To determine whether a given port should react to the port targeted by
the notifier, dsa_port_host_vlan_match() and dsa_port_host_address_match()
look at the positioning of the switch port currently executing the
notifier relative to the switch port for which the notifier was emitted.
To maintain stylistic compatibility with the other match functions from
switch.c, the host address and host VLAN match functions take the
notifier information about targeted port, switch and tree indices as
argument. However, these functions only use that information to retrieve
the struct dsa_port *targeted_dp, which is an invariant for the outer
loop that calls them. So it makes more sense to calculate the targeted
dp only once, and pass it to them as argument.
But furthermore, the targeted dp is actually known at the time the call
to dsa_port_notify() is made. It is just that we decide to only save the
indices of the port, switch and tree in the notifier structure, just to
retrace our steps and find the dp again using dsa_switch_find() and
dsa_to_port().
But both the above functions are relatively expensive, since they need
to iterate through lists. It appears more straightforward to make all
notifiers just pass the targeted dp inside their info structure, and
have the code that needs the indices to look at info->dp->index instead
of info->port, or info->dp->ds->index instead of info->sw_index, or
info->dp->ds->dst->index instead of info->tree_index.
For the sake of consistency, all cross-chip notifiers are converted to
pass the "dp" directly.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-04-15 15:46:22 +00:00
|
|
|
const struct dsa_port *targeted_dp)
|
net: dsa: introduce a separate cross-chip notifier type for host MDBs
Commit abd49535c380 ("net: dsa: execute dsa_switch_mdb_add only for
routing port in cross-chip topologies") does a surprisingly good job
even for the SWITCHDEV_OBJ_ID_HOST_MDB use case, where DSA simply
translates a switchdev object received on dp into a cross-chip notifier
for dp->cpu_dp.
To visualize how that works, imagine the daisy chain topology below and
consider a SWITCHDEV_OBJ_ID_HOST_MDB object emitted on sw2p0. How does
the cross-chip notifier know to match on all the right ports (sw0p4, the
dedicated CPU port, sw1p4, an upstream DSA link, and sw2p4, another
upstream DSA link)?
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ ] [ ] [ ] [ ] [ x ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
The answer is simple: the dedicated CPU port of sw2p0 is sw0p4, and
dsa_routing_port returns the upstream port for all switches.
That is fine, but there are other topologies where this does not work as
well. There are trees with "H" topologies in the wild, where there are 2
or more switches with DSA links between them, but every switch has its
dedicated CPU port. For these topologies, it seems stupid for the neighbor
switches to install an MDB entry on the routing port, since these
multicast addresses are fundamentally different than the usual ones we
support (and that is the justification for this patch, to introduce the
concept of a termination plane multicast MAC address, as opposed to a
forwarding plane multicast MAC address).
For example, when a SWITCHDEV_OBJ_ID_HOST_MDB would get added to sw0p0,
without this patch, it would get treated as a regular port MDB on sw0p2
and it would match on the ports below (including the sw1p3 routing port).
| |
sw0p0 sw0p1 sw0p2 sw0p3 sw1p3 sw1p2 sw1p1 sw1p0
[ user ] [ user ] [ cpu ] [ dsa ] [ dsa ] [ cpu ] [ user ] [ user ]
[ ] [ ] [ x ] [ ] ---- [ x ] [ ] [ ] [ ]
With the patch, the host MDB notifier on sw0p0 matches only on the local
switch, which is what we want for a termination plane address.
| |
sw0p0 sw0p1 sw0p2 sw0p3 sw1p3 sw1p2 sw1p1 sw1p0
[ user ] [ user ] [ cpu ] [ dsa ] [ dsa ] [ cpu ] [ user ] [ user ]
[ ] [ ] [ x ] [ ] ---- [ ] [ ] [ ] [ ]
Name this new matching function "dsa_switch_host_address_match" since we
will be reusing it soon for host FDB entries as well.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-06-29 14:06:49 +00:00
|
|
|
{
|
net: dsa: make cross-chip notifiers more efficient for host events
To determine whether a given port should react to the port targeted by
the notifier, dsa_port_host_vlan_match() and dsa_port_host_address_match()
look at the positioning of the switch port currently executing the
notifier relative to the switch port for which the notifier was emitted.
To maintain stylistic compatibility with the other match functions from
switch.c, the host address and host VLAN match functions take the
notifier information about targeted port, switch and tree indices as
argument. However, these functions only use that information to retrieve
the struct dsa_port *targeted_dp, which is an invariant for the outer
loop that calls them. So it makes more sense to calculate the targeted
dp only once, and pass it to them as argument.
But furthermore, the targeted dp is actually known at the time the call
to dsa_port_notify() is made. It is just that we decide to only save the
indices of the port, switch and tree in the notifier structure, just to
retrace our steps and find the dp again using dsa_switch_find() and
dsa_to_port().
But both the above functions are relatively expensive, since they need
to iterate through lists. It appears more straightforward to make all
notifiers just pass the targeted dp inside their info structure, and
have the code that needs the indices to look at info->dp->index instead
of info->port, or info->dp->ds->index instead of info->sw_index, or
info->dp->ds->dst->index instead of info->tree_index.
For the sake of consistency, all cross-chip notifiers are converted to
pass the "dp" directly.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-04-15 15:46:22 +00:00
|
|
|
struct dsa_port *cpu_dp = targeted_dp->cpu_dp;
|
net: dsa: introduce a separate cross-chip notifier type for host MDBs
Commit abd49535c380 ("net: dsa: execute dsa_switch_mdb_add only for
routing port in cross-chip topologies") does a surprisingly good job
even for the SWITCHDEV_OBJ_ID_HOST_MDB use case, where DSA simply
translates a switchdev object received on dp into a cross-chip notifier
for dp->cpu_dp.
To visualize how that works, imagine the daisy chain topology below and
consider a SWITCHDEV_OBJ_ID_HOST_MDB object emitted on sw2p0. How does
the cross-chip notifier know to match on all the right ports (sw0p4, the
dedicated CPU port, sw1p4, an upstream DSA link, and sw2p4, another
upstream DSA link)?
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ ] [ ] [ ] [ ] [ x ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
The answer is simple: the dedicated CPU port of sw2p0 is sw0p4, and
dsa_routing_port returns the upstream port for all switches.
That is fine, but there are other topologies where this does not work as
well. There are trees with "H" topologies in the wild, where there are 2
or more switches with DSA links between them, but every switch has its
dedicated CPU port. For these topologies, it seems stupid for the neighbor
switches to install an MDB entry on the routing port, since these
multicast addresses are fundamentally different than the usual ones we
support (and that is the justification for this patch, to introduce the
concept of a termination plane multicast MAC address, as opposed to a
forwarding plane multicast MAC address).
For example, when a SWITCHDEV_OBJ_ID_HOST_MDB would get added to sw0p0,
without this patch, it would get treated as a regular port MDB on sw0p2
and it would match on the ports below (including the sw1p3 routing port).
| |
sw0p0 sw0p1 sw0p2 sw0p3 sw1p3 sw1p2 sw1p1 sw1p0
[ user ] [ user ] [ cpu ] [ dsa ] [ dsa ] [ cpu ] [ user ] [ user ]
[ ] [ ] [ x ] [ ] ---- [ x ] [ ] [ ] [ ]
With the patch, the host MDB notifier on sw0p0 matches only on the local
switch, which is what we want for a termination plane address.
| |
sw0p0 sw0p1 sw0p2 sw0p3 sw1p3 sw1p2 sw1p1 sw1p0
[ user ] [ user ] [ cpu ] [ dsa ] [ dsa ] [ cpu ] [ user ] [ user ]
[ ] [ ] [ x ] [ ] ---- [ ] [ ] [ ] [ ]
Name this new matching function "dsa_switch_host_address_match" since we
will be reusing it soon for host FDB entries as well.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-06-29 14:06:49 +00:00
|
|
|
|
net: dsa: make cross-chip notifiers more efficient for host events
To determine whether a given port should react to the port targeted by
the notifier, dsa_port_host_vlan_match() and dsa_port_host_address_match()
look at the positioning of the switch port currently executing the
notifier relative to the switch port for which the notifier was emitted.
To maintain stylistic compatibility with the other match functions from
switch.c, the host address and host VLAN match functions take the
notifier information about targeted port, switch and tree indices as
argument. However, these functions only use that information to retrieve
the struct dsa_port *targeted_dp, which is an invariant for the outer
loop that calls them. So it makes more sense to calculate the targeted
dp only once, and pass it to them as argument.
But furthermore, the targeted dp is actually known at the time the call
to dsa_port_notify() is made. It is just that we decide to only save the
indices of the port, switch and tree in the notifier structure, just to
retrace our steps and find the dp again using dsa_switch_find() and
dsa_to_port().
But both the above functions are relatively expensive, since they need
to iterate through lists. It appears more straightforward to make all
notifiers just pass the targeted dp inside their info structure, and
have the code that needs the indices to look at info->dp->index instead
of info->port, or info->dp->ds->index instead of info->sw_index, or
info->dp->ds->dst->index instead of info->tree_index.
For the sake of consistency, all cross-chip notifiers are converted to
pass the "dp" directly.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-04-15 15:46:22 +00:00
|
|
|
if (dsa_switch_is_upstream_of(dp->ds, targeted_dp->ds))
|
2021-10-20 17:49:53 +00:00
|
|
|
return dp->index == dsa_towards_port(dp->ds, cpu_dp->ds->index,
|
|
|
|
cpu_dp->index);
|
net: dsa: introduce a separate cross-chip notifier type for host MDBs
Commit abd49535c380 ("net: dsa: execute dsa_switch_mdb_add only for
routing port in cross-chip topologies") does a surprisingly good job
even for the SWITCHDEV_OBJ_ID_HOST_MDB use case, where DSA simply
translates a switchdev object received on dp into a cross-chip notifier
for dp->cpu_dp.
To visualize how that works, imagine the daisy chain topology below and
consider a SWITCHDEV_OBJ_ID_HOST_MDB object emitted on sw2p0. How does
the cross-chip notifier know to match on all the right ports (sw0p4, the
dedicated CPU port, sw1p4, an upstream DSA link, and sw2p4, another
upstream DSA link)?
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ ] [ ] [ ] [ ] [ x ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
The answer is simple: the dedicated CPU port of sw2p0 is sw0p4, and
dsa_routing_port returns the upstream port for all switches.
That is fine, but there are other topologies where this does not work as
well. There are trees with "H" topologies in the wild, where there are 2
or more switches with DSA links between them, but every switch has its
dedicated CPU port. For these topologies, it seems stupid for the neighbor
switches to install an MDB entry on the routing port, since these
multicast addresses are fundamentally different than the usual ones we
support (and that is the justification for this patch, to introduce the
concept of a termination plane multicast MAC address, as opposed to a
forwarding plane multicast MAC address).
For example, when a SWITCHDEV_OBJ_ID_HOST_MDB would get added to sw0p0,
without this patch, it would get treated as a regular port MDB on sw0p2
and it would match on the ports below (including the sw1p3 routing port).
| |
sw0p0 sw0p1 sw0p2 sw0p3 sw1p3 sw1p2 sw1p1 sw1p0
[ user ] [ user ] [ cpu ] [ dsa ] [ dsa ] [ cpu ] [ user ] [ user ]
[ ] [ ] [ x ] [ ] ---- [ x ] [ ] [ ] [ ]
With the patch, the host MDB notifier on sw0p0 matches only on the local
switch, which is what we want for a termination plane address.
| |
sw0p0 sw0p1 sw0p2 sw0p3 sw1p3 sw1p2 sw1p1 sw1p0
[ user ] [ user ] [ cpu ] [ dsa ] [ dsa ] [ cpu ] [ user ] [ user ]
[ ] [ ] [ x ] [ ] ---- [ ] [ ] [ ] [ ]
Name this new matching function "dsa_switch_host_address_match" since we
will be reusing it soon for host FDB entries as well.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-06-29 14:06:49 +00:00
|
|
|
|
|
|
|
return false;
|
|
|
|
}
|
|
|
|
|
net: dsa: reference count the MDB entries at the cross-chip notifier level
Ever since the cross-chip notifiers were introduced, the design was
meant to be simplistic and just get the job done without worrying too
much about dangling resources left behind.
For example, somebody installs an MDB entry on sw0p0 in this daisy chain
topology. It gets installed using ds->ops->port_mdb_add() on sw0p0,
sw1p4 and sw2p4.
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ x ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
Then the same person deletes that MDB entry. The cross-chip notifier for
deletion only matches sw0p0:
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ x ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ ]
Why?
Because the DSA links are 'trunk' ports, if we just go ahead and delete
the MDB from sw1p4 and sw2p4 directly, we might delete those multicast
entries when they are still needed. Just consider the fact that somebody
does:
- add a multicast MAC address towards sw0p0 [ via the cross-chip
notifiers it gets installed on the DSA links too ]
- add the same multicast MAC address towards sw0p1 (another port of that
same switch)
- delete the same multicast MAC address from sw0p0.
At this point, if we deleted the MAC address from the DSA links, it
would be flooded, even though there is still an entry on switch 0 which
needs it not to.
So that is why deletions only match the targeted source port and nothing
on DSA links. Of course, dangling resources means that the hardware
tables will eventually run out given enough additions/removals, but hey,
at least it's simple.
But there is a bigger concern which needs to be addressed, and that is
our support for SWITCHDEV_OBJ_ID_HOST_MDB. DSA simply translates such an
object into a dsa_port_host_mdb_add() which ends up as ds->ops->port_mdb_add()
on the upstream port, and a similar thing happens on deletion:
dsa_port_host_mdb_del() will trigger ds->ops->port_mdb_del() on the
upstream port.
When there are 2 VLAN-unaware bridges spanning the same switch (which is
a use case DSA proudly supports), each bridge will install its own
SWITCHDEV_OBJ_ID_HOST_MDB entries. But upon deletion, DSA goes ahead and
emits a DSA_NOTIFIER_MDB_DEL for dp->cpu_dp, which is shared between the
user ports enslaved to br0 and the user ports enslaved to br1. Not good.
The host-trapped multicast addresses installed by br1 will be deleted
when any state changes in br0 (IGMP timers expire, or ports leave, etc).
To avoid this, we could of course go the route of the zero-sum game and
delete the DSA_NOTIFIER_MDB_DEL call for dp->cpu_dp. But the better
design is to just admit that on shared ports like DSA links and CPU
ports, we should be reference counting calls, even if this consumes some
dynamic memory which DSA has traditionally avoided. On the flip side,
the hardware tables of switches are limited in size, so it would be good
if the OS managed them properly instead of having them eventually
overflow.
To address the memory usage concern, we only apply the refcounting of
MDB entries on ports that are really shared (CPU ports and DSA links)
and not on user ports. In a typical single-switch setup, this means only
the CPU port (and the host MDB entries are not that many, really).
The name of the newly introduced data structures (dsa_mac_addr) is
chosen in such a way that will be reusable for host FDB entries (next
patch).
With this change, we can finally have the same matching logic for the
MDB additions and deletions, as well as for their host-trapped variants.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-06-29 14:06:50 +00:00
|
|
|
static struct dsa_mac_addr *dsa_mac_addr_find(struct list_head *addr_list,
|
net: dsa: request drivers to perform FDB isolation
For DSA, to encourage drivers to perform FDB isolation simply means to
track which bridge does each FDB and MDB entry belong to. It then
becomes the driver responsibility to use something that makes the FDB
entry from one bridge not match the FDB lookup of ports from other
bridges.
The top-level functions where the bridge is determined are:
- dsa_port_fdb_{add,del}
- dsa_port_host_fdb_{add,del}
- dsa_port_mdb_{add,del}
- dsa_port_host_mdb_{add,del}
aka the pre-crosschip-notifier functions.
Changing the API to pass a reference to a bridge is not superfluous, and
looking at the passed bridge argument is not the same as having the
driver look at dsa_to_port(ds, port)->bridge from the ->port_fdb_add()
method.
DSA installs FDB and MDB entries on shared (CPU and DSA) ports as well,
and those do not have any dp->bridge information to retrieve, because
they are not in any bridge - they are merely the pipes that serve the
user ports that are in one or multiple bridges.
The struct dsa_bridge associated with each FDB/MDB entry is encapsulated
in a larger "struct dsa_db" database. Although only databases associated
to bridges are notified for now, this API will be the starting point for
implementing IFF_UNICAST_FLT in DSA. There, the idea is to install FDB
entries on the CPU port which belong to the corresponding user port's
port database. These are supposed to match only when the port is
standalone.
It is better to introduce the API in its expected final form than to
introduce it for bridges first, then to have to change drivers which may
have made one or more assumptions.
Drivers can use the provided bridge.num, but they can also use a
different numbering scheme that is more convenient.
DSA must perform refcounting on the CPU and DSA ports by also taking
into account the bridge number. So if two bridges request the same local
address, DSA must notify the driver twice, once for each bridge.
In fact, if the driver supports FDB isolation, DSA must perform
refcounting per bridge, but if the driver doesn't, DSA must refcount
host addresses across all bridges, otherwise it would be telling the
driver to delete an FDB entry for a bridge and the driver would delete
it for all bridges. So introduce a bool fdb_isolation in drivers which
would make all bridge databases passed to the cross-chip notifier have
the same number (0). This makes dsa_mac_addr_find() -> dsa_db_equal()
say that all bridge databases are the same database - which is
essentially the legacy behavior.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-02-25 09:22:22 +00:00
|
|
|
const unsigned char *addr, u16 vid,
|
|
|
|
struct dsa_db db)
|
net: dsa: reference count the MDB entries at the cross-chip notifier level
Ever since the cross-chip notifiers were introduced, the design was
meant to be simplistic and just get the job done without worrying too
much about dangling resources left behind.
For example, somebody installs an MDB entry on sw0p0 in this daisy chain
topology. It gets installed using ds->ops->port_mdb_add() on sw0p0,
sw1p4 and sw2p4.
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ x ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
Then the same person deletes that MDB entry. The cross-chip notifier for
deletion only matches sw0p0:
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ x ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ ]
Why?
Because the DSA links are 'trunk' ports, if we just go ahead and delete
the MDB from sw1p4 and sw2p4 directly, we might delete those multicast
entries when they are still needed. Just consider the fact that somebody
does:
- add a multicast MAC address towards sw0p0 [ via the cross-chip
notifiers it gets installed on the DSA links too ]
- add the same multicast MAC address towards sw0p1 (another port of that
same switch)
- delete the same multicast MAC address from sw0p0.
At this point, if we deleted the MAC address from the DSA links, it
would be flooded, even though there is still an entry on switch 0 which
needs it not to.
So that is why deletions only match the targeted source port and nothing
on DSA links. Of course, dangling resources means that the hardware
tables will eventually run out given enough additions/removals, but hey,
at least it's simple.
But there is a bigger concern which needs to be addressed, and that is
our support for SWITCHDEV_OBJ_ID_HOST_MDB. DSA simply translates such an
object into a dsa_port_host_mdb_add() which ends up as ds->ops->port_mdb_add()
on the upstream port, and a similar thing happens on deletion:
dsa_port_host_mdb_del() will trigger ds->ops->port_mdb_del() on the
upstream port.
When there are 2 VLAN-unaware bridges spanning the same switch (which is
a use case DSA proudly supports), each bridge will install its own
SWITCHDEV_OBJ_ID_HOST_MDB entries. But upon deletion, DSA goes ahead and
emits a DSA_NOTIFIER_MDB_DEL for dp->cpu_dp, which is shared between the
user ports enslaved to br0 and the user ports enslaved to br1. Not good.
The host-trapped multicast addresses installed by br1 will be deleted
when any state changes in br0 (IGMP timers expire, or ports leave, etc).
To avoid this, we could of course go the route of the zero-sum game and
delete the DSA_NOTIFIER_MDB_DEL call for dp->cpu_dp. But the better
design is to just admit that on shared ports like DSA links and CPU
ports, we should be reference counting calls, even if this consumes some
dynamic memory which DSA has traditionally avoided. On the flip side,
the hardware tables of switches are limited in size, so it would be good
if the OS managed them properly instead of having them eventually
overflow.
To address the memory usage concern, we only apply the refcounting of
MDB entries on ports that are really shared (CPU ports and DSA links)
and not on user ports. In a typical single-switch setup, this means only
the CPU port (and the host MDB entries are not that many, really).
The name of the newly introduced data structures (dsa_mac_addr) is
chosen in such a way that will be reusable for host FDB entries (next
patch).
With this change, we can finally have the same matching logic for the
MDB additions and deletions, as well as for their host-trapped variants.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-06-29 14:06:50 +00:00
|
|
|
{
|
|
|
|
struct dsa_mac_addr *a;
|
|
|
|
|
|
|
|
list_for_each_entry(a, addr_list, list)
|
net: dsa: request drivers to perform FDB isolation
For DSA, to encourage drivers to perform FDB isolation simply means to
track which bridge does each FDB and MDB entry belong to. It then
becomes the driver responsibility to use something that makes the FDB
entry from one bridge not match the FDB lookup of ports from other
bridges.
The top-level functions where the bridge is determined are:
- dsa_port_fdb_{add,del}
- dsa_port_host_fdb_{add,del}
- dsa_port_mdb_{add,del}
- dsa_port_host_mdb_{add,del}
aka the pre-crosschip-notifier functions.
Changing the API to pass a reference to a bridge is not superfluous, and
looking at the passed bridge argument is not the same as having the
driver look at dsa_to_port(ds, port)->bridge from the ->port_fdb_add()
method.
DSA installs FDB and MDB entries on shared (CPU and DSA) ports as well,
and those do not have any dp->bridge information to retrieve, because
they are not in any bridge - they are merely the pipes that serve the
user ports that are in one or multiple bridges.
The struct dsa_bridge associated with each FDB/MDB entry is encapsulated
in a larger "struct dsa_db" database. Although only databases associated
to bridges are notified for now, this API will be the starting point for
implementing IFF_UNICAST_FLT in DSA. There, the idea is to install FDB
entries on the CPU port which belong to the corresponding user port's
port database. These are supposed to match only when the port is
standalone.
It is better to introduce the API in its expected final form than to
introduce it for bridges first, then to have to change drivers which may
have made one or more assumptions.
Drivers can use the provided bridge.num, but they can also use a
different numbering scheme that is more convenient.
DSA must perform refcounting on the CPU and DSA ports by also taking
into account the bridge number. So if two bridges request the same local
address, DSA must notify the driver twice, once for each bridge.
In fact, if the driver supports FDB isolation, DSA must perform
refcounting per bridge, but if the driver doesn't, DSA must refcount
host addresses across all bridges, otherwise it would be telling the
driver to delete an FDB entry for a bridge and the driver would delete
it for all bridges. So introduce a bool fdb_isolation in drivers which
would make all bridge databases passed to the cross-chip notifier have
the same number (0). This makes dsa_mac_addr_find() -> dsa_db_equal()
say that all bridge databases are the same database - which is
essentially the legacy behavior.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-02-25 09:22:22 +00:00
|
|
|
if (ether_addr_equal(a->addr, addr) && a->vid == vid &&
|
|
|
|
dsa_db_equal(&a->db, &db))
|
net: dsa: reference count the MDB entries at the cross-chip notifier level
Ever since the cross-chip notifiers were introduced, the design was
meant to be simplistic and just get the job done without worrying too
much about dangling resources left behind.
For example, somebody installs an MDB entry on sw0p0 in this daisy chain
topology. It gets installed using ds->ops->port_mdb_add() on sw0p0,
sw1p4 and sw2p4.
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ x ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
Then the same person deletes that MDB entry. The cross-chip notifier for
deletion only matches sw0p0:
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ x ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ ]
Why?
Because the DSA links are 'trunk' ports, if we just go ahead and delete
the MDB from sw1p4 and sw2p4 directly, we might delete those multicast
entries when they are still needed. Just consider the fact that somebody
does:
- add a multicast MAC address towards sw0p0 [ via the cross-chip
notifiers it gets installed on the DSA links too ]
- add the same multicast MAC address towards sw0p1 (another port of that
same switch)
- delete the same multicast MAC address from sw0p0.
At this point, if we deleted the MAC address from the DSA links, it
would be flooded, even though there is still an entry on switch 0 which
needs it not to.
So that is why deletions only match the targeted source port and nothing
on DSA links. Of course, dangling resources means that the hardware
tables will eventually run out given enough additions/removals, but hey,
at least it's simple.
But there is a bigger concern which needs to be addressed, and that is
our support for SWITCHDEV_OBJ_ID_HOST_MDB. DSA simply translates such an
object into a dsa_port_host_mdb_add() which ends up as ds->ops->port_mdb_add()
on the upstream port, and a similar thing happens on deletion:
dsa_port_host_mdb_del() will trigger ds->ops->port_mdb_del() on the
upstream port.
When there are 2 VLAN-unaware bridges spanning the same switch (which is
a use case DSA proudly supports), each bridge will install its own
SWITCHDEV_OBJ_ID_HOST_MDB entries. But upon deletion, DSA goes ahead and
emits a DSA_NOTIFIER_MDB_DEL for dp->cpu_dp, which is shared between the
user ports enslaved to br0 and the user ports enslaved to br1. Not good.
The host-trapped multicast addresses installed by br1 will be deleted
when any state changes in br0 (IGMP timers expire, or ports leave, etc).
To avoid this, we could of course go the route of the zero-sum game and
delete the DSA_NOTIFIER_MDB_DEL call for dp->cpu_dp. But the better
design is to just admit that on shared ports like DSA links and CPU
ports, we should be reference counting calls, even if this consumes some
dynamic memory which DSA has traditionally avoided. On the flip side,
the hardware tables of switches are limited in size, so it would be good
if the OS managed them properly instead of having them eventually
overflow.
To address the memory usage concern, we only apply the refcounting of
MDB entries on ports that are really shared (CPU ports and DSA links)
and not on user ports. In a typical single-switch setup, this means only
the CPU port (and the host MDB entries are not that many, really).
The name of the newly introduced data structures (dsa_mac_addr) is
chosen in such a way that will be reusable for host FDB entries (next
patch).
With this change, we can finally have the same matching logic for the
MDB additions and deletions, as well as for their host-trapped variants.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-06-29 14:06:50 +00:00
|
|
|
return a;
|
|
|
|
|
|
|
|
return NULL;
|
|
|
|
}
|
|
|
|
|
2021-10-20 17:49:53 +00:00
|
|
|
static int dsa_port_do_mdb_add(struct dsa_port *dp,
|
net: dsa: request drivers to perform FDB isolation
For DSA, to encourage drivers to perform FDB isolation simply means to
track which bridge does each FDB and MDB entry belong to. It then
becomes the driver responsibility to use something that makes the FDB
entry from one bridge not match the FDB lookup of ports from other
bridges.
The top-level functions where the bridge is determined are:
- dsa_port_fdb_{add,del}
- dsa_port_host_fdb_{add,del}
- dsa_port_mdb_{add,del}
- dsa_port_host_mdb_{add,del}
aka the pre-crosschip-notifier functions.
Changing the API to pass a reference to a bridge is not superfluous, and
looking at the passed bridge argument is not the same as having the
driver look at dsa_to_port(ds, port)->bridge from the ->port_fdb_add()
method.
DSA installs FDB and MDB entries on shared (CPU and DSA) ports as well,
and those do not have any dp->bridge information to retrieve, because
they are not in any bridge - they are merely the pipes that serve the
user ports that are in one or multiple bridges.
The struct dsa_bridge associated with each FDB/MDB entry is encapsulated
in a larger "struct dsa_db" database. Although only databases associated
to bridges are notified for now, this API will be the starting point for
implementing IFF_UNICAST_FLT in DSA. There, the idea is to install FDB
entries on the CPU port which belong to the corresponding user port's
port database. These are supposed to match only when the port is
standalone.
It is better to introduce the API in its expected final form than to
introduce it for bridges first, then to have to change drivers which may
have made one or more assumptions.
Drivers can use the provided bridge.num, but they can also use a
different numbering scheme that is more convenient.
DSA must perform refcounting on the CPU and DSA ports by also taking
into account the bridge number. So if two bridges request the same local
address, DSA must notify the driver twice, once for each bridge.
In fact, if the driver supports FDB isolation, DSA must perform
refcounting per bridge, but if the driver doesn't, DSA must refcount
host addresses across all bridges, otherwise it would be telling the
driver to delete an FDB entry for a bridge and the driver would delete
it for all bridges. So introduce a bool fdb_isolation in drivers which
would make all bridge databases passed to the cross-chip notifier have
the same number (0). This makes dsa_mac_addr_find() -> dsa_db_equal()
say that all bridge databases are the same database - which is
essentially the legacy behavior.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-02-25 09:22:22 +00:00
|
|
|
const struct switchdev_obj_port_mdb *mdb,
|
|
|
|
struct dsa_db db)
|
net: dsa: reference count the MDB entries at the cross-chip notifier level
Ever since the cross-chip notifiers were introduced, the design was
meant to be simplistic and just get the job done without worrying too
much about dangling resources left behind.
For example, somebody installs an MDB entry on sw0p0 in this daisy chain
topology. It gets installed using ds->ops->port_mdb_add() on sw0p0,
sw1p4 and sw2p4.
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ x ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
Then the same person deletes that MDB entry. The cross-chip notifier for
deletion only matches sw0p0:
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ x ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ ]
Why?
Because the DSA links are 'trunk' ports, if we just go ahead and delete
the MDB from sw1p4 and sw2p4 directly, we might delete those multicast
entries when they are still needed. Just consider the fact that somebody
does:
- add a multicast MAC address towards sw0p0 [ via the cross-chip
notifiers it gets installed on the DSA links too ]
- add the same multicast MAC address towards sw0p1 (another port of that
same switch)
- delete the same multicast MAC address from sw0p0.
At this point, if we deleted the MAC address from the DSA links, it
would be flooded, even though there is still an entry on switch 0 which
needs it not to.
So that is why deletions only match the targeted source port and nothing
on DSA links. Of course, dangling resources means that the hardware
tables will eventually run out given enough additions/removals, but hey,
at least it's simple.
But there is a bigger concern which needs to be addressed, and that is
our support for SWITCHDEV_OBJ_ID_HOST_MDB. DSA simply translates such an
object into a dsa_port_host_mdb_add() which ends up as ds->ops->port_mdb_add()
on the upstream port, and a similar thing happens on deletion:
dsa_port_host_mdb_del() will trigger ds->ops->port_mdb_del() on the
upstream port.
When there are 2 VLAN-unaware bridges spanning the same switch (which is
a use case DSA proudly supports), each bridge will install its own
SWITCHDEV_OBJ_ID_HOST_MDB entries. But upon deletion, DSA goes ahead and
emits a DSA_NOTIFIER_MDB_DEL for dp->cpu_dp, which is shared between the
user ports enslaved to br0 and the user ports enslaved to br1. Not good.
The host-trapped multicast addresses installed by br1 will be deleted
when any state changes in br0 (IGMP timers expire, or ports leave, etc).
To avoid this, we could of course go the route of the zero-sum game and
delete the DSA_NOTIFIER_MDB_DEL call for dp->cpu_dp. But the better
design is to just admit that on shared ports like DSA links and CPU
ports, we should be reference counting calls, even if this consumes some
dynamic memory which DSA has traditionally avoided. On the flip side,
the hardware tables of switches are limited in size, so it would be good
if the OS managed them properly instead of having them eventually
overflow.
To address the memory usage concern, we only apply the refcounting of
MDB entries on ports that are really shared (CPU ports and DSA links)
and not on user ports. In a typical single-switch setup, this means only
the CPU port (and the host MDB entries are not that many, really).
The name of the newly introduced data structures (dsa_mac_addr) is
chosen in such a way that will be reusable for host FDB entries (next
patch).
With this change, we can finally have the same matching logic for the
MDB additions and deletions, as well as for their host-trapped variants.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-06-29 14:06:50 +00:00
|
|
|
{
|
2021-10-20 17:49:53 +00:00
|
|
|
struct dsa_switch *ds = dp->ds;
|
net: dsa: reference count the MDB entries at the cross-chip notifier level
Ever since the cross-chip notifiers were introduced, the design was
meant to be simplistic and just get the job done without worrying too
much about dangling resources left behind.
For example, somebody installs an MDB entry on sw0p0 in this daisy chain
topology. It gets installed using ds->ops->port_mdb_add() on sw0p0,
sw1p4 and sw2p4.
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ x ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
Then the same person deletes that MDB entry. The cross-chip notifier for
deletion only matches sw0p0:
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ x ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ ]
Why?
Because the DSA links are 'trunk' ports, if we just go ahead and delete
the MDB from sw1p4 and sw2p4 directly, we might delete those multicast
entries when they are still needed. Just consider the fact that somebody
does:
- add a multicast MAC address towards sw0p0 [ via the cross-chip
notifiers it gets installed on the DSA links too ]
- add the same multicast MAC address towards sw0p1 (another port of that
same switch)
- delete the same multicast MAC address from sw0p0.
At this point, if we deleted the MAC address from the DSA links, it
would be flooded, even though there is still an entry on switch 0 which
needs it not to.
So that is why deletions only match the targeted source port and nothing
on DSA links. Of course, dangling resources means that the hardware
tables will eventually run out given enough additions/removals, but hey,
at least it's simple.
But there is a bigger concern which needs to be addressed, and that is
our support for SWITCHDEV_OBJ_ID_HOST_MDB. DSA simply translates such an
object into a dsa_port_host_mdb_add() which ends up as ds->ops->port_mdb_add()
on the upstream port, and a similar thing happens on deletion:
dsa_port_host_mdb_del() will trigger ds->ops->port_mdb_del() on the
upstream port.
When there are 2 VLAN-unaware bridges spanning the same switch (which is
a use case DSA proudly supports), each bridge will install its own
SWITCHDEV_OBJ_ID_HOST_MDB entries. But upon deletion, DSA goes ahead and
emits a DSA_NOTIFIER_MDB_DEL for dp->cpu_dp, which is shared between the
user ports enslaved to br0 and the user ports enslaved to br1. Not good.
The host-trapped multicast addresses installed by br1 will be deleted
when any state changes in br0 (IGMP timers expire, or ports leave, etc).
To avoid this, we could of course go the route of the zero-sum game and
delete the DSA_NOTIFIER_MDB_DEL call for dp->cpu_dp. But the better
design is to just admit that on shared ports like DSA links and CPU
ports, we should be reference counting calls, even if this consumes some
dynamic memory which DSA has traditionally avoided. On the flip side,
the hardware tables of switches are limited in size, so it would be good
if the OS managed them properly instead of having them eventually
overflow.
To address the memory usage concern, we only apply the refcounting of
MDB entries on ports that are really shared (CPU ports and DSA links)
and not on user ports. In a typical single-switch setup, this means only
the CPU port (and the host MDB entries are not that many, really).
The name of the newly introduced data structures (dsa_mac_addr) is
chosen in such a way that will be reusable for host FDB entries (next
patch).
With this change, we can finally have the same matching logic for the
MDB additions and deletions, as well as for their host-trapped variants.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-06-29 14:06:50 +00:00
|
|
|
struct dsa_mac_addr *a;
|
2021-10-20 17:49:53 +00:00
|
|
|
int port = dp->index;
|
net: dsa: introduce locking for the address lists on CPU and DSA ports
Now that the rtnl_mutex is going away for dsa_port_{host_,}fdb_{add,del},
no one is serializing access to the address lists that DSA keeps for the
purpose of reference counting on shared ports (CPU and cascade ports).
It can happen for one dsa_switch_do_fdb_del to do list_del on a dp->fdbs
element while another dsa_switch_do_fdb_{add,del} is traversing dp->fdbs.
We need to avoid that.
Currently dp->mdbs is not at risk, because dsa_switch_do_mdb_{add,del}
still runs under the rtnl_mutex. But it would be nice if it would not
depend on that being the case. So let's introduce a mutex per port (the
address lists are per port too) and share it between dp->mdbs and
dp->fdbs.
The place where we put the locking is interesting. It could be tempting
to put a DSA-level lock which still serializes calls to
.port_fdb_{add,del}, but it would still not avoid concurrency with other
driver code paths that are currently under rtnl_mutex (.port_fdb_dump,
.port_fast_age). So it would add a very false sense of security (and
adding a global switch-wide lock in DSA to resynchronize with the
rtnl_lock is also counterproductive and hard).
So the locking is intentionally done only where the dp->fdbs and dp->mdbs
lists are traversed. That means, from a driver perspective, that
.port_fdb_add will be called with the dp->addr_lists_lock mutex held on
the CPU port, but not held on user ports. This is done so that driver
writers are not encouraged to rely on any guarantee offered by
dp->addr_lists_lock.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-10-24 17:17:54 +00:00
|
|
|
int err = 0;
|
net: dsa: reference count the MDB entries at the cross-chip notifier level
Ever since the cross-chip notifiers were introduced, the design was
meant to be simplistic and just get the job done without worrying too
much about dangling resources left behind.
For example, somebody installs an MDB entry on sw0p0 in this daisy chain
topology. It gets installed using ds->ops->port_mdb_add() on sw0p0,
sw1p4 and sw2p4.
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ x ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
Then the same person deletes that MDB entry. The cross-chip notifier for
deletion only matches sw0p0:
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ x ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ ]
Why?
Because the DSA links are 'trunk' ports, if we just go ahead and delete
the MDB from sw1p4 and sw2p4 directly, we might delete those multicast
entries when they are still needed. Just consider the fact that somebody
does:
- add a multicast MAC address towards sw0p0 [ via the cross-chip
notifiers it gets installed on the DSA links too ]
- add the same multicast MAC address towards sw0p1 (another port of that
same switch)
- delete the same multicast MAC address from sw0p0.
At this point, if we deleted the MAC address from the DSA links, it
would be flooded, even though there is still an entry on switch 0 which
needs it not to.
So that is why deletions only match the targeted source port and nothing
on DSA links. Of course, dangling resources means that the hardware
tables will eventually run out given enough additions/removals, but hey,
at least it's simple.
But there is a bigger concern which needs to be addressed, and that is
our support for SWITCHDEV_OBJ_ID_HOST_MDB. DSA simply translates such an
object into a dsa_port_host_mdb_add() which ends up as ds->ops->port_mdb_add()
on the upstream port, and a similar thing happens on deletion:
dsa_port_host_mdb_del() will trigger ds->ops->port_mdb_del() on the
upstream port.
When there are 2 VLAN-unaware bridges spanning the same switch (which is
a use case DSA proudly supports), each bridge will install its own
SWITCHDEV_OBJ_ID_HOST_MDB entries. But upon deletion, DSA goes ahead and
emits a DSA_NOTIFIER_MDB_DEL for dp->cpu_dp, which is shared between the
user ports enslaved to br0 and the user ports enslaved to br1. Not good.
The host-trapped multicast addresses installed by br1 will be deleted
when any state changes in br0 (IGMP timers expire, or ports leave, etc).
To avoid this, we could of course go the route of the zero-sum game and
delete the DSA_NOTIFIER_MDB_DEL call for dp->cpu_dp. But the better
design is to just admit that on shared ports like DSA links and CPU
ports, we should be reference counting calls, even if this consumes some
dynamic memory which DSA has traditionally avoided. On the flip side,
the hardware tables of switches are limited in size, so it would be good
if the OS managed them properly instead of having them eventually
overflow.
To address the memory usage concern, we only apply the refcounting of
MDB entries on ports that are really shared (CPU ports and DSA links)
and not on user ports. In a typical single-switch setup, this means only
the CPU port (and the host MDB entries are not that many, really).
The name of the newly introduced data structures (dsa_mac_addr) is
chosen in such a way that will be reusable for host FDB entries (next
patch).
With this change, we can finally have the same matching logic for the
MDB additions and deletions, as well as for their host-trapped variants.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-06-29 14:06:50 +00:00
|
|
|
|
|
|
|
/* No need to bother with refcounting for user ports */
|
|
|
|
if (!(dsa_port_is_cpu(dp) || dsa_port_is_dsa(dp)))
|
net: dsa: request drivers to perform FDB isolation
For DSA, to encourage drivers to perform FDB isolation simply means to
track which bridge does each FDB and MDB entry belong to. It then
becomes the driver responsibility to use something that makes the FDB
entry from one bridge not match the FDB lookup of ports from other
bridges.
The top-level functions where the bridge is determined are:
- dsa_port_fdb_{add,del}
- dsa_port_host_fdb_{add,del}
- dsa_port_mdb_{add,del}
- dsa_port_host_mdb_{add,del}
aka the pre-crosschip-notifier functions.
Changing the API to pass a reference to a bridge is not superfluous, and
looking at the passed bridge argument is not the same as having the
driver look at dsa_to_port(ds, port)->bridge from the ->port_fdb_add()
method.
DSA installs FDB and MDB entries on shared (CPU and DSA) ports as well,
and those do not have any dp->bridge information to retrieve, because
they are not in any bridge - they are merely the pipes that serve the
user ports that are in one or multiple bridges.
The struct dsa_bridge associated with each FDB/MDB entry is encapsulated
in a larger "struct dsa_db" database. Although only databases associated
to bridges are notified for now, this API will be the starting point for
implementing IFF_UNICAST_FLT in DSA. There, the idea is to install FDB
entries on the CPU port which belong to the corresponding user port's
port database. These are supposed to match only when the port is
standalone.
It is better to introduce the API in its expected final form than to
introduce it for bridges first, then to have to change drivers which may
have made one or more assumptions.
Drivers can use the provided bridge.num, but they can also use a
different numbering scheme that is more convenient.
DSA must perform refcounting on the CPU and DSA ports by also taking
into account the bridge number. So if two bridges request the same local
address, DSA must notify the driver twice, once for each bridge.
In fact, if the driver supports FDB isolation, DSA must perform
refcounting per bridge, but if the driver doesn't, DSA must refcount
host addresses across all bridges, otherwise it would be telling the
driver to delete an FDB entry for a bridge and the driver would delete
it for all bridges. So introduce a bool fdb_isolation in drivers which
would make all bridge databases passed to the cross-chip notifier have
the same number (0). This makes dsa_mac_addr_find() -> dsa_db_equal()
say that all bridge databases are the same database - which is
essentially the legacy behavior.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-02-25 09:22:22 +00:00
|
|
|
return ds->ops->port_mdb_add(ds, port, mdb, db);
|
net: dsa: reference count the MDB entries at the cross-chip notifier level
Ever since the cross-chip notifiers were introduced, the design was
meant to be simplistic and just get the job done without worrying too
much about dangling resources left behind.
For example, somebody installs an MDB entry on sw0p0 in this daisy chain
topology. It gets installed using ds->ops->port_mdb_add() on sw0p0,
sw1p4 and sw2p4.
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ x ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
Then the same person deletes that MDB entry. The cross-chip notifier for
deletion only matches sw0p0:
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ x ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ ]
Why?
Because the DSA links are 'trunk' ports, if we just go ahead and delete
the MDB from sw1p4 and sw2p4 directly, we might delete those multicast
entries when they are still needed. Just consider the fact that somebody
does:
- add a multicast MAC address towards sw0p0 [ via the cross-chip
notifiers it gets installed on the DSA links too ]
- add the same multicast MAC address towards sw0p1 (another port of that
same switch)
- delete the same multicast MAC address from sw0p0.
At this point, if we deleted the MAC address from the DSA links, it
would be flooded, even though there is still an entry on switch 0 which
needs it not to.
So that is why deletions only match the targeted source port and nothing
on DSA links. Of course, dangling resources means that the hardware
tables will eventually run out given enough additions/removals, but hey,
at least it's simple.
But there is a bigger concern which needs to be addressed, and that is
our support for SWITCHDEV_OBJ_ID_HOST_MDB. DSA simply translates such an
object into a dsa_port_host_mdb_add() which ends up as ds->ops->port_mdb_add()
on the upstream port, and a similar thing happens on deletion:
dsa_port_host_mdb_del() will trigger ds->ops->port_mdb_del() on the
upstream port.
When there are 2 VLAN-unaware bridges spanning the same switch (which is
a use case DSA proudly supports), each bridge will install its own
SWITCHDEV_OBJ_ID_HOST_MDB entries. But upon deletion, DSA goes ahead and
emits a DSA_NOTIFIER_MDB_DEL for dp->cpu_dp, which is shared between the
user ports enslaved to br0 and the user ports enslaved to br1. Not good.
The host-trapped multicast addresses installed by br1 will be deleted
when any state changes in br0 (IGMP timers expire, or ports leave, etc).
To avoid this, we could of course go the route of the zero-sum game and
delete the DSA_NOTIFIER_MDB_DEL call for dp->cpu_dp. But the better
design is to just admit that on shared ports like DSA links and CPU
ports, we should be reference counting calls, even if this consumes some
dynamic memory which DSA has traditionally avoided. On the flip side,
the hardware tables of switches are limited in size, so it would be good
if the OS managed them properly instead of having them eventually
overflow.
To address the memory usage concern, we only apply the refcounting of
MDB entries on ports that are really shared (CPU ports and DSA links)
and not on user ports. In a typical single-switch setup, this means only
the CPU port (and the host MDB entries are not that many, really).
The name of the newly introduced data structures (dsa_mac_addr) is
chosen in such a way that will be reusable for host FDB entries (next
patch).
With this change, we can finally have the same matching logic for the
MDB additions and deletions, as well as for their host-trapped variants.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-06-29 14:06:50 +00:00
|
|
|
|
net: dsa: introduce locking for the address lists on CPU and DSA ports
Now that the rtnl_mutex is going away for dsa_port_{host_,}fdb_{add,del},
no one is serializing access to the address lists that DSA keeps for the
purpose of reference counting on shared ports (CPU and cascade ports).
It can happen for one dsa_switch_do_fdb_del to do list_del on a dp->fdbs
element while another dsa_switch_do_fdb_{add,del} is traversing dp->fdbs.
We need to avoid that.
Currently dp->mdbs is not at risk, because dsa_switch_do_mdb_{add,del}
still runs under the rtnl_mutex. But it would be nice if it would not
depend on that being the case. So let's introduce a mutex per port (the
address lists are per port too) and share it between dp->mdbs and
dp->fdbs.
The place where we put the locking is interesting. It could be tempting
to put a DSA-level lock which still serializes calls to
.port_fdb_{add,del}, but it would still not avoid concurrency with other
driver code paths that are currently under rtnl_mutex (.port_fdb_dump,
.port_fast_age). So it would add a very false sense of security (and
adding a global switch-wide lock in DSA to resynchronize with the
rtnl_lock is also counterproductive and hard).
So the locking is intentionally done only where the dp->fdbs and dp->mdbs
lists are traversed. That means, from a driver perspective, that
.port_fdb_add will be called with the dp->addr_lists_lock mutex held on
the CPU port, but not held on user ports. This is done so that driver
writers are not encouraged to rely on any guarantee offered by
dp->addr_lists_lock.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-10-24 17:17:54 +00:00
|
|
|
mutex_lock(&dp->addr_lists_lock);
|
|
|
|
|
net: dsa: request drivers to perform FDB isolation
For DSA, to encourage drivers to perform FDB isolation simply means to
track which bridge does each FDB and MDB entry belong to. It then
becomes the driver responsibility to use something that makes the FDB
entry from one bridge not match the FDB lookup of ports from other
bridges.
The top-level functions where the bridge is determined are:
- dsa_port_fdb_{add,del}
- dsa_port_host_fdb_{add,del}
- dsa_port_mdb_{add,del}
- dsa_port_host_mdb_{add,del}
aka the pre-crosschip-notifier functions.
Changing the API to pass a reference to a bridge is not superfluous, and
looking at the passed bridge argument is not the same as having the
driver look at dsa_to_port(ds, port)->bridge from the ->port_fdb_add()
method.
DSA installs FDB and MDB entries on shared (CPU and DSA) ports as well,
and those do not have any dp->bridge information to retrieve, because
they are not in any bridge - they are merely the pipes that serve the
user ports that are in one or multiple bridges.
The struct dsa_bridge associated with each FDB/MDB entry is encapsulated
in a larger "struct dsa_db" database. Although only databases associated
to bridges are notified for now, this API will be the starting point for
implementing IFF_UNICAST_FLT in DSA. There, the idea is to install FDB
entries on the CPU port which belong to the corresponding user port's
port database. These are supposed to match only when the port is
standalone.
It is better to introduce the API in its expected final form than to
introduce it for bridges first, then to have to change drivers which may
have made one or more assumptions.
Drivers can use the provided bridge.num, but they can also use a
different numbering scheme that is more convenient.
DSA must perform refcounting on the CPU and DSA ports by also taking
into account the bridge number. So if two bridges request the same local
address, DSA must notify the driver twice, once for each bridge.
In fact, if the driver supports FDB isolation, DSA must perform
refcounting per bridge, but if the driver doesn't, DSA must refcount
host addresses across all bridges, otherwise it would be telling the
driver to delete an FDB entry for a bridge and the driver would delete
it for all bridges. So introduce a bool fdb_isolation in drivers which
would make all bridge databases passed to the cross-chip notifier have
the same number (0). This makes dsa_mac_addr_find() -> dsa_db_equal()
say that all bridge databases are the same database - which is
essentially the legacy behavior.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-02-25 09:22:22 +00:00
|
|
|
a = dsa_mac_addr_find(&dp->mdbs, mdb->addr, mdb->vid, db);
|
net: dsa: reference count the MDB entries at the cross-chip notifier level
Ever since the cross-chip notifiers were introduced, the design was
meant to be simplistic and just get the job done without worrying too
much about dangling resources left behind.
For example, somebody installs an MDB entry on sw0p0 in this daisy chain
topology. It gets installed using ds->ops->port_mdb_add() on sw0p0,
sw1p4 and sw2p4.
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ x ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
Then the same person deletes that MDB entry. The cross-chip notifier for
deletion only matches sw0p0:
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ x ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ ]
Why?
Because the DSA links are 'trunk' ports, if we just go ahead and delete
the MDB from sw1p4 and sw2p4 directly, we might delete those multicast
entries when they are still needed. Just consider the fact that somebody
does:
- add a multicast MAC address towards sw0p0 [ via the cross-chip
notifiers it gets installed on the DSA links too ]
- add the same multicast MAC address towards sw0p1 (another port of that
same switch)
- delete the same multicast MAC address from sw0p0.
At this point, if we deleted the MAC address from the DSA links, it
would be flooded, even though there is still an entry on switch 0 which
needs it not to.
So that is why deletions only match the targeted source port and nothing
on DSA links. Of course, dangling resources means that the hardware
tables will eventually run out given enough additions/removals, but hey,
at least it's simple.
But there is a bigger concern which needs to be addressed, and that is
our support for SWITCHDEV_OBJ_ID_HOST_MDB. DSA simply translates such an
object into a dsa_port_host_mdb_add() which ends up as ds->ops->port_mdb_add()
on the upstream port, and a similar thing happens on deletion:
dsa_port_host_mdb_del() will trigger ds->ops->port_mdb_del() on the
upstream port.
When there are 2 VLAN-unaware bridges spanning the same switch (which is
a use case DSA proudly supports), each bridge will install its own
SWITCHDEV_OBJ_ID_HOST_MDB entries. But upon deletion, DSA goes ahead and
emits a DSA_NOTIFIER_MDB_DEL for dp->cpu_dp, which is shared between the
user ports enslaved to br0 and the user ports enslaved to br1. Not good.
The host-trapped multicast addresses installed by br1 will be deleted
when any state changes in br0 (IGMP timers expire, or ports leave, etc).
To avoid this, we could of course go the route of the zero-sum game and
delete the DSA_NOTIFIER_MDB_DEL call for dp->cpu_dp. But the better
design is to just admit that on shared ports like DSA links and CPU
ports, we should be reference counting calls, even if this consumes some
dynamic memory which DSA has traditionally avoided. On the flip side,
the hardware tables of switches are limited in size, so it would be good
if the OS managed them properly instead of having them eventually
overflow.
To address the memory usage concern, we only apply the refcounting of
MDB entries on ports that are really shared (CPU ports and DSA links)
and not on user ports. In a typical single-switch setup, this means only
the CPU port (and the host MDB entries are not that many, really).
The name of the newly introduced data structures (dsa_mac_addr) is
chosen in such a way that will be reusable for host FDB entries (next
patch).
With this change, we can finally have the same matching logic for the
MDB additions and deletions, as well as for their host-trapped variants.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-06-29 14:06:50 +00:00
|
|
|
if (a) {
|
|
|
|
refcount_inc(&a->refcount);
|
net: dsa: introduce locking for the address lists on CPU and DSA ports
Now that the rtnl_mutex is going away for dsa_port_{host_,}fdb_{add,del},
no one is serializing access to the address lists that DSA keeps for the
purpose of reference counting on shared ports (CPU and cascade ports).
It can happen for one dsa_switch_do_fdb_del to do list_del on a dp->fdbs
element while another dsa_switch_do_fdb_{add,del} is traversing dp->fdbs.
We need to avoid that.
Currently dp->mdbs is not at risk, because dsa_switch_do_mdb_{add,del}
still runs under the rtnl_mutex. But it would be nice if it would not
depend on that being the case. So let's introduce a mutex per port (the
address lists are per port too) and share it between dp->mdbs and
dp->fdbs.
The place where we put the locking is interesting. It could be tempting
to put a DSA-level lock which still serializes calls to
.port_fdb_{add,del}, but it would still not avoid concurrency with other
driver code paths that are currently under rtnl_mutex (.port_fdb_dump,
.port_fast_age). So it would add a very false sense of security (and
adding a global switch-wide lock in DSA to resynchronize with the
rtnl_lock is also counterproductive and hard).
So the locking is intentionally done only where the dp->fdbs and dp->mdbs
lists are traversed. That means, from a driver perspective, that
.port_fdb_add will be called with the dp->addr_lists_lock mutex held on
the CPU port, but not held on user ports. This is done so that driver
writers are not encouraged to rely on any guarantee offered by
dp->addr_lists_lock.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-10-24 17:17:54 +00:00
|
|
|
goto out;
|
net: dsa: reference count the MDB entries at the cross-chip notifier level
Ever since the cross-chip notifiers were introduced, the design was
meant to be simplistic and just get the job done without worrying too
much about dangling resources left behind.
For example, somebody installs an MDB entry on sw0p0 in this daisy chain
topology. It gets installed using ds->ops->port_mdb_add() on sw0p0,
sw1p4 and sw2p4.
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ x ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
Then the same person deletes that MDB entry. The cross-chip notifier for
deletion only matches sw0p0:
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ x ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ ]
Why?
Because the DSA links are 'trunk' ports, if we just go ahead and delete
the MDB from sw1p4 and sw2p4 directly, we might delete those multicast
entries when they are still needed. Just consider the fact that somebody
does:
- add a multicast MAC address towards sw0p0 [ via the cross-chip
notifiers it gets installed on the DSA links too ]
- add the same multicast MAC address towards sw0p1 (another port of that
same switch)
- delete the same multicast MAC address from sw0p0.
At this point, if we deleted the MAC address from the DSA links, it
would be flooded, even though there is still an entry on switch 0 which
needs it not to.
So that is why deletions only match the targeted source port and nothing
on DSA links. Of course, dangling resources means that the hardware
tables will eventually run out given enough additions/removals, but hey,
at least it's simple.
But there is a bigger concern which needs to be addressed, and that is
our support for SWITCHDEV_OBJ_ID_HOST_MDB. DSA simply translates such an
object into a dsa_port_host_mdb_add() which ends up as ds->ops->port_mdb_add()
on the upstream port, and a similar thing happens on deletion:
dsa_port_host_mdb_del() will trigger ds->ops->port_mdb_del() on the
upstream port.
When there are 2 VLAN-unaware bridges spanning the same switch (which is
a use case DSA proudly supports), each bridge will install its own
SWITCHDEV_OBJ_ID_HOST_MDB entries. But upon deletion, DSA goes ahead and
emits a DSA_NOTIFIER_MDB_DEL for dp->cpu_dp, which is shared between the
user ports enslaved to br0 and the user ports enslaved to br1. Not good.
The host-trapped multicast addresses installed by br1 will be deleted
when any state changes in br0 (IGMP timers expire, or ports leave, etc).
To avoid this, we could of course go the route of the zero-sum game and
delete the DSA_NOTIFIER_MDB_DEL call for dp->cpu_dp. But the better
design is to just admit that on shared ports like DSA links and CPU
ports, we should be reference counting calls, even if this consumes some
dynamic memory which DSA has traditionally avoided. On the flip side,
the hardware tables of switches are limited in size, so it would be good
if the OS managed them properly instead of having them eventually
overflow.
To address the memory usage concern, we only apply the refcounting of
MDB entries on ports that are really shared (CPU ports and DSA links)
and not on user ports. In a typical single-switch setup, this means only
the CPU port (and the host MDB entries are not that many, really).
The name of the newly introduced data structures (dsa_mac_addr) is
chosen in such a way that will be reusable for host FDB entries (next
patch).
With this change, we can finally have the same matching logic for the
MDB additions and deletions, as well as for their host-trapped variants.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-06-29 14:06:50 +00:00
|
|
|
}
|
|
|
|
|
|
|
|
a = kzalloc(sizeof(*a), GFP_KERNEL);
|
net: dsa: introduce locking for the address lists on CPU and DSA ports
Now that the rtnl_mutex is going away for dsa_port_{host_,}fdb_{add,del},
no one is serializing access to the address lists that DSA keeps for the
purpose of reference counting on shared ports (CPU and cascade ports).
It can happen for one dsa_switch_do_fdb_del to do list_del on a dp->fdbs
element while another dsa_switch_do_fdb_{add,del} is traversing dp->fdbs.
We need to avoid that.
Currently dp->mdbs is not at risk, because dsa_switch_do_mdb_{add,del}
still runs under the rtnl_mutex. But it would be nice if it would not
depend on that being the case. So let's introduce a mutex per port (the
address lists are per port too) and share it between dp->mdbs and
dp->fdbs.
The place where we put the locking is interesting. It could be tempting
to put a DSA-level lock which still serializes calls to
.port_fdb_{add,del}, but it would still not avoid concurrency with other
driver code paths that are currently under rtnl_mutex (.port_fdb_dump,
.port_fast_age). So it would add a very false sense of security (and
adding a global switch-wide lock in DSA to resynchronize with the
rtnl_lock is also counterproductive and hard).
So the locking is intentionally done only where the dp->fdbs and dp->mdbs
lists are traversed. That means, from a driver perspective, that
.port_fdb_add will be called with the dp->addr_lists_lock mutex held on
the CPU port, but not held on user ports. This is done so that driver
writers are not encouraged to rely on any guarantee offered by
dp->addr_lists_lock.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-10-24 17:17:54 +00:00
|
|
|
if (!a) {
|
|
|
|
err = -ENOMEM;
|
|
|
|
goto out;
|
|
|
|
}
|
net: dsa: reference count the MDB entries at the cross-chip notifier level
Ever since the cross-chip notifiers were introduced, the design was
meant to be simplistic and just get the job done without worrying too
much about dangling resources left behind.
For example, somebody installs an MDB entry on sw0p0 in this daisy chain
topology. It gets installed using ds->ops->port_mdb_add() on sw0p0,
sw1p4 and sw2p4.
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ x ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
Then the same person deletes that MDB entry. The cross-chip notifier for
deletion only matches sw0p0:
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ x ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ ]
Why?
Because the DSA links are 'trunk' ports, if we just go ahead and delete
the MDB from sw1p4 and sw2p4 directly, we might delete those multicast
entries when they are still needed. Just consider the fact that somebody
does:
- add a multicast MAC address towards sw0p0 [ via the cross-chip
notifiers it gets installed on the DSA links too ]
- add the same multicast MAC address towards sw0p1 (another port of that
same switch)
- delete the same multicast MAC address from sw0p0.
At this point, if we deleted the MAC address from the DSA links, it
would be flooded, even though there is still an entry on switch 0 which
needs it not to.
So that is why deletions only match the targeted source port and nothing
on DSA links. Of course, dangling resources means that the hardware
tables will eventually run out given enough additions/removals, but hey,
at least it's simple.
But there is a bigger concern which needs to be addressed, and that is
our support for SWITCHDEV_OBJ_ID_HOST_MDB. DSA simply translates such an
object into a dsa_port_host_mdb_add() which ends up as ds->ops->port_mdb_add()
on the upstream port, and a similar thing happens on deletion:
dsa_port_host_mdb_del() will trigger ds->ops->port_mdb_del() on the
upstream port.
When there are 2 VLAN-unaware bridges spanning the same switch (which is
a use case DSA proudly supports), each bridge will install its own
SWITCHDEV_OBJ_ID_HOST_MDB entries. But upon deletion, DSA goes ahead and
emits a DSA_NOTIFIER_MDB_DEL for dp->cpu_dp, which is shared between the
user ports enslaved to br0 and the user ports enslaved to br1. Not good.
The host-trapped multicast addresses installed by br1 will be deleted
when any state changes in br0 (IGMP timers expire, or ports leave, etc).
To avoid this, we could of course go the route of the zero-sum game and
delete the DSA_NOTIFIER_MDB_DEL call for dp->cpu_dp. But the better
design is to just admit that on shared ports like DSA links and CPU
ports, we should be reference counting calls, even if this consumes some
dynamic memory which DSA has traditionally avoided. On the flip side,
the hardware tables of switches are limited in size, so it would be good
if the OS managed them properly instead of having them eventually
overflow.
To address the memory usage concern, we only apply the refcounting of
MDB entries on ports that are really shared (CPU ports and DSA links)
and not on user ports. In a typical single-switch setup, this means only
the CPU port (and the host MDB entries are not that many, really).
The name of the newly introduced data structures (dsa_mac_addr) is
chosen in such a way that will be reusable for host FDB entries (next
patch).
With this change, we can finally have the same matching logic for the
MDB additions and deletions, as well as for their host-trapped variants.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-06-29 14:06:50 +00:00
|
|
|
|
net: dsa: request drivers to perform FDB isolation
For DSA, to encourage drivers to perform FDB isolation simply means to
track which bridge does each FDB and MDB entry belong to. It then
becomes the driver responsibility to use something that makes the FDB
entry from one bridge not match the FDB lookup of ports from other
bridges.
The top-level functions where the bridge is determined are:
- dsa_port_fdb_{add,del}
- dsa_port_host_fdb_{add,del}
- dsa_port_mdb_{add,del}
- dsa_port_host_mdb_{add,del}
aka the pre-crosschip-notifier functions.
Changing the API to pass a reference to a bridge is not superfluous, and
looking at the passed bridge argument is not the same as having the
driver look at dsa_to_port(ds, port)->bridge from the ->port_fdb_add()
method.
DSA installs FDB and MDB entries on shared (CPU and DSA) ports as well,
and those do not have any dp->bridge information to retrieve, because
they are not in any bridge - they are merely the pipes that serve the
user ports that are in one or multiple bridges.
The struct dsa_bridge associated with each FDB/MDB entry is encapsulated
in a larger "struct dsa_db" database. Although only databases associated
to bridges are notified for now, this API will be the starting point for
implementing IFF_UNICAST_FLT in DSA. There, the idea is to install FDB
entries on the CPU port which belong to the corresponding user port's
port database. These are supposed to match only when the port is
standalone.
It is better to introduce the API in its expected final form than to
introduce it for bridges first, then to have to change drivers which may
have made one or more assumptions.
Drivers can use the provided bridge.num, but they can also use a
different numbering scheme that is more convenient.
DSA must perform refcounting on the CPU and DSA ports by also taking
into account the bridge number. So if two bridges request the same local
address, DSA must notify the driver twice, once for each bridge.
In fact, if the driver supports FDB isolation, DSA must perform
refcounting per bridge, but if the driver doesn't, DSA must refcount
host addresses across all bridges, otherwise it would be telling the
driver to delete an FDB entry for a bridge and the driver would delete
it for all bridges. So introduce a bool fdb_isolation in drivers which
would make all bridge databases passed to the cross-chip notifier have
the same number (0). This makes dsa_mac_addr_find() -> dsa_db_equal()
say that all bridge databases are the same database - which is
essentially the legacy behavior.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-02-25 09:22:22 +00:00
|
|
|
err = ds->ops->port_mdb_add(ds, port, mdb, db);
|
net: dsa: reference count the MDB entries at the cross-chip notifier level
Ever since the cross-chip notifiers were introduced, the design was
meant to be simplistic and just get the job done without worrying too
much about dangling resources left behind.
For example, somebody installs an MDB entry on sw0p0 in this daisy chain
topology. It gets installed using ds->ops->port_mdb_add() on sw0p0,
sw1p4 and sw2p4.
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ x ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
Then the same person deletes that MDB entry. The cross-chip notifier for
deletion only matches sw0p0:
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ x ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ ]
Why?
Because the DSA links are 'trunk' ports, if we just go ahead and delete
the MDB from sw1p4 and sw2p4 directly, we might delete those multicast
entries when they are still needed. Just consider the fact that somebody
does:
- add a multicast MAC address towards sw0p0 [ via the cross-chip
notifiers it gets installed on the DSA links too ]
- add the same multicast MAC address towards sw0p1 (another port of that
same switch)
- delete the same multicast MAC address from sw0p0.
At this point, if we deleted the MAC address from the DSA links, it
would be flooded, even though there is still an entry on switch 0 which
needs it not to.
So that is why deletions only match the targeted source port and nothing
on DSA links. Of course, dangling resources means that the hardware
tables will eventually run out given enough additions/removals, but hey,
at least it's simple.
But there is a bigger concern which needs to be addressed, and that is
our support for SWITCHDEV_OBJ_ID_HOST_MDB. DSA simply translates such an
object into a dsa_port_host_mdb_add() which ends up as ds->ops->port_mdb_add()
on the upstream port, and a similar thing happens on deletion:
dsa_port_host_mdb_del() will trigger ds->ops->port_mdb_del() on the
upstream port.
When there are 2 VLAN-unaware bridges spanning the same switch (which is
a use case DSA proudly supports), each bridge will install its own
SWITCHDEV_OBJ_ID_HOST_MDB entries. But upon deletion, DSA goes ahead and
emits a DSA_NOTIFIER_MDB_DEL for dp->cpu_dp, which is shared between the
user ports enslaved to br0 and the user ports enslaved to br1. Not good.
The host-trapped multicast addresses installed by br1 will be deleted
when any state changes in br0 (IGMP timers expire, or ports leave, etc).
To avoid this, we could of course go the route of the zero-sum game and
delete the DSA_NOTIFIER_MDB_DEL call for dp->cpu_dp. But the better
design is to just admit that on shared ports like DSA links and CPU
ports, we should be reference counting calls, even if this consumes some
dynamic memory which DSA has traditionally avoided. On the flip side,
the hardware tables of switches are limited in size, so it would be good
if the OS managed them properly instead of having them eventually
overflow.
To address the memory usage concern, we only apply the refcounting of
MDB entries on ports that are really shared (CPU ports and DSA links)
and not on user ports. In a typical single-switch setup, this means only
the CPU port (and the host MDB entries are not that many, really).
The name of the newly introduced data structures (dsa_mac_addr) is
chosen in such a way that will be reusable for host FDB entries (next
patch).
With this change, we can finally have the same matching logic for the
MDB additions and deletions, as well as for their host-trapped variants.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-06-29 14:06:50 +00:00
|
|
|
if (err) {
|
|
|
|
kfree(a);
|
net: dsa: introduce locking for the address lists on CPU and DSA ports
Now that the rtnl_mutex is going away for dsa_port_{host_,}fdb_{add,del},
no one is serializing access to the address lists that DSA keeps for the
purpose of reference counting on shared ports (CPU and cascade ports).
It can happen for one dsa_switch_do_fdb_del to do list_del on a dp->fdbs
element while another dsa_switch_do_fdb_{add,del} is traversing dp->fdbs.
We need to avoid that.
Currently dp->mdbs is not at risk, because dsa_switch_do_mdb_{add,del}
still runs under the rtnl_mutex. But it would be nice if it would not
depend on that being the case. So let's introduce a mutex per port (the
address lists are per port too) and share it between dp->mdbs and
dp->fdbs.
The place where we put the locking is interesting. It could be tempting
to put a DSA-level lock which still serializes calls to
.port_fdb_{add,del}, but it would still not avoid concurrency with other
driver code paths that are currently under rtnl_mutex (.port_fdb_dump,
.port_fast_age). So it would add a very false sense of security (and
adding a global switch-wide lock in DSA to resynchronize with the
rtnl_lock is also counterproductive and hard).
So the locking is intentionally done only where the dp->fdbs and dp->mdbs
lists are traversed. That means, from a driver perspective, that
.port_fdb_add will be called with the dp->addr_lists_lock mutex held on
the CPU port, but not held on user ports. This is done so that driver
writers are not encouraged to rely on any guarantee offered by
dp->addr_lists_lock.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-10-24 17:17:54 +00:00
|
|
|
goto out;
|
net: dsa: reference count the MDB entries at the cross-chip notifier level
Ever since the cross-chip notifiers were introduced, the design was
meant to be simplistic and just get the job done without worrying too
much about dangling resources left behind.
For example, somebody installs an MDB entry on sw0p0 in this daisy chain
topology. It gets installed using ds->ops->port_mdb_add() on sw0p0,
sw1p4 and sw2p4.
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ x ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
Then the same person deletes that MDB entry. The cross-chip notifier for
deletion only matches sw0p0:
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ x ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ ]
Why?
Because the DSA links are 'trunk' ports, if we just go ahead and delete
the MDB from sw1p4 and sw2p4 directly, we might delete those multicast
entries when they are still needed. Just consider the fact that somebody
does:
- add a multicast MAC address towards sw0p0 [ via the cross-chip
notifiers it gets installed on the DSA links too ]
- add the same multicast MAC address towards sw0p1 (another port of that
same switch)
- delete the same multicast MAC address from sw0p0.
At this point, if we deleted the MAC address from the DSA links, it
would be flooded, even though there is still an entry on switch 0 which
needs it not to.
So that is why deletions only match the targeted source port and nothing
on DSA links. Of course, dangling resources means that the hardware
tables will eventually run out given enough additions/removals, but hey,
at least it's simple.
But there is a bigger concern which needs to be addressed, and that is
our support for SWITCHDEV_OBJ_ID_HOST_MDB. DSA simply translates such an
object into a dsa_port_host_mdb_add() which ends up as ds->ops->port_mdb_add()
on the upstream port, and a similar thing happens on deletion:
dsa_port_host_mdb_del() will trigger ds->ops->port_mdb_del() on the
upstream port.
When there are 2 VLAN-unaware bridges spanning the same switch (which is
a use case DSA proudly supports), each bridge will install its own
SWITCHDEV_OBJ_ID_HOST_MDB entries. But upon deletion, DSA goes ahead and
emits a DSA_NOTIFIER_MDB_DEL for dp->cpu_dp, which is shared between the
user ports enslaved to br0 and the user ports enslaved to br1. Not good.
The host-trapped multicast addresses installed by br1 will be deleted
when any state changes in br0 (IGMP timers expire, or ports leave, etc).
To avoid this, we could of course go the route of the zero-sum game and
delete the DSA_NOTIFIER_MDB_DEL call for dp->cpu_dp. But the better
design is to just admit that on shared ports like DSA links and CPU
ports, we should be reference counting calls, even if this consumes some
dynamic memory which DSA has traditionally avoided. On the flip side,
the hardware tables of switches are limited in size, so it would be good
if the OS managed them properly instead of having them eventually
overflow.
To address the memory usage concern, we only apply the refcounting of
MDB entries on ports that are really shared (CPU ports and DSA links)
and not on user ports. In a typical single-switch setup, this means only
the CPU port (and the host MDB entries are not that many, really).
The name of the newly introduced data structures (dsa_mac_addr) is
chosen in such a way that will be reusable for host FDB entries (next
patch).
With this change, we can finally have the same matching logic for the
MDB additions and deletions, as well as for their host-trapped variants.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-06-29 14:06:50 +00:00
|
|
|
}
|
|
|
|
|
|
|
|
ether_addr_copy(a->addr, mdb->addr);
|
|
|
|
a->vid = mdb->vid;
|
net: dsa: request drivers to perform FDB isolation
For DSA, to encourage drivers to perform FDB isolation simply means to
track which bridge does each FDB and MDB entry belong to. It then
becomes the driver responsibility to use something that makes the FDB
entry from one bridge not match the FDB lookup of ports from other
bridges.
The top-level functions where the bridge is determined are:
- dsa_port_fdb_{add,del}
- dsa_port_host_fdb_{add,del}
- dsa_port_mdb_{add,del}
- dsa_port_host_mdb_{add,del}
aka the pre-crosschip-notifier functions.
Changing the API to pass a reference to a bridge is not superfluous, and
looking at the passed bridge argument is not the same as having the
driver look at dsa_to_port(ds, port)->bridge from the ->port_fdb_add()
method.
DSA installs FDB and MDB entries on shared (CPU and DSA) ports as well,
and those do not have any dp->bridge information to retrieve, because
they are not in any bridge - they are merely the pipes that serve the
user ports that are in one or multiple bridges.
The struct dsa_bridge associated with each FDB/MDB entry is encapsulated
in a larger "struct dsa_db" database. Although only databases associated
to bridges are notified for now, this API will be the starting point for
implementing IFF_UNICAST_FLT in DSA. There, the idea is to install FDB
entries on the CPU port which belong to the corresponding user port's
port database. These are supposed to match only when the port is
standalone.
It is better to introduce the API in its expected final form than to
introduce it for bridges first, then to have to change drivers which may
have made one or more assumptions.
Drivers can use the provided bridge.num, but they can also use a
different numbering scheme that is more convenient.
DSA must perform refcounting on the CPU and DSA ports by also taking
into account the bridge number. So if two bridges request the same local
address, DSA must notify the driver twice, once for each bridge.
In fact, if the driver supports FDB isolation, DSA must perform
refcounting per bridge, but if the driver doesn't, DSA must refcount
host addresses across all bridges, otherwise it would be telling the
driver to delete an FDB entry for a bridge and the driver would delete
it for all bridges. So introduce a bool fdb_isolation in drivers which
would make all bridge databases passed to the cross-chip notifier have
the same number (0). This makes dsa_mac_addr_find() -> dsa_db_equal()
say that all bridge databases are the same database - which is
essentially the legacy behavior.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-02-25 09:22:22 +00:00
|
|
|
a->db = db;
|
net: dsa: reference count the MDB entries at the cross-chip notifier level
Ever since the cross-chip notifiers were introduced, the design was
meant to be simplistic and just get the job done without worrying too
much about dangling resources left behind.
For example, somebody installs an MDB entry on sw0p0 in this daisy chain
topology. It gets installed using ds->ops->port_mdb_add() on sw0p0,
sw1p4 and sw2p4.
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ x ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
Then the same person deletes that MDB entry. The cross-chip notifier for
deletion only matches sw0p0:
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ x ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ ]
Why?
Because the DSA links are 'trunk' ports, if we just go ahead and delete
the MDB from sw1p4 and sw2p4 directly, we might delete those multicast
entries when they are still needed. Just consider the fact that somebody
does:
- add a multicast MAC address towards sw0p0 [ via the cross-chip
notifiers it gets installed on the DSA links too ]
- add the same multicast MAC address towards sw0p1 (another port of that
same switch)
- delete the same multicast MAC address from sw0p0.
At this point, if we deleted the MAC address from the DSA links, it
would be flooded, even though there is still an entry on switch 0 which
needs it not to.
So that is why deletions only match the targeted source port and nothing
on DSA links. Of course, dangling resources means that the hardware
tables will eventually run out given enough additions/removals, but hey,
at least it's simple.
But there is a bigger concern which needs to be addressed, and that is
our support for SWITCHDEV_OBJ_ID_HOST_MDB. DSA simply translates such an
object into a dsa_port_host_mdb_add() which ends up as ds->ops->port_mdb_add()
on the upstream port, and a similar thing happens on deletion:
dsa_port_host_mdb_del() will trigger ds->ops->port_mdb_del() on the
upstream port.
When there are 2 VLAN-unaware bridges spanning the same switch (which is
a use case DSA proudly supports), each bridge will install its own
SWITCHDEV_OBJ_ID_HOST_MDB entries. But upon deletion, DSA goes ahead and
emits a DSA_NOTIFIER_MDB_DEL for dp->cpu_dp, which is shared between the
user ports enslaved to br0 and the user ports enslaved to br1. Not good.
The host-trapped multicast addresses installed by br1 will be deleted
when any state changes in br0 (IGMP timers expire, or ports leave, etc).
To avoid this, we could of course go the route of the zero-sum game and
delete the DSA_NOTIFIER_MDB_DEL call for dp->cpu_dp. But the better
design is to just admit that on shared ports like DSA links and CPU
ports, we should be reference counting calls, even if this consumes some
dynamic memory which DSA has traditionally avoided. On the flip side,
the hardware tables of switches are limited in size, so it would be good
if the OS managed them properly instead of having them eventually
overflow.
To address the memory usage concern, we only apply the refcounting of
MDB entries on ports that are really shared (CPU ports and DSA links)
and not on user ports. In a typical single-switch setup, this means only
the CPU port (and the host MDB entries are not that many, really).
The name of the newly introduced data structures (dsa_mac_addr) is
chosen in such a way that will be reusable for host FDB entries (next
patch).
With this change, we can finally have the same matching logic for the
MDB additions and deletions, as well as for their host-trapped variants.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-06-29 14:06:50 +00:00
|
|
|
refcount_set(&a->refcount, 1);
|
|
|
|
list_add_tail(&a->list, &dp->mdbs);
|
|
|
|
|
net: dsa: introduce locking for the address lists on CPU and DSA ports
Now that the rtnl_mutex is going away for dsa_port_{host_,}fdb_{add,del},
no one is serializing access to the address lists that DSA keeps for the
purpose of reference counting on shared ports (CPU and cascade ports).
It can happen for one dsa_switch_do_fdb_del to do list_del on a dp->fdbs
element while another dsa_switch_do_fdb_{add,del} is traversing dp->fdbs.
We need to avoid that.
Currently dp->mdbs is not at risk, because dsa_switch_do_mdb_{add,del}
still runs under the rtnl_mutex. But it would be nice if it would not
depend on that being the case. So let's introduce a mutex per port (the
address lists are per port too) and share it between dp->mdbs and
dp->fdbs.
The place where we put the locking is interesting. It could be tempting
to put a DSA-level lock which still serializes calls to
.port_fdb_{add,del}, but it would still not avoid concurrency with other
driver code paths that are currently under rtnl_mutex (.port_fdb_dump,
.port_fast_age). So it would add a very false sense of security (and
adding a global switch-wide lock in DSA to resynchronize with the
rtnl_lock is also counterproductive and hard).
So the locking is intentionally done only where the dp->fdbs and dp->mdbs
lists are traversed. That means, from a driver perspective, that
.port_fdb_add will be called with the dp->addr_lists_lock mutex held on
the CPU port, but not held on user ports. This is done so that driver
writers are not encouraged to rely on any guarantee offered by
dp->addr_lists_lock.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-10-24 17:17:54 +00:00
|
|
|
out:
|
|
|
|
mutex_unlock(&dp->addr_lists_lock);
|
|
|
|
|
|
|
|
return err;
|
net: dsa: reference count the MDB entries at the cross-chip notifier level
Ever since the cross-chip notifiers were introduced, the design was
meant to be simplistic and just get the job done without worrying too
much about dangling resources left behind.
For example, somebody installs an MDB entry on sw0p0 in this daisy chain
topology. It gets installed using ds->ops->port_mdb_add() on sw0p0,
sw1p4 and sw2p4.
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ x ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
Then the same person deletes that MDB entry. The cross-chip notifier for
deletion only matches sw0p0:
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ x ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ ]
Why?
Because the DSA links are 'trunk' ports, if we just go ahead and delete
the MDB from sw1p4 and sw2p4 directly, we might delete those multicast
entries when they are still needed. Just consider the fact that somebody
does:
- add a multicast MAC address towards sw0p0 [ via the cross-chip
notifiers it gets installed on the DSA links too ]
- add the same multicast MAC address towards sw0p1 (another port of that
same switch)
- delete the same multicast MAC address from sw0p0.
At this point, if we deleted the MAC address from the DSA links, it
would be flooded, even though there is still an entry on switch 0 which
needs it not to.
So that is why deletions only match the targeted source port and nothing
on DSA links. Of course, dangling resources means that the hardware
tables will eventually run out given enough additions/removals, but hey,
at least it's simple.
But there is a bigger concern which needs to be addressed, and that is
our support for SWITCHDEV_OBJ_ID_HOST_MDB. DSA simply translates such an
object into a dsa_port_host_mdb_add() which ends up as ds->ops->port_mdb_add()
on the upstream port, and a similar thing happens on deletion:
dsa_port_host_mdb_del() will trigger ds->ops->port_mdb_del() on the
upstream port.
When there are 2 VLAN-unaware bridges spanning the same switch (which is
a use case DSA proudly supports), each bridge will install its own
SWITCHDEV_OBJ_ID_HOST_MDB entries. But upon deletion, DSA goes ahead and
emits a DSA_NOTIFIER_MDB_DEL for dp->cpu_dp, which is shared between the
user ports enslaved to br0 and the user ports enslaved to br1. Not good.
The host-trapped multicast addresses installed by br1 will be deleted
when any state changes in br0 (IGMP timers expire, or ports leave, etc).
To avoid this, we could of course go the route of the zero-sum game and
delete the DSA_NOTIFIER_MDB_DEL call for dp->cpu_dp. But the better
design is to just admit that on shared ports like DSA links and CPU
ports, we should be reference counting calls, even if this consumes some
dynamic memory which DSA has traditionally avoided. On the flip side,
the hardware tables of switches are limited in size, so it would be good
if the OS managed them properly instead of having them eventually
overflow.
To address the memory usage concern, we only apply the refcounting of
MDB entries on ports that are really shared (CPU ports and DSA links)
and not on user ports. In a typical single-switch setup, this means only
the CPU port (and the host MDB entries are not that many, really).
The name of the newly introduced data structures (dsa_mac_addr) is
chosen in such a way that will be reusable for host FDB entries (next
patch).
With this change, we can finally have the same matching logic for the
MDB additions and deletions, as well as for their host-trapped variants.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-06-29 14:06:50 +00:00
|
|
|
}
|
|
|
|
|
2021-10-20 17:49:53 +00:00
|
|
|
static int dsa_port_do_mdb_del(struct dsa_port *dp,
|
net: dsa: request drivers to perform FDB isolation
For DSA, to encourage drivers to perform FDB isolation simply means to
track which bridge does each FDB and MDB entry belong to. It then
becomes the driver responsibility to use something that makes the FDB
entry from one bridge not match the FDB lookup of ports from other
bridges.
The top-level functions where the bridge is determined are:
- dsa_port_fdb_{add,del}
- dsa_port_host_fdb_{add,del}
- dsa_port_mdb_{add,del}
- dsa_port_host_mdb_{add,del}
aka the pre-crosschip-notifier functions.
Changing the API to pass a reference to a bridge is not superfluous, and
looking at the passed bridge argument is not the same as having the
driver look at dsa_to_port(ds, port)->bridge from the ->port_fdb_add()
method.
DSA installs FDB and MDB entries on shared (CPU and DSA) ports as well,
and those do not have any dp->bridge information to retrieve, because
they are not in any bridge - they are merely the pipes that serve the
user ports that are in one or multiple bridges.
The struct dsa_bridge associated with each FDB/MDB entry is encapsulated
in a larger "struct dsa_db" database. Although only databases associated
to bridges are notified for now, this API will be the starting point for
implementing IFF_UNICAST_FLT in DSA. There, the idea is to install FDB
entries on the CPU port which belong to the corresponding user port's
port database. These are supposed to match only when the port is
standalone.
It is better to introduce the API in its expected final form than to
introduce it for bridges first, then to have to change drivers which may
have made one or more assumptions.
Drivers can use the provided bridge.num, but they can also use a
different numbering scheme that is more convenient.
DSA must perform refcounting on the CPU and DSA ports by also taking
into account the bridge number. So if two bridges request the same local
address, DSA must notify the driver twice, once for each bridge.
In fact, if the driver supports FDB isolation, DSA must perform
refcounting per bridge, but if the driver doesn't, DSA must refcount
host addresses across all bridges, otherwise it would be telling the
driver to delete an FDB entry for a bridge and the driver would delete
it for all bridges. So introduce a bool fdb_isolation in drivers which
would make all bridge databases passed to the cross-chip notifier have
the same number (0). This makes dsa_mac_addr_find() -> dsa_db_equal()
say that all bridge databases are the same database - which is
essentially the legacy behavior.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-02-25 09:22:22 +00:00
|
|
|
const struct switchdev_obj_port_mdb *mdb,
|
|
|
|
struct dsa_db db)
|
net: dsa: reference count the MDB entries at the cross-chip notifier level
Ever since the cross-chip notifiers were introduced, the design was
meant to be simplistic and just get the job done without worrying too
much about dangling resources left behind.
For example, somebody installs an MDB entry on sw0p0 in this daisy chain
topology. It gets installed using ds->ops->port_mdb_add() on sw0p0,
sw1p4 and sw2p4.
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ x ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
Then the same person deletes that MDB entry. The cross-chip notifier for
deletion only matches sw0p0:
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ x ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ ]
Why?
Because the DSA links are 'trunk' ports, if we just go ahead and delete
the MDB from sw1p4 and sw2p4 directly, we might delete those multicast
entries when they are still needed. Just consider the fact that somebody
does:
- add a multicast MAC address towards sw0p0 [ via the cross-chip
notifiers it gets installed on the DSA links too ]
- add the same multicast MAC address towards sw0p1 (another port of that
same switch)
- delete the same multicast MAC address from sw0p0.
At this point, if we deleted the MAC address from the DSA links, it
would be flooded, even though there is still an entry on switch 0 which
needs it not to.
So that is why deletions only match the targeted source port and nothing
on DSA links. Of course, dangling resources means that the hardware
tables will eventually run out given enough additions/removals, but hey,
at least it's simple.
But there is a bigger concern which needs to be addressed, and that is
our support for SWITCHDEV_OBJ_ID_HOST_MDB. DSA simply translates such an
object into a dsa_port_host_mdb_add() which ends up as ds->ops->port_mdb_add()
on the upstream port, and a similar thing happens on deletion:
dsa_port_host_mdb_del() will trigger ds->ops->port_mdb_del() on the
upstream port.
When there are 2 VLAN-unaware bridges spanning the same switch (which is
a use case DSA proudly supports), each bridge will install its own
SWITCHDEV_OBJ_ID_HOST_MDB entries. But upon deletion, DSA goes ahead and
emits a DSA_NOTIFIER_MDB_DEL for dp->cpu_dp, which is shared between the
user ports enslaved to br0 and the user ports enslaved to br1. Not good.
The host-trapped multicast addresses installed by br1 will be deleted
when any state changes in br0 (IGMP timers expire, or ports leave, etc).
To avoid this, we could of course go the route of the zero-sum game and
delete the DSA_NOTIFIER_MDB_DEL call for dp->cpu_dp. But the better
design is to just admit that on shared ports like DSA links and CPU
ports, we should be reference counting calls, even if this consumes some
dynamic memory which DSA has traditionally avoided. On the flip side,
the hardware tables of switches are limited in size, so it would be good
if the OS managed them properly instead of having them eventually
overflow.
To address the memory usage concern, we only apply the refcounting of
MDB entries on ports that are really shared (CPU ports and DSA links)
and not on user ports. In a typical single-switch setup, this means only
the CPU port (and the host MDB entries are not that many, really).
The name of the newly introduced data structures (dsa_mac_addr) is
chosen in such a way that will be reusable for host FDB entries (next
patch).
With this change, we can finally have the same matching logic for the
MDB additions and deletions, as well as for their host-trapped variants.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-06-29 14:06:50 +00:00
|
|
|
{
|
2021-10-20 17:49:53 +00:00
|
|
|
struct dsa_switch *ds = dp->ds;
|
net: dsa: reference count the MDB entries at the cross-chip notifier level
Ever since the cross-chip notifiers were introduced, the design was
meant to be simplistic and just get the job done without worrying too
much about dangling resources left behind.
For example, somebody installs an MDB entry on sw0p0 in this daisy chain
topology. It gets installed using ds->ops->port_mdb_add() on sw0p0,
sw1p4 and sw2p4.
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ x ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
Then the same person deletes that MDB entry. The cross-chip notifier for
deletion only matches sw0p0:
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ x ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ ]
Why?
Because the DSA links are 'trunk' ports, if we just go ahead and delete
the MDB from sw1p4 and sw2p4 directly, we might delete those multicast
entries when they are still needed. Just consider the fact that somebody
does:
- add a multicast MAC address towards sw0p0 [ via the cross-chip
notifiers it gets installed on the DSA links too ]
- add the same multicast MAC address towards sw0p1 (another port of that
same switch)
- delete the same multicast MAC address from sw0p0.
At this point, if we deleted the MAC address from the DSA links, it
would be flooded, even though there is still an entry on switch 0 which
needs it not to.
So that is why deletions only match the targeted source port and nothing
on DSA links. Of course, dangling resources means that the hardware
tables will eventually run out given enough additions/removals, but hey,
at least it's simple.
But there is a bigger concern which needs to be addressed, and that is
our support for SWITCHDEV_OBJ_ID_HOST_MDB. DSA simply translates such an
object into a dsa_port_host_mdb_add() which ends up as ds->ops->port_mdb_add()
on the upstream port, and a similar thing happens on deletion:
dsa_port_host_mdb_del() will trigger ds->ops->port_mdb_del() on the
upstream port.
When there are 2 VLAN-unaware bridges spanning the same switch (which is
a use case DSA proudly supports), each bridge will install its own
SWITCHDEV_OBJ_ID_HOST_MDB entries. But upon deletion, DSA goes ahead and
emits a DSA_NOTIFIER_MDB_DEL for dp->cpu_dp, which is shared between the
user ports enslaved to br0 and the user ports enslaved to br1. Not good.
The host-trapped multicast addresses installed by br1 will be deleted
when any state changes in br0 (IGMP timers expire, or ports leave, etc).
To avoid this, we could of course go the route of the zero-sum game and
delete the DSA_NOTIFIER_MDB_DEL call for dp->cpu_dp. But the better
design is to just admit that on shared ports like DSA links and CPU
ports, we should be reference counting calls, even if this consumes some
dynamic memory which DSA has traditionally avoided. On the flip side,
the hardware tables of switches are limited in size, so it would be good
if the OS managed them properly instead of having them eventually
overflow.
To address the memory usage concern, we only apply the refcounting of
MDB entries on ports that are really shared (CPU ports and DSA links)
and not on user ports. In a typical single-switch setup, this means only
the CPU port (and the host MDB entries are not that many, really).
The name of the newly introduced data structures (dsa_mac_addr) is
chosen in such a way that will be reusable for host FDB entries (next
patch).
With this change, we can finally have the same matching logic for the
MDB additions and deletions, as well as for their host-trapped variants.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-06-29 14:06:50 +00:00
|
|
|
struct dsa_mac_addr *a;
|
2021-10-20 17:49:53 +00:00
|
|
|
int port = dp->index;
|
net: dsa: introduce locking for the address lists on CPU and DSA ports
Now that the rtnl_mutex is going away for dsa_port_{host_,}fdb_{add,del},
no one is serializing access to the address lists that DSA keeps for the
purpose of reference counting on shared ports (CPU and cascade ports).
It can happen for one dsa_switch_do_fdb_del to do list_del on a dp->fdbs
element while another dsa_switch_do_fdb_{add,del} is traversing dp->fdbs.
We need to avoid that.
Currently dp->mdbs is not at risk, because dsa_switch_do_mdb_{add,del}
still runs under the rtnl_mutex. But it would be nice if it would not
depend on that being the case. So let's introduce a mutex per port (the
address lists are per port too) and share it between dp->mdbs and
dp->fdbs.
The place where we put the locking is interesting. It could be tempting
to put a DSA-level lock which still serializes calls to
.port_fdb_{add,del}, but it would still not avoid concurrency with other
driver code paths that are currently under rtnl_mutex (.port_fdb_dump,
.port_fast_age). So it would add a very false sense of security (and
adding a global switch-wide lock in DSA to resynchronize with the
rtnl_lock is also counterproductive and hard).
So the locking is intentionally done only where the dp->fdbs and dp->mdbs
lists are traversed. That means, from a driver perspective, that
.port_fdb_add will be called with the dp->addr_lists_lock mutex held on
the CPU port, but not held on user ports. This is done so that driver
writers are not encouraged to rely on any guarantee offered by
dp->addr_lists_lock.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-10-24 17:17:54 +00:00
|
|
|
int err = 0;
|
net: dsa: reference count the MDB entries at the cross-chip notifier level
Ever since the cross-chip notifiers were introduced, the design was
meant to be simplistic and just get the job done without worrying too
much about dangling resources left behind.
For example, somebody installs an MDB entry on sw0p0 in this daisy chain
topology. It gets installed using ds->ops->port_mdb_add() on sw0p0,
sw1p4 and sw2p4.
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ x ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
Then the same person deletes that MDB entry. The cross-chip notifier for
deletion only matches sw0p0:
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ x ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ ]
Why?
Because the DSA links are 'trunk' ports, if we just go ahead and delete
the MDB from sw1p4 and sw2p4 directly, we might delete those multicast
entries when they are still needed. Just consider the fact that somebody
does:
- add a multicast MAC address towards sw0p0 [ via the cross-chip
notifiers it gets installed on the DSA links too ]
- add the same multicast MAC address towards sw0p1 (another port of that
same switch)
- delete the same multicast MAC address from sw0p0.
At this point, if we deleted the MAC address from the DSA links, it
would be flooded, even though there is still an entry on switch 0 which
needs it not to.
So that is why deletions only match the targeted source port and nothing
on DSA links. Of course, dangling resources means that the hardware
tables will eventually run out given enough additions/removals, but hey,
at least it's simple.
But there is a bigger concern which needs to be addressed, and that is
our support for SWITCHDEV_OBJ_ID_HOST_MDB. DSA simply translates such an
object into a dsa_port_host_mdb_add() which ends up as ds->ops->port_mdb_add()
on the upstream port, and a similar thing happens on deletion:
dsa_port_host_mdb_del() will trigger ds->ops->port_mdb_del() on the
upstream port.
When there are 2 VLAN-unaware bridges spanning the same switch (which is
a use case DSA proudly supports), each bridge will install its own
SWITCHDEV_OBJ_ID_HOST_MDB entries. But upon deletion, DSA goes ahead and
emits a DSA_NOTIFIER_MDB_DEL for dp->cpu_dp, which is shared between the
user ports enslaved to br0 and the user ports enslaved to br1. Not good.
The host-trapped multicast addresses installed by br1 will be deleted
when any state changes in br0 (IGMP timers expire, or ports leave, etc).
To avoid this, we could of course go the route of the zero-sum game and
delete the DSA_NOTIFIER_MDB_DEL call for dp->cpu_dp. But the better
design is to just admit that on shared ports like DSA links and CPU
ports, we should be reference counting calls, even if this consumes some
dynamic memory which DSA has traditionally avoided. On the flip side,
the hardware tables of switches are limited in size, so it would be good
if the OS managed them properly instead of having them eventually
overflow.
To address the memory usage concern, we only apply the refcounting of
MDB entries on ports that are really shared (CPU ports and DSA links)
and not on user ports. In a typical single-switch setup, this means only
the CPU port (and the host MDB entries are not that many, really).
The name of the newly introduced data structures (dsa_mac_addr) is
chosen in such a way that will be reusable for host FDB entries (next
patch).
With this change, we can finally have the same matching logic for the
MDB additions and deletions, as well as for their host-trapped variants.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-06-29 14:06:50 +00:00
|
|
|
|
|
|
|
/* No need to bother with refcounting for user ports */
|
|
|
|
if (!(dsa_port_is_cpu(dp) || dsa_port_is_dsa(dp)))
|
net: dsa: request drivers to perform FDB isolation
For DSA, to encourage drivers to perform FDB isolation simply means to
track which bridge does each FDB and MDB entry belong to. It then
becomes the driver responsibility to use something that makes the FDB
entry from one bridge not match the FDB lookup of ports from other
bridges.
The top-level functions where the bridge is determined are:
- dsa_port_fdb_{add,del}
- dsa_port_host_fdb_{add,del}
- dsa_port_mdb_{add,del}
- dsa_port_host_mdb_{add,del}
aka the pre-crosschip-notifier functions.
Changing the API to pass a reference to a bridge is not superfluous, and
looking at the passed bridge argument is not the same as having the
driver look at dsa_to_port(ds, port)->bridge from the ->port_fdb_add()
method.
DSA installs FDB and MDB entries on shared (CPU and DSA) ports as well,
and those do not have any dp->bridge information to retrieve, because
they are not in any bridge - they are merely the pipes that serve the
user ports that are in one or multiple bridges.
The struct dsa_bridge associated with each FDB/MDB entry is encapsulated
in a larger "struct dsa_db" database. Although only databases associated
to bridges are notified for now, this API will be the starting point for
implementing IFF_UNICAST_FLT in DSA. There, the idea is to install FDB
entries on the CPU port which belong to the corresponding user port's
port database. These are supposed to match only when the port is
standalone.
It is better to introduce the API in its expected final form than to
introduce it for bridges first, then to have to change drivers which may
have made one or more assumptions.
Drivers can use the provided bridge.num, but they can also use a
different numbering scheme that is more convenient.
DSA must perform refcounting on the CPU and DSA ports by also taking
into account the bridge number. So if two bridges request the same local
address, DSA must notify the driver twice, once for each bridge.
In fact, if the driver supports FDB isolation, DSA must perform
refcounting per bridge, but if the driver doesn't, DSA must refcount
host addresses across all bridges, otherwise it would be telling the
driver to delete an FDB entry for a bridge and the driver would delete
it for all bridges. So introduce a bool fdb_isolation in drivers which
would make all bridge databases passed to the cross-chip notifier have
the same number (0). This makes dsa_mac_addr_find() -> dsa_db_equal()
say that all bridge databases are the same database - which is
essentially the legacy behavior.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-02-25 09:22:22 +00:00
|
|
|
return ds->ops->port_mdb_del(ds, port, mdb, db);
|
net: dsa: reference count the MDB entries at the cross-chip notifier level
Ever since the cross-chip notifiers were introduced, the design was
meant to be simplistic and just get the job done without worrying too
much about dangling resources left behind.
For example, somebody installs an MDB entry on sw0p0 in this daisy chain
topology. It gets installed using ds->ops->port_mdb_add() on sw0p0,
sw1p4 and sw2p4.
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ x ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
Then the same person deletes that MDB entry. The cross-chip notifier for
deletion only matches sw0p0:
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ x ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ ]
Why?
Because the DSA links are 'trunk' ports, if we just go ahead and delete
the MDB from sw1p4 and sw2p4 directly, we might delete those multicast
entries when they are still needed. Just consider the fact that somebody
does:
- add a multicast MAC address towards sw0p0 [ via the cross-chip
notifiers it gets installed on the DSA links too ]
- add the same multicast MAC address towards sw0p1 (another port of that
same switch)
- delete the same multicast MAC address from sw0p0.
At this point, if we deleted the MAC address from the DSA links, it
would be flooded, even though there is still an entry on switch 0 which
needs it not to.
So that is why deletions only match the targeted source port and nothing
on DSA links. Of course, dangling resources means that the hardware
tables will eventually run out given enough additions/removals, but hey,
at least it's simple.
But there is a bigger concern which needs to be addressed, and that is
our support for SWITCHDEV_OBJ_ID_HOST_MDB. DSA simply translates such an
object into a dsa_port_host_mdb_add() which ends up as ds->ops->port_mdb_add()
on the upstream port, and a similar thing happens on deletion:
dsa_port_host_mdb_del() will trigger ds->ops->port_mdb_del() on the
upstream port.
When there are 2 VLAN-unaware bridges spanning the same switch (which is
a use case DSA proudly supports), each bridge will install its own
SWITCHDEV_OBJ_ID_HOST_MDB entries. But upon deletion, DSA goes ahead and
emits a DSA_NOTIFIER_MDB_DEL for dp->cpu_dp, which is shared between the
user ports enslaved to br0 and the user ports enslaved to br1. Not good.
The host-trapped multicast addresses installed by br1 will be deleted
when any state changes in br0 (IGMP timers expire, or ports leave, etc).
To avoid this, we could of course go the route of the zero-sum game and
delete the DSA_NOTIFIER_MDB_DEL call for dp->cpu_dp. But the better
design is to just admit that on shared ports like DSA links and CPU
ports, we should be reference counting calls, even if this consumes some
dynamic memory which DSA has traditionally avoided. On the flip side,
the hardware tables of switches are limited in size, so it would be good
if the OS managed them properly instead of having them eventually
overflow.
To address the memory usage concern, we only apply the refcounting of
MDB entries on ports that are really shared (CPU ports and DSA links)
and not on user ports. In a typical single-switch setup, this means only
the CPU port (and the host MDB entries are not that many, really).
The name of the newly introduced data structures (dsa_mac_addr) is
chosen in such a way that will be reusable for host FDB entries (next
patch).
With this change, we can finally have the same matching logic for the
MDB additions and deletions, as well as for their host-trapped variants.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-06-29 14:06:50 +00:00
|
|
|
|
net: dsa: introduce locking for the address lists on CPU and DSA ports
Now that the rtnl_mutex is going away for dsa_port_{host_,}fdb_{add,del},
no one is serializing access to the address lists that DSA keeps for the
purpose of reference counting on shared ports (CPU and cascade ports).
It can happen for one dsa_switch_do_fdb_del to do list_del on a dp->fdbs
element while another dsa_switch_do_fdb_{add,del} is traversing dp->fdbs.
We need to avoid that.
Currently dp->mdbs is not at risk, because dsa_switch_do_mdb_{add,del}
still runs under the rtnl_mutex. But it would be nice if it would not
depend on that being the case. So let's introduce a mutex per port (the
address lists are per port too) and share it between dp->mdbs and
dp->fdbs.
The place where we put the locking is interesting. It could be tempting
to put a DSA-level lock which still serializes calls to
.port_fdb_{add,del}, but it would still not avoid concurrency with other
driver code paths that are currently under rtnl_mutex (.port_fdb_dump,
.port_fast_age). So it would add a very false sense of security (and
adding a global switch-wide lock in DSA to resynchronize with the
rtnl_lock is also counterproductive and hard).
So the locking is intentionally done only where the dp->fdbs and dp->mdbs
lists are traversed. That means, from a driver perspective, that
.port_fdb_add will be called with the dp->addr_lists_lock mutex held on
the CPU port, but not held on user ports. This is done so that driver
writers are not encouraged to rely on any guarantee offered by
dp->addr_lists_lock.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-10-24 17:17:54 +00:00
|
|
|
mutex_lock(&dp->addr_lists_lock);
|
|
|
|
|
net: dsa: request drivers to perform FDB isolation
For DSA, to encourage drivers to perform FDB isolation simply means to
track which bridge does each FDB and MDB entry belong to. It then
becomes the driver responsibility to use something that makes the FDB
entry from one bridge not match the FDB lookup of ports from other
bridges.
The top-level functions where the bridge is determined are:
- dsa_port_fdb_{add,del}
- dsa_port_host_fdb_{add,del}
- dsa_port_mdb_{add,del}
- dsa_port_host_mdb_{add,del}
aka the pre-crosschip-notifier functions.
Changing the API to pass a reference to a bridge is not superfluous, and
looking at the passed bridge argument is not the same as having the
driver look at dsa_to_port(ds, port)->bridge from the ->port_fdb_add()
method.
DSA installs FDB and MDB entries on shared (CPU and DSA) ports as well,
and those do not have any dp->bridge information to retrieve, because
they are not in any bridge - they are merely the pipes that serve the
user ports that are in one or multiple bridges.
The struct dsa_bridge associated with each FDB/MDB entry is encapsulated
in a larger "struct dsa_db" database. Although only databases associated
to bridges are notified for now, this API will be the starting point for
implementing IFF_UNICAST_FLT in DSA. There, the idea is to install FDB
entries on the CPU port which belong to the corresponding user port's
port database. These are supposed to match only when the port is
standalone.
It is better to introduce the API in its expected final form than to
introduce it for bridges first, then to have to change drivers which may
have made one or more assumptions.
Drivers can use the provided bridge.num, but they can also use a
different numbering scheme that is more convenient.
DSA must perform refcounting on the CPU and DSA ports by also taking
into account the bridge number. So if two bridges request the same local
address, DSA must notify the driver twice, once for each bridge.
In fact, if the driver supports FDB isolation, DSA must perform
refcounting per bridge, but if the driver doesn't, DSA must refcount
host addresses across all bridges, otherwise it would be telling the
driver to delete an FDB entry for a bridge and the driver would delete
it for all bridges. So introduce a bool fdb_isolation in drivers which
would make all bridge databases passed to the cross-chip notifier have
the same number (0). This makes dsa_mac_addr_find() -> dsa_db_equal()
say that all bridge databases are the same database - which is
essentially the legacy behavior.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-02-25 09:22:22 +00:00
|
|
|
a = dsa_mac_addr_find(&dp->mdbs, mdb->addr, mdb->vid, db);
|
net: dsa: introduce locking for the address lists on CPU and DSA ports
Now that the rtnl_mutex is going away for dsa_port_{host_,}fdb_{add,del},
no one is serializing access to the address lists that DSA keeps for the
purpose of reference counting on shared ports (CPU and cascade ports).
It can happen for one dsa_switch_do_fdb_del to do list_del on a dp->fdbs
element while another dsa_switch_do_fdb_{add,del} is traversing dp->fdbs.
We need to avoid that.
Currently dp->mdbs is not at risk, because dsa_switch_do_mdb_{add,del}
still runs under the rtnl_mutex. But it would be nice if it would not
depend on that being the case. So let's introduce a mutex per port (the
address lists are per port too) and share it between dp->mdbs and
dp->fdbs.
The place where we put the locking is interesting. It could be tempting
to put a DSA-level lock which still serializes calls to
.port_fdb_{add,del}, but it would still not avoid concurrency with other
driver code paths that are currently under rtnl_mutex (.port_fdb_dump,
.port_fast_age). So it would add a very false sense of security (and
adding a global switch-wide lock in DSA to resynchronize with the
rtnl_lock is also counterproductive and hard).
So the locking is intentionally done only where the dp->fdbs and dp->mdbs
lists are traversed. That means, from a driver perspective, that
.port_fdb_add will be called with the dp->addr_lists_lock mutex held on
the CPU port, but not held on user ports. This is done so that driver
writers are not encouraged to rely on any guarantee offered by
dp->addr_lists_lock.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-10-24 17:17:54 +00:00
|
|
|
if (!a) {
|
|
|
|
err = -ENOENT;
|
|
|
|
goto out;
|
|
|
|
}
|
net: dsa: reference count the MDB entries at the cross-chip notifier level
Ever since the cross-chip notifiers were introduced, the design was
meant to be simplistic and just get the job done without worrying too
much about dangling resources left behind.
For example, somebody installs an MDB entry on sw0p0 in this daisy chain
topology. It gets installed using ds->ops->port_mdb_add() on sw0p0,
sw1p4 and sw2p4.
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ x ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
Then the same person deletes that MDB entry. The cross-chip notifier for
deletion only matches sw0p0:
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ x ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ ]
Why?
Because the DSA links are 'trunk' ports, if we just go ahead and delete
the MDB from sw1p4 and sw2p4 directly, we might delete those multicast
entries when they are still needed. Just consider the fact that somebody
does:
- add a multicast MAC address towards sw0p0 [ via the cross-chip
notifiers it gets installed on the DSA links too ]
- add the same multicast MAC address towards sw0p1 (another port of that
same switch)
- delete the same multicast MAC address from sw0p0.
At this point, if we deleted the MAC address from the DSA links, it
would be flooded, even though there is still an entry on switch 0 which
needs it not to.
So that is why deletions only match the targeted source port and nothing
on DSA links. Of course, dangling resources means that the hardware
tables will eventually run out given enough additions/removals, but hey,
at least it's simple.
But there is a bigger concern which needs to be addressed, and that is
our support for SWITCHDEV_OBJ_ID_HOST_MDB. DSA simply translates such an
object into a dsa_port_host_mdb_add() which ends up as ds->ops->port_mdb_add()
on the upstream port, and a similar thing happens on deletion:
dsa_port_host_mdb_del() will trigger ds->ops->port_mdb_del() on the
upstream port.
When there are 2 VLAN-unaware bridges spanning the same switch (which is
a use case DSA proudly supports), each bridge will install its own
SWITCHDEV_OBJ_ID_HOST_MDB entries. But upon deletion, DSA goes ahead and
emits a DSA_NOTIFIER_MDB_DEL for dp->cpu_dp, which is shared between the
user ports enslaved to br0 and the user ports enslaved to br1. Not good.
The host-trapped multicast addresses installed by br1 will be deleted
when any state changes in br0 (IGMP timers expire, or ports leave, etc).
To avoid this, we could of course go the route of the zero-sum game and
delete the DSA_NOTIFIER_MDB_DEL call for dp->cpu_dp. But the better
design is to just admit that on shared ports like DSA links and CPU
ports, we should be reference counting calls, even if this consumes some
dynamic memory which DSA has traditionally avoided. On the flip side,
the hardware tables of switches are limited in size, so it would be good
if the OS managed them properly instead of having them eventually
overflow.
To address the memory usage concern, we only apply the refcounting of
MDB entries on ports that are really shared (CPU ports and DSA links)
and not on user ports. In a typical single-switch setup, this means only
the CPU port (and the host MDB entries are not that many, really).
The name of the newly introduced data structures (dsa_mac_addr) is
chosen in such a way that will be reusable for host FDB entries (next
patch).
With this change, we can finally have the same matching logic for the
MDB additions and deletions, as well as for their host-trapped variants.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-06-29 14:06:50 +00:00
|
|
|
|
|
|
|
if (!refcount_dec_and_test(&a->refcount))
|
net: dsa: introduce locking for the address lists on CPU and DSA ports
Now that the rtnl_mutex is going away for dsa_port_{host_,}fdb_{add,del},
no one is serializing access to the address lists that DSA keeps for the
purpose of reference counting on shared ports (CPU and cascade ports).
It can happen for one dsa_switch_do_fdb_del to do list_del on a dp->fdbs
element while another dsa_switch_do_fdb_{add,del} is traversing dp->fdbs.
We need to avoid that.
Currently dp->mdbs is not at risk, because dsa_switch_do_mdb_{add,del}
still runs under the rtnl_mutex. But it would be nice if it would not
depend on that being the case. So let's introduce a mutex per port (the
address lists are per port too) and share it between dp->mdbs and
dp->fdbs.
The place where we put the locking is interesting. It could be tempting
to put a DSA-level lock which still serializes calls to
.port_fdb_{add,del}, but it would still not avoid concurrency with other
driver code paths that are currently under rtnl_mutex (.port_fdb_dump,
.port_fast_age). So it would add a very false sense of security (and
adding a global switch-wide lock in DSA to resynchronize with the
rtnl_lock is also counterproductive and hard).
So the locking is intentionally done only where the dp->fdbs and dp->mdbs
lists are traversed. That means, from a driver perspective, that
.port_fdb_add will be called with the dp->addr_lists_lock mutex held on
the CPU port, but not held on user ports. This is done so that driver
writers are not encouraged to rely on any guarantee offered by
dp->addr_lists_lock.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-10-24 17:17:54 +00:00
|
|
|
goto out;
|
net: dsa: reference count the MDB entries at the cross-chip notifier level
Ever since the cross-chip notifiers were introduced, the design was
meant to be simplistic and just get the job done without worrying too
much about dangling resources left behind.
For example, somebody installs an MDB entry on sw0p0 in this daisy chain
topology. It gets installed using ds->ops->port_mdb_add() on sw0p0,
sw1p4 and sw2p4.
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ x ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
Then the same person deletes that MDB entry. The cross-chip notifier for
deletion only matches sw0p0:
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ x ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ ]
Why?
Because the DSA links are 'trunk' ports, if we just go ahead and delete
the MDB from sw1p4 and sw2p4 directly, we might delete those multicast
entries when they are still needed. Just consider the fact that somebody
does:
- add a multicast MAC address towards sw0p0 [ via the cross-chip
notifiers it gets installed on the DSA links too ]
- add the same multicast MAC address towards sw0p1 (another port of that
same switch)
- delete the same multicast MAC address from sw0p0.
At this point, if we deleted the MAC address from the DSA links, it
would be flooded, even though there is still an entry on switch 0 which
needs it not to.
So that is why deletions only match the targeted source port and nothing
on DSA links. Of course, dangling resources means that the hardware
tables will eventually run out given enough additions/removals, but hey,
at least it's simple.
But there is a bigger concern which needs to be addressed, and that is
our support for SWITCHDEV_OBJ_ID_HOST_MDB. DSA simply translates such an
object into a dsa_port_host_mdb_add() which ends up as ds->ops->port_mdb_add()
on the upstream port, and a similar thing happens on deletion:
dsa_port_host_mdb_del() will trigger ds->ops->port_mdb_del() on the
upstream port.
When there are 2 VLAN-unaware bridges spanning the same switch (which is
a use case DSA proudly supports), each bridge will install its own
SWITCHDEV_OBJ_ID_HOST_MDB entries. But upon deletion, DSA goes ahead and
emits a DSA_NOTIFIER_MDB_DEL for dp->cpu_dp, which is shared between the
user ports enslaved to br0 and the user ports enslaved to br1. Not good.
The host-trapped multicast addresses installed by br1 will be deleted
when any state changes in br0 (IGMP timers expire, or ports leave, etc).
To avoid this, we could of course go the route of the zero-sum game and
delete the DSA_NOTIFIER_MDB_DEL call for dp->cpu_dp. But the better
design is to just admit that on shared ports like DSA links and CPU
ports, we should be reference counting calls, even if this consumes some
dynamic memory which DSA has traditionally avoided. On the flip side,
the hardware tables of switches are limited in size, so it would be good
if the OS managed them properly instead of having them eventually
overflow.
To address the memory usage concern, we only apply the refcounting of
MDB entries on ports that are really shared (CPU ports and DSA links)
and not on user ports. In a typical single-switch setup, this means only
the CPU port (and the host MDB entries are not that many, really).
The name of the newly introduced data structures (dsa_mac_addr) is
chosen in such a way that will be reusable for host FDB entries (next
patch).
With this change, we can finally have the same matching logic for the
MDB additions and deletions, as well as for their host-trapped variants.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-06-29 14:06:50 +00:00
|
|
|
|
net: dsa: request drivers to perform FDB isolation
For DSA, to encourage drivers to perform FDB isolation simply means to
track which bridge does each FDB and MDB entry belong to. It then
becomes the driver responsibility to use something that makes the FDB
entry from one bridge not match the FDB lookup of ports from other
bridges.
The top-level functions where the bridge is determined are:
- dsa_port_fdb_{add,del}
- dsa_port_host_fdb_{add,del}
- dsa_port_mdb_{add,del}
- dsa_port_host_mdb_{add,del}
aka the pre-crosschip-notifier functions.
Changing the API to pass a reference to a bridge is not superfluous, and
looking at the passed bridge argument is not the same as having the
driver look at dsa_to_port(ds, port)->bridge from the ->port_fdb_add()
method.
DSA installs FDB and MDB entries on shared (CPU and DSA) ports as well,
and those do not have any dp->bridge information to retrieve, because
they are not in any bridge - they are merely the pipes that serve the
user ports that are in one or multiple bridges.
The struct dsa_bridge associated with each FDB/MDB entry is encapsulated
in a larger "struct dsa_db" database. Although only databases associated
to bridges are notified for now, this API will be the starting point for
implementing IFF_UNICAST_FLT in DSA. There, the idea is to install FDB
entries on the CPU port which belong to the corresponding user port's
port database. These are supposed to match only when the port is
standalone.
It is better to introduce the API in its expected final form than to
introduce it for bridges first, then to have to change drivers which may
have made one or more assumptions.
Drivers can use the provided bridge.num, but they can also use a
different numbering scheme that is more convenient.
DSA must perform refcounting on the CPU and DSA ports by also taking
into account the bridge number. So if two bridges request the same local
address, DSA must notify the driver twice, once for each bridge.
In fact, if the driver supports FDB isolation, DSA must perform
refcounting per bridge, but if the driver doesn't, DSA must refcount
host addresses across all bridges, otherwise it would be telling the
driver to delete an FDB entry for a bridge and the driver would delete
it for all bridges. So introduce a bool fdb_isolation in drivers which
would make all bridge databases passed to the cross-chip notifier have
the same number (0). This makes dsa_mac_addr_find() -> dsa_db_equal()
say that all bridge databases are the same database - which is
essentially the legacy behavior.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-02-25 09:22:22 +00:00
|
|
|
err = ds->ops->port_mdb_del(ds, port, mdb, db);
|
net: dsa: reference count the MDB entries at the cross-chip notifier level
Ever since the cross-chip notifiers were introduced, the design was
meant to be simplistic and just get the job done without worrying too
much about dangling resources left behind.
For example, somebody installs an MDB entry on sw0p0 in this daisy chain
topology. It gets installed using ds->ops->port_mdb_add() on sw0p0,
sw1p4 and sw2p4.
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ x ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
Then the same person deletes that MDB entry. The cross-chip notifier for
deletion only matches sw0p0:
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ x ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ ]
Why?
Because the DSA links are 'trunk' ports, if we just go ahead and delete
the MDB from sw1p4 and sw2p4 directly, we might delete those multicast
entries when they are still needed. Just consider the fact that somebody
does:
- add a multicast MAC address towards sw0p0 [ via the cross-chip
notifiers it gets installed on the DSA links too ]
- add the same multicast MAC address towards sw0p1 (another port of that
same switch)
- delete the same multicast MAC address from sw0p0.
At this point, if we deleted the MAC address from the DSA links, it
would be flooded, even though there is still an entry on switch 0 which
needs it not to.
So that is why deletions only match the targeted source port and nothing
on DSA links. Of course, dangling resources means that the hardware
tables will eventually run out given enough additions/removals, but hey,
at least it's simple.
But there is a bigger concern which needs to be addressed, and that is
our support for SWITCHDEV_OBJ_ID_HOST_MDB. DSA simply translates such an
object into a dsa_port_host_mdb_add() which ends up as ds->ops->port_mdb_add()
on the upstream port, and a similar thing happens on deletion:
dsa_port_host_mdb_del() will trigger ds->ops->port_mdb_del() on the
upstream port.
When there are 2 VLAN-unaware bridges spanning the same switch (which is
a use case DSA proudly supports), each bridge will install its own
SWITCHDEV_OBJ_ID_HOST_MDB entries. But upon deletion, DSA goes ahead and
emits a DSA_NOTIFIER_MDB_DEL for dp->cpu_dp, which is shared between the
user ports enslaved to br0 and the user ports enslaved to br1. Not good.
The host-trapped multicast addresses installed by br1 will be deleted
when any state changes in br0 (IGMP timers expire, or ports leave, etc).
To avoid this, we could of course go the route of the zero-sum game and
delete the DSA_NOTIFIER_MDB_DEL call for dp->cpu_dp. But the better
design is to just admit that on shared ports like DSA links and CPU
ports, we should be reference counting calls, even if this consumes some
dynamic memory which DSA has traditionally avoided. On the flip side,
the hardware tables of switches are limited in size, so it would be good
if the OS managed them properly instead of having them eventually
overflow.
To address the memory usage concern, we only apply the refcounting of
MDB entries on ports that are really shared (CPU ports and DSA links)
and not on user ports. In a typical single-switch setup, this means only
the CPU port (and the host MDB entries are not that many, really).
The name of the newly introduced data structures (dsa_mac_addr) is
chosen in such a way that will be reusable for host FDB entries (next
patch).
With this change, we can finally have the same matching logic for the
MDB additions and deletions, as well as for their host-trapped variants.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-06-29 14:06:50 +00:00
|
|
|
if (err) {
|
2021-10-24 17:17:48 +00:00
|
|
|
refcount_set(&a->refcount, 1);
|
net: dsa: introduce locking for the address lists on CPU and DSA ports
Now that the rtnl_mutex is going away for dsa_port_{host_,}fdb_{add,del},
no one is serializing access to the address lists that DSA keeps for the
purpose of reference counting on shared ports (CPU and cascade ports).
It can happen for one dsa_switch_do_fdb_del to do list_del on a dp->fdbs
element while another dsa_switch_do_fdb_{add,del} is traversing dp->fdbs.
We need to avoid that.
Currently dp->mdbs is not at risk, because dsa_switch_do_mdb_{add,del}
still runs under the rtnl_mutex. But it would be nice if it would not
depend on that being the case. So let's introduce a mutex per port (the
address lists are per port too) and share it between dp->mdbs and
dp->fdbs.
The place where we put the locking is interesting. It could be tempting
to put a DSA-level lock which still serializes calls to
.port_fdb_{add,del}, but it would still not avoid concurrency with other
driver code paths that are currently under rtnl_mutex (.port_fdb_dump,
.port_fast_age). So it would add a very false sense of security (and
adding a global switch-wide lock in DSA to resynchronize with the
rtnl_lock is also counterproductive and hard).
So the locking is intentionally done only where the dp->fdbs and dp->mdbs
lists are traversed. That means, from a driver perspective, that
.port_fdb_add will be called with the dp->addr_lists_lock mutex held on
the CPU port, but not held on user ports. This is done so that driver
writers are not encouraged to rely on any guarantee offered by
dp->addr_lists_lock.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-10-24 17:17:54 +00:00
|
|
|
goto out;
|
net: dsa: reference count the MDB entries at the cross-chip notifier level
Ever since the cross-chip notifiers were introduced, the design was
meant to be simplistic and just get the job done without worrying too
much about dangling resources left behind.
For example, somebody installs an MDB entry on sw0p0 in this daisy chain
topology. It gets installed using ds->ops->port_mdb_add() on sw0p0,
sw1p4 and sw2p4.
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ x ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
Then the same person deletes that MDB entry. The cross-chip notifier for
deletion only matches sw0p0:
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ x ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ ]
Why?
Because the DSA links are 'trunk' ports, if we just go ahead and delete
the MDB from sw1p4 and sw2p4 directly, we might delete those multicast
entries when they are still needed. Just consider the fact that somebody
does:
- add a multicast MAC address towards sw0p0 [ via the cross-chip
notifiers it gets installed on the DSA links too ]
- add the same multicast MAC address towards sw0p1 (another port of that
same switch)
- delete the same multicast MAC address from sw0p0.
At this point, if we deleted the MAC address from the DSA links, it
would be flooded, even though there is still an entry on switch 0 which
needs it not to.
So that is why deletions only match the targeted source port and nothing
on DSA links. Of course, dangling resources means that the hardware
tables will eventually run out given enough additions/removals, but hey,
at least it's simple.
But there is a bigger concern which needs to be addressed, and that is
our support for SWITCHDEV_OBJ_ID_HOST_MDB. DSA simply translates such an
object into a dsa_port_host_mdb_add() which ends up as ds->ops->port_mdb_add()
on the upstream port, and a similar thing happens on deletion:
dsa_port_host_mdb_del() will trigger ds->ops->port_mdb_del() on the
upstream port.
When there are 2 VLAN-unaware bridges spanning the same switch (which is
a use case DSA proudly supports), each bridge will install its own
SWITCHDEV_OBJ_ID_HOST_MDB entries. But upon deletion, DSA goes ahead and
emits a DSA_NOTIFIER_MDB_DEL for dp->cpu_dp, which is shared between the
user ports enslaved to br0 and the user ports enslaved to br1. Not good.
The host-trapped multicast addresses installed by br1 will be deleted
when any state changes in br0 (IGMP timers expire, or ports leave, etc).
To avoid this, we could of course go the route of the zero-sum game and
delete the DSA_NOTIFIER_MDB_DEL call for dp->cpu_dp. But the better
design is to just admit that on shared ports like DSA links and CPU
ports, we should be reference counting calls, even if this consumes some
dynamic memory which DSA has traditionally avoided. On the flip side,
the hardware tables of switches are limited in size, so it would be good
if the OS managed them properly instead of having them eventually
overflow.
To address the memory usage concern, we only apply the refcounting of
MDB entries on ports that are really shared (CPU ports and DSA links)
and not on user ports. In a typical single-switch setup, this means only
the CPU port (and the host MDB entries are not that many, really).
The name of the newly introduced data structures (dsa_mac_addr) is
chosen in such a way that will be reusable for host FDB entries (next
patch).
With this change, we can finally have the same matching logic for the
MDB additions and deletions, as well as for their host-trapped variants.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-06-29 14:06:50 +00:00
|
|
|
}
|
|
|
|
|
|
|
|
list_del(&a->list);
|
|
|
|
kfree(a);
|
|
|
|
|
net: dsa: introduce locking for the address lists on CPU and DSA ports
Now that the rtnl_mutex is going away for dsa_port_{host_,}fdb_{add,del},
no one is serializing access to the address lists that DSA keeps for the
purpose of reference counting on shared ports (CPU and cascade ports).
It can happen for one dsa_switch_do_fdb_del to do list_del on a dp->fdbs
element while another dsa_switch_do_fdb_{add,del} is traversing dp->fdbs.
We need to avoid that.
Currently dp->mdbs is not at risk, because dsa_switch_do_mdb_{add,del}
still runs under the rtnl_mutex. But it would be nice if it would not
depend on that being the case. So let's introduce a mutex per port (the
address lists are per port too) and share it between dp->mdbs and
dp->fdbs.
The place where we put the locking is interesting. It could be tempting
to put a DSA-level lock which still serializes calls to
.port_fdb_{add,del}, but it would still not avoid concurrency with other
driver code paths that are currently under rtnl_mutex (.port_fdb_dump,
.port_fast_age). So it would add a very false sense of security (and
adding a global switch-wide lock in DSA to resynchronize with the
rtnl_lock is also counterproductive and hard).
So the locking is intentionally done only where the dp->fdbs and dp->mdbs
lists are traversed. That means, from a driver perspective, that
.port_fdb_add will be called with the dp->addr_lists_lock mutex held on
the CPU port, but not held on user ports. This is done so that driver
writers are not encouraged to rely on any guarantee offered by
dp->addr_lists_lock.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-10-24 17:17:54 +00:00
|
|
|
out:
|
|
|
|
mutex_unlock(&dp->addr_lists_lock);
|
|
|
|
|
|
|
|
return err;
|
net: dsa: reference count the MDB entries at the cross-chip notifier level
Ever since the cross-chip notifiers were introduced, the design was
meant to be simplistic and just get the job done without worrying too
much about dangling resources left behind.
For example, somebody installs an MDB entry on sw0p0 in this daisy chain
topology. It gets installed using ds->ops->port_mdb_add() on sw0p0,
sw1p4 and sw2p4.
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ x ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
Then the same person deletes that MDB entry. The cross-chip notifier for
deletion only matches sw0p0:
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ x ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ ]
Why?
Because the DSA links are 'trunk' ports, if we just go ahead and delete
the MDB from sw1p4 and sw2p4 directly, we might delete those multicast
entries when they are still needed. Just consider the fact that somebody
does:
- add a multicast MAC address towards sw0p0 [ via the cross-chip
notifiers it gets installed on the DSA links too ]
- add the same multicast MAC address towards sw0p1 (another port of that
same switch)
- delete the same multicast MAC address from sw0p0.
At this point, if we deleted the MAC address from the DSA links, it
would be flooded, even though there is still an entry on switch 0 which
needs it not to.
So that is why deletions only match the targeted source port and nothing
on DSA links. Of course, dangling resources means that the hardware
tables will eventually run out given enough additions/removals, but hey,
at least it's simple.
But there is a bigger concern which needs to be addressed, and that is
our support for SWITCHDEV_OBJ_ID_HOST_MDB. DSA simply translates such an
object into a dsa_port_host_mdb_add() which ends up as ds->ops->port_mdb_add()
on the upstream port, and a similar thing happens on deletion:
dsa_port_host_mdb_del() will trigger ds->ops->port_mdb_del() on the
upstream port.
When there are 2 VLAN-unaware bridges spanning the same switch (which is
a use case DSA proudly supports), each bridge will install its own
SWITCHDEV_OBJ_ID_HOST_MDB entries. But upon deletion, DSA goes ahead and
emits a DSA_NOTIFIER_MDB_DEL for dp->cpu_dp, which is shared between the
user ports enslaved to br0 and the user ports enslaved to br1. Not good.
The host-trapped multicast addresses installed by br1 will be deleted
when any state changes in br0 (IGMP timers expire, or ports leave, etc).
To avoid this, we could of course go the route of the zero-sum game and
delete the DSA_NOTIFIER_MDB_DEL call for dp->cpu_dp. But the better
design is to just admit that on shared ports like DSA links and CPU
ports, we should be reference counting calls, even if this consumes some
dynamic memory which DSA has traditionally avoided. On the flip side,
the hardware tables of switches are limited in size, so it would be good
if the OS managed them properly instead of having them eventually
overflow.
To address the memory usage concern, we only apply the refcounting of
MDB entries on ports that are really shared (CPU ports and DSA links)
and not on user ports. In a typical single-switch setup, this means only
the CPU port (and the host MDB entries are not that many, really).
The name of the newly introduced data structures (dsa_mac_addr) is
chosen in such a way that will be reusable for host FDB entries (next
patch).
With this change, we can finally have the same matching logic for the
MDB additions and deletions, as well as for their host-trapped variants.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-06-29 14:06:50 +00:00
|
|
|
}
|
|
|
|
|
2021-10-20 17:49:53 +00:00
|
|
|
static int dsa_port_do_fdb_add(struct dsa_port *dp, const unsigned char *addr,
|
net: dsa: request drivers to perform FDB isolation
For DSA, to encourage drivers to perform FDB isolation simply means to
track which bridge does each FDB and MDB entry belong to. It then
becomes the driver responsibility to use something that makes the FDB
entry from one bridge not match the FDB lookup of ports from other
bridges.
The top-level functions where the bridge is determined are:
- dsa_port_fdb_{add,del}
- dsa_port_host_fdb_{add,del}
- dsa_port_mdb_{add,del}
- dsa_port_host_mdb_{add,del}
aka the pre-crosschip-notifier functions.
Changing the API to pass a reference to a bridge is not superfluous, and
looking at the passed bridge argument is not the same as having the
driver look at dsa_to_port(ds, port)->bridge from the ->port_fdb_add()
method.
DSA installs FDB and MDB entries on shared (CPU and DSA) ports as well,
and those do not have any dp->bridge information to retrieve, because
they are not in any bridge - they are merely the pipes that serve the
user ports that are in one or multiple bridges.
The struct dsa_bridge associated with each FDB/MDB entry is encapsulated
in a larger "struct dsa_db" database. Although only databases associated
to bridges are notified for now, this API will be the starting point for
implementing IFF_UNICAST_FLT in DSA. There, the idea is to install FDB
entries on the CPU port which belong to the corresponding user port's
port database. These are supposed to match only when the port is
standalone.
It is better to introduce the API in its expected final form than to
introduce it for bridges first, then to have to change drivers which may
have made one or more assumptions.
Drivers can use the provided bridge.num, but they can also use a
different numbering scheme that is more convenient.
DSA must perform refcounting on the CPU and DSA ports by also taking
into account the bridge number. So if two bridges request the same local
address, DSA must notify the driver twice, once for each bridge.
In fact, if the driver supports FDB isolation, DSA must perform
refcounting per bridge, but if the driver doesn't, DSA must refcount
host addresses across all bridges, otherwise it would be telling the
driver to delete an FDB entry for a bridge and the driver would delete
it for all bridges. So introduce a bool fdb_isolation in drivers which
would make all bridge databases passed to the cross-chip notifier have
the same number (0). This makes dsa_mac_addr_find() -> dsa_db_equal()
say that all bridge databases are the same database - which is
essentially the legacy behavior.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-02-25 09:22:22 +00:00
|
|
|
u16 vid, struct dsa_db db)
|
2021-06-29 14:06:52 +00:00
|
|
|
{
|
2021-10-20 17:49:53 +00:00
|
|
|
struct dsa_switch *ds = dp->ds;
|
2021-06-29 14:06:52 +00:00
|
|
|
struct dsa_mac_addr *a;
|
2021-10-20 17:49:53 +00:00
|
|
|
int port = dp->index;
|
net: dsa: introduce locking for the address lists on CPU and DSA ports
Now that the rtnl_mutex is going away for dsa_port_{host_,}fdb_{add,del},
no one is serializing access to the address lists that DSA keeps for the
purpose of reference counting on shared ports (CPU and cascade ports).
It can happen for one dsa_switch_do_fdb_del to do list_del on a dp->fdbs
element while another dsa_switch_do_fdb_{add,del} is traversing dp->fdbs.
We need to avoid that.
Currently dp->mdbs is not at risk, because dsa_switch_do_mdb_{add,del}
still runs under the rtnl_mutex. But it would be nice if it would not
depend on that being the case. So let's introduce a mutex per port (the
address lists are per port too) and share it between dp->mdbs and
dp->fdbs.
The place where we put the locking is interesting. It could be tempting
to put a DSA-level lock which still serializes calls to
.port_fdb_{add,del}, but it would still not avoid concurrency with other
driver code paths that are currently under rtnl_mutex (.port_fdb_dump,
.port_fast_age). So it would add a very false sense of security (and
adding a global switch-wide lock in DSA to resynchronize with the
rtnl_lock is also counterproductive and hard).
So the locking is intentionally done only where the dp->fdbs and dp->mdbs
lists are traversed. That means, from a driver perspective, that
.port_fdb_add will be called with the dp->addr_lists_lock mutex held on
the CPU port, but not held on user ports. This is done so that driver
writers are not encouraged to rely on any guarantee offered by
dp->addr_lists_lock.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-10-24 17:17:54 +00:00
|
|
|
int err = 0;
|
2021-06-29 14:06:52 +00:00
|
|
|
|
|
|
|
/* No need to bother with refcounting for user ports */
|
|
|
|
if (!(dsa_port_is_cpu(dp) || dsa_port_is_dsa(dp)))
|
net: dsa: request drivers to perform FDB isolation
For DSA, to encourage drivers to perform FDB isolation simply means to
track which bridge does each FDB and MDB entry belong to. It then
becomes the driver responsibility to use something that makes the FDB
entry from one bridge not match the FDB lookup of ports from other
bridges.
The top-level functions where the bridge is determined are:
- dsa_port_fdb_{add,del}
- dsa_port_host_fdb_{add,del}
- dsa_port_mdb_{add,del}
- dsa_port_host_mdb_{add,del}
aka the pre-crosschip-notifier functions.
Changing the API to pass a reference to a bridge is not superfluous, and
looking at the passed bridge argument is not the same as having the
driver look at dsa_to_port(ds, port)->bridge from the ->port_fdb_add()
method.
DSA installs FDB and MDB entries on shared (CPU and DSA) ports as well,
and those do not have any dp->bridge information to retrieve, because
they are not in any bridge - they are merely the pipes that serve the
user ports that are in one or multiple bridges.
The struct dsa_bridge associated with each FDB/MDB entry is encapsulated
in a larger "struct dsa_db" database. Although only databases associated
to bridges are notified for now, this API will be the starting point for
implementing IFF_UNICAST_FLT in DSA. There, the idea is to install FDB
entries on the CPU port which belong to the corresponding user port's
port database. These are supposed to match only when the port is
standalone.
It is better to introduce the API in its expected final form than to
introduce it for bridges first, then to have to change drivers which may
have made one or more assumptions.
Drivers can use the provided bridge.num, but they can also use a
different numbering scheme that is more convenient.
DSA must perform refcounting on the CPU and DSA ports by also taking
into account the bridge number. So if two bridges request the same local
address, DSA must notify the driver twice, once for each bridge.
In fact, if the driver supports FDB isolation, DSA must perform
refcounting per bridge, but if the driver doesn't, DSA must refcount
host addresses across all bridges, otherwise it would be telling the
driver to delete an FDB entry for a bridge and the driver would delete
it for all bridges. So introduce a bool fdb_isolation in drivers which
would make all bridge databases passed to the cross-chip notifier have
the same number (0). This makes dsa_mac_addr_find() -> dsa_db_equal()
say that all bridge databases are the same database - which is
essentially the legacy behavior.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-02-25 09:22:22 +00:00
|
|
|
return ds->ops->port_fdb_add(ds, port, addr, vid, db);
|
2021-06-29 14:06:52 +00:00
|
|
|
|
net: dsa: introduce locking for the address lists on CPU and DSA ports
Now that the rtnl_mutex is going away for dsa_port_{host_,}fdb_{add,del},
no one is serializing access to the address lists that DSA keeps for the
purpose of reference counting on shared ports (CPU and cascade ports).
It can happen for one dsa_switch_do_fdb_del to do list_del on a dp->fdbs
element while another dsa_switch_do_fdb_{add,del} is traversing dp->fdbs.
We need to avoid that.
Currently dp->mdbs is not at risk, because dsa_switch_do_mdb_{add,del}
still runs under the rtnl_mutex. But it would be nice if it would not
depend on that being the case. So let's introduce a mutex per port (the
address lists are per port too) and share it between dp->mdbs and
dp->fdbs.
The place where we put the locking is interesting. It could be tempting
to put a DSA-level lock which still serializes calls to
.port_fdb_{add,del}, but it would still not avoid concurrency with other
driver code paths that are currently under rtnl_mutex (.port_fdb_dump,
.port_fast_age). So it would add a very false sense of security (and
adding a global switch-wide lock in DSA to resynchronize with the
rtnl_lock is also counterproductive and hard).
So the locking is intentionally done only where the dp->fdbs and dp->mdbs
lists are traversed. That means, from a driver perspective, that
.port_fdb_add will be called with the dp->addr_lists_lock mutex held on
the CPU port, but not held on user ports. This is done so that driver
writers are not encouraged to rely on any guarantee offered by
dp->addr_lists_lock.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-10-24 17:17:54 +00:00
|
|
|
mutex_lock(&dp->addr_lists_lock);
|
|
|
|
|
net: dsa: request drivers to perform FDB isolation
For DSA, to encourage drivers to perform FDB isolation simply means to
track which bridge does each FDB and MDB entry belong to. It then
becomes the driver responsibility to use something that makes the FDB
entry from one bridge not match the FDB lookup of ports from other
bridges.
The top-level functions where the bridge is determined are:
- dsa_port_fdb_{add,del}
- dsa_port_host_fdb_{add,del}
- dsa_port_mdb_{add,del}
- dsa_port_host_mdb_{add,del}
aka the pre-crosschip-notifier functions.
Changing the API to pass a reference to a bridge is not superfluous, and
looking at the passed bridge argument is not the same as having the
driver look at dsa_to_port(ds, port)->bridge from the ->port_fdb_add()
method.
DSA installs FDB and MDB entries on shared (CPU and DSA) ports as well,
and those do not have any dp->bridge information to retrieve, because
they are not in any bridge - they are merely the pipes that serve the
user ports that are in one or multiple bridges.
The struct dsa_bridge associated with each FDB/MDB entry is encapsulated
in a larger "struct dsa_db" database. Although only databases associated
to bridges are notified for now, this API will be the starting point for
implementing IFF_UNICAST_FLT in DSA. There, the idea is to install FDB
entries on the CPU port which belong to the corresponding user port's
port database. These are supposed to match only when the port is
standalone.
It is better to introduce the API in its expected final form than to
introduce it for bridges first, then to have to change drivers which may
have made one or more assumptions.
Drivers can use the provided bridge.num, but they can also use a
different numbering scheme that is more convenient.
DSA must perform refcounting on the CPU and DSA ports by also taking
into account the bridge number. So if two bridges request the same local
address, DSA must notify the driver twice, once for each bridge.
In fact, if the driver supports FDB isolation, DSA must perform
refcounting per bridge, but if the driver doesn't, DSA must refcount
host addresses across all bridges, otherwise it would be telling the
driver to delete an FDB entry for a bridge and the driver would delete
it for all bridges. So introduce a bool fdb_isolation in drivers which
would make all bridge databases passed to the cross-chip notifier have
the same number (0). This makes dsa_mac_addr_find() -> dsa_db_equal()
say that all bridge databases are the same database - which is
essentially the legacy behavior.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-02-25 09:22:22 +00:00
|
|
|
a = dsa_mac_addr_find(&dp->fdbs, addr, vid, db);
|
2021-06-29 14:06:52 +00:00
|
|
|
if (a) {
|
|
|
|
refcount_inc(&a->refcount);
|
net: dsa: introduce locking for the address lists on CPU and DSA ports
Now that the rtnl_mutex is going away for dsa_port_{host_,}fdb_{add,del},
no one is serializing access to the address lists that DSA keeps for the
purpose of reference counting on shared ports (CPU and cascade ports).
It can happen for one dsa_switch_do_fdb_del to do list_del on a dp->fdbs
element while another dsa_switch_do_fdb_{add,del} is traversing dp->fdbs.
We need to avoid that.
Currently dp->mdbs is not at risk, because dsa_switch_do_mdb_{add,del}
still runs under the rtnl_mutex. But it would be nice if it would not
depend on that being the case. So let's introduce a mutex per port (the
address lists are per port too) and share it between dp->mdbs and
dp->fdbs.
The place where we put the locking is interesting. It could be tempting
to put a DSA-level lock which still serializes calls to
.port_fdb_{add,del}, but it would still not avoid concurrency with other
driver code paths that are currently under rtnl_mutex (.port_fdb_dump,
.port_fast_age). So it would add a very false sense of security (and
adding a global switch-wide lock in DSA to resynchronize with the
rtnl_lock is also counterproductive and hard).
So the locking is intentionally done only where the dp->fdbs and dp->mdbs
lists are traversed. That means, from a driver perspective, that
.port_fdb_add will be called with the dp->addr_lists_lock mutex held on
the CPU port, but not held on user ports. This is done so that driver
writers are not encouraged to rely on any guarantee offered by
dp->addr_lists_lock.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-10-24 17:17:54 +00:00
|
|
|
goto out;
|
2021-06-29 14:06:52 +00:00
|
|
|
}
|
|
|
|
|
|
|
|
a = kzalloc(sizeof(*a), GFP_KERNEL);
|
net: dsa: introduce locking for the address lists on CPU and DSA ports
Now that the rtnl_mutex is going away for dsa_port_{host_,}fdb_{add,del},
no one is serializing access to the address lists that DSA keeps for the
purpose of reference counting on shared ports (CPU and cascade ports).
It can happen for one dsa_switch_do_fdb_del to do list_del on a dp->fdbs
element while another dsa_switch_do_fdb_{add,del} is traversing dp->fdbs.
We need to avoid that.
Currently dp->mdbs is not at risk, because dsa_switch_do_mdb_{add,del}
still runs under the rtnl_mutex. But it would be nice if it would not
depend on that being the case. So let's introduce a mutex per port (the
address lists are per port too) and share it between dp->mdbs and
dp->fdbs.
The place where we put the locking is interesting. It could be tempting
to put a DSA-level lock which still serializes calls to
.port_fdb_{add,del}, but it would still not avoid concurrency with other
driver code paths that are currently under rtnl_mutex (.port_fdb_dump,
.port_fast_age). So it would add a very false sense of security (and
adding a global switch-wide lock in DSA to resynchronize with the
rtnl_lock is also counterproductive and hard).
So the locking is intentionally done only where the dp->fdbs and dp->mdbs
lists are traversed. That means, from a driver perspective, that
.port_fdb_add will be called with the dp->addr_lists_lock mutex held on
the CPU port, but not held on user ports. This is done so that driver
writers are not encouraged to rely on any guarantee offered by
dp->addr_lists_lock.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-10-24 17:17:54 +00:00
|
|
|
if (!a) {
|
|
|
|
err = -ENOMEM;
|
|
|
|
goto out;
|
|
|
|
}
|
2021-06-29 14:06:52 +00:00
|
|
|
|
net: dsa: request drivers to perform FDB isolation
For DSA, to encourage drivers to perform FDB isolation simply means to
track which bridge does each FDB and MDB entry belong to. It then
becomes the driver responsibility to use something that makes the FDB
entry from one bridge not match the FDB lookup of ports from other
bridges.
The top-level functions where the bridge is determined are:
- dsa_port_fdb_{add,del}
- dsa_port_host_fdb_{add,del}
- dsa_port_mdb_{add,del}
- dsa_port_host_mdb_{add,del}
aka the pre-crosschip-notifier functions.
Changing the API to pass a reference to a bridge is not superfluous, and
looking at the passed bridge argument is not the same as having the
driver look at dsa_to_port(ds, port)->bridge from the ->port_fdb_add()
method.
DSA installs FDB and MDB entries on shared (CPU and DSA) ports as well,
and those do not have any dp->bridge information to retrieve, because
they are not in any bridge - they are merely the pipes that serve the
user ports that are in one or multiple bridges.
The struct dsa_bridge associated with each FDB/MDB entry is encapsulated
in a larger "struct dsa_db" database. Although only databases associated
to bridges are notified for now, this API will be the starting point for
implementing IFF_UNICAST_FLT in DSA. There, the idea is to install FDB
entries on the CPU port which belong to the corresponding user port's
port database. These are supposed to match only when the port is
standalone.
It is better to introduce the API in its expected final form than to
introduce it for bridges first, then to have to change drivers which may
have made one or more assumptions.
Drivers can use the provided bridge.num, but they can also use a
different numbering scheme that is more convenient.
DSA must perform refcounting on the CPU and DSA ports by also taking
into account the bridge number. So if two bridges request the same local
address, DSA must notify the driver twice, once for each bridge.
In fact, if the driver supports FDB isolation, DSA must perform
refcounting per bridge, but if the driver doesn't, DSA must refcount
host addresses across all bridges, otherwise it would be telling the
driver to delete an FDB entry for a bridge and the driver would delete
it for all bridges. So introduce a bool fdb_isolation in drivers which
would make all bridge databases passed to the cross-chip notifier have
the same number (0). This makes dsa_mac_addr_find() -> dsa_db_equal()
say that all bridge databases are the same database - which is
essentially the legacy behavior.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-02-25 09:22:22 +00:00
|
|
|
err = ds->ops->port_fdb_add(ds, port, addr, vid, db);
|
2021-06-29 14:06:52 +00:00
|
|
|
if (err) {
|
|
|
|
kfree(a);
|
net: dsa: introduce locking for the address lists on CPU and DSA ports
Now that the rtnl_mutex is going away for dsa_port_{host_,}fdb_{add,del},
no one is serializing access to the address lists that DSA keeps for the
purpose of reference counting on shared ports (CPU and cascade ports).
It can happen for one dsa_switch_do_fdb_del to do list_del on a dp->fdbs
element while another dsa_switch_do_fdb_{add,del} is traversing dp->fdbs.
We need to avoid that.
Currently dp->mdbs is not at risk, because dsa_switch_do_mdb_{add,del}
still runs under the rtnl_mutex. But it would be nice if it would not
depend on that being the case. So let's introduce a mutex per port (the
address lists are per port too) and share it between dp->mdbs and
dp->fdbs.
The place where we put the locking is interesting. It could be tempting
to put a DSA-level lock which still serializes calls to
.port_fdb_{add,del}, but it would still not avoid concurrency with other
driver code paths that are currently under rtnl_mutex (.port_fdb_dump,
.port_fast_age). So it would add a very false sense of security (and
adding a global switch-wide lock in DSA to resynchronize with the
rtnl_lock is also counterproductive and hard).
So the locking is intentionally done only where the dp->fdbs and dp->mdbs
lists are traversed. That means, from a driver perspective, that
.port_fdb_add will be called with the dp->addr_lists_lock mutex held on
the CPU port, but not held on user ports. This is done so that driver
writers are not encouraged to rely on any guarantee offered by
dp->addr_lists_lock.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-10-24 17:17:54 +00:00
|
|
|
goto out;
|
2021-06-29 14:06:52 +00:00
|
|
|
}
|
|
|
|
|
|
|
|
ether_addr_copy(a->addr, addr);
|
|
|
|
a->vid = vid;
|
net: dsa: request drivers to perform FDB isolation
For DSA, to encourage drivers to perform FDB isolation simply means to
track which bridge does each FDB and MDB entry belong to. It then
becomes the driver responsibility to use something that makes the FDB
entry from one bridge not match the FDB lookup of ports from other
bridges.
The top-level functions where the bridge is determined are:
- dsa_port_fdb_{add,del}
- dsa_port_host_fdb_{add,del}
- dsa_port_mdb_{add,del}
- dsa_port_host_mdb_{add,del}
aka the pre-crosschip-notifier functions.
Changing the API to pass a reference to a bridge is not superfluous, and
looking at the passed bridge argument is not the same as having the
driver look at dsa_to_port(ds, port)->bridge from the ->port_fdb_add()
method.
DSA installs FDB and MDB entries on shared (CPU and DSA) ports as well,
and those do not have any dp->bridge information to retrieve, because
they are not in any bridge - they are merely the pipes that serve the
user ports that are in one or multiple bridges.
The struct dsa_bridge associated with each FDB/MDB entry is encapsulated
in a larger "struct dsa_db" database. Although only databases associated
to bridges are notified for now, this API will be the starting point for
implementing IFF_UNICAST_FLT in DSA. There, the idea is to install FDB
entries on the CPU port which belong to the corresponding user port's
port database. These are supposed to match only when the port is
standalone.
It is better to introduce the API in its expected final form than to
introduce it for bridges first, then to have to change drivers which may
have made one or more assumptions.
Drivers can use the provided bridge.num, but they can also use a
different numbering scheme that is more convenient.
DSA must perform refcounting on the CPU and DSA ports by also taking
into account the bridge number. So if two bridges request the same local
address, DSA must notify the driver twice, once for each bridge.
In fact, if the driver supports FDB isolation, DSA must perform
refcounting per bridge, but if the driver doesn't, DSA must refcount
host addresses across all bridges, otherwise it would be telling the
driver to delete an FDB entry for a bridge and the driver would delete
it for all bridges. So introduce a bool fdb_isolation in drivers which
would make all bridge databases passed to the cross-chip notifier have
the same number (0). This makes dsa_mac_addr_find() -> dsa_db_equal()
say that all bridge databases are the same database - which is
essentially the legacy behavior.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-02-25 09:22:22 +00:00
|
|
|
a->db = db;
|
2021-06-29 14:06:52 +00:00
|
|
|
refcount_set(&a->refcount, 1);
|
|
|
|
list_add_tail(&a->list, &dp->fdbs);
|
|
|
|
|
net: dsa: introduce locking for the address lists on CPU and DSA ports
Now that the rtnl_mutex is going away for dsa_port_{host_,}fdb_{add,del},
no one is serializing access to the address lists that DSA keeps for the
purpose of reference counting on shared ports (CPU and cascade ports).
It can happen for one dsa_switch_do_fdb_del to do list_del on a dp->fdbs
element while another dsa_switch_do_fdb_{add,del} is traversing dp->fdbs.
We need to avoid that.
Currently dp->mdbs is not at risk, because dsa_switch_do_mdb_{add,del}
still runs under the rtnl_mutex. But it would be nice if it would not
depend on that being the case. So let's introduce a mutex per port (the
address lists are per port too) and share it between dp->mdbs and
dp->fdbs.
The place where we put the locking is interesting. It could be tempting
to put a DSA-level lock which still serializes calls to
.port_fdb_{add,del}, but it would still not avoid concurrency with other
driver code paths that are currently under rtnl_mutex (.port_fdb_dump,
.port_fast_age). So it would add a very false sense of security (and
adding a global switch-wide lock in DSA to resynchronize with the
rtnl_lock is also counterproductive and hard).
So the locking is intentionally done only where the dp->fdbs and dp->mdbs
lists are traversed. That means, from a driver perspective, that
.port_fdb_add will be called with the dp->addr_lists_lock mutex held on
the CPU port, but not held on user ports. This is done so that driver
writers are not encouraged to rely on any guarantee offered by
dp->addr_lists_lock.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-10-24 17:17:54 +00:00
|
|
|
out:
|
|
|
|
mutex_unlock(&dp->addr_lists_lock);
|
|
|
|
|
|
|
|
return err;
|
2021-06-29 14:06:52 +00:00
|
|
|
}
|
|
|
|
|
2021-10-20 17:49:53 +00:00
|
|
|
static int dsa_port_do_fdb_del(struct dsa_port *dp, const unsigned char *addr,
|
net: dsa: request drivers to perform FDB isolation
For DSA, to encourage drivers to perform FDB isolation simply means to
track which bridge does each FDB and MDB entry belong to. It then
becomes the driver responsibility to use something that makes the FDB
entry from one bridge not match the FDB lookup of ports from other
bridges.
The top-level functions where the bridge is determined are:
- dsa_port_fdb_{add,del}
- dsa_port_host_fdb_{add,del}
- dsa_port_mdb_{add,del}
- dsa_port_host_mdb_{add,del}
aka the pre-crosschip-notifier functions.
Changing the API to pass a reference to a bridge is not superfluous, and
looking at the passed bridge argument is not the same as having the
driver look at dsa_to_port(ds, port)->bridge from the ->port_fdb_add()
method.
DSA installs FDB and MDB entries on shared (CPU and DSA) ports as well,
and those do not have any dp->bridge information to retrieve, because
they are not in any bridge - they are merely the pipes that serve the
user ports that are in one or multiple bridges.
The struct dsa_bridge associated with each FDB/MDB entry is encapsulated
in a larger "struct dsa_db" database. Although only databases associated
to bridges are notified for now, this API will be the starting point for
implementing IFF_UNICAST_FLT in DSA. There, the idea is to install FDB
entries on the CPU port which belong to the corresponding user port's
port database. These are supposed to match only when the port is
standalone.
It is better to introduce the API in its expected final form than to
introduce it for bridges first, then to have to change drivers which may
have made one or more assumptions.
Drivers can use the provided bridge.num, but they can also use a
different numbering scheme that is more convenient.
DSA must perform refcounting on the CPU and DSA ports by also taking
into account the bridge number. So if two bridges request the same local
address, DSA must notify the driver twice, once for each bridge.
In fact, if the driver supports FDB isolation, DSA must perform
refcounting per bridge, but if the driver doesn't, DSA must refcount
host addresses across all bridges, otherwise it would be telling the
driver to delete an FDB entry for a bridge and the driver would delete
it for all bridges. So introduce a bool fdb_isolation in drivers which
would make all bridge databases passed to the cross-chip notifier have
the same number (0). This makes dsa_mac_addr_find() -> dsa_db_equal()
say that all bridge databases are the same database - which is
essentially the legacy behavior.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-02-25 09:22:22 +00:00
|
|
|
u16 vid, struct dsa_db db)
|
2021-06-29 14:06:52 +00:00
|
|
|
{
|
2021-10-20 17:49:53 +00:00
|
|
|
struct dsa_switch *ds = dp->ds;
|
2021-06-29 14:06:52 +00:00
|
|
|
struct dsa_mac_addr *a;
|
2021-10-20 17:49:53 +00:00
|
|
|
int port = dp->index;
|
net: dsa: introduce locking for the address lists on CPU and DSA ports
Now that the rtnl_mutex is going away for dsa_port_{host_,}fdb_{add,del},
no one is serializing access to the address lists that DSA keeps for the
purpose of reference counting on shared ports (CPU and cascade ports).
It can happen for one dsa_switch_do_fdb_del to do list_del on a dp->fdbs
element while another dsa_switch_do_fdb_{add,del} is traversing dp->fdbs.
We need to avoid that.
Currently dp->mdbs is not at risk, because dsa_switch_do_mdb_{add,del}
still runs under the rtnl_mutex. But it would be nice if it would not
depend on that being the case. So let's introduce a mutex per port (the
address lists are per port too) and share it between dp->mdbs and
dp->fdbs.
The place where we put the locking is interesting. It could be tempting
to put a DSA-level lock which still serializes calls to
.port_fdb_{add,del}, but it would still not avoid concurrency with other
driver code paths that are currently under rtnl_mutex (.port_fdb_dump,
.port_fast_age). So it would add a very false sense of security (and
adding a global switch-wide lock in DSA to resynchronize with the
rtnl_lock is also counterproductive and hard).
So the locking is intentionally done only where the dp->fdbs and dp->mdbs
lists are traversed. That means, from a driver perspective, that
.port_fdb_add will be called with the dp->addr_lists_lock mutex held on
the CPU port, but not held on user ports. This is done so that driver
writers are not encouraged to rely on any guarantee offered by
dp->addr_lists_lock.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-10-24 17:17:54 +00:00
|
|
|
int err = 0;
|
2021-06-29 14:06:52 +00:00
|
|
|
|
|
|
|
/* No need to bother with refcounting for user ports */
|
|
|
|
if (!(dsa_port_is_cpu(dp) || dsa_port_is_dsa(dp)))
|
net: dsa: request drivers to perform FDB isolation
For DSA, to encourage drivers to perform FDB isolation simply means to
track which bridge does each FDB and MDB entry belong to. It then
becomes the driver responsibility to use something that makes the FDB
entry from one bridge not match the FDB lookup of ports from other
bridges.
The top-level functions where the bridge is determined are:
- dsa_port_fdb_{add,del}
- dsa_port_host_fdb_{add,del}
- dsa_port_mdb_{add,del}
- dsa_port_host_mdb_{add,del}
aka the pre-crosschip-notifier functions.
Changing the API to pass a reference to a bridge is not superfluous, and
looking at the passed bridge argument is not the same as having the
driver look at dsa_to_port(ds, port)->bridge from the ->port_fdb_add()
method.
DSA installs FDB and MDB entries on shared (CPU and DSA) ports as well,
and those do not have any dp->bridge information to retrieve, because
they are not in any bridge - they are merely the pipes that serve the
user ports that are in one or multiple bridges.
The struct dsa_bridge associated with each FDB/MDB entry is encapsulated
in a larger "struct dsa_db" database. Although only databases associated
to bridges are notified for now, this API will be the starting point for
implementing IFF_UNICAST_FLT in DSA. There, the idea is to install FDB
entries on the CPU port which belong to the corresponding user port's
port database. These are supposed to match only when the port is
standalone.
It is better to introduce the API in its expected final form than to
introduce it for bridges first, then to have to change drivers which may
have made one or more assumptions.
Drivers can use the provided bridge.num, but they can also use a
different numbering scheme that is more convenient.
DSA must perform refcounting on the CPU and DSA ports by also taking
into account the bridge number. So if two bridges request the same local
address, DSA must notify the driver twice, once for each bridge.
In fact, if the driver supports FDB isolation, DSA must perform
refcounting per bridge, but if the driver doesn't, DSA must refcount
host addresses across all bridges, otherwise it would be telling the
driver to delete an FDB entry for a bridge and the driver would delete
it for all bridges. So introduce a bool fdb_isolation in drivers which
would make all bridge databases passed to the cross-chip notifier have
the same number (0). This makes dsa_mac_addr_find() -> dsa_db_equal()
say that all bridge databases are the same database - which is
essentially the legacy behavior.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-02-25 09:22:22 +00:00
|
|
|
return ds->ops->port_fdb_del(ds, port, addr, vid, db);
|
2021-06-29 14:06:52 +00:00
|
|
|
|
net: dsa: introduce locking for the address lists on CPU and DSA ports
Now that the rtnl_mutex is going away for dsa_port_{host_,}fdb_{add,del},
no one is serializing access to the address lists that DSA keeps for the
purpose of reference counting on shared ports (CPU and cascade ports).
It can happen for one dsa_switch_do_fdb_del to do list_del on a dp->fdbs
element while another dsa_switch_do_fdb_{add,del} is traversing dp->fdbs.
We need to avoid that.
Currently dp->mdbs is not at risk, because dsa_switch_do_mdb_{add,del}
still runs under the rtnl_mutex. But it would be nice if it would not
depend on that being the case. So let's introduce a mutex per port (the
address lists are per port too) and share it between dp->mdbs and
dp->fdbs.
The place where we put the locking is interesting. It could be tempting
to put a DSA-level lock which still serializes calls to
.port_fdb_{add,del}, but it would still not avoid concurrency with other
driver code paths that are currently under rtnl_mutex (.port_fdb_dump,
.port_fast_age). So it would add a very false sense of security (and
adding a global switch-wide lock in DSA to resynchronize with the
rtnl_lock is also counterproductive and hard).
So the locking is intentionally done only where the dp->fdbs and dp->mdbs
lists are traversed. That means, from a driver perspective, that
.port_fdb_add will be called with the dp->addr_lists_lock mutex held on
the CPU port, but not held on user ports. This is done so that driver
writers are not encouraged to rely on any guarantee offered by
dp->addr_lists_lock.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-10-24 17:17:54 +00:00
|
|
|
mutex_lock(&dp->addr_lists_lock);
|
|
|
|
|
net: dsa: request drivers to perform FDB isolation
For DSA, to encourage drivers to perform FDB isolation simply means to
track which bridge does each FDB and MDB entry belong to. It then
becomes the driver responsibility to use something that makes the FDB
entry from one bridge not match the FDB lookup of ports from other
bridges.
The top-level functions where the bridge is determined are:
- dsa_port_fdb_{add,del}
- dsa_port_host_fdb_{add,del}
- dsa_port_mdb_{add,del}
- dsa_port_host_mdb_{add,del}
aka the pre-crosschip-notifier functions.
Changing the API to pass a reference to a bridge is not superfluous, and
looking at the passed bridge argument is not the same as having the
driver look at dsa_to_port(ds, port)->bridge from the ->port_fdb_add()
method.
DSA installs FDB and MDB entries on shared (CPU and DSA) ports as well,
and those do not have any dp->bridge information to retrieve, because
they are not in any bridge - they are merely the pipes that serve the
user ports that are in one or multiple bridges.
The struct dsa_bridge associated with each FDB/MDB entry is encapsulated
in a larger "struct dsa_db" database. Although only databases associated
to bridges are notified for now, this API will be the starting point for
implementing IFF_UNICAST_FLT in DSA. There, the idea is to install FDB
entries on the CPU port which belong to the corresponding user port's
port database. These are supposed to match only when the port is
standalone.
It is better to introduce the API in its expected final form than to
introduce it for bridges first, then to have to change drivers which may
have made one or more assumptions.
Drivers can use the provided bridge.num, but they can also use a
different numbering scheme that is more convenient.
DSA must perform refcounting on the CPU and DSA ports by also taking
into account the bridge number. So if two bridges request the same local
address, DSA must notify the driver twice, once for each bridge.
In fact, if the driver supports FDB isolation, DSA must perform
refcounting per bridge, but if the driver doesn't, DSA must refcount
host addresses across all bridges, otherwise it would be telling the
driver to delete an FDB entry for a bridge and the driver would delete
it for all bridges. So introduce a bool fdb_isolation in drivers which
would make all bridge databases passed to the cross-chip notifier have
the same number (0). This makes dsa_mac_addr_find() -> dsa_db_equal()
say that all bridge databases are the same database - which is
essentially the legacy behavior.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-02-25 09:22:22 +00:00
|
|
|
a = dsa_mac_addr_find(&dp->fdbs, addr, vid, db);
|
net: dsa: introduce locking for the address lists on CPU and DSA ports
Now that the rtnl_mutex is going away for dsa_port_{host_,}fdb_{add,del},
no one is serializing access to the address lists that DSA keeps for the
purpose of reference counting on shared ports (CPU and cascade ports).
It can happen for one dsa_switch_do_fdb_del to do list_del on a dp->fdbs
element while another dsa_switch_do_fdb_{add,del} is traversing dp->fdbs.
We need to avoid that.
Currently dp->mdbs is not at risk, because dsa_switch_do_mdb_{add,del}
still runs under the rtnl_mutex. But it would be nice if it would not
depend on that being the case. So let's introduce a mutex per port (the
address lists are per port too) and share it between dp->mdbs and
dp->fdbs.
The place where we put the locking is interesting. It could be tempting
to put a DSA-level lock which still serializes calls to
.port_fdb_{add,del}, but it would still not avoid concurrency with other
driver code paths that are currently under rtnl_mutex (.port_fdb_dump,
.port_fast_age). So it would add a very false sense of security (and
adding a global switch-wide lock in DSA to resynchronize with the
rtnl_lock is also counterproductive and hard).
So the locking is intentionally done only where the dp->fdbs and dp->mdbs
lists are traversed. That means, from a driver perspective, that
.port_fdb_add will be called with the dp->addr_lists_lock mutex held on
the CPU port, but not held on user ports. This is done so that driver
writers are not encouraged to rely on any guarantee offered by
dp->addr_lists_lock.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-10-24 17:17:54 +00:00
|
|
|
if (!a) {
|
|
|
|
err = -ENOENT;
|
|
|
|
goto out;
|
|
|
|
}
|
2021-06-29 14:06:52 +00:00
|
|
|
|
|
|
|
if (!refcount_dec_and_test(&a->refcount))
|
net: dsa: introduce locking for the address lists on CPU and DSA ports
Now that the rtnl_mutex is going away for dsa_port_{host_,}fdb_{add,del},
no one is serializing access to the address lists that DSA keeps for the
purpose of reference counting on shared ports (CPU and cascade ports).
It can happen for one dsa_switch_do_fdb_del to do list_del on a dp->fdbs
element while another dsa_switch_do_fdb_{add,del} is traversing dp->fdbs.
We need to avoid that.
Currently dp->mdbs is not at risk, because dsa_switch_do_mdb_{add,del}
still runs under the rtnl_mutex. But it would be nice if it would not
depend on that being the case. So let's introduce a mutex per port (the
address lists are per port too) and share it between dp->mdbs and
dp->fdbs.
The place where we put the locking is interesting. It could be tempting
to put a DSA-level lock which still serializes calls to
.port_fdb_{add,del}, but it would still not avoid concurrency with other
driver code paths that are currently under rtnl_mutex (.port_fdb_dump,
.port_fast_age). So it would add a very false sense of security (and
adding a global switch-wide lock in DSA to resynchronize with the
rtnl_lock is also counterproductive and hard).
So the locking is intentionally done only where the dp->fdbs and dp->mdbs
lists are traversed. That means, from a driver perspective, that
.port_fdb_add will be called with the dp->addr_lists_lock mutex held on
the CPU port, but not held on user ports. This is done so that driver
writers are not encouraged to rely on any guarantee offered by
dp->addr_lists_lock.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-10-24 17:17:54 +00:00
|
|
|
goto out;
|
2021-06-29 14:06:52 +00:00
|
|
|
|
net: dsa: request drivers to perform FDB isolation
For DSA, to encourage drivers to perform FDB isolation simply means to
track which bridge does each FDB and MDB entry belong to. It then
becomes the driver responsibility to use something that makes the FDB
entry from one bridge not match the FDB lookup of ports from other
bridges.
The top-level functions where the bridge is determined are:
- dsa_port_fdb_{add,del}
- dsa_port_host_fdb_{add,del}
- dsa_port_mdb_{add,del}
- dsa_port_host_mdb_{add,del}
aka the pre-crosschip-notifier functions.
Changing the API to pass a reference to a bridge is not superfluous, and
looking at the passed bridge argument is not the same as having the
driver look at dsa_to_port(ds, port)->bridge from the ->port_fdb_add()
method.
DSA installs FDB and MDB entries on shared (CPU and DSA) ports as well,
and those do not have any dp->bridge information to retrieve, because
they are not in any bridge - they are merely the pipes that serve the
user ports that are in one or multiple bridges.
The struct dsa_bridge associated with each FDB/MDB entry is encapsulated
in a larger "struct dsa_db" database. Although only databases associated
to bridges are notified for now, this API will be the starting point for
implementing IFF_UNICAST_FLT in DSA. There, the idea is to install FDB
entries on the CPU port which belong to the corresponding user port's
port database. These are supposed to match only when the port is
standalone.
It is better to introduce the API in its expected final form than to
introduce it for bridges first, then to have to change drivers which may
have made one or more assumptions.
Drivers can use the provided bridge.num, but they can also use a
different numbering scheme that is more convenient.
DSA must perform refcounting on the CPU and DSA ports by also taking
into account the bridge number. So if two bridges request the same local
address, DSA must notify the driver twice, once for each bridge.
In fact, if the driver supports FDB isolation, DSA must perform
refcounting per bridge, but if the driver doesn't, DSA must refcount
host addresses across all bridges, otherwise it would be telling the
driver to delete an FDB entry for a bridge and the driver would delete
it for all bridges. So introduce a bool fdb_isolation in drivers which
would make all bridge databases passed to the cross-chip notifier have
the same number (0). This makes dsa_mac_addr_find() -> dsa_db_equal()
say that all bridge databases are the same database - which is
essentially the legacy behavior.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-02-25 09:22:22 +00:00
|
|
|
err = ds->ops->port_fdb_del(ds, port, addr, vid, db);
|
2021-06-29 14:06:52 +00:00
|
|
|
if (err) {
|
2021-10-24 17:17:48 +00:00
|
|
|
refcount_set(&a->refcount, 1);
|
net: dsa: introduce locking for the address lists on CPU and DSA ports
Now that the rtnl_mutex is going away for dsa_port_{host_,}fdb_{add,del},
no one is serializing access to the address lists that DSA keeps for the
purpose of reference counting on shared ports (CPU and cascade ports).
It can happen for one dsa_switch_do_fdb_del to do list_del on a dp->fdbs
element while another dsa_switch_do_fdb_{add,del} is traversing dp->fdbs.
We need to avoid that.
Currently dp->mdbs is not at risk, because dsa_switch_do_mdb_{add,del}
still runs under the rtnl_mutex. But it would be nice if it would not
depend on that being the case. So let's introduce a mutex per port (the
address lists are per port too) and share it between dp->mdbs and
dp->fdbs.
The place where we put the locking is interesting. It could be tempting
to put a DSA-level lock which still serializes calls to
.port_fdb_{add,del}, but it would still not avoid concurrency with other
driver code paths that are currently under rtnl_mutex (.port_fdb_dump,
.port_fast_age). So it would add a very false sense of security (and
adding a global switch-wide lock in DSA to resynchronize with the
rtnl_lock is also counterproductive and hard).
So the locking is intentionally done only where the dp->fdbs and dp->mdbs
lists are traversed. That means, from a driver perspective, that
.port_fdb_add will be called with the dp->addr_lists_lock mutex held on
the CPU port, but not held on user ports. This is done so that driver
writers are not encouraged to rely on any guarantee offered by
dp->addr_lists_lock.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-10-24 17:17:54 +00:00
|
|
|
goto out;
|
2021-06-29 14:06:52 +00:00
|
|
|
}
|
|
|
|
|
|
|
|
list_del(&a->list);
|
|
|
|
kfree(a);
|
|
|
|
|
net: dsa: introduce locking for the address lists on CPU and DSA ports
Now that the rtnl_mutex is going away for dsa_port_{host_,}fdb_{add,del},
no one is serializing access to the address lists that DSA keeps for the
purpose of reference counting on shared ports (CPU and cascade ports).
It can happen for one dsa_switch_do_fdb_del to do list_del on a dp->fdbs
element while another dsa_switch_do_fdb_{add,del} is traversing dp->fdbs.
We need to avoid that.
Currently dp->mdbs is not at risk, because dsa_switch_do_mdb_{add,del}
still runs under the rtnl_mutex. But it would be nice if it would not
depend on that being the case. So let's introduce a mutex per port (the
address lists are per port too) and share it between dp->mdbs and
dp->fdbs.
The place where we put the locking is interesting. It could be tempting
to put a DSA-level lock which still serializes calls to
.port_fdb_{add,del}, but it would still not avoid concurrency with other
driver code paths that are currently under rtnl_mutex (.port_fdb_dump,
.port_fast_age). So it would add a very false sense of security (and
adding a global switch-wide lock in DSA to resynchronize with the
rtnl_lock is also counterproductive and hard).
So the locking is intentionally done only where the dp->fdbs and dp->mdbs
lists are traversed. That means, from a driver perspective, that
.port_fdb_add will be called with the dp->addr_lists_lock mutex held on
the CPU port, but not held on user ports. This is done so that driver
writers are not encouraged to rely on any guarantee offered by
dp->addr_lists_lock.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-10-24 17:17:54 +00:00
|
|
|
out:
|
|
|
|
mutex_unlock(&dp->addr_lists_lock);
|
|
|
|
|
|
|
|
return err;
|
2021-06-29 14:06:52 +00:00
|
|
|
}
|
|
|
|
|
net: dsa: support FDB events on offloaded LAG interfaces
This change introduces support for installing static FDB entries towards
a bridge port that is a LAG of multiple DSA switch ports, as well as
support for filtering towards the CPU local FDB entries emitted for LAG
interfaces that are bridge ports.
Conceptually, host addresses on LAG ports are identical to what we do
for plain bridge ports. Whereas FDB entries _towards_ a LAG can't simply
be replicated towards all member ports like we do for multicast, or VLAN.
Instead we need new driver API. Hardware usually considers a LAG to be a
"logical port", and sets the entire LAG as the forwarding destination.
The physical egress port selection within the LAG is made by hashing
policy, as usual.
To represent the logical port corresponding to the LAG, we pass by value
a copy of the dsa_lag structure to all switches in the tree that have at
least one port in that LAG.
To illustrate why a refcounted list of FDB entries is needed in struct
dsa_lag, it is enough to say that:
- a LAG may be a bridge port and may therefore receive FDB events even
while it isn't yet offloaded by any DSA interface
- DSA interfaces may be removed from a LAG while that is a bridge port;
we don't want FDB entries lingering around, but we don't want to
remove entries that are still in use, either
For all the cases below to work, the idea is to always keep an FDB entry
on a LAG with a reference count equal to the DSA member ports. So:
- if a port joins a LAG, it requests the bridge to replay the FDB, and
the FDB entries get created, or their refcount gets bumped by one
- if a port leaves a LAG, the FDB replay deletes or decrements refcount
by one
- if an FDB is installed towards a LAG with ports already present, that
entry is created (if it doesn't exist) and its refcount is bumped by
the amount of ports already present in the LAG
echo "Adding FDB entry to bond with existing ports"
ip link del bond0
ip link add bond0 type bond mode 802.3ad
ip link set swp1 down && ip link set swp1 master bond0 && ip link set swp1 up
ip link set swp2 down && ip link set swp2 master bond0 && ip link set swp2 up
ip link del br0
ip link add br0 type bridge
ip link set bond0 master br0
bridge fdb add dev bond0 00:01:02:03:04:05 master static
ip link del br0
ip link del bond0
echo "Adding FDB entry to empty bond"
ip link del bond0
ip link add bond0 type bond mode 802.3ad
ip link del br0
ip link add br0 type bridge
ip link set bond0 master br0
bridge fdb add dev bond0 00:01:02:03:04:05 master static
ip link set swp1 down && ip link set swp1 master bond0 && ip link set swp1 up
ip link set swp2 down && ip link set swp2 master bond0 && ip link set swp2 up
ip link del br0
ip link del bond0
echo "Adding FDB entry to empty bond, then removing ports one by one"
ip link del bond0
ip link add bond0 type bond mode 802.3ad
ip link del br0
ip link add br0 type bridge
ip link set bond0 master br0
bridge fdb add dev bond0 00:01:02:03:04:05 master static
ip link set swp1 down && ip link set swp1 master bond0 && ip link set swp1 up
ip link set swp2 down && ip link set swp2 master bond0 && ip link set swp2 up
ip link set swp1 nomaster
ip link set swp2 nomaster
ip link del br0
ip link del bond0
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: Jakub Kicinski <kuba@kernel.org>
2022-02-23 14:00:53 +00:00
|
|
|
static int dsa_switch_do_lag_fdb_add(struct dsa_switch *ds, struct dsa_lag *lag,
|
net: dsa: request drivers to perform FDB isolation
For DSA, to encourage drivers to perform FDB isolation simply means to
track which bridge does each FDB and MDB entry belong to. It then
becomes the driver responsibility to use something that makes the FDB
entry from one bridge not match the FDB lookup of ports from other
bridges.
The top-level functions where the bridge is determined are:
- dsa_port_fdb_{add,del}
- dsa_port_host_fdb_{add,del}
- dsa_port_mdb_{add,del}
- dsa_port_host_mdb_{add,del}
aka the pre-crosschip-notifier functions.
Changing the API to pass a reference to a bridge is not superfluous, and
looking at the passed bridge argument is not the same as having the
driver look at dsa_to_port(ds, port)->bridge from the ->port_fdb_add()
method.
DSA installs FDB and MDB entries on shared (CPU and DSA) ports as well,
and those do not have any dp->bridge information to retrieve, because
they are not in any bridge - they are merely the pipes that serve the
user ports that are in one or multiple bridges.
The struct dsa_bridge associated with each FDB/MDB entry is encapsulated
in a larger "struct dsa_db" database. Although only databases associated
to bridges are notified for now, this API will be the starting point for
implementing IFF_UNICAST_FLT in DSA. There, the idea is to install FDB
entries on the CPU port which belong to the corresponding user port's
port database. These are supposed to match only when the port is
standalone.
It is better to introduce the API in its expected final form than to
introduce it for bridges first, then to have to change drivers which may
have made one or more assumptions.
Drivers can use the provided bridge.num, but they can also use a
different numbering scheme that is more convenient.
DSA must perform refcounting on the CPU and DSA ports by also taking
into account the bridge number. So if two bridges request the same local
address, DSA must notify the driver twice, once for each bridge.
In fact, if the driver supports FDB isolation, DSA must perform
refcounting per bridge, but if the driver doesn't, DSA must refcount
host addresses across all bridges, otherwise it would be telling the
driver to delete an FDB entry for a bridge and the driver would delete
it for all bridges. So introduce a bool fdb_isolation in drivers which
would make all bridge databases passed to the cross-chip notifier have
the same number (0). This makes dsa_mac_addr_find() -> dsa_db_equal()
say that all bridge databases are the same database - which is
essentially the legacy behavior.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-02-25 09:22:22 +00:00
|
|
|
const unsigned char *addr, u16 vid,
|
|
|
|
struct dsa_db db)
|
net: dsa: support FDB events on offloaded LAG interfaces
This change introduces support for installing static FDB entries towards
a bridge port that is a LAG of multiple DSA switch ports, as well as
support for filtering towards the CPU local FDB entries emitted for LAG
interfaces that are bridge ports.
Conceptually, host addresses on LAG ports are identical to what we do
for plain bridge ports. Whereas FDB entries _towards_ a LAG can't simply
be replicated towards all member ports like we do for multicast, or VLAN.
Instead we need new driver API. Hardware usually considers a LAG to be a
"logical port", and sets the entire LAG as the forwarding destination.
The physical egress port selection within the LAG is made by hashing
policy, as usual.
To represent the logical port corresponding to the LAG, we pass by value
a copy of the dsa_lag structure to all switches in the tree that have at
least one port in that LAG.
To illustrate why a refcounted list of FDB entries is needed in struct
dsa_lag, it is enough to say that:
- a LAG may be a bridge port and may therefore receive FDB events even
while it isn't yet offloaded by any DSA interface
- DSA interfaces may be removed from a LAG while that is a bridge port;
we don't want FDB entries lingering around, but we don't want to
remove entries that are still in use, either
For all the cases below to work, the idea is to always keep an FDB entry
on a LAG with a reference count equal to the DSA member ports. So:
- if a port joins a LAG, it requests the bridge to replay the FDB, and
the FDB entries get created, or their refcount gets bumped by one
- if a port leaves a LAG, the FDB replay deletes or decrements refcount
by one
- if an FDB is installed towards a LAG with ports already present, that
entry is created (if it doesn't exist) and its refcount is bumped by
the amount of ports already present in the LAG
echo "Adding FDB entry to bond with existing ports"
ip link del bond0
ip link add bond0 type bond mode 802.3ad
ip link set swp1 down && ip link set swp1 master bond0 && ip link set swp1 up
ip link set swp2 down && ip link set swp2 master bond0 && ip link set swp2 up
ip link del br0
ip link add br0 type bridge
ip link set bond0 master br0
bridge fdb add dev bond0 00:01:02:03:04:05 master static
ip link del br0
ip link del bond0
echo "Adding FDB entry to empty bond"
ip link del bond0
ip link add bond0 type bond mode 802.3ad
ip link del br0
ip link add br0 type bridge
ip link set bond0 master br0
bridge fdb add dev bond0 00:01:02:03:04:05 master static
ip link set swp1 down && ip link set swp1 master bond0 && ip link set swp1 up
ip link set swp2 down && ip link set swp2 master bond0 && ip link set swp2 up
ip link del br0
ip link del bond0
echo "Adding FDB entry to empty bond, then removing ports one by one"
ip link del bond0
ip link add bond0 type bond mode 802.3ad
ip link del br0
ip link add br0 type bridge
ip link set bond0 master br0
bridge fdb add dev bond0 00:01:02:03:04:05 master static
ip link set swp1 down && ip link set swp1 master bond0 && ip link set swp1 up
ip link set swp2 down && ip link set swp2 master bond0 && ip link set swp2 up
ip link set swp1 nomaster
ip link set swp2 nomaster
ip link del br0
ip link del bond0
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: Jakub Kicinski <kuba@kernel.org>
2022-02-23 14:00:53 +00:00
|
|
|
{
|
|
|
|
struct dsa_mac_addr *a;
|
|
|
|
int err = 0;
|
|
|
|
|
|
|
|
mutex_lock(&lag->fdb_lock);
|
|
|
|
|
net: dsa: request drivers to perform FDB isolation
For DSA, to encourage drivers to perform FDB isolation simply means to
track which bridge does each FDB and MDB entry belong to. It then
becomes the driver responsibility to use something that makes the FDB
entry from one bridge not match the FDB lookup of ports from other
bridges.
The top-level functions where the bridge is determined are:
- dsa_port_fdb_{add,del}
- dsa_port_host_fdb_{add,del}
- dsa_port_mdb_{add,del}
- dsa_port_host_mdb_{add,del}
aka the pre-crosschip-notifier functions.
Changing the API to pass a reference to a bridge is not superfluous, and
looking at the passed bridge argument is not the same as having the
driver look at dsa_to_port(ds, port)->bridge from the ->port_fdb_add()
method.
DSA installs FDB and MDB entries on shared (CPU and DSA) ports as well,
and those do not have any dp->bridge information to retrieve, because
they are not in any bridge - they are merely the pipes that serve the
user ports that are in one or multiple bridges.
The struct dsa_bridge associated with each FDB/MDB entry is encapsulated
in a larger "struct dsa_db" database. Although only databases associated
to bridges are notified for now, this API will be the starting point for
implementing IFF_UNICAST_FLT in DSA. There, the idea is to install FDB
entries on the CPU port which belong to the corresponding user port's
port database. These are supposed to match only when the port is
standalone.
It is better to introduce the API in its expected final form than to
introduce it for bridges first, then to have to change drivers which may
have made one or more assumptions.
Drivers can use the provided bridge.num, but they can also use a
different numbering scheme that is more convenient.
DSA must perform refcounting on the CPU and DSA ports by also taking
into account the bridge number. So if two bridges request the same local
address, DSA must notify the driver twice, once for each bridge.
In fact, if the driver supports FDB isolation, DSA must perform
refcounting per bridge, but if the driver doesn't, DSA must refcount
host addresses across all bridges, otherwise it would be telling the
driver to delete an FDB entry for a bridge and the driver would delete
it for all bridges. So introduce a bool fdb_isolation in drivers which
would make all bridge databases passed to the cross-chip notifier have
the same number (0). This makes dsa_mac_addr_find() -> dsa_db_equal()
say that all bridge databases are the same database - which is
essentially the legacy behavior.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-02-25 09:22:22 +00:00
|
|
|
a = dsa_mac_addr_find(&lag->fdbs, addr, vid, db);
|
net: dsa: support FDB events on offloaded LAG interfaces
This change introduces support for installing static FDB entries towards
a bridge port that is a LAG of multiple DSA switch ports, as well as
support for filtering towards the CPU local FDB entries emitted for LAG
interfaces that are bridge ports.
Conceptually, host addresses on LAG ports are identical to what we do
for plain bridge ports. Whereas FDB entries _towards_ a LAG can't simply
be replicated towards all member ports like we do for multicast, or VLAN.
Instead we need new driver API. Hardware usually considers a LAG to be a
"logical port", and sets the entire LAG as the forwarding destination.
The physical egress port selection within the LAG is made by hashing
policy, as usual.
To represent the logical port corresponding to the LAG, we pass by value
a copy of the dsa_lag structure to all switches in the tree that have at
least one port in that LAG.
To illustrate why a refcounted list of FDB entries is needed in struct
dsa_lag, it is enough to say that:
- a LAG may be a bridge port and may therefore receive FDB events even
while it isn't yet offloaded by any DSA interface
- DSA interfaces may be removed from a LAG while that is a bridge port;
we don't want FDB entries lingering around, but we don't want to
remove entries that are still in use, either
For all the cases below to work, the idea is to always keep an FDB entry
on a LAG with a reference count equal to the DSA member ports. So:
- if a port joins a LAG, it requests the bridge to replay the FDB, and
the FDB entries get created, or their refcount gets bumped by one
- if a port leaves a LAG, the FDB replay deletes or decrements refcount
by one
- if an FDB is installed towards a LAG with ports already present, that
entry is created (if it doesn't exist) and its refcount is bumped by
the amount of ports already present in the LAG
echo "Adding FDB entry to bond with existing ports"
ip link del bond0
ip link add bond0 type bond mode 802.3ad
ip link set swp1 down && ip link set swp1 master bond0 && ip link set swp1 up
ip link set swp2 down && ip link set swp2 master bond0 && ip link set swp2 up
ip link del br0
ip link add br0 type bridge
ip link set bond0 master br0
bridge fdb add dev bond0 00:01:02:03:04:05 master static
ip link del br0
ip link del bond0
echo "Adding FDB entry to empty bond"
ip link del bond0
ip link add bond0 type bond mode 802.3ad
ip link del br0
ip link add br0 type bridge
ip link set bond0 master br0
bridge fdb add dev bond0 00:01:02:03:04:05 master static
ip link set swp1 down && ip link set swp1 master bond0 && ip link set swp1 up
ip link set swp2 down && ip link set swp2 master bond0 && ip link set swp2 up
ip link del br0
ip link del bond0
echo "Adding FDB entry to empty bond, then removing ports one by one"
ip link del bond0
ip link add bond0 type bond mode 802.3ad
ip link del br0
ip link add br0 type bridge
ip link set bond0 master br0
bridge fdb add dev bond0 00:01:02:03:04:05 master static
ip link set swp1 down && ip link set swp1 master bond0 && ip link set swp1 up
ip link set swp2 down && ip link set swp2 master bond0 && ip link set swp2 up
ip link set swp1 nomaster
ip link set swp2 nomaster
ip link del br0
ip link del bond0
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: Jakub Kicinski <kuba@kernel.org>
2022-02-23 14:00:53 +00:00
|
|
|
if (a) {
|
|
|
|
refcount_inc(&a->refcount);
|
|
|
|
goto out;
|
|
|
|
}
|
|
|
|
|
|
|
|
a = kzalloc(sizeof(*a), GFP_KERNEL);
|
|
|
|
if (!a) {
|
|
|
|
err = -ENOMEM;
|
|
|
|
goto out;
|
|
|
|
}
|
|
|
|
|
net: dsa: request drivers to perform FDB isolation
For DSA, to encourage drivers to perform FDB isolation simply means to
track which bridge does each FDB and MDB entry belong to. It then
becomes the driver responsibility to use something that makes the FDB
entry from one bridge not match the FDB lookup of ports from other
bridges.
The top-level functions where the bridge is determined are:
- dsa_port_fdb_{add,del}
- dsa_port_host_fdb_{add,del}
- dsa_port_mdb_{add,del}
- dsa_port_host_mdb_{add,del}
aka the pre-crosschip-notifier functions.
Changing the API to pass a reference to a bridge is not superfluous, and
looking at the passed bridge argument is not the same as having the
driver look at dsa_to_port(ds, port)->bridge from the ->port_fdb_add()
method.
DSA installs FDB and MDB entries on shared (CPU and DSA) ports as well,
and those do not have any dp->bridge information to retrieve, because
they are not in any bridge - they are merely the pipes that serve the
user ports that are in one or multiple bridges.
The struct dsa_bridge associated with each FDB/MDB entry is encapsulated
in a larger "struct dsa_db" database. Although only databases associated
to bridges are notified for now, this API will be the starting point for
implementing IFF_UNICAST_FLT in DSA. There, the idea is to install FDB
entries on the CPU port which belong to the corresponding user port's
port database. These are supposed to match only when the port is
standalone.
It is better to introduce the API in its expected final form than to
introduce it for bridges first, then to have to change drivers which may
have made one or more assumptions.
Drivers can use the provided bridge.num, but they can also use a
different numbering scheme that is more convenient.
DSA must perform refcounting on the CPU and DSA ports by also taking
into account the bridge number. So if two bridges request the same local
address, DSA must notify the driver twice, once for each bridge.
In fact, if the driver supports FDB isolation, DSA must perform
refcounting per bridge, but if the driver doesn't, DSA must refcount
host addresses across all bridges, otherwise it would be telling the
driver to delete an FDB entry for a bridge and the driver would delete
it for all bridges. So introduce a bool fdb_isolation in drivers which
would make all bridge databases passed to the cross-chip notifier have
the same number (0). This makes dsa_mac_addr_find() -> dsa_db_equal()
say that all bridge databases are the same database - which is
essentially the legacy behavior.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-02-25 09:22:22 +00:00
|
|
|
err = ds->ops->lag_fdb_add(ds, *lag, addr, vid, db);
|
net: dsa: support FDB events on offloaded LAG interfaces
This change introduces support for installing static FDB entries towards
a bridge port that is a LAG of multiple DSA switch ports, as well as
support for filtering towards the CPU local FDB entries emitted for LAG
interfaces that are bridge ports.
Conceptually, host addresses on LAG ports are identical to what we do
for plain bridge ports. Whereas FDB entries _towards_ a LAG can't simply
be replicated towards all member ports like we do for multicast, or VLAN.
Instead we need new driver API. Hardware usually considers a LAG to be a
"logical port", and sets the entire LAG as the forwarding destination.
The physical egress port selection within the LAG is made by hashing
policy, as usual.
To represent the logical port corresponding to the LAG, we pass by value
a copy of the dsa_lag structure to all switches in the tree that have at
least one port in that LAG.
To illustrate why a refcounted list of FDB entries is needed in struct
dsa_lag, it is enough to say that:
- a LAG may be a bridge port and may therefore receive FDB events even
while it isn't yet offloaded by any DSA interface
- DSA interfaces may be removed from a LAG while that is a bridge port;
we don't want FDB entries lingering around, but we don't want to
remove entries that are still in use, either
For all the cases below to work, the idea is to always keep an FDB entry
on a LAG with a reference count equal to the DSA member ports. So:
- if a port joins a LAG, it requests the bridge to replay the FDB, and
the FDB entries get created, or their refcount gets bumped by one
- if a port leaves a LAG, the FDB replay deletes or decrements refcount
by one
- if an FDB is installed towards a LAG with ports already present, that
entry is created (if it doesn't exist) and its refcount is bumped by
the amount of ports already present in the LAG
echo "Adding FDB entry to bond with existing ports"
ip link del bond0
ip link add bond0 type bond mode 802.3ad
ip link set swp1 down && ip link set swp1 master bond0 && ip link set swp1 up
ip link set swp2 down && ip link set swp2 master bond0 && ip link set swp2 up
ip link del br0
ip link add br0 type bridge
ip link set bond0 master br0
bridge fdb add dev bond0 00:01:02:03:04:05 master static
ip link del br0
ip link del bond0
echo "Adding FDB entry to empty bond"
ip link del bond0
ip link add bond0 type bond mode 802.3ad
ip link del br0
ip link add br0 type bridge
ip link set bond0 master br0
bridge fdb add dev bond0 00:01:02:03:04:05 master static
ip link set swp1 down && ip link set swp1 master bond0 && ip link set swp1 up
ip link set swp2 down && ip link set swp2 master bond0 && ip link set swp2 up
ip link del br0
ip link del bond0
echo "Adding FDB entry to empty bond, then removing ports one by one"
ip link del bond0
ip link add bond0 type bond mode 802.3ad
ip link del br0
ip link add br0 type bridge
ip link set bond0 master br0
bridge fdb add dev bond0 00:01:02:03:04:05 master static
ip link set swp1 down && ip link set swp1 master bond0 && ip link set swp1 up
ip link set swp2 down && ip link set swp2 master bond0 && ip link set swp2 up
ip link set swp1 nomaster
ip link set swp2 nomaster
ip link del br0
ip link del bond0
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: Jakub Kicinski <kuba@kernel.org>
2022-02-23 14:00:53 +00:00
|
|
|
if (err) {
|
|
|
|
kfree(a);
|
|
|
|
goto out;
|
|
|
|
}
|
|
|
|
|
|
|
|
ether_addr_copy(a->addr, addr);
|
|
|
|
a->vid = vid;
|
|
|
|
refcount_set(&a->refcount, 1);
|
|
|
|
list_add_tail(&a->list, &lag->fdbs);
|
|
|
|
|
|
|
|
out:
|
|
|
|
mutex_unlock(&lag->fdb_lock);
|
|
|
|
|
|
|
|
return err;
|
|
|
|
}
|
|
|
|
|
|
|
|
static int dsa_switch_do_lag_fdb_del(struct dsa_switch *ds, struct dsa_lag *lag,
|
net: dsa: request drivers to perform FDB isolation
For DSA, to encourage drivers to perform FDB isolation simply means to
track which bridge does each FDB and MDB entry belong to. It then
becomes the driver responsibility to use something that makes the FDB
entry from one bridge not match the FDB lookup of ports from other
bridges.
The top-level functions where the bridge is determined are:
- dsa_port_fdb_{add,del}
- dsa_port_host_fdb_{add,del}
- dsa_port_mdb_{add,del}
- dsa_port_host_mdb_{add,del}
aka the pre-crosschip-notifier functions.
Changing the API to pass a reference to a bridge is not superfluous, and
looking at the passed bridge argument is not the same as having the
driver look at dsa_to_port(ds, port)->bridge from the ->port_fdb_add()
method.
DSA installs FDB and MDB entries on shared (CPU and DSA) ports as well,
and those do not have any dp->bridge information to retrieve, because
they are not in any bridge - they are merely the pipes that serve the
user ports that are in one or multiple bridges.
The struct dsa_bridge associated with each FDB/MDB entry is encapsulated
in a larger "struct dsa_db" database. Although only databases associated
to bridges are notified for now, this API will be the starting point for
implementing IFF_UNICAST_FLT in DSA. There, the idea is to install FDB
entries on the CPU port which belong to the corresponding user port's
port database. These are supposed to match only when the port is
standalone.
It is better to introduce the API in its expected final form than to
introduce it for bridges first, then to have to change drivers which may
have made one or more assumptions.
Drivers can use the provided bridge.num, but they can also use a
different numbering scheme that is more convenient.
DSA must perform refcounting on the CPU and DSA ports by also taking
into account the bridge number. So if two bridges request the same local
address, DSA must notify the driver twice, once for each bridge.
In fact, if the driver supports FDB isolation, DSA must perform
refcounting per bridge, but if the driver doesn't, DSA must refcount
host addresses across all bridges, otherwise it would be telling the
driver to delete an FDB entry for a bridge and the driver would delete
it for all bridges. So introduce a bool fdb_isolation in drivers which
would make all bridge databases passed to the cross-chip notifier have
the same number (0). This makes dsa_mac_addr_find() -> dsa_db_equal()
say that all bridge databases are the same database - which is
essentially the legacy behavior.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-02-25 09:22:22 +00:00
|
|
|
const unsigned char *addr, u16 vid,
|
|
|
|
struct dsa_db db)
|
net: dsa: support FDB events on offloaded LAG interfaces
This change introduces support for installing static FDB entries towards
a bridge port that is a LAG of multiple DSA switch ports, as well as
support for filtering towards the CPU local FDB entries emitted for LAG
interfaces that are bridge ports.
Conceptually, host addresses on LAG ports are identical to what we do
for plain bridge ports. Whereas FDB entries _towards_ a LAG can't simply
be replicated towards all member ports like we do for multicast, or VLAN.
Instead we need new driver API. Hardware usually considers a LAG to be a
"logical port", and sets the entire LAG as the forwarding destination.
The physical egress port selection within the LAG is made by hashing
policy, as usual.
To represent the logical port corresponding to the LAG, we pass by value
a copy of the dsa_lag structure to all switches in the tree that have at
least one port in that LAG.
To illustrate why a refcounted list of FDB entries is needed in struct
dsa_lag, it is enough to say that:
- a LAG may be a bridge port and may therefore receive FDB events even
while it isn't yet offloaded by any DSA interface
- DSA interfaces may be removed from a LAG while that is a bridge port;
we don't want FDB entries lingering around, but we don't want to
remove entries that are still in use, either
For all the cases below to work, the idea is to always keep an FDB entry
on a LAG with a reference count equal to the DSA member ports. So:
- if a port joins a LAG, it requests the bridge to replay the FDB, and
the FDB entries get created, or their refcount gets bumped by one
- if a port leaves a LAG, the FDB replay deletes or decrements refcount
by one
- if an FDB is installed towards a LAG with ports already present, that
entry is created (if it doesn't exist) and its refcount is bumped by
the amount of ports already present in the LAG
echo "Adding FDB entry to bond with existing ports"
ip link del bond0
ip link add bond0 type bond mode 802.3ad
ip link set swp1 down && ip link set swp1 master bond0 && ip link set swp1 up
ip link set swp2 down && ip link set swp2 master bond0 && ip link set swp2 up
ip link del br0
ip link add br0 type bridge
ip link set bond0 master br0
bridge fdb add dev bond0 00:01:02:03:04:05 master static
ip link del br0
ip link del bond0
echo "Adding FDB entry to empty bond"
ip link del bond0
ip link add bond0 type bond mode 802.3ad
ip link del br0
ip link add br0 type bridge
ip link set bond0 master br0
bridge fdb add dev bond0 00:01:02:03:04:05 master static
ip link set swp1 down && ip link set swp1 master bond0 && ip link set swp1 up
ip link set swp2 down && ip link set swp2 master bond0 && ip link set swp2 up
ip link del br0
ip link del bond0
echo "Adding FDB entry to empty bond, then removing ports one by one"
ip link del bond0
ip link add bond0 type bond mode 802.3ad
ip link del br0
ip link add br0 type bridge
ip link set bond0 master br0
bridge fdb add dev bond0 00:01:02:03:04:05 master static
ip link set swp1 down && ip link set swp1 master bond0 && ip link set swp1 up
ip link set swp2 down && ip link set swp2 master bond0 && ip link set swp2 up
ip link set swp1 nomaster
ip link set swp2 nomaster
ip link del br0
ip link del bond0
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: Jakub Kicinski <kuba@kernel.org>
2022-02-23 14:00:53 +00:00
|
|
|
{
|
|
|
|
struct dsa_mac_addr *a;
|
|
|
|
int err = 0;
|
|
|
|
|
|
|
|
mutex_lock(&lag->fdb_lock);
|
|
|
|
|
net: dsa: request drivers to perform FDB isolation
For DSA, to encourage drivers to perform FDB isolation simply means to
track which bridge does each FDB and MDB entry belong to. It then
becomes the driver responsibility to use something that makes the FDB
entry from one bridge not match the FDB lookup of ports from other
bridges.
The top-level functions where the bridge is determined are:
- dsa_port_fdb_{add,del}
- dsa_port_host_fdb_{add,del}
- dsa_port_mdb_{add,del}
- dsa_port_host_mdb_{add,del}
aka the pre-crosschip-notifier functions.
Changing the API to pass a reference to a bridge is not superfluous, and
looking at the passed bridge argument is not the same as having the
driver look at dsa_to_port(ds, port)->bridge from the ->port_fdb_add()
method.
DSA installs FDB and MDB entries on shared (CPU and DSA) ports as well,
and those do not have any dp->bridge information to retrieve, because
they are not in any bridge - they are merely the pipes that serve the
user ports that are in one or multiple bridges.
The struct dsa_bridge associated with each FDB/MDB entry is encapsulated
in a larger "struct dsa_db" database. Although only databases associated
to bridges are notified for now, this API will be the starting point for
implementing IFF_UNICAST_FLT in DSA. There, the idea is to install FDB
entries on the CPU port which belong to the corresponding user port's
port database. These are supposed to match only when the port is
standalone.
It is better to introduce the API in its expected final form than to
introduce it for bridges first, then to have to change drivers which may
have made one or more assumptions.
Drivers can use the provided bridge.num, but they can also use a
different numbering scheme that is more convenient.
DSA must perform refcounting on the CPU and DSA ports by also taking
into account the bridge number. So if two bridges request the same local
address, DSA must notify the driver twice, once for each bridge.
In fact, if the driver supports FDB isolation, DSA must perform
refcounting per bridge, but if the driver doesn't, DSA must refcount
host addresses across all bridges, otherwise it would be telling the
driver to delete an FDB entry for a bridge and the driver would delete
it for all bridges. So introduce a bool fdb_isolation in drivers which
would make all bridge databases passed to the cross-chip notifier have
the same number (0). This makes dsa_mac_addr_find() -> dsa_db_equal()
say that all bridge databases are the same database - which is
essentially the legacy behavior.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-02-25 09:22:22 +00:00
|
|
|
a = dsa_mac_addr_find(&lag->fdbs, addr, vid, db);
|
net: dsa: support FDB events on offloaded LAG interfaces
This change introduces support for installing static FDB entries towards
a bridge port that is a LAG of multiple DSA switch ports, as well as
support for filtering towards the CPU local FDB entries emitted for LAG
interfaces that are bridge ports.
Conceptually, host addresses on LAG ports are identical to what we do
for plain bridge ports. Whereas FDB entries _towards_ a LAG can't simply
be replicated towards all member ports like we do for multicast, or VLAN.
Instead we need new driver API. Hardware usually considers a LAG to be a
"logical port", and sets the entire LAG as the forwarding destination.
The physical egress port selection within the LAG is made by hashing
policy, as usual.
To represent the logical port corresponding to the LAG, we pass by value
a copy of the dsa_lag structure to all switches in the tree that have at
least one port in that LAG.
To illustrate why a refcounted list of FDB entries is needed in struct
dsa_lag, it is enough to say that:
- a LAG may be a bridge port and may therefore receive FDB events even
while it isn't yet offloaded by any DSA interface
- DSA interfaces may be removed from a LAG while that is a bridge port;
we don't want FDB entries lingering around, but we don't want to
remove entries that are still in use, either
For all the cases below to work, the idea is to always keep an FDB entry
on a LAG with a reference count equal to the DSA member ports. So:
- if a port joins a LAG, it requests the bridge to replay the FDB, and
the FDB entries get created, or their refcount gets bumped by one
- if a port leaves a LAG, the FDB replay deletes or decrements refcount
by one
- if an FDB is installed towards a LAG with ports already present, that
entry is created (if it doesn't exist) and its refcount is bumped by
the amount of ports already present in the LAG
echo "Adding FDB entry to bond with existing ports"
ip link del bond0
ip link add bond0 type bond mode 802.3ad
ip link set swp1 down && ip link set swp1 master bond0 && ip link set swp1 up
ip link set swp2 down && ip link set swp2 master bond0 && ip link set swp2 up
ip link del br0
ip link add br0 type bridge
ip link set bond0 master br0
bridge fdb add dev bond0 00:01:02:03:04:05 master static
ip link del br0
ip link del bond0
echo "Adding FDB entry to empty bond"
ip link del bond0
ip link add bond0 type bond mode 802.3ad
ip link del br0
ip link add br0 type bridge
ip link set bond0 master br0
bridge fdb add dev bond0 00:01:02:03:04:05 master static
ip link set swp1 down && ip link set swp1 master bond0 && ip link set swp1 up
ip link set swp2 down && ip link set swp2 master bond0 && ip link set swp2 up
ip link del br0
ip link del bond0
echo "Adding FDB entry to empty bond, then removing ports one by one"
ip link del bond0
ip link add bond0 type bond mode 802.3ad
ip link del br0
ip link add br0 type bridge
ip link set bond0 master br0
bridge fdb add dev bond0 00:01:02:03:04:05 master static
ip link set swp1 down && ip link set swp1 master bond0 && ip link set swp1 up
ip link set swp2 down && ip link set swp2 master bond0 && ip link set swp2 up
ip link set swp1 nomaster
ip link set swp2 nomaster
ip link del br0
ip link del bond0
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: Jakub Kicinski <kuba@kernel.org>
2022-02-23 14:00:53 +00:00
|
|
|
if (!a) {
|
|
|
|
err = -ENOENT;
|
|
|
|
goto out;
|
|
|
|
}
|
|
|
|
|
|
|
|
if (!refcount_dec_and_test(&a->refcount))
|
|
|
|
goto out;
|
|
|
|
|
net: dsa: request drivers to perform FDB isolation
For DSA, to encourage drivers to perform FDB isolation simply means to
track which bridge does each FDB and MDB entry belong to. It then
becomes the driver responsibility to use something that makes the FDB
entry from one bridge not match the FDB lookup of ports from other
bridges.
The top-level functions where the bridge is determined are:
- dsa_port_fdb_{add,del}
- dsa_port_host_fdb_{add,del}
- dsa_port_mdb_{add,del}
- dsa_port_host_mdb_{add,del}
aka the pre-crosschip-notifier functions.
Changing the API to pass a reference to a bridge is not superfluous, and
looking at the passed bridge argument is not the same as having the
driver look at dsa_to_port(ds, port)->bridge from the ->port_fdb_add()
method.
DSA installs FDB and MDB entries on shared (CPU and DSA) ports as well,
and those do not have any dp->bridge information to retrieve, because
they are not in any bridge - they are merely the pipes that serve the
user ports that are in one or multiple bridges.
The struct dsa_bridge associated with each FDB/MDB entry is encapsulated
in a larger "struct dsa_db" database. Although only databases associated
to bridges are notified for now, this API will be the starting point for
implementing IFF_UNICAST_FLT in DSA. There, the idea is to install FDB
entries on the CPU port which belong to the corresponding user port's
port database. These are supposed to match only when the port is
standalone.
It is better to introduce the API in its expected final form than to
introduce it for bridges first, then to have to change drivers which may
have made one or more assumptions.
Drivers can use the provided bridge.num, but they can also use a
different numbering scheme that is more convenient.
DSA must perform refcounting on the CPU and DSA ports by also taking
into account the bridge number. So if two bridges request the same local
address, DSA must notify the driver twice, once for each bridge.
In fact, if the driver supports FDB isolation, DSA must perform
refcounting per bridge, but if the driver doesn't, DSA must refcount
host addresses across all bridges, otherwise it would be telling the
driver to delete an FDB entry for a bridge and the driver would delete
it for all bridges. So introduce a bool fdb_isolation in drivers which
would make all bridge databases passed to the cross-chip notifier have
the same number (0). This makes dsa_mac_addr_find() -> dsa_db_equal()
say that all bridge databases are the same database - which is
essentially the legacy behavior.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-02-25 09:22:22 +00:00
|
|
|
err = ds->ops->lag_fdb_del(ds, *lag, addr, vid, db);
|
net: dsa: support FDB events on offloaded LAG interfaces
This change introduces support for installing static FDB entries towards
a bridge port that is a LAG of multiple DSA switch ports, as well as
support for filtering towards the CPU local FDB entries emitted for LAG
interfaces that are bridge ports.
Conceptually, host addresses on LAG ports are identical to what we do
for plain bridge ports. Whereas FDB entries _towards_ a LAG can't simply
be replicated towards all member ports like we do for multicast, or VLAN.
Instead we need new driver API. Hardware usually considers a LAG to be a
"logical port", and sets the entire LAG as the forwarding destination.
The physical egress port selection within the LAG is made by hashing
policy, as usual.
To represent the logical port corresponding to the LAG, we pass by value
a copy of the dsa_lag structure to all switches in the tree that have at
least one port in that LAG.
To illustrate why a refcounted list of FDB entries is needed in struct
dsa_lag, it is enough to say that:
- a LAG may be a bridge port and may therefore receive FDB events even
while it isn't yet offloaded by any DSA interface
- DSA interfaces may be removed from a LAG while that is a bridge port;
we don't want FDB entries lingering around, but we don't want to
remove entries that are still in use, either
For all the cases below to work, the idea is to always keep an FDB entry
on a LAG with a reference count equal to the DSA member ports. So:
- if a port joins a LAG, it requests the bridge to replay the FDB, and
the FDB entries get created, or their refcount gets bumped by one
- if a port leaves a LAG, the FDB replay deletes or decrements refcount
by one
- if an FDB is installed towards a LAG with ports already present, that
entry is created (if it doesn't exist) and its refcount is bumped by
the amount of ports already present in the LAG
echo "Adding FDB entry to bond with existing ports"
ip link del bond0
ip link add bond0 type bond mode 802.3ad
ip link set swp1 down && ip link set swp1 master bond0 && ip link set swp1 up
ip link set swp2 down && ip link set swp2 master bond0 && ip link set swp2 up
ip link del br0
ip link add br0 type bridge
ip link set bond0 master br0
bridge fdb add dev bond0 00:01:02:03:04:05 master static
ip link del br0
ip link del bond0
echo "Adding FDB entry to empty bond"
ip link del bond0
ip link add bond0 type bond mode 802.3ad
ip link del br0
ip link add br0 type bridge
ip link set bond0 master br0
bridge fdb add dev bond0 00:01:02:03:04:05 master static
ip link set swp1 down && ip link set swp1 master bond0 && ip link set swp1 up
ip link set swp2 down && ip link set swp2 master bond0 && ip link set swp2 up
ip link del br0
ip link del bond0
echo "Adding FDB entry to empty bond, then removing ports one by one"
ip link del bond0
ip link add bond0 type bond mode 802.3ad
ip link del br0
ip link add br0 type bridge
ip link set bond0 master br0
bridge fdb add dev bond0 00:01:02:03:04:05 master static
ip link set swp1 down && ip link set swp1 master bond0 && ip link set swp1 up
ip link set swp2 down && ip link set swp2 master bond0 && ip link set swp2 up
ip link set swp1 nomaster
ip link set swp2 nomaster
ip link del br0
ip link del bond0
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: Jakub Kicinski <kuba@kernel.org>
2022-02-23 14:00:53 +00:00
|
|
|
if (err) {
|
|
|
|
refcount_set(&a->refcount, 1);
|
|
|
|
goto out;
|
|
|
|
}
|
|
|
|
|
|
|
|
list_del(&a->list);
|
|
|
|
kfree(a);
|
|
|
|
|
|
|
|
out:
|
|
|
|
mutex_unlock(&lag->fdb_lock);
|
|
|
|
|
|
|
|
return err;
|
|
|
|
}
|
|
|
|
|
2021-06-29 14:06:51 +00:00
|
|
|
static int dsa_switch_host_fdb_add(struct dsa_switch *ds,
|
|
|
|
struct dsa_notifier_fdb_info *info)
|
|
|
|
{
|
2021-10-20 17:49:53 +00:00
|
|
|
struct dsa_port *dp;
|
2021-06-29 14:06:51 +00:00
|
|
|
int err = 0;
|
|
|
|
|
|
|
|
if (!ds->ops->port_fdb_add)
|
|
|
|
return -EOPNOTSUPP;
|
|
|
|
|
2021-10-20 17:49:53 +00:00
|
|
|
dsa_switch_for_each_port(dp, ds) {
|
net: dsa: make cross-chip notifiers more efficient for host events
To determine whether a given port should react to the port targeted by
the notifier, dsa_port_host_vlan_match() and dsa_port_host_address_match()
look at the positioning of the switch port currently executing the
notifier relative to the switch port for which the notifier was emitted.
To maintain stylistic compatibility with the other match functions from
switch.c, the host address and host VLAN match functions take the
notifier information about targeted port, switch and tree indices as
argument. However, these functions only use that information to retrieve
the struct dsa_port *targeted_dp, which is an invariant for the outer
loop that calls them. So it makes more sense to calculate the targeted
dp only once, and pass it to them as argument.
But furthermore, the targeted dp is actually known at the time the call
to dsa_port_notify() is made. It is just that we decide to only save the
indices of the port, switch and tree in the notifier structure, just to
retrace our steps and find the dp again using dsa_switch_find() and
dsa_to_port().
But both the above functions are relatively expensive, since they need
to iterate through lists. It appears more straightforward to make all
notifiers just pass the targeted dp inside their info structure, and
have the code that needs the indices to look at info->dp->index instead
of info->port, or info->dp->ds->index instead of info->sw_index, or
info->dp->ds->dst->index instead of info->tree_index.
For the sake of consistency, all cross-chip notifiers are converted to
pass the "dp" directly.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-04-15 15:46:22 +00:00
|
|
|
if (dsa_port_host_address_match(dp, info->dp)) {
|
net: dsa: request drivers to perform FDB isolation
For DSA, to encourage drivers to perform FDB isolation simply means to
track which bridge does each FDB and MDB entry belong to. It then
becomes the driver responsibility to use something that makes the FDB
entry from one bridge not match the FDB lookup of ports from other
bridges.
The top-level functions where the bridge is determined are:
- dsa_port_fdb_{add,del}
- dsa_port_host_fdb_{add,del}
- dsa_port_mdb_{add,del}
- dsa_port_host_mdb_{add,del}
aka the pre-crosschip-notifier functions.
Changing the API to pass a reference to a bridge is not superfluous, and
looking at the passed bridge argument is not the same as having the
driver look at dsa_to_port(ds, port)->bridge from the ->port_fdb_add()
method.
DSA installs FDB and MDB entries on shared (CPU and DSA) ports as well,
and those do not have any dp->bridge information to retrieve, because
they are not in any bridge - they are merely the pipes that serve the
user ports that are in one or multiple bridges.
The struct dsa_bridge associated with each FDB/MDB entry is encapsulated
in a larger "struct dsa_db" database. Although only databases associated
to bridges are notified for now, this API will be the starting point for
implementing IFF_UNICAST_FLT in DSA. There, the idea is to install FDB
entries on the CPU port which belong to the corresponding user port's
port database. These are supposed to match only when the port is
standalone.
It is better to introduce the API in its expected final form than to
introduce it for bridges first, then to have to change drivers which may
have made one or more assumptions.
Drivers can use the provided bridge.num, but they can also use a
different numbering scheme that is more convenient.
DSA must perform refcounting on the CPU and DSA ports by also taking
into account the bridge number. So if two bridges request the same local
address, DSA must notify the driver twice, once for each bridge.
In fact, if the driver supports FDB isolation, DSA must perform
refcounting per bridge, but if the driver doesn't, DSA must refcount
host addresses across all bridges, otherwise it would be telling the
driver to delete an FDB entry for a bridge and the driver would delete
it for all bridges. So introduce a bool fdb_isolation in drivers which
would make all bridge databases passed to the cross-chip notifier have
the same number (0). This makes dsa_mac_addr_find() -> dsa_db_equal()
say that all bridge databases are the same database - which is
essentially the legacy behavior.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-02-25 09:22:22 +00:00
|
|
|
err = dsa_port_do_fdb_add(dp, info->addr, info->vid,
|
|
|
|
info->db);
|
2021-06-29 14:06:51 +00:00
|
|
|
if (err)
|
|
|
|
break;
|
|
|
|
}
|
|
|
|
}
|
|
|
|
|
|
|
|
return err;
|
|
|
|
}
|
|
|
|
|
|
|
|
static int dsa_switch_host_fdb_del(struct dsa_switch *ds,
|
|
|
|
struct dsa_notifier_fdb_info *info)
|
|
|
|
{
|
2021-10-20 17:49:53 +00:00
|
|
|
struct dsa_port *dp;
|
2021-06-29 14:06:52 +00:00
|
|
|
int err = 0;
|
|
|
|
|
2021-06-29 14:06:51 +00:00
|
|
|
if (!ds->ops->port_fdb_del)
|
|
|
|
return -EOPNOTSUPP;
|
|
|
|
|
2021-10-20 17:49:53 +00:00
|
|
|
dsa_switch_for_each_port(dp, ds) {
|
net: dsa: make cross-chip notifiers more efficient for host events
To determine whether a given port should react to the port targeted by
the notifier, dsa_port_host_vlan_match() and dsa_port_host_address_match()
look at the positioning of the switch port currently executing the
notifier relative to the switch port for which the notifier was emitted.
To maintain stylistic compatibility with the other match functions from
switch.c, the host address and host VLAN match functions take the
notifier information about targeted port, switch and tree indices as
argument. However, these functions only use that information to retrieve
the struct dsa_port *targeted_dp, which is an invariant for the outer
loop that calls them. So it makes more sense to calculate the targeted
dp only once, and pass it to them as argument.
But furthermore, the targeted dp is actually known at the time the call
to dsa_port_notify() is made. It is just that we decide to only save the
indices of the port, switch and tree in the notifier structure, just to
retrace our steps and find the dp again using dsa_switch_find() and
dsa_to_port().
But both the above functions are relatively expensive, since they need
to iterate through lists. It appears more straightforward to make all
notifiers just pass the targeted dp inside their info structure, and
have the code that needs the indices to look at info->dp->index instead
of info->port, or info->dp->ds->index instead of info->sw_index, or
info->dp->ds->dst->index instead of info->tree_index.
For the sake of consistency, all cross-chip notifiers are converted to
pass the "dp" directly.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-04-15 15:46:22 +00:00
|
|
|
if (dsa_port_host_address_match(dp, info->dp)) {
|
net: dsa: request drivers to perform FDB isolation
For DSA, to encourage drivers to perform FDB isolation simply means to
track which bridge does each FDB and MDB entry belong to. It then
becomes the driver responsibility to use something that makes the FDB
entry from one bridge not match the FDB lookup of ports from other
bridges.
The top-level functions where the bridge is determined are:
- dsa_port_fdb_{add,del}
- dsa_port_host_fdb_{add,del}
- dsa_port_mdb_{add,del}
- dsa_port_host_mdb_{add,del}
aka the pre-crosschip-notifier functions.
Changing the API to pass a reference to a bridge is not superfluous, and
looking at the passed bridge argument is not the same as having the
driver look at dsa_to_port(ds, port)->bridge from the ->port_fdb_add()
method.
DSA installs FDB and MDB entries on shared (CPU and DSA) ports as well,
and those do not have any dp->bridge information to retrieve, because
they are not in any bridge - they are merely the pipes that serve the
user ports that are in one or multiple bridges.
The struct dsa_bridge associated with each FDB/MDB entry is encapsulated
in a larger "struct dsa_db" database. Although only databases associated
to bridges are notified for now, this API will be the starting point for
implementing IFF_UNICAST_FLT in DSA. There, the idea is to install FDB
entries on the CPU port which belong to the corresponding user port's
port database. These are supposed to match only when the port is
standalone.
It is better to introduce the API in its expected final form than to
introduce it for bridges first, then to have to change drivers which may
have made one or more assumptions.
Drivers can use the provided bridge.num, but they can also use a
different numbering scheme that is more convenient.
DSA must perform refcounting on the CPU and DSA ports by also taking
into account the bridge number. So if two bridges request the same local
address, DSA must notify the driver twice, once for each bridge.
In fact, if the driver supports FDB isolation, DSA must perform
refcounting per bridge, but if the driver doesn't, DSA must refcount
host addresses across all bridges, otherwise it would be telling the
driver to delete an FDB entry for a bridge and the driver would delete
it for all bridges. So introduce a bool fdb_isolation in drivers which
would make all bridge databases passed to the cross-chip notifier have
the same number (0). This makes dsa_mac_addr_find() -> dsa_db_equal()
say that all bridge databases are the same database - which is
essentially the legacy behavior.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-02-25 09:22:22 +00:00
|
|
|
err = dsa_port_do_fdb_del(dp, info->addr, info->vid,
|
|
|
|
info->db);
|
2021-06-29 14:06:52 +00:00
|
|
|
if (err)
|
|
|
|
break;
|
|
|
|
}
|
|
|
|
}
|
2021-06-29 14:06:51 +00:00
|
|
|
|
2021-06-29 14:06:52 +00:00
|
|
|
return err;
|
2021-06-29 14:06:51 +00:00
|
|
|
}
|
|
|
|
|
2017-05-19 21:00:53 +00:00
|
|
|
static int dsa_switch_fdb_add(struct dsa_switch *ds,
|
|
|
|
struct dsa_notifier_fdb_info *info)
|
|
|
|
{
|
net: dsa: make cross-chip notifiers more efficient for host events
To determine whether a given port should react to the port targeted by
the notifier, dsa_port_host_vlan_match() and dsa_port_host_address_match()
look at the positioning of the switch port currently executing the
notifier relative to the switch port for which the notifier was emitted.
To maintain stylistic compatibility with the other match functions from
switch.c, the host address and host VLAN match functions take the
notifier information about targeted port, switch and tree indices as
argument. However, these functions only use that information to retrieve
the struct dsa_port *targeted_dp, which is an invariant for the outer
loop that calls them. So it makes more sense to calculate the targeted
dp only once, and pass it to them as argument.
But furthermore, the targeted dp is actually known at the time the call
to dsa_port_notify() is made. It is just that we decide to only save the
indices of the port, switch and tree in the notifier structure, just to
retrace our steps and find the dp again using dsa_switch_find() and
dsa_to_port().
But both the above functions are relatively expensive, since they need
to iterate through lists. It appears more straightforward to make all
notifiers just pass the targeted dp inside their info structure, and
have the code that needs the indices to look at info->dp->index instead
of info->port, or info->dp->ds->index instead of info->sw_index, or
info->dp->ds->dst->index instead of info->tree_index.
For the sake of consistency, all cross-chip notifiers are converted to
pass the "dp" directly.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-04-15 15:46:22 +00:00
|
|
|
int port = dsa_towards_port(ds, info->dp->ds->index, info->dp->index);
|
2021-10-20 17:49:53 +00:00
|
|
|
struct dsa_port *dp = dsa_to_port(ds, port);
|
2017-05-19 21:00:53 +00:00
|
|
|
|
2017-08-06 13:15:40 +00:00
|
|
|
if (!ds->ops->port_fdb_add)
|
|
|
|
return -EOPNOTSUPP;
|
2017-05-19 21:00:53 +00:00
|
|
|
|
net: dsa: request drivers to perform FDB isolation
For DSA, to encourage drivers to perform FDB isolation simply means to
track which bridge does each FDB and MDB entry belong to. It then
becomes the driver responsibility to use something that makes the FDB
entry from one bridge not match the FDB lookup of ports from other
bridges.
The top-level functions where the bridge is determined are:
- dsa_port_fdb_{add,del}
- dsa_port_host_fdb_{add,del}
- dsa_port_mdb_{add,del}
- dsa_port_host_mdb_{add,del}
aka the pre-crosschip-notifier functions.
Changing the API to pass a reference to a bridge is not superfluous, and
looking at the passed bridge argument is not the same as having the
driver look at dsa_to_port(ds, port)->bridge from the ->port_fdb_add()
method.
DSA installs FDB and MDB entries on shared (CPU and DSA) ports as well,
and those do not have any dp->bridge information to retrieve, because
they are not in any bridge - they are merely the pipes that serve the
user ports that are in one or multiple bridges.
The struct dsa_bridge associated with each FDB/MDB entry is encapsulated
in a larger "struct dsa_db" database. Although only databases associated
to bridges are notified for now, this API will be the starting point for
implementing IFF_UNICAST_FLT in DSA. There, the idea is to install FDB
entries on the CPU port which belong to the corresponding user port's
port database. These are supposed to match only when the port is
standalone.
It is better to introduce the API in its expected final form than to
introduce it for bridges first, then to have to change drivers which may
have made one or more assumptions.
Drivers can use the provided bridge.num, but they can also use a
different numbering scheme that is more convenient.
DSA must perform refcounting on the CPU and DSA ports by also taking
into account the bridge number. So if two bridges request the same local
address, DSA must notify the driver twice, once for each bridge.
In fact, if the driver supports FDB isolation, DSA must perform
refcounting per bridge, but if the driver doesn't, DSA must refcount
host addresses across all bridges, otherwise it would be telling the
driver to delete an FDB entry for a bridge and the driver would delete
it for all bridges. So introduce a bool fdb_isolation in drivers which
would make all bridge databases passed to the cross-chip notifier have
the same number (0). This makes dsa_mac_addr_find() -> dsa_db_equal()
say that all bridge databases are the same database - which is
essentially the legacy behavior.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-02-25 09:22:22 +00:00
|
|
|
return dsa_port_do_fdb_add(dp, info->addr, info->vid, info->db);
|
2017-05-19 21:00:53 +00:00
|
|
|
}
|
|
|
|
|
|
|
|
static int dsa_switch_fdb_del(struct dsa_switch *ds,
|
|
|
|
struct dsa_notifier_fdb_info *info)
|
|
|
|
{
|
net: dsa: make cross-chip notifiers more efficient for host events
To determine whether a given port should react to the port targeted by
the notifier, dsa_port_host_vlan_match() and dsa_port_host_address_match()
look at the positioning of the switch port currently executing the
notifier relative to the switch port for which the notifier was emitted.
To maintain stylistic compatibility with the other match functions from
switch.c, the host address and host VLAN match functions take the
notifier information about targeted port, switch and tree indices as
argument. However, these functions only use that information to retrieve
the struct dsa_port *targeted_dp, which is an invariant for the outer
loop that calls them. So it makes more sense to calculate the targeted
dp only once, and pass it to them as argument.
But furthermore, the targeted dp is actually known at the time the call
to dsa_port_notify() is made. It is just that we decide to only save the
indices of the port, switch and tree in the notifier structure, just to
retrace our steps and find the dp again using dsa_switch_find() and
dsa_to_port().
But both the above functions are relatively expensive, since they need
to iterate through lists. It appears more straightforward to make all
notifiers just pass the targeted dp inside their info structure, and
have the code that needs the indices to look at info->dp->index instead
of info->port, or info->dp->ds->index instead of info->sw_index, or
info->dp->ds->dst->index instead of info->tree_index.
For the sake of consistency, all cross-chip notifiers are converted to
pass the "dp" directly.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-04-15 15:46:22 +00:00
|
|
|
int port = dsa_towards_port(ds, info->dp->ds->index, info->dp->index);
|
2021-10-20 17:49:53 +00:00
|
|
|
struct dsa_port *dp = dsa_to_port(ds, port);
|
2017-05-19 21:00:53 +00:00
|
|
|
|
|
|
|
if (!ds->ops->port_fdb_del)
|
|
|
|
return -EOPNOTSUPP;
|
|
|
|
|
net: dsa: request drivers to perform FDB isolation
For DSA, to encourage drivers to perform FDB isolation simply means to
track which bridge does each FDB and MDB entry belong to. It then
becomes the driver responsibility to use something that makes the FDB
entry from one bridge not match the FDB lookup of ports from other
bridges.
The top-level functions where the bridge is determined are:
- dsa_port_fdb_{add,del}
- dsa_port_host_fdb_{add,del}
- dsa_port_mdb_{add,del}
- dsa_port_host_mdb_{add,del}
aka the pre-crosschip-notifier functions.
Changing the API to pass a reference to a bridge is not superfluous, and
looking at the passed bridge argument is not the same as having the
driver look at dsa_to_port(ds, port)->bridge from the ->port_fdb_add()
method.
DSA installs FDB and MDB entries on shared (CPU and DSA) ports as well,
and those do not have any dp->bridge information to retrieve, because
they are not in any bridge - they are merely the pipes that serve the
user ports that are in one or multiple bridges.
The struct dsa_bridge associated with each FDB/MDB entry is encapsulated
in a larger "struct dsa_db" database. Although only databases associated
to bridges are notified for now, this API will be the starting point for
implementing IFF_UNICAST_FLT in DSA. There, the idea is to install FDB
entries on the CPU port which belong to the corresponding user port's
port database. These are supposed to match only when the port is
standalone.
It is better to introduce the API in its expected final form than to
introduce it for bridges first, then to have to change drivers which may
have made one or more assumptions.
Drivers can use the provided bridge.num, but they can also use a
different numbering scheme that is more convenient.
DSA must perform refcounting on the CPU and DSA ports by also taking
into account the bridge number. So if two bridges request the same local
address, DSA must notify the driver twice, once for each bridge.
In fact, if the driver supports FDB isolation, DSA must perform
refcounting per bridge, but if the driver doesn't, DSA must refcount
host addresses across all bridges, otherwise it would be telling the
driver to delete an FDB entry for a bridge and the driver would delete
it for all bridges. So introduce a bool fdb_isolation in drivers which
would make all bridge databases passed to the cross-chip notifier have
the same number (0). This makes dsa_mac_addr_find() -> dsa_db_equal()
say that all bridge databases are the same database - which is
essentially the legacy behavior.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-02-25 09:22:22 +00:00
|
|
|
return dsa_port_do_fdb_del(dp, info->addr, info->vid, info->db);
|
2017-05-19 21:00:53 +00:00
|
|
|
}
|
|
|
|
|
net: dsa: support FDB events on offloaded LAG interfaces
This change introduces support for installing static FDB entries towards
a bridge port that is a LAG of multiple DSA switch ports, as well as
support for filtering towards the CPU local FDB entries emitted for LAG
interfaces that are bridge ports.
Conceptually, host addresses on LAG ports are identical to what we do
for plain bridge ports. Whereas FDB entries _towards_ a LAG can't simply
be replicated towards all member ports like we do for multicast, or VLAN.
Instead we need new driver API. Hardware usually considers a LAG to be a
"logical port", and sets the entire LAG as the forwarding destination.
The physical egress port selection within the LAG is made by hashing
policy, as usual.
To represent the logical port corresponding to the LAG, we pass by value
a copy of the dsa_lag structure to all switches in the tree that have at
least one port in that LAG.
To illustrate why a refcounted list of FDB entries is needed in struct
dsa_lag, it is enough to say that:
- a LAG may be a bridge port and may therefore receive FDB events even
while it isn't yet offloaded by any DSA interface
- DSA interfaces may be removed from a LAG while that is a bridge port;
we don't want FDB entries lingering around, but we don't want to
remove entries that are still in use, either
For all the cases below to work, the idea is to always keep an FDB entry
on a LAG with a reference count equal to the DSA member ports. So:
- if a port joins a LAG, it requests the bridge to replay the FDB, and
the FDB entries get created, or their refcount gets bumped by one
- if a port leaves a LAG, the FDB replay deletes or decrements refcount
by one
- if an FDB is installed towards a LAG with ports already present, that
entry is created (if it doesn't exist) and its refcount is bumped by
the amount of ports already present in the LAG
echo "Adding FDB entry to bond with existing ports"
ip link del bond0
ip link add bond0 type bond mode 802.3ad
ip link set swp1 down && ip link set swp1 master bond0 && ip link set swp1 up
ip link set swp2 down && ip link set swp2 master bond0 && ip link set swp2 up
ip link del br0
ip link add br0 type bridge
ip link set bond0 master br0
bridge fdb add dev bond0 00:01:02:03:04:05 master static
ip link del br0
ip link del bond0
echo "Adding FDB entry to empty bond"
ip link del bond0
ip link add bond0 type bond mode 802.3ad
ip link del br0
ip link add br0 type bridge
ip link set bond0 master br0
bridge fdb add dev bond0 00:01:02:03:04:05 master static
ip link set swp1 down && ip link set swp1 master bond0 && ip link set swp1 up
ip link set swp2 down && ip link set swp2 master bond0 && ip link set swp2 up
ip link del br0
ip link del bond0
echo "Adding FDB entry to empty bond, then removing ports one by one"
ip link del bond0
ip link add bond0 type bond mode 802.3ad
ip link del br0
ip link add br0 type bridge
ip link set bond0 master br0
bridge fdb add dev bond0 00:01:02:03:04:05 master static
ip link set swp1 down && ip link set swp1 master bond0 && ip link set swp1 up
ip link set swp2 down && ip link set swp2 master bond0 && ip link set swp2 up
ip link set swp1 nomaster
ip link set swp2 nomaster
ip link del br0
ip link del bond0
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: Jakub Kicinski <kuba@kernel.org>
2022-02-23 14:00:53 +00:00
|
|
|
static int dsa_switch_lag_fdb_add(struct dsa_switch *ds,
|
|
|
|
struct dsa_notifier_lag_fdb_info *info)
|
|
|
|
{
|
|
|
|
struct dsa_port *dp;
|
|
|
|
|
|
|
|
if (!ds->ops->lag_fdb_add)
|
|
|
|
return -EOPNOTSUPP;
|
|
|
|
|
|
|
|
/* Notify switch only if it has a port in this LAG */
|
|
|
|
dsa_switch_for_each_port(dp, ds)
|
|
|
|
if (dsa_port_offloads_lag(dp, info->lag))
|
|
|
|
return dsa_switch_do_lag_fdb_add(ds, info->lag,
|
net: dsa: request drivers to perform FDB isolation
For DSA, to encourage drivers to perform FDB isolation simply means to
track which bridge does each FDB and MDB entry belong to. It then
becomes the driver responsibility to use something that makes the FDB
entry from one bridge not match the FDB lookup of ports from other
bridges.
The top-level functions where the bridge is determined are:
- dsa_port_fdb_{add,del}
- dsa_port_host_fdb_{add,del}
- dsa_port_mdb_{add,del}
- dsa_port_host_mdb_{add,del}
aka the pre-crosschip-notifier functions.
Changing the API to pass a reference to a bridge is not superfluous, and
looking at the passed bridge argument is not the same as having the
driver look at dsa_to_port(ds, port)->bridge from the ->port_fdb_add()
method.
DSA installs FDB and MDB entries on shared (CPU and DSA) ports as well,
and those do not have any dp->bridge information to retrieve, because
they are not in any bridge - they are merely the pipes that serve the
user ports that are in one or multiple bridges.
The struct dsa_bridge associated with each FDB/MDB entry is encapsulated
in a larger "struct dsa_db" database. Although only databases associated
to bridges are notified for now, this API will be the starting point for
implementing IFF_UNICAST_FLT in DSA. There, the idea is to install FDB
entries on the CPU port which belong to the corresponding user port's
port database. These are supposed to match only when the port is
standalone.
It is better to introduce the API in its expected final form than to
introduce it for bridges first, then to have to change drivers which may
have made one or more assumptions.
Drivers can use the provided bridge.num, but they can also use a
different numbering scheme that is more convenient.
DSA must perform refcounting on the CPU and DSA ports by also taking
into account the bridge number. So if two bridges request the same local
address, DSA must notify the driver twice, once for each bridge.
In fact, if the driver supports FDB isolation, DSA must perform
refcounting per bridge, but if the driver doesn't, DSA must refcount
host addresses across all bridges, otherwise it would be telling the
driver to delete an FDB entry for a bridge and the driver would delete
it for all bridges. So introduce a bool fdb_isolation in drivers which
would make all bridge databases passed to the cross-chip notifier have
the same number (0). This makes dsa_mac_addr_find() -> dsa_db_equal()
say that all bridge databases are the same database - which is
essentially the legacy behavior.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-02-25 09:22:22 +00:00
|
|
|
info->addr, info->vid,
|
|
|
|
info->db);
|
net: dsa: support FDB events on offloaded LAG interfaces
This change introduces support for installing static FDB entries towards
a bridge port that is a LAG of multiple DSA switch ports, as well as
support for filtering towards the CPU local FDB entries emitted for LAG
interfaces that are bridge ports.
Conceptually, host addresses on LAG ports are identical to what we do
for plain bridge ports. Whereas FDB entries _towards_ a LAG can't simply
be replicated towards all member ports like we do for multicast, or VLAN.
Instead we need new driver API. Hardware usually considers a LAG to be a
"logical port", and sets the entire LAG as the forwarding destination.
The physical egress port selection within the LAG is made by hashing
policy, as usual.
To represent the logical port corresponding to the LAG, we pass by value
a copy of the dsa_lag structure to all switches in the tree that have at
least one port in that LAG.
To illustrate why a refcounted list of FDB entries is needed in struct
dsa_lag, it is enough to say that:
- a LAG may be a bridge port and may therefore receive FDB events even
while it isn't yet offloaded by any DSA interface
- DSA interfaces may be removed from a LAG while that is a bridge port;
we don't want FDB entries lingering around, but we don't want to
remove entries that are still in use, either
For all the cases below to work, the idea is to always keep an FDB entry
on a LAG with a reference count equal to the DSA member ports. So:
- if a port joins a LAG, it requests the bridge to replay the FDB, and
the FDB entries get created, or their refcount gets bumped by one
- if a port leaves a LAG, the FDB replay deletes or decrements refcount
by one
- if an FDB is installed towards a LAG with ports already present, that
entry is created (if it doesn't exist) and its refcount is bumped by
the amount of ports already present in the LAG
echo "Adding FDB entry to bond with existing ports"
ip link del bond0
ip link add bond0 type bond mode 802.3ad
ip link set swp1 down && ip link set swp1 master bond0 && ip link set swp1 up
ip link set swp2 down && ip link set swp2 master bond0 && ip link set swp2 up
ip link del br0
ip link add br0 type bridge
ip link set bond0 master br0
bridge fdb add dev bond0 00:01:02:03:04:05 master static
ip link del br0
ip link del bond0
echo "Adding FDB entry to empty bond"
ip link del bond0
ip link add bond0 type bond mode 802.3ad
ip link del br0
ip link add br0 type bridge
ip link set bond0 master br0
bridge fdb add dev bond0 00:01:02:03:04:05 master static
ip link set swp1 down && ip link set swp1 master bond0 && ip link set swp1 up
ip link set swp2 down && ip link set swp2 master bond0 && ip link set swp2 up
ip link del br0
ip link del bond0
echo "Adding FDB entry to empty bond, then removing ports one by one"
ip link del bond0
ip link add bond0 type bond mode 802.3ad
ip link del br0
ip link add br0 type bridge
ip link set bond0 master br0
bridge fdb add dev bond0 00:01:02:03:04:05 master static
ip link set swp1 down && ip link set swp1 master bond0 && ip link set swp1 up
ip link set swp2 down && ip link set swp2 master bond0 && ip link set swp2 up
ip link set swp1 nomaster
ip link set swp2 nomaster
ip link del br0
ip link del bond0
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: Jakub Kicinski <kuba@kernel.org>
2022-02-23 14:00:53 +00:00
|
|
|
|
|
|
|
return 0;
|
|
|
|
}
|
|
|
|
|
|
|
|
static int dsa_switch_lag_fdb_del(struct dsa_switch *ds,
|
|
|
|
struct dsa_notifier_lag_fdb_info *info)
|
|
|
|
{
|
|
|
|
struct dsa_port *dp;
|
|
|
|
|
|
|
|
if (!ds->ops->lag_fdb_del)
|
|
|
|
return -EOPNOTSUPP;
|
|
|
|
|
|
|
|
/* Notify switch only if it has a port in this LAG */
|
|
|
|
dsa_switch_for_each_port(dp, ds)
|
|
|
|
if (dsa_port_offloads_lag(dp, info->lag))
|
|
|
|
return dsa_switch_do_lag_fdb_del(ds, info->lag,
|
net: dsa: request drivers to perform FDB isolation
For DSA, to encourage drivers to perform FDB isolation simply means to
track which bridge does each FDB and MDB entry belong to. It then
becomes the driver responsibility to use something that makes the FDB
entry from one bridge not match the FDB lookup of ports from other
bridges.
The top-level functions where the bridge is determined are:
- dsa_port_fdb_{add,del}
- dsa_port_host_fdb_{add,del}
- dsa_port_mdb_{add,del}
- dsa_port_host_mdb_{add,del}
aka the pre-crosschip-notifier functions.
Changing the API to pass a reference to a bridge is not superfluous, and
looking at the passed bridge argument is not the same as having the
driver look at dsa_to_port(ds, port)->bridge from the ->port_fdb_add()
method.
DSA installs FDB and MDB entries on shared (CPU and DSA) ports as well,
and those do not have any dp->bridge information to retrieve, because
they are not in any bridge - they are merely the pipes that serve the
user ports that are in one or multiple bridges.
The struct dsa_bridge associated with each FDB/MDB entry is encapsulated
in a larger "struct dsa_db" database. Although only databases associated
to bridges are notified for now, this API will be the starting point for
implementing IFF_UNICAST_FLT in DSA. There, the idea is to install FDB
entries on the CPU port which belong to the corresponding user port's
port database. These are supposed to match only when the port is
standalone.
It is better to introduce the API in its expected final form than to
introduce it for bridges first, then to have to change drivers which may
have made one or more assumptions.
Drivers can use the provided bridge.num, but they can also use a
different numbering scheme that is more convenient.
DSA must perform refcounting on the CPU and DSA ports by also taking
into account the bridge number. So if two bridges request the same local
address, DSA must notify the driver twice, once for each bridge.
In fact, if the driver supports FDB isolation, DSA must perform
refcounting per bridge, but if the driver doesn't, DSA must refcount
host addresses across all bridges, otherwise it would be telling the
driver to delete an FDB entry for a bridge and the driver would delete
it for all bridges. So introduce a bool fdb_isolation in drivers which
would make all bridge databases passed to the cross-chip notifier have
the same number (0). This makes dsa_mac_addr_find() -> dsa_db_equal()
say that all bridge databases are the same database - which is
essentially the legacy behavior.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-02-25 09:22:22 +00:00
|
|
|
info->addr, info->vid,
|
|
|
|
info->db);
|
net: dsa: support FDB events on offloaded LAG interfaces
This change introduces support for installing static FDB entries towards
a bridge port that is a LAG of multiple DSA switch ports, as well as
support for filtering towards the CPU local FDB entries emitted for LAG
interfaces that are bridge ports.
Conceptually, host addresses on LAG ports are identical to what we do
for plain bridge ports. Whereas FDB entries _towards_ a LAG can't simply
be replicated towards all member ports like we do for multicast, or VLAN.
Instead we need new driver API. Hardware usually considers a LAG to be a
"logical port", and sets the entire LAG as the forwarding destination.
The physical egress port selection within the LAG is made by hashing
policy, as usual.
To represent the logical port corresponding to the LAG, we pass by value
a copy of the dsa_lag structure to all switches in the tree that have at
least one port in that LAG.
To illustrate why a refcounted list of FDB entries is needed in struct
dsa_lag, it is enough to say that:
- a LAG may be a bridge port and may therefore receive FDB events even
while it isn't yet offloaded by any DSA interface
- DSA interfaces may be removed from a LAG while that is a bridge port;
we don't want FDB entries lingering around, but we don't want to
remove entries that are still in use, either
For all the cases below to work, the idea is to always keep an FDB entry
on a LAG with a reference count equal to the DSA member ports. So:
- if a port joins a LAG, it requests the bridge to replay the FDB, and
the FDB entries get created, or their refcount gets bumped by one
- if a port leaves a LAG, the FDB replay deletes or decrements refcount
by one
- if an FDB is installed towards a LAG with ports already present, that
entry is created (if it doesn't exist) and its refcount is bumped by
the amount of ports already present in the LAG
echo "Adding FDB entry to bond with existing ports"
ip link del bond0
ip link add bond0 type bond mode 802.3ad
ip link set swp1 down && ip link set swp1 master bond0 && ip link set swp1 up
ip link set swp2 down && ip link set swp2 master bond0 && ip link set swp2 up
ip link del br0
ip link add br0 type bridge
ip link set bond0 master br0
bridge fdb add dev bond0 00:01:02:03:04:05 master static
ip link del br0
ip link del bond0
echo "Adding FDB entry to empty bond"
ip link del bond0
ip link add bond0 type bond mode 802.3ad
ip link del br0
ip link add br0 type bridge
ip link set bond0 master br0
bridge fdb add dev bond0 00:01:02:03:04:05 master static
ip link set swp1 down && ip link set swp1 master bond0 && ip link set swp1 up
ip link set swp2 down && ip link set swp2 master bond0 && ip link set swp2 up
ip link del br0
ip link del bond0
echo "Adding FDB entry to empty bond, then removing ports one by one"
ip link del bond0
ip link add bond0 type bond mode 802.3ad
ip link del br0
ip link add br0 type bridge
ip link set bond0 master br0
bridge fdb add dev bond0 00:01:02:03:04:05 master static
ip link set swp1 down && ip link set swp1 master bond0 && ip link set swp1 up
ip link set swp2 down && ip link set swp2 master bond0 && ip link set swp2 up
ip link set swp1 nomaster
ip link set swp2 nomaster
ip link del br0
ip link del bond0
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: Jakub Kicinski <kuba@kernel.org>
2022-02-23 14:00:53 +00:00
|
|
|
|
|
|
|
return 0;
|
|
|
|
}
|
|
|
|
|
2021-01-13 08:42:53 +00:00
|
|
|
static int dsa_switch_lag_change(struct dsa_switch *ds,
|
|
|
|
struct dsa_notifier_lag_info *info)
|
|
|
|
{
|
net: dsa: make cross-chip notifiers more efficient for host events
To determine whether a given port should react to the port targeted by
the notifier, dsa_port_host_vlan_match() and dsa_port_host_address_match()
look at the positioning of the switch port currently executing the
notifier relative to the switch port for which the notifier was emitted.
To maintain stylistic compatibility with the other match functions from
switch.c, the host address and host VLAN match functions take the
notifier information about targeted port, switch and tree indices as
argument. However, these functions only use that information to retrieve
the struct dsa_port *targeted_dp, which is an invariant for the outer
loop that calls them. So it makes more sense to calculate the targeted
dp only once, and pass it to them as argument.
But furthermore, the targeted dp is actually known at the time the call
to dsa_port_notify() is made. It is just that we decide to only save the
indices of the port, switch and tree in the notifier structure, just to
retrace our steps and find the dp again using dsa_switch_find() and
dsa_to_port().
But both the above functions are relatively expensive, since they need
to iterate through lists. It appears more straightforward to make all
notifiers just pass the targeted dp inside their info structure, and
have the code that needs the indices to look at info->dp->index instead
of info->port, or info->dp->ds->index instead of info->sw_index, or
info->dp->ds->dst->index instead of info->tree_index.
For the sake of consistency, all cross-chip notifiers are converted to
pass the "dp" directly.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-04-15 15:46:22 +00:00
|
|
|
if (info->dp->ds == ds && ds->ops->port_lag_change)
|
|
|
|
return ds->ops->port_lag_change(ds, info->dp->index);
|
2021-01-13 08:42:53 +00:00
|
|
|
|
net: dsa: make cross-chip notifiers more efficient for host events
To determine whether a given port should react to the port targeted by
the notifier, dsa_port_host_vlan_match() and dsa_port_host_address_match()
look at the positioning of the switch port currently executing the
notifier relative to the switch port for which the notifier was emitted.
To maintain stylistic compatibility with the other match functions from
switch.c, the host address and host VLAN match functions take the
notifier information about targeted port, switch and tree indices as
argument. However, these functions only use that information to retrieve
the struct dsa_port *targeted_dp, which is an invariant for the outer
loop that calls them. So it makes more sense to calculate the targeted
dp only once, and pass it to them as argument.
But furthermore, the targeted dp is actually known at the time the call
to dsa_port_notify() is made. It is just that we decide to only save the
indices of the port, switch and tree in the notifier structure, just to
retrace our steps and find the dp again using dsa_switch_find() and
dsa_to_port().
But both the above functions are relatively expensive, since they need
to iterate through lists. It appears more straightforward to make all
notifiers just pass the targeted dp inside their info structure, and
have the code that needs the indices to look at info->dp->index instead
of info->port, or info->dp->ds->index instead of info->sw_index, or
info->dp->ds->dst->index instead of info->tree_index.
For the sake of consistency, all cross-chip notifiers are converted to
pass the "dp" directly.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-04-15 15:46:22 +00:00
|
|
|
if (info->dp->ds != ds && ds->ops->crosschip_lag_change)
|
|
|
|
return ds->ops->crosschip_lag_change(ds, info->dp->ds->index,
|
|
|
|
info->dp->index);
|
2021-01-13 08:42:53 +00:00
|
|
|
|
|
|
|
return 0;
|
|
|
|
}
|
|
|
|
|
|
|
|
static int dsa_switch_lag_join(struct dsa_switch *ds,
|
|
|
|
struct dsa_notifier_lag_info *info)
|
|
|
|
{
|
net: dsa: make cross-chip notifiers more efficient for host events
To determine whether a given port should react to the port targeted by
the notifier, dsa_port_host_vlan_match() and dsa_port_host_address_match()
look at the positioning of the switch port currently executing the
notifier relative to the switch port for which the notifier was emitted.
To maintain stylistic compatibility with the other match functions from
switch.c, the host address and host VLAN match functions take the
notifier information about targeted port, switch and tree indices as
argument. However, these functions only use that information to retrieve
the struct dsa_port *targeted_dp, which is an invariant for the outer
loop that calls them. So it makes more sense to calculate the targeted
dp only once, and pass it to them as argument.
But furthermore, the targeted dp is actually known at the time the call
to dsa_port_notify() is made. It is just that we decide to only save the
indices of the port, switch and tree in the notifier structure, just to
retrace our steps and find the dp again using dsa_switch_find() and
dsa_to_port().
But both the above functions are relatively expensive, since they need
to iterate through lists. It appears more straightforward to make all
notifiers just pass the targeted dp inside their info structure, and
have the code that needs the indices to look at info->dp->index instead
of info->port, or info->dp->ds->index instead of info->sw_index, or
info->dp->ds->dst->index instead of info->tree_index.
For the sake of consistency, all cross-chip notifiers are converted to
pass the "dp" directly.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-04-15 15:46:22 +00:00
|
|
|
if (info->dp->ds == ds && ds->ops->port_lag_join)
|
|
|
|
return ds->ops->port_lag_join(ds, info->dp->index, info->lag,
|
2021-01-13 08:42:53 +00:00
|
|
|
info->info);
|
|
|
|
|
net: dsa: make cross-chip notifiers more efficient for host events
To determine whether a given port should react to the port targeted by
the notifier, dsa_port_host_vlan_match() and dsa_port_host_address_match()
look at the positioning of the switch port currently executing the
notifier relative to the switch port for which the notifier was emitted.
To maintain stylistic compatibility with the other match functions from
switch.c, the host address and host VLAN match functions take the
notifier information about targeted port, switch and tree indices as
argument. However, these functions only use that information to retrieve
the struct dsa_port *targeted_dp, which is an invariant for the outer
loop that calls them. So it makes more sense to calculate the targeted
dp only once, and pass it to them as argument.
But furthermore, the targeted dp is actually known at the time the call
to dsa_port_notify() is made. It is just that we decide to only save the
indices of the port, switch and tree in the notifier structure, just to
retrace our steps and find the dp again using dsa_switch_find() and
dsa_to_port().
But both the above functions are relatively expensive, since they need
to iterate through lists. It appears more straightforward to make all
notifiers just pass the targeted dp inside their info structure, and
have the code that needs the indices to look at info->dp->index instead
of info->port, or info->dp->ds->index instead of info->sw_index, or
info->dp->ds->dst->index instead of info->tree_index.
For the sake of consistency, all cross-chip notifiers are converted to
pass the "dp" directly.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-04-15 15:46:22 +00:00
|
|
|
if (info->dp->ds != ds && ds->ops->crosschip_lag_join)
|
|
|
|
return ds->ops->crosschip_lag_join(ds, info->dp->ds->index,
|
|
|
|
info->dp->index, info->lag,
|
2021-01-13 08:42:53 +00:00
|
|
|
info->info);
|
|
|
|
|
2021-06-29 20:32:15 +00:00
|
|
|
return -EOPNOTSUPP;
|
2021-01-13 08:42:53 +00:00
|
|
|
}
|
|
|
|
|
|
|
|
static int dsa_switch_lag_leave(struct dsa_switch *ds,
|
|
|
|
struct dsa_notifier_lag_info *info)
|
|
|
|
{
|
net: dsa: make cross-chip notifiers more efficient for host events
To determine whether a given port should react to the port targeted by
the notifier, dsa_port_host_vlan_match() and dsa_port_host_address_match()
look at the positioning of the switch port currently executing the
notifier relative to the switch port for which the notifier was emitted.
To maintain stylistic compatibility with the other match functions from
switch.c, the host address and host VLAN match functions take the
notifier information about targeted port, switch and tree indices as
argument. However, these functions only use that information to retrieve
the struct dsa_port *targeted_dp, which is an invariant for the outer
loop that calls them. So it makes more sense to calculate the targeted
dp only once, and pass it to them as argument.
But furthermore, the targeted dp is actually known at the time the call
to dsa_port_notify() is made. It is just that we decide to only save the
indices of the port, switch and tree in the notifier structure, just to
retrace our steps and find the dp again using dsa_switch_find() and
dsa_to_port().
But both the above functions are relatively expensive, since they need
to iterate through lists. It appears more straightforward to make all
notifiers just pass the targeted dp inside their info structure, and
have the code that needs the indices to look at info->dp->index instead
of info->port, or info->dp->ds->index instead of info->sw_index, or
info->dp->ds->dst->index instead of info->tree_index.
For the sake of consistency, all cross-chip notifiers are converted to
pass the "dp" directly.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-04-15 15:46:22 +00:00
|
|
|
if (info->dp->ds == ds && ds->ops->port_lag_leave)
|
|
|
|
return ds->ops->port_lag_leave(ds, info->dp->index, info->lag);
|
2021-01-13 08:42:53 +00:00
|
|
|
|
net: dsa: make cross-chip notifiers more efficient for host events
To determine whether a given port should react to the port targeted by
the notifier, dsa_port_host_vlan_match() and dsa_port_host_address_match()
look at the positioning of the switch port currently executing the
notifier relative to the switch port for which the notifier was emitted.
To maintain stylistic compatibility with the other match functions from
switch.c, the host address and host VLAN match functions take the
notifier information about targeted port, switch and tree indices as
argument. However, these functions only use that information to retrieve
the struct dsa_port *targeted_dp, which is an invariant for the outer
loop that calls them. So it makes more sense to calculate the targeted
dp only once, and pass it to them as argument.
But furthermore, the targeted dp is actually known at the time the call
to dsa_port_notify() is made. It is just that we decide to only save the
indices of the port, switch and tree in the notifier structure, just to
retrace our steps and find the dp again using dsa_switch_find() and
dsa_to_port().
But both the above functions are relatively expensive, since they need
to iterate through lists. It appears more straightforward to make all
notifiers just pass the targeted dp inside their info structure, and
have the code that needs the indices to look at info->dp->index instead
of info->port, or info->dp->ds->index instead of info->sw_index, or
info->dp->ds->dst->index instead of info->tree_index.
For the sake of consistency, all cross-chip notifiers are converted to
pass the "dp" directly.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-04-15 15:46:22 +00:00
|
|
|
if (info->dp->ds != ds && ds->ops->crosschip_lag_leave)
|
|
|
|
return ds->ops->crosschip_lag_leave(ds, info->dp->ds->index,
|
|
|
|
info->dp->index, info->lag);
|
2021-01-13 08:42:53 +00:00
|
|
|
|
2021-06-29 20:32:15 +00:00
|
|
|
return -EOPNOTSUPP;
|
2021-01-13 08:42:53 +00:00
|
|
|
}
|
|
|
|
|
net: switchdev: remove the transaction structure from port object notifiers
Since the introduction of the switchdev API, port objects were
transmitted to drivers for offloading using a two-step transactional
model, with a prepare phase that was supposed to catch all errors, and a
commit phase that was supposed to never fail.
Some classes of failures can never be avoided, like hardware access, or
memory allocation. In the latter case, merely attempting to move the
memory allocation to the preparation phase makes it impossible to avoid
memory leaks, since commit 91cf8eceffc1 ("switchdev: Remove unused
transaction item queue") which has removed the unused mechanism of
passing on the allocated memory between one phase and another.
It is time we admit that separating the preparation from the commit
phase is something that is best left for the driver to decide, and not
something that should be baked into the API, especially since there are
no switchdev callers that depend on this.
This patch removes the struct switchdev_trans member from switchdev port
object notifier structures, and converts drivers to not look at this
member.
Where driver conversion is trivial (like in the case of the Marvell
Prestera driver, NXP DPAA2 switch, TI CPSW, and Rocker drivers), it is
done in this patch.
Where driver conversion needs more attention (DSA, Mellanox Spectrum),
the conversion is left for subsequent patches and here we only fake the
prepare/commit phases at a lower level, just not in the switchdev
notifier itself.
Where the code has a natural structure that is best left alone as a
preparation and a commit phase (as in the case of the Ocelot switch),
that structure is left in place, just made to not depend upon the
switchdev transactional model.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Acked-by: Linus Walleij <linus.walleij@linaro.org>
Acked-by: Jiri Pirko <jiri@nvidia.com>
Reviewed-by: Ido Schimmel <idosch@nvidia.com>
Signed-off-by: Jakub Kicinski <kuba@kernel.org>
2021-01-09 00:01:48 +00:00
|
|
|
static int dsa_switch_mdb_add(struct dsa_switch *ds,
|
|
|
|
struct dsa_notifier_mdb_info *info)
|
2017-11-30 16:24:00 +00:00
|
|
|
{
|
net: dsa: make cross-chip notifiers more efficient for host events
To determine whether a given port should react to the port targeted by
the notifier, dsa_port_host_vlan_match() and dsa_port_host_address_match()
look at the positioning of the switch port currently executing the
notifier relative to the switch port for which the notifier was emitted.
To maintain stylistic compatibility with the other match functions from
switch.c, the host address and host VLAN match functions take the
notifier information about targeted port, switch and tree indices as
argument. However, these functions only use that information to retrieve
the struct dsa_port *targeted_dp, which is an invariant for the outer
loop that calls them. So it makes more sense to calculate the targeted
dp only once, and pass it to them as argument.
But furthermore, the targeted dp is actually known at the time the call
to dsa_port_notify() is made. It is just that we decide to only save the
indices of the port, switch and tree in the notifier structure, just to
retrace our steps and find the dp again using dsa_switch_find() and
dsa_to_port().
But both the above functions are relatively expensive, since they need
to iterate through lists. It appears more straightforward to make all
notifiers just pass the targeted dp inside their info structure, and
have the code that needs the indices to look at info->dp->index instead
of info->port, or info->dp->ds->index instead of info->sw_index, or
info->dp->ds->dst->index instead of info->tree_index.
For the sake of consistency, all cross-chip notifiers are converted to
pass the "dp" directly.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-04-15 15:46:22 +00:00
|
|
|
int port = dsa_towards_port(ds, info->dp->ds->index, info->dp->index);
|
2021-10-20 17:49:53 +00:00
|
|
|
struct dsa_port *dp = dsa_to_port(ds, port);
|
2017-11-30 16:24:00 +00:00
|
|
|
|
2021-01-09 00:01:52 +00:00
|
|
|
if (!ds->ops->port_mdb_add)
|
2017-11-30 16:24:00 +00:00
|
|
|
return -EOPNOTSUPP;
|
|
|
|
|
net: dsa: request drivers to perform FDB isolation
For DSA, to encourage drivers to perform FDB isolation simply means to
track which bridge does each FDB and MDB entry belong to. It then
becomes the driver responsibility to use something that makes the FDB
entry from one bridge not match the FDB lookup of ports from other
bridges.
The top-level functions where the bridge is determined are:
- dsa_port_fdb_{add,del}
- dsa_port_host_fdb_{add,del}
- dsa_port_mdb_{add,del}
- dsa_port_host_mdb_{add,del}
aka the pre-crosschip-notifier functions.
Changing the API to pass a reference to a bridge is not superfluous, and
looking at the passed bridge argument is not the same as having the
driver look at dsa_to_port(ds, port)->bridge from the ->port_fdb_add()
method.
DSA installs FDB and MDB entries on shared (CPU and DSA) ports as well,
and those do not have any dp->bridge information to retrieve, because
they are not in any bridge - they are merely the pipes that serve the
user ports that are in one or multiple bridges.
The struct dsa_bridge associated with each FDB/MDB entry is encapsulated
in a larger "struct dsa_db" database. Although only databases associated
to bridges are notified for now, this API will be the starting point for
implementing IFF_UNICAST_FLT in DSA. There, the idea is to install FDB
entries on the CPU port which belong to the corresponding user port's
port database. These are supposed to match only when the port is
standalone.
It is better to introduce the API in its expected final form than to
introduce it for bridges first, then to have to change drivers which may
have made one or more assumptions.
Drivers can use the provided bridge.num, but they can also use a
different numbering scheme that is more convenient.
DSA must perform refcounting on the CPU and DSA ports by also taking
into account the bridge number. So if two bridges request the same local
address, DSA must notify the driver twice, once for each bridge.
In fact, if the driver supports FDB isolation, DSA must perform
refcounting per bridge, but if the driver doesn't, DSA must refcount
host addresses across all bridges, otherwise it would be telling the
driver to delete an FDB entry for a bridge and the driver would delete
it for all bridges. So introduce a bool fdb_isolation in drivers which
would make all bridge databases passed to the cross-chip notifier have
the same number (0). This makes dsa_mac_addr_find() -> dsa_db_equal()
say that all bridge databases are the same database - which is
essentially the legacy behavior.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-02-25 09:22:22 +00:00
|
|
|
return dsa_port_do_mdb_add(dp, info->mdb, info->db);
|
2017-05-19 21:00:54 +00:00
|
|
|
}
|
|
|
|
|
|
|
|
static int dsa_switch_mdb_del(struct dsa_switch *ds,
|
|
|
|
struct dsa_notifier_mdb_info *info)
|
|
|
|
{
|
net: dsa: make cross-chip notifiers more efficient for host events
To determine whether a given port should react to the port targeted by
the notifier, dsa_port_host_vlan_match() and dsa_port_host_address_match()
look at the positioning of the switch port currently executing the
notifier relative to the switch port for which the notifier was emitted.
To maintain stylistic compatibility with the other match functions from
switch.c, the host address and host VLAN match functions take the
notifier information about targeted port, switch and tree indices as
argument. However, these functions only use that information to retrieve
the struct dsa_port *targeted_dp, which is an invariant for the outer
loop that calls them. So it makes more sense to calculate the targeted
dp only once, and pass it to them as argument.
But furthermore, the targeted dp is actually known at the time the call
to dsa_port_notify() is made. It is just that we decide to only save the
indices of the port, switch and tree in the notifier structure, just to
retrace our steps and find the dp again using dsa_switch_find() and
dsa_to_port().
But both the above functions are relatively expensive, since they need
to iterate through lists. It appears more straightforward to make all
notifiers just pass the targeted dp inside their info structure, and
have the code that needs the indices to look at info->dp->index instead
of info->port, or info->dp->ds->index instead of info->sw_index, or
info->dp->ds->dst->index instead of info->tree_index.
For the sake of consistency, all cross-chip notifiers are converted to
pass the "dp" directly.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-04-15 15:46:22 +00:00
|
|
|
int port = dsa_towards_port(ds, info->dp->ds->index, info->dp->index);
|
2021-10-20 17:49:53 +00:00
|
|
|
struct dsa_port *dp = dsa_to_port(ds, port);
|
net: dsa: reference count the MDB entries at the cross-chip notifier level
Ever since the cross-chip notifiers were introduced, the design was
meant to be simplistic and just get the job done without worrying too
much about dangling resources left behind.
For example, somebody installs an MDB entry on sw0p0 in this daisy chain
topology. It gets installed using ds->ops->port_mdb_add() on sw0p0,
sw1p4 and sw2p4.
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ x ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
Then the same person deletes that MDB entry. The cross-chip notifier for
deletion only matches sw0p0:
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ x ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ ]
Why?
Because the DSA links are 'trunk' ports, if we just go ahead and delete
the MDB from sw1p4 and sw2p4 directly, we might delete those multicast
entries when they are still needed. Just consider the fact that somebody
does:
- add a multicast MAC address towards sw0p0 [ via the cross-chip
notifiers it gets installed on the DSA links too ]
- add the same multicast MAC address towards sw0p1 (another port of that
same switch)
- delete the same multicast MAC address from sw0p0.
At this point, if we deleted the MAC address from the DSA links, it
would be flooded, even though there is still an entry on switch 0 which
needs it not to.
So that is why deletions only match the targeted source port and nothing
on DSA links. Of course, dangling resources means that the hardware
tables will eventually run out given enough additions/removals, but hey,
at least it's simple.
But there is a bigger concern which needs to be addressed, and that is
our support for SWITCHDEV_OBJ_ID_HOST_MDB. DSA simply translates such an
object into a dsa_port_host_mdb_add() which ends up as ds->ops->port_mdb_add()
on the upstream port, and a similar thing happens on deletion:
dsa_port_host_mdb_del() will trigger ds->ops->port_mdb_del() on the
upstream port.
When there are 2 VLAN-unaware bridges spanning the same switch (which is
a use case DSA proudly supports), each bridge will install its own
SWITCHDEV_OBJ_ID_HOST_MDB entries. But upon deletion, DSA goes ahead and
emits a DSA_NOTIFIER_MDB_DEL for dp->cpu_dp, which is shared between the
user ports enslaved to br0 and the user ports enslaved to br1. Not good.
The host-trapped multicast addresses installed by br1 will be deleted
when any state changes in br0 (IGMP timers expire, or ports leave, etc).
To avoid this, we could of course go the route of the zero-sum game and
delete the DSA_NOTIFIER_MDB_DEL call for dp->cpu_dp. But the better
design is to just admit that on shared ports like DSA links and CPU
ports, we should be reference counting calls, even if this consumes some
dynamic memory which DSA has traditionally avoided. On the flip side,
the hardware tables of switches are limited in size, so it would be good
if the OS managed them properly instead of having them eventually
overflow.
To address the memory usage concern, we only apply the refcounting of
MDB entries on ports that are really shared (CPU ports and DSA links)
and not on user ports. In a typical single-switch setup, this means only
the CPU port (and the host MDB entries are not that many, really).
The name of the newly introduced data structures (dsa_mac_addr) is
chosen in such a way that will be reusable for host FDB entries (next
patch).
With this change, we can finally have the same matching logic for the
MDB additions and deletions, as well as for their host-trapped variants.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-06-29 14:06:50 +00:00
|
|
|
|
2017-05-19 21:00:54 +00:00
|
|
|
if (!ds->ops->port_mdb_del)
|
|
|
|
return -EOPNOTSUPP;
|
|
|
|
|
net: dsa: request drivers to perform FDB isolation
For DSA, to encourage drivers to perform FDB isolation simply means to
track which bridge does each FDB and MDB entry belong to. It then
becomes the driver responsibility to use something that makes the FDB
entry from one bridge not match the FDB lookup of ports from other
bridges.
The top-level functions where the bridge is determined are:
- dsa_port_fdb_{add,del}
- dsa_port_host_fdb_{add,del}
- dsa_port_mdb_{add,del}
- dsa_port_host_mdb_{add,del}
aka the pre-crosschip-notifier functions.
Changing the API to pass a reference to a bridge is not superfluous, and
looking at the passed bridge argument is not the same as having the
driver look at dsa_to_port(ds, port)->bridge from the ->port_fdb_add()
method.
DSA installs FDB and MDB entries on shared (CPU and DSA) ports as well,
and those do not have any dp->bridge information to retrieve, because
they are not in any bridge - they are merely the pipes that serve the
user ports that are in one or multiple bridges.
The struct dsa_bridge associated with each FDB/MDB entry is encapsulated
in a larger "struct dsa_db" database. Although only databases associated
to bridges are notified for now, this API will be the starting point for
implementing IFF_UNICAST_FLT in DSA. There, the idea is to install FDB
entries on the CPU port which belong to the corresponding user port's
port database. These are supposed to match only when the port is
standalone.
It is better to introduce the API in its expected final form than to
introduce it for bridges first, then to have to change drivers which may
have made one or more assumptions.
Drivers can use the provided bridge.num, but they can also use a
different numbering scheme that is more convenient.
DSA must perform refcounting on the CPU and DSA ports by also taking
into account the bridge number. So if two bridges request the same local
address, DSA must notify the driver twice, once for each bridge.
In fact, if the driver supports FDB isolation, DSA must perform
refcounting per bridge, but if the driver doesn't, DSA must refcount
host addresses across all bridges, otherwise it would be telling the
driver to delete an FDB entry for a bridge and the driver would delete
it for all bridges. So introduce a bool fdb_isolation in drivers which
would make all bridge databases passed to the cross-chip notifier have
the same number (0). This makes dsa_mac_addr_find() -> dsa_db_equal()
say that all bridge databases are the same database - which is
essentially the legacy behavior.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-02-25 09:22:22 +00:00
|
|
|
return dsa_port_do_mdb_del(dp, info->mdb, info->db);
|
2017-05-19 21:00:54 +00:00
|
|
|
}
|
|
|
|
|
net: dsa: introduce a separate cross-chip notifier type for host MDBs
Commit abd49535c380 ("net: dsa: execute dsa_switch_mdb_add only for
routing port in cross-chip topologies") does a surprisingly good job
even for the SWITCHDEV_OBJ_ID_HOST_MDB use case, where DSA simply
translates a switchdev object received on dp into a cross-chip notifier
for dp->cpu_dp.
To visualize how that works, imagine the daisy chain topology below and
consider a SWITCHDEV_OBJ_ID_HOST_MDB object emitted on sw2p0. How does
the cross-chip notifier know to match on all the right ports (sw0p4, the
dedicated CPU port, sw1p4, an upstream DSA link, and sw2p4, another
upstream DSA link)?
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ ] [ ] [ ] [ ] [ x ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
The answer is simple: the dedicated CPU port of sw2p0 is sw0p4, and
dsa_routing_port returns the upstream port for all switches.
That is fine, but there are other topologies where this does not work as
well. There are trees with "H" topologies in the wild, where there are 2
or more switches with DSA links between them, but every switch has its
dedicated CPU port. For these topologies, it seems stupid for the neighbor
switches to install an MDB entry on the routing port, since these
multicast addresses are fundamentally different than the usual ones we
support (and that is the justification for this patch, to introduce the
concept of a termination plane multicast MAC address, as opposed to a
forwarding plane multicast MAC address).
For example, when a SWITCHDEV_OBJ_ID_HOST_MDB would get added to sw0p0,
without this patch, it would get treated as a regular port MDB on sw0p2
and it would match on the ports below (including the sw1p3 routing port).
| |
sw0p0 sw0p1 sw0p2 sw0p3 sw1p3 sw1p2 sw1p1 sw1p0
[ user ] [ user ] [ cpu ] [ dsa ] [ dsa ] [ cpu ] [ user ] [ user ]
[ ] [ ] [ x ] [ ] ---- [ x ] [ ] [ ] [ ]
With the patch, the host MDB notifier on sw0p0 matches only on the local
switch, which is what we want for a termination plane address.
| |
sw0p0 sw0p1 sw0p2 sw0p3 sw1p3 sw1p2 sw1p1 sw1p0
[ user ] [ user ] [ cpu ] [ dsa ] [ dsa ] [ cpu ] [ user ] [ user ]
[ ] [ ] [ x ] [ ] ---- [ ] [ ] [ ] [ ]
Name this new matching function "dsa_switch_host_address_match" since we
will be reusing it soon for host FDB entries as well.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-06-29 14:06:49 +00:00
|
|
|
static int dsa_switch_host_mdb_add(struct dsa_switch *ds,
|
|
|
|
struct dsa_notifier_mdb_info *info)
|
|
|
|
{
|
2021-10-20 17:49:53 +00:00
|
|
|
struct dsa_port *dp;
|
net: dsa: introduce a separate cross-chip notifier type for host MDBs
Commit abd49535c380 ("net: dsa: execute dsa_switch_mdb_add only for
routing port in cross-chip topologies") does a surprisingly good job
even for the SWITCHDEV_OBJ_ID_HOST_MDB use case, where DSA simply
translates a switchdev object received on dp into a cross-chip notifier
for dp->cpu_dp.
To visualize how that works, imagine the daisy chain topology below and
consider a SWITCHDEV_OBJ_ID_HOST_MDB object emitted on sw2p0. How does
the cross-chip notifier know to match on all the right ports (sw0p4, the
dedicated CPU port, sw1p4, an upstream DSA link, and sw2p4, another
upstream DSA link)?
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ ] [ ] [ ] [ ] [ x ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
The answer is simple: the dedicated CPU port of sw2p0 is sw0p4, and
dsa_routing_port returns the upstream port for all switches.
That is fine, but there are other topologies where this does not work as
well. There are trees with "H" topologies in the wild, where there are 2
or more switches with DSA links between them, but every switch has its
dedicated CPU port. For these topologies, it seems stupid for the neighbor
switches to install an MDB entry on the routing port, since these
multicast addresses are fundamentally different than the usual ones we
support (and that is the justification for this patch, to introduce the
concept of a termination plane multicast MAC address, as opposed to a
forwarding plane multicast MAC address).
For example, when a SWITCHDEV_OBJ_ID_HOST_MDB would get added to sw0p0,
without this patch, it would get treated as a regular port MDB on sw0p2
and it would match on the ports below (including the sw1p3 routing port).
| |
sw0p0 sw0p1 sw0p2 sw0p3 sw1p3 sw1p2 sw1p1 sw1p0
[ user ] [ user ] [ cpu ] [ dsa ] [ dsa ] [ cpu ] [ user ] [ user ]
[ ] [ ] [ x ] [ ] ---- [ x ] [ ] [ ] [ ]
With the patch, the host MDB notifier on sw0p0 matches only on the local
switch, which is what we want for a termination plane address.
| |
sw0p0 sw0p1 sw0p2 sw0p3 sw1p3 sw1p2 sw1p1 sw1p0
[ user ] [ user ] [ cpu ] [ dsa ] [ dsa ] [ cpu ] [ user ] [ user ]
[ ] [ ] [ x ] [ ] ---- [ ] [ ] [ ] [ ]
Name this new matching function "dsa_switch_host_address_match" since we
will be reusing it soon for host FDB entries as well.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-06-29 14:06:49 +00:00
|
|
|
int err = 0;
|
|
|
|
|
|
|
|
if (!ds->ops->port_mdb_add)
|
|
|
|
return -EOPNOTSUPP;
|
|
|
|
|
2021-10-20 17:49:53 +00:00
|
|
|
dsa_switch_for_each_port(dp, ds) {
|
net: dsa: make cross-chip notifiers more efficient for host events
To determine whether a given port should react to the port targeted by
the notifier, dsa_port_host_vlan_match() and dsa_port_host_address_match()
look at the positioning of the switch port currently executing the
notifier relative to the switch port for which the notifier was emitted.
To maintain stylistic compatibility with the other match functions from
switch.c, the host address and host VLAN match functions take the
notifier information about targeted port, switch and tree indices as
argument. However, these functions only use that information to retrieve
the struct dsa_port *targeted_dp, which is an invariant for the outer
loop that calls them. So it makes more sense to calculate the targeted
dp only once, and pass it to them as argument.
But furthermore, the targeted dp is actually known at the time the call
to dsa_port_notify() is made. It is just that we decide to only save the
indices of the port, switch and tree in the notifier structure, just to
retrace our steps and find the dp again using dsa_switch_find() and
dsa_to_port().
But both the above functions are relatively expensive, since they need
to iterate through lists. It appears more straightforward to make all
notifiers just pass the targeted dp inside their info structure, and
have the code that needs the indices to look at info->dp->index instead
of info->port, or info->dp->ds->index instead of info->sw_index, or
info->dp->ds->dst->index instead of info->tree_index.
For the sake of consistency, all cross-chip notifiers are converted to
pass the "dp" directly.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-04-15 15:46:22 +00:00
|
|
|
if (dsa_port_host_address_match(dp, info->dp)) {
|
net: dsa: request drivers to perform FDB isolation
For DSA, to encourage drivers to perform FDB isolation simply means to
track which bridge does each FDB and MDB entry belong to. It then
becomes the driver responsibility to use something that makes the FDB
entry from one bridge not match the FDB lookup of ports from other
bridges.
The top-level functions where the bridge is determined are:
- dsa_port_fdb_{add,del}
- dsa_port_host_fdb_{add,del}
- dsa_port_mdb_{add,del}
- dsa_port_host_mdb_{add,del}
aka the pre-crosschip-notifier functions.
Changing the API to pass a reference to a bridge is not superfluous, and
looking at the passed bridge argument is not the same as having the
driver look at dsa_to_port(ds, port)->bridge from the ->port_fdb_add()
method.
DSA installs FDB and MDB entries on shared (CPU and DSA) ports as well,
and those do not have any dp->bridge information to retrieve, because
they are not in any bridge - they are merely the pipes that serve the
user ports that are in one or multiple bridges.
The struct dsa_bridge associated with each FDB/MDB entry is encapsulated
in a larger "struct dsa_db" database. Although only databases associated
to bridges are notified for now, this API will be the starting point for
implementing IFF_UNICAST_FLT in DSA. There, the idea is to install FDB
entries on the CPU port which belong to the corresponding user port's
port database. These are supposed to match only when the port is
standalone.
It is better to introduce the API in its expected final form than to
introduce it for bridges first, then to have to change drivers which may
have made one or more assumptions.
Drivers can use the provided bridge.num, but they can also use a
different numbering scheme that is more convenient.
DSA must perform refcounting on the CPU and DSA ports by also taking
into account the bridge number. So if two bridges request the same local
address, DSA must notify the driver twice, once for each bridge.
In fact, if the driver supports FDB isolation, DSA must perform
refcounting per bridge, but if the driver doesn't, DSA must refcount
host addresses across all bridges, otherwise it would be telling the
driver to delete an FDB entry for a bridge and the driver would delete
it for all bridges. So introduce a bool fdb_isolation in drivers which
would make all bridge databases passed to the cross-chip notifier have
the same number (0). This makes dsa_mac_addr_find() -> dsa_db_equal()
say that all bridge databases are the same database - which is
essentially the legacy behavior.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-02-25 09:22:22 +00:00
|
|
|
err = dsa_port_do_mdb_add(dp, info->mdb, info->db);
|
net: dsa: introduce a separate cross-chip notifier type for host MDBs
Commit abd49535c380 ("net: dsa: execute dsa_switch_mdb_add only for
routing port in cross-chip topologies") does a surprisingly good job
even for the SWITCHDEV_OBJ_ID_HOST_MDB use case, where DSA simply
translates a switchdev object received on dp into a cross-chip notifier
for dp->cpu_dp.
To visualize how that works, imagine the daisy chain topology below and
consider a SWITCHDEV_OBJ_ID_HOST_MDB object emitted on sw2p0. How does
the cross-chip notifier know to match on all the right ports (sw0p4, the
dedicated CPU port, sw1p4, an upstream DSA link, and sw2p4, another
upstream DSA link)?
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ ] [ ] [ ] [ ] [ x ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
The answer is simple: the dedicated CPU port of sw2p0 is sw0p4, and
dsa_routing_port returns the upstream port for all switches.
That is fine, but there are other topologies where this does not work as
well. There are trees with "H" topologies in the wild, where there are 2
or more switches with DSA links between them, but every switch has its
dedicated CPU port. For these topologies, it seems stupid for the neighbor
switches to install an MDB entry on the routing port, since these
multicast addresses are fundamentally different than the usual ones we
support (and that is the justification for this patch, to introduce the
concept of a termination plane multicast MAC address, as opposed to a
forwarding plane multicast MAC address).
For example, when a SWITCHDEV_OBJ_ID_HOST_MDB would get added to sw0p0,
without this patch, it would get treated as a regular port MDB on sw0p2
and it would match on the ports below (including the sw1p3 routing port).
| |
sw0p0 sw0p1 sw0p2 sw0p3 sw1p3 sw1p2 sw1p1 sw1p0
[ user ] [ user ] [ cpu ] [ dsa ] [ dsa ] [ cpu ] [ user ] [ user ]
[ ] [ ] [ x ] [ ] ---- [ x ] [ ] [ ] [ ]
With the patch, the host MDB notifier on sw0p0 matches only on the local
switch, which is what we want for a termination plane address.
| |
sw0p0 sw0p1 sw0p2 sw0p3 sw1p3 sw1p2 sw1p1 sw1p0
[ user ] [ user ] [ cpu ] [ dsa ] [ dsa ] [ cpu ] [ user ] [ user ]
[ ] [ ] [ x ] [ ] ---- [ ] [ ] [ ] [ ]
Name this new matching function "dsa_switch_host_address_match" since we
will be reusing it soon for host FDB entries as well.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-06-29 14:06:49 +00:00
|
|
|
if (err)
|
|
|
|
break;
|
|
|
|
}
|
|
|
|
}
|
|
|
|
|
|
|
|
return err;
|
|
|
|
}
|
|
|
|
|
|
|
|
static int dsa_switch_host_mdb_del(struct dsa_switch *ds,
|
|
|
|
struct dsa_notifier_mdb_info *info)
|
|
|
|
{
|
2021-10-20 17:49:53 +00:00
|
|
|
struct dsa_port *dp;
|
net: dsa: reference count the MDB entries at the cross-chip notifier level
Ever since the cross-chip notifiers were introduced, the design was
meant to be simplistic and just get the job done without worrying too
much about dangling resources left behind.
For example, somebody installs an MDB entry on sw0p0 in this daisy chain
topology. It gets installed using ds->ops->port_mdb_add() on sw0p0,
sw1p4 and sw2p4.
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ x ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
Then the same person deletes that MDB entry. The cross-chip notifier for
deletion only matches sw0p0:
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ x ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ ]
Why?
Because the DSA links are 'trunk' ports, if we just go ahead and delete
the MDB from sw1p4 and sw2p4 directly, we might delete those multicast
entries when they are still needed. Just consider the fact that somebody
does:
- add a multicast MAC address towards sw0p0 [ via the cross-chip
notifiers it gets installed on the DSA links too ]
- add the same multicast MAC address towards sw0p1 (another port of that
same switch)
- delete the same multicast MAC address from sw0p0.
At this point, if we deleted the MAC address from the DSA links, it
would be flooded, even though there is still an entry on switch 0 which
needs it not to.
So that is why deletions only match the targeted source port and nothing
on DSA links. Of course, dangling resources means that the hardware
tables will eventually run out given enough additions/removals, but hey,
at least it's simple.
But there is a bigger concern which needs to be addressed, and that is
our support for SWITCHDEV_OBJ_ID_HOST_MDB. DSA simply translates such an
object into a dsa_port_host_mdb_add() which ends up as ds->ops->port_mdb_add()
on the upstream port, and a similar thing happens on deletion:
dsa_port_host_mdb_del() will trigger ds->ops->port_mdb_del() on the
upstream port.
When there are 2 VLAN-unaware bridges spanning the same switch (which is
a use case DSA proudly supports), each bridge will install its own
SWITCHDEV_OBJ_ID_HOST_MDB entries. But upon deletion, DSA goes ahead and
emits a DSA_NOTIFIER_MDB_DEL for dp->cpu_dp, which is shared between the
user ports enslaved to br0 and the user ports enslaved to br1. Not good.
The host-trapped multicast addresses installed by br1 will be deleted
when any state changes in br0 (IGMP timers expire, or ports leave, etc).
To avoid this, we could of course go the route of the zero-sum game and
delete the DSA_NOTIFIER_MDB_DEL call for dp->cpu_dp. But the better
design is to just admit that on shared ports like DSA links and CPU
ports, we should be reference counting calls, even if this consumes some
dynamic memory which DSA has traditionally avoided. On the flip side,
the hardware tables of switches are limited in size, so it would be good
if the OS managed them properly instead of having them eventually
overflow.
To address the memory usage concern, we only apply the refcounting of
MDB entries on ports that are really shared (CPU ports and DSA links)
and not on user ports. In a typical single-switch setup, this means only
the CPU port (and the host MDB entries are not that many, really).
The name of the newly introduced data structures (dsa_mac_addr) is
chosen in such a way that will be reusable for host FDB entries (next
patch).
With this change, we can finally have the same matching logic for the
MDB additions and deletions, as well as for their host-trapped variants.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-06-29 14:06:50 +00:00
|
|
|
int err = 0;
|
|
|
|
|
net: dsa: introduce a separate cross-chip notifier type for host MDBs
Commit abd49535c380 ("net: dsa: execute dsa_switch_mdb_add only for
routing port in cross-chip topologies") does a surprisingly good job
even for the SWITCHDEV_OBJ_ID_HOST_MDB use case, where DSA simply
translates a switchdev object received on dp into a cross-chip notifier
for dp->cpu_dp.
To visualize how that works, imagine the daisy chain topology below and
consider a SWITCHDEV_OBJ_ID_HOST_MDB object emitted on sw2p0. How does
the cross-chip notifier know to match on all the right ports (sw0p4, the
dedicated CPU port, sw1p4, an upstream DSA link, and sw2p4, another
upstream DSA link)?
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ ] [ ] [ ] [ ] [ x ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
The answer is simple: the dedicated CPU port of sw2p0 is sw0p4, and
dsa_routing_port returns the upstream port for all switches.
That is fine, but there are other topologies where this does not work as
well. There are trees with "H" topologies in the wild, where there are 2
or more switches with DSA links between them, but every switch has its
dedicated CPU port. For these topologies, it seems stupid for the neighbor
switches to install an MDB entry on the routing port, since these
multicast addresses are fundamentally different than the usual ones we
support (and that is the justification for this patch, to introduce the
concept of a termination plane multicast MAC address, as opposed to a
forwarding plane multicast MAC address).
For example, when a SWITCHDEV_OBJ_ID_HOST_MDB would get added to sw0p0,
without this patch, it would get treated as a regular port MDB on sw0p2
and it would match on the ports below (including the sw1p3 routing port).
| |
sw0p0 sw0p1 sw0p2 sw0p3 sw1p3 sw1p2 sw1p1 sw1p0
[ user ] [ user ] [ cpu ] [ dsa ] [ dsa ] [ cpu ] [ user ] [ user ]
[ ] [ ] [ x ] [ ] ---- [ x ] [ ] [ ] [ ]
With the patch, the host MDB notifier on sw0p0 matches only on the local
switch, which is what we want for a termination plane address.
| |
sw0p0 sw0p1 sw0p2 sw0p3 sw1p3 sw1p2 sw1p1 sw1p0
[ user ] [ user ] [ cpu ] [ dsa ] [ dsa ] [ cpu ] [ user ] [ user ]
[ ] [ ] [ x ] [ ] ---- [ ] [ ] [ ] [ ]
Name this new matching function "dsa_switch_host_address_match" since we
will be reusing it soon for host FDB entries as well.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-06-29 14:06:49 +00:00
|
|
|
if (!ds->ops->port_mdb_del)
|
|
|
|
return -EOPNOTSUPP;
|
|
|
|
|
2021-10-20 17:49:53 +00:00
|
|
|
dsa_switch_for_each_port(dp, ds) {
|
net: dsa: make cross-chip notifiers more efficient for host events
To determine whether a given port should react to the port targeted by
the notifier, dsa_port_host_vlan_match() and dsa_port_host_address_match()
look at the positioning of the switch port currently executing the
notifier relative to the switch port for which the notifier was emitted.
To maintain stylistic compatibility with the other match functions from
switch.c, the host address and host VLAN match functions take the
notifier information about targeted port, switch and tree indices as
argument. However, these functions only use that information to retrieve
the struct dsa_port *targeted_dp, which is an invariant for the outer
loop that calls them. So it makes more sense to calculate the targeted
dp only once, and pass it to them as argument.
But furthermore, the targeted dp is actually known at the time the call
to dsa_port_notify() is made. It is just that we decide to only save the
indices of the port, switch and tree in the notifier structure, just to
retrace our steps and find the dp again using dsa_switch_find() and
dsa_to_port().
But both the above functions are relatively expensive, since they need
to iterate through lists. It appears more straightforward to make all
notifiers just pass the targeted dp inside their info structure, and
have the code that needs the indices to look at info->dp->index instead
of info->port, or info->dp->ds->index instead of info->sw_index, or
info->dp->ds->dst->index instead of info->tree_index.
For the sake of consistency, all cross-chip notifiers are converted to
pass the "dp" directly.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-04-15 15:46:22 +00:00
|
|
|
if (dsa_port_host_address_match(dp, info->dp)) {
|
net: dsa: request drivers to perform FDB isolation
For DSA, to encourage drivers to perform FDB isolation simply means to
track which bridge does each FDB and MDB entry belong to. It then
becomes the driver responsibility to use something that makes the FDB
entry from one bridge not match the FDB lookup of ports from other
bridges.
The top-level functions where the bridge is determined are:
- dsa_port_fdb_{add,del}
- dsa_port_host_fdb_{add,del}
- dsa_port_mdb_{add,del}
- dsa_port_host_mdb_{add,del}
aka the pre-crosschip-notifier functions.
Changing the API to pass a reference to a bridge is not superfluous, and
looking at the passed bridge argument is not the same as having the
driver look at dsa_to_port(ds, port)->bridge from the ->port_fdb_add()
method.
DSA installs FDB and MDB entries on shared (CPU and DSA) ports as well,
and those do not have any dp->bridge information to retrieve, because
they are not in any bridge - they are merely the pipes that serve the
user ports that are in one or multiple bridges.
The struct dsa_bridge associated with each FDB/MDB entry is encapsulated
in a larger "struct dsa_db" database. Although only databases associated
to bridges are notified for now, this API will be the starting point for
implementing IFF_UNICAST_FLT in DSA. There, the idea is to install FDB
entries on the CPU port which belong to the corresponding user port's
port database. These are supposed to match only when the port is
standalone.
It is better to introduce the API in its expected final form than to
introduce it for bridges first, then to have to change drivers which may
have made one or more assumptions.
Drivers can use the provided bridge.num, but they can also use a
different numbering scheme that is more convenient.
DSA must perform refcounting on the CPU and DSA ports by also taking
into account the bridge number. So if two bridges request the same local
address, DSA must notify the driver twice, once for each bridge.
In fact, if the driver supports FDB isolation, DSA must perform
refcounting per bridge, but if the driver doesn't, DSA must refcount
host addresses across all bridges, otherwise it would be telling the
driver to delete an FDB entry for a bridge and the driver would delete
it for all bridges. So introduce a bool fdb_isolation in drivers which
would make all bridge databases passed to the cross-chip notifier have
the same number (0). This makes dsa_mac_addr_find() -> dsa_db_equal()
say that all bridge databases are the same database - which is
essentially the legacy behavior.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-02-25 09:22:22 +00:00
|
|
|
err = dsa_port_do_mdb_del(dp, info->mdb, info->db);
|
net: dsa: reference count the MDB entries at the cross-chip notifier level
Ever since the cross-chip notifiers were introduced, the design was
meant to be simplistic and just get the job done without worrying too
much about dangling resources left behind.
For example, somebody installs an MDB entry on sw0p0 in this daisy chain
topology. It gets installed using ds->ops->port_mdb_add() on sw0p0,
sw1p4 and sw2p4.
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ x ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
Then the same person deletes that MDB entry. The cross-chip notifier for
deletion only matches sw0p0:
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ x ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ ]
Why?
Because the DSA links are 'trunk' ports, if we just go ahead and delete
the MDB from sw1p4 and sw2p4 directly, we might delete those multicast
entries when they are still needed. Just consider the fact that somebody
does:
- add a multicast MAC address towards sw0p0 [ via the cross-chip
notifiers it gets installed on the DSA links too ]
- add the same multicast MAC address towards sw0p1 (another port of that
same switch)
- delete the same multicast MAC address from sw0p0.
At this point, if we deleted the MAC address from the DSA links, it
would be flooded, even though there is still an entry on switch 0 which
needs it not to.
So that is why deletions only match the targeted source port and nothing
on DSA links. Of course, dangling resources means that the hardware
tables will eventually run out given enough additions/removals, but hey,
at least it's simple.
But there is a bigger concern which needs to be addressed, and that is
our support for SWITCHDEV_OBJ_ID_HOST_MDB. DSA simply translates such an
object into a dsa_port_host_mdb_add() which ends up as ds->ops->port_mdb_add()
on the upstream port, and a similar thing happens on deletion:
dsa_port_host_mdb_del() will trigger ds->ops->port_mdb_del() on the
upstream port.
When there are 2 VLAN-unaware bridges spanning the same switch (which is
a use case DSA proudly supports), each bridge will install its own
SWITCHDEV_OBJ_ID_HOST_MDB entries. But upon deletion, DSA goes ahead and
emits a DSA_NOTIFIER_MDB_DEL for dp->cpu_dp, which is shared between the
user ports enslaved to br0 and the user ports enslaved to br1. Not good.
The host-trapped multicast addresses installed by br1 will be deleted
when any state changes in br0 (IGMP timers expire, or ports leave, etc).
To avoid this, we could of course go the route of the zero-sum game and
delete the DSA_NOTIFIER_MDB_DEL call for dp->cpu_dp. But the better
design is to just admit that on shared ports like DSA links and CPU
ports, we should be reference counting calls, even if this consumes some
dynamic memory which DSA has traditionally avoided. On the flip side,
the hardware tables of switches are limited in size, so it would be good
if the OS managed them properly instead of having them eventually
overflow.
To address the memory usage concern, we only apply the refcounting of
MDB entries on ports that are really shared (CPU ports and DSA links)
and not on user ports. In a typical single-switch setup, this means only
the CPU port (and the host MDB entries are not that many, really).
The name of the newly introduced data structures (dsa_mac_addr) is
chosen in such a way that will be reusable for host FDB entries (next
patch).
With this change, we can finally have the same matching logic for the
MDB additions and deletions, as well as for their host-trapped variants.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-06-29 14:06:50 +00:00
|
|
|
if (err)
|
|
|
|
break;
|
|
|
|
}
|
|
|
|
}
|
net: dsa: introduce a separate cross-chip notifier type for host MDBs
Commit abd49535c380 ("net: dsa: execute dsa_switch_mdb_add only for
routing port in cross-chip topologies") does a surprisingly good job
even for the SWITCHDEV_OBJ_ID_HOST_MDB use case, where DSA simply
translates a switchdev object received on dp into a cross-chip notifier
for dp->cpu_dp.
To visualize how that works, imagine the daisy chain topology below and
consider a SWITCHDEV_OBJ_ID_HOST_MDB object emitted on sw2p0. How does
the cross-chip notifier know to match on all the right ports (sw0p4, the
dedicated CPU port, sw1p4, an upstream DSA link, and sw2p4, another
upstream DSA link)?
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ ] [ ] [ ] [ ] [ x ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
The answer is simple: the dedicated CPU port of sw2p0 is sw0p4, and
dsa_routing_port returns the upstream port for all switches.
That is fine, but there are other topologies where this does not work as
well. There are trees with "H" topologies in the wild, where there are 2
or more switches with DSA links between them, but every switch has its
dedicated CPU port. For these topologies, it seems stupid for the neighbor
switches to install an MDB entry on the routing port, since these
multicast addresses are fundamentally different than the usual ones we
support (and that is the justification for this patch, to introduce the
concept of a termination plane multicast MAC address, as opposed to a
forwarding plane multicast MAC address).
For example, when a SWITCHDEV_OBJ_ID_HOST_MDB would get added to sw0p0,
without this patch, it would get treated as a regular port MDB on sw0p2
and it would match on the ports below (including the sw1p3 routing port).
| |
sw0p0 sw0p1 sw0p2 sw0p3 sw1p3 sw1p2 sw1p1 sw1p0
[ user ] [ user ] [ cpu ] [ dsa ] [ dsa ] [ cpu ] [ user ] [ user ]
[ ] [ ] [ x ] [ ] ---- [ x ] [ ] [ ] [ ]
With the patch, the host MDB notifier on sw0p0 matches only on the local
switch, which is what we want for a termination plane address.
| |
sw0p0 sw0p1 sw0p2 sw0p3 sw1p3 sw1p2 sw1p1 sw1p0
[ user ] [ user ] [ cpu ] [ dsa ] [ dsa ] [ cpu ] [ user ] [ user ]
[ ] [ ] [ x ] [ ] ---- [ ] [ ] [ ] [ ]
Name this new matching function "dsa_switch_host_address_match" since we
will be reusing it soon for host FDB entries as well.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-06-29 14:06:49 +00:00
|
|
|
|
net: dsa: reference count the MDB entries at the cross-chip notifier level
Ever since the cross-chip notifiers were introduced, the design was
meant to be simplistic and just get the job done without worrying too
much about dangling resources left behind.
For example, somebody installs an MDB entry on sw0p0 in this daisy chain
topology. It gets installed using ds->ops->port_mdb_add() on sw0p0,
sw1p4 and sw2p4.
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ x ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
Then the same person deletes that MDB entry. The cross-chip notifier for
deletion only matches sw0p0:
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ x ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ ]
Why?
Because the DSA links are 'trunk' ports, if we just go ahead and delete
the MDB from sw1p4 and sw2p4 directly, we might delete those multicast
entries when they are still needed. Just consider the fact that somebody
does:
- add a multicast MAC address towards sw0p0 [ via the cross-chip
notifiers it gets installed on the DSA links too ]
- add the same multicast MAC address towards sw0p1 (another port of that
same switch)
- delete the same multicast MAC address from sw0p0.
At this point, if we deleted the MAC address from the DSA links, it
would be flooded, even though there is still an entry on switch 0 which
needs it not to.
So that is why deletions only match the targeted source port and nothing
on DSA links. Of course, dangling resources means that the hardware
tables will eventually run out given enough additions/removals, but hey,
at least it's simple.
But there is a bigger concern which needs to be addressed, and that is
our support for SWITCHDEV_OBJ_ID_HOST_MDB. DSA simply translates such an
object into a dsa_port_host_mdb_add() which ends up as ds->ops->port_mdb_add()
on the upstream port, and a similar thing happens on deletion:
dsa_port_host_mdb_del() will trigger ds->ops->port_mdb_del() on the
upstream port.
When there are 2 VLAN-unaware bridges spanning the same switch (which is
a use case DSA proudly supports), each bridge will install its own
SWITCHDEV_OBJ_ID_HOST_MDB entries. But upon deletion, DSA goes ahead and
emits a DSA_NOTIFIER_MDB_DEL for dp->cpu_dp, which is shared between the
user ports enslaved to br0 and the user ports enslaved to br1. Not good.
The host-trapped multicast addresses installed by br1 will be deleted
when any state changes in br0 (IGMP timers expire, or ports leave, etc).
To avoid this, we could of course go the route of the zero-sum game and
delete the DSA_NOTIFIER_MDB_DEL call for dp->cpu_dp. But the better
design is to just admit that on shared ports like DSA links and CPU
ports, we should be reference counting calls, even if this consumes some
dynamic memory which DSA has traditionally avoided. On the flip side,
the hardware tables of switches are limited in size, so it would be good
if the OS managed them properly instead of having them eventually
overflow.
To address the memory usage concern, we only apply the refcounting of
MDB entries on ports that are really shared (CPU ports and DSA links)
and not on user ports. In a typical single-switch setup, this means only
the CPU port (and the host MDB entries are not that many, really).
The name of the newly introduced data structures (dsa_mac_addr) is
chosen in such a way that will be reusable for host FDB entries (next
patch).
With this change, we can finally have the same matching logic for the
MDB additions and deletions, as well as for their host-trapped variants.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-06-29 14:06:50 +00:00
|
|
|
return err;
|
net: dsa: introduce a separate cross-chip notifier type for host MDBs
Commit abd49535c380 ("net: dsa: execute dsa_switch_mdb_add only for
routing port in cross-chip topologies") does a surprisingly good job
even for the SWITCHDEV_OBJ_ID_HOST_MDB use case, where DSA simply
translates a switchdev object received on dp into a cross-chip notifier
for dp->cpu_dp.
To visualize how that works, imagine the daisy chain topology below and
consider a SWITCHDEV_OBJ_ID_HOST_MDB object emitted on sw2p0. How does
the cross-chip notifier know to match on all the right ports (sw0p4, the
dedicated CPU port, sw1p4, an upstream DSA link, and sw2p4, another
upstream DSA link)?
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ ] [ ] [ ] [ ] [ x ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
The answer is simple: the dedicated CPU port of sw2p0 is sw0p4, and
dsa_routing_port returns the upstream port for all switches.
That is fine, but there are other topologies where this does not work as
well. There are trees with "H" topologies in the wild, where there are 2
or more switches with DSA links between them, but every switch has its
dedicated CPU port. For these topologies, it seems stupid for the neighbor
switches to install an MDB entry on the routing port, since these
multicast addresses are fundamentally different than the usual ones we
support (and that is the justification for this patch, to introduce the
concept of a termination plane multicast MAC address, as opposed to a
forwarding plane multicast MAC address).
For example, when a SWITCHDEV_OBJ_ID_HOST_MDB would get added to sw0p0,
without this patch, it would get treated as a regular port MDB on sw0p2
and it would match on the ports below (including the sw1p3 routing port).
| |
sw0p0 sw0p1 sw0p2 sw0p3 sw1p3 sw1p2 sw1p1 sw1p0
[ user ] [ user ] [ cpu ] [ dsa ] [ dsa ] [ cpu ] [ user ] [ user ]
[ ] [ ] [ x ] [ ] ---- [ x ] [ ] [ ] [ ]
With the patch, the host MDB notifier on sw0p0 matches only on the local
switch, which is what we want for a termination plane address.
| |
sw0p0 sw0p1 sw0p2 sw0p3 sw1p3 sw1p2 sw1p1 sw1p0
[ user ] [ user ] [ cpu ] [ dsa ] [ dsa ] [ cpu ] [ user ] [ user ]
[ ] [ ] [ x ] [ ] ---- [ ] [ ] [ ] [ ]
Name this new matching function "dsa_switch_host_address_match" since we
will be reusing it soon for host FDB entries as well.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-06-29 14:06:49 +00:00
|
|
|
}
|
|
|
|
|
net: dsa: add explicit support for host bridge VLANs
Currently, DSA programs VLANs on shared (DSA and CPU) ports each time it
does so on user ports. This is good for basic functionality but has
several limitations:
- the VLAN group which must reach the CPU may be radically different
from the VLAN group that must be autonomously forwarded by the switch.
In other words, the admin may want to isolate noisy stations and avoid
traffic from them going to the control processor of the switch, where
it would just waste useless cycles. The bridge already supports
independent control of VLAN groups on bridge ports and on the bridge
itself, and when VLAN-aware, it will drop packets in software anyway
if their VID isn't added as a 'self' entry towards the bridge device.
- Replaying host FDB entries may depend, for some drivers like mv88e6xxx,
on replaying the host VLANs as well. The 2 VLAN groups are
approximately the same in most regular cases, but there are corner
cases when timing matters, and DSA's approximation of replicating
VLANs on shared ports simply does not work.
- If a user makes the bridge (implicitly the CPU port) join a VLAN by
accident, there is no way for the CPU port to isolate itself from that
noisy VLAN except by rebooting the system. This is because for each
VLAN added on a user port, DSA will add it on shared ports too, but
for each VLAN deletion on a user port, it will remain installed on
shared ports, since DSA has no good indication of whether the VLAN is
still in use or not.
Now that the bridge driver emits well-balanced SWITCHDEV_OBJ_ID_PORT_VLAN
addition and removal events, DSA has a simple and straightforward task
of separating the bridge port VLANs (these have an orig_dev which is a
DSA slave interface, or a LAG interface) from the host VLANs (these have
an orig_dev which is a bridge interface), and to keep a simple reference
count of each VID on each shared port.
Forwarding VLANs must be installed on the bridge ports and on all DSA
ports interconnecting them. We don't have a good view of the exact
topology, so we simply install forwarding VLANs on all DSA ports, which
is what has been done until now.
Host VLANs must be installed primarily on the dedicated CPU port of each
bridge port. More subtly, they must also be installed on upstream-facing
and downstream-facing DSA ports that are connecting the bridge ports and
the CPU. This ensures that the mv88e6xxx's problem (VID of host FDB
entry may be absent from VTU) is still addressed even if that switch is
in a cross-chip setup, and it has no local CPU port.
Therefore:
- user ports contain only bridge port (forwarding) VLANs, and no
refcounting is necessary
- DSA ports contain both forwarding and host VLANs. Refcounting is
necessary among these 2 types.
- CPU ports contain only host VLANs. Refcounting is also necessary.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-02-15 17:02:17 +00:00
|
|
|
/* Port VLANs match on the targeted port and on all DSA ports */
|
2021-10-20 17:49:53 +00:00
|
|
|
static bool dsa_port_vlan_match(struct dsa_port *dp,
|
|
|
|
struct dsa_notifier_vlan_info *info)
|
net: dsa: remove bitmap operations
The bitmap operations were introduced to simplify the switch drivers
in the future, since most of them could implement the common VLAN and
MDB operations (add, del, dump) with simple functions taking all target
ports at once, and thus limiting the number of hardware accesses.
Programming an MDB or VLAN this way in a single operation would clearly
simplify the drivers a lot but would require a new get-set interface
in DSA. The usage of such bitmap from the stack also raised concerned
in the past, leading to the dynamic allocation of a new ds->_bitmap
member in the dsa_switch structure. So let's get rid of them for now.
This commit nicely wraps the ds->ops->port_{mdb,vlan}_{prepare,add}
switch operations into new dsa_switch_{mdb,vlan}_{prepare,add}
variants not using any bitmap argument anymore.
New dsa_switch_{mdb,vlan}_match helpers have been introduced to make
clear which local port of a switch must be programmed with the target
object. While the targeted user port is an obvious candidate, the
DSA links must also be programmed, as well as the CPU port for VLANs.
While at it, also remove local variables that are only used once.
Signed-off-by: Vivien Didelot <vivien.didelot@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2019-08-25 17:25:15 +00:00
|
|
|
{
|
net: dsa: make cross-chip notifiers more efficient for host events
To determine whether a given port should react to the port targeted by
the notifier, dsa_port_host_vlan_match() and dsa_port_host_address_match()
look at the positioning of the switch port currently executing the
notifier relative to the switch port for which the notifier was emitted.
To maintain stylistic compatibility with the other match functions from
switch.c, the host address and host VLAN match functions take the
notifier information about targeted port, switch and tree indices as
argument. However, these functions only use that information to retrieve
the struct dsa_port *targeted_dp, which is an invariant for the outer
loop that calls them. So it makes more sense to calculate the targeted
dp only once, and pass it to them as argument.
But furthermore, the targeted dp is actually known at the time the call
to dsa_port_notify() is made. It is just that we decide to only save the
indices of the port, switch and tree in the notifier structure, just to
retrace our steps and find the dp again using dsa_switch_find() and
dsa_to_port().
But both the above functions are relatively expensive, since they need
to iterate through lists. It appears more straightforward to make all
notifiers just pass the targeted dp inside their info structure, and
have the code that needs the indices to look at info->dp->index instead
of info->port, or info->dp->ds->index instead of info->sw_index, or
info->dp->ds->dst->index instead of info->tree_index.
For the sake of consistency, all cross-chip notifiers are converted to
pass the "dp" directly.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-04-15 15:46:22 +00:00
|
|
|
return dsa_port_is_dsa(dp) || dp == info->dp;
|
net: dsa: remove bitmap operations
The bitmap operations were introduced to simplify the switch drivers
in the future, since most of them could implement the common VLAN and
MDB operations (add, del, dump) with simple functions taking all target
ports at once, and thus limiting the number of hardware accesses.
Programming an MDB or VLAN this way in a single operation would clearly
simplify the drivers a lot but would require a new get-set interface
in DSA. The usage of such bitmap from the stack also raised concerned
in the past, leading to the dynamic allocation of a new ds->_bitmap
member in the dsa_switch structure. So let's get rid of them for now.
This commit nicely wraps the ds->ops->port_{mdb,vlan}_{prepare,add}
switch operations into new dsa_switch_{mdb,vlan}_{prepare,add}
variants not using any bitmap argument anymore.
New dsa_switch_{mdb,vlan}_match helpers have been introduced to make
clear which local port of a switch must be programmed with the target
object. While the targeted user port is an obvious candidate, the
DSA links must also be programmed, as well as the CPU port for VLANs.
While at it, also remove local variables that are only used once.
Signed-off-by: Vivien Didelot <vivien.didelot@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2019-08-25 17:25:15 +00:00
|
|
|
}
|
|
|
|
|
net: dsa: add explicit support for host bridge VLANs
Currently, DSA programs VLANs on shared (DSA and CPU) ports each time it
does so on user ports. This is good for basic functionality but has
several limitations:
- the VLAN group which must reach the CPU may be radically different
from the VLAN group that must be autonomously forwarded by the switch.
In other words, the admin may want to isolate noisy stations and avoid
traffic from them going to the control processor of the switch, where
it would just waste useless cycles. The bridge already supports
independent control of VLAN groups on bridge ports and on the bridge
itself, and when VLAN-aware, it will drop packets in software anyway
if their VID isn't added as a 'self' entry towards the bridge device.
- Replaying host FDB entries may depend, for some drivers like mv88e6xxx,
on replaying the host VLANs as well. The 2 VLAN groups are
approximately the same in most regular cases, but there are corner
cases when timing matters, and DSA's approximation of replicating
VLANs on shared ports simply does not work.
- If a user makes the bridge (implicitly the CPU port) join a VLAN by
accident, there is no way for the CPU port to isolate itself from that
noisy VLAN except by rebooting the system. This is because for each
VLAN added on a user port, DSA will add it on shared ports too, but
for each VLAN deletion on a user port, it will remain installed on
shared ports, since DSA has no good indication of whether the VLAN is
still in use or not.
Now that the bridge driver emits well-balanced SWITCHDEV_OBJ_ID_PORT_VLAN
addition and removal events, DSA has a simple and straightforward task
of separating the bridge port VLANs (these have an orig_dev which is a
DSA slave interface, or a LAG interface) from the host VLANs (these have
an orig_dev which is a bridge interface), and to keep a simple reference
count of each VID on each shared port.
Forwarding VLANs must be installed on the bridge ports and on all DSA
ports interconnecting them. We don't have a good view of the exact
topology, so we simply install forwarding VLANs on all DSA ports, which
is what has been done until now.
Host VLANs must be installed primarily on the dedicated CPU port of each
bridge port. More subtly, they must also be installed on upstream-facing
and downstream-facing DSA ports that are connecting the bridge ports and
the CPU. This ensures that the mv88e6xxx's problem (VID of host FDB
entry may be absent from VTU) is still addressed even if that switch is
in a cross-chip setup, and it has no local CPU port.
Therefore:
- user ports contain only bridge port (forwarding) VLANs, and no
refcounting is necessary
- DSA ports contain both forwarding and host VLANs. Refcounting is
necessary among these 2 types.
- CPU ports contain only host VLANs. Refcounting is also necessary.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-02-15 17:02:17 +00:00
|
|
|
/* Host VLANs match on the targeted port's CPU port, and on all DSA ports
|
|
|
|
* (upstream and downstream) of that switch and its upstream switches.
|
|
|
|
*/
|
|
|
|
static bool dsa_port_host_vlan_match(struct dsa_port *dp,
|
net: dsa: make cross-chip notifiers more efficient for host events
To determine whether a given port should react to the port targeted by
the notifier, dsa_port_host_vlan_match() and dsa_port_host_address_match()
look at the positioning of the switch port currently executing the
notifier relative to the switch port for which the notifier was emitted.
To maintain stylistic compatibility with the other match functions from
switch.c, the host address and host VLAN match functions take the
notifier information about targeted port, switch and tree indices as
argument. However, these functions only use that information to retrieve
the struct dsa_port *targeted_dp, which is an invariant for the outer
loop that calls them. So it makes more sense to calculate the targeted
dp only once, and pass it to them as argument.
But furthermore, the targeted dp is actually known at the time the call
to dsa_port_notify() is made. It is just that we decide to only save the
indices of the port, switch and tree in the notifier structure, just to
retrace our steps and find the dp again using dsa_switch_find() and
dsa_to_port().
But both the above functions are relatively expensive, since they need
to iterate through lists. It appears more straightforward to make all
notifiers just pass the targeted dp inside their info structure, and
have the code that needs the indices to look at info->dp->index instead
of info->port, or info->dp->ds->index instead of info->sw_index, or
info->dp->ds->dst->index instead of info->tree_index.
For the sake of consistency, all cross-chip notifiers are converted to
pass the "dp" directly.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-04-15 15:46:22 +00:00
|
|
|
const struct dsa_port *targeted_dp)
|
net: dsa: add explicit support for host bridge VLANs
Currently, DSA programs VLANs on shared (DSA and CPU) ports each time it
does so on user ports. This is good for basic functionality but has
several limitations:
- the VLAN group which must reach the CPU may be radically different
from the VLAN group that must be autonomously forwarded by the switch.
In other words, the admin may want to isolate noisy stations and avoid
traffic from them going to the control processor of the switch, where
it would just waste useless cycles. The bridge already supports
independent control of VLAN groups on bridge ports and on the bridge
itself, and when VLAN-aware, it will drop packets in software anyway
if their VID isn't added as a 'self' entry towards the bridge device.
- Replaying host FDB entries may depend, for some drivers like mv88e6xxx,
on replaying the host VLANs as well. The 2 VLAN groups are
approximately the same in most regular cases, but there are corner
cases when timing matters, and DSA's approximation of replicating
VLANs on shared ports simply does not work.
- If a user makes the bridge (implicitly the CPU port) join a VLAN by
accident, there is no way for the CPU port to isolate itself from that
noisy VLAN except by rebooting the system. This is because for each
VLAN added on a user port, DSA will add it on shared ports too, but
for each VLAN deletion on a user port, it will remain installed on
shared ports, since DSA has no good indication of whether the VLAN is
still in use or not.
Now that the bridge driver emits well-balanced SWITCHDEV_OBJ_ID_PORT_VLAN
addition and removal events, DSA has a simple and straightforward task
of separating the bridge port VLANs (these have an orig_dev which is a
DSA slave interface, or a LAG interface) from the host VLANs (these have
an orig_dev which is a bridge interface), and to keep a simple reference
count of each VID on each shared port.
Forwarding VLANs must be installed on the bridge ports and on all DSA
ports interconnecting them. We don't have a good view of the exact
topology, so we simply install forwarding VLANs on all DSA ports, which
is what has been done until now.
Host VLANs must be installed primarily on the dedicated CPU port of each
bridge port. More subtly, they must also be installed on upstream-facing
and downstream-facing DSA ports that are connecting the bridge ports and
the CPU. This ensures that the mv88e6xxx's problem (VID of host FDB
entry may be absent from VTU) is still addressed even if that switch is
in a cross-chip setup, and it has no local CPU port.
Therefore:
- user ports contain only bridge port (forwarding) VLANs, and no
refcounting is necessary
- DSA ports contain both forwarding and host VLANs. Refcounting is
necessary among these 2 types.
- CPU ports contain only host VLANs. Refcounting is also necessary.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-02-15 17:02:17 +00:00
|
|
|
{
|
net: dsa: make cross-chip notifiers more efficient for host events
To determine whether a given port should react to the port targeted by
the notifier, dsa_port_host_vlan_match() and dsa_port_host_address_match()
look at the positioning of the switch port currently executing the
notifier relative to the switch port for which the notifier was emitted.
To maintain stylistic compatibility with the other match functions from
switch.c, the host address and host VLAN match functions take the
notifier information about targeted port, switch and tree indices as
argument. However, these functions only use that information to retrieve
the struct dsa_port *targeted_dp, which is an invariant for the outer
loop that calls them. So it makes more sense to calculate the targeted
dp only once, and pass it to them as argument.
But furthermore, the targeted dp is actually known at the time the call
to dsa_port_notify() is made. It is just that we decide to only save the
indices of the port, switch and tree in the notifier structure, just to
retrace our steps and find the dp again using dsa_switch_find() and
dsa_to_port().
But both the above functions are relatively expensive, since they need
to iterate through lists. It appears more straightforward to make all
notifiers just pass the targeted dp inside their info structure, and
have the code that needs the indices to look at info->dp->index instead
of info->port, or info->dp->ds->index instead of info->sw_index, or
info->dp->ds->dst->index instead of info->tree_index.
For the sake of consistency, all cross-chip notifiers are converted to
pass the "dp" directly.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-04-15 15:46:22 +00:00
|
|
|
struct dsa_port *cpu_dp = targeted_dp->cpu_dp;
|
net: dsa: add explicit support for host bridge VLANs
Currently, DSA programs VLANs on shared (DSA and CPU) ports each time it
does so on user ports. This is good for basic functionality but has
several limitations:
- the VLAN group which must reach the CPU may be radically different
from the VLAN group that must be autonomously forwarded by the switch.
In other words, the admin may want to isolate noisy stations and avoid
traffic from them going to the control processor of the switch, where
it would just waste useless cycles. The bridge already supports
independent control of VLAN groups on bridge ports and on the bridge
itself, and when VLAN-aware, it will drop packets in software anyway
if their VID isn't added as a 'self' entry towards the bridge device.
- Replaying host FDB entries may depend, for some drivers like mv88e6xxx,
on replaying the host VLANs as well. The 2 VLAN groups are
approximately the same in most regular cases, but there are corner
cases when timing matters, and DSA's approximation of replicating
VLANs on shared ports simply does not work.
- If a user makes the bridge (implicitly the CPU port) join a VLAN by
accident, there is no way for the CPU port to isolate itself from that
noisy VLAN except by rebooting the system. This is because for each
VLAN added on a user port, DSA will add it on shared ports too, but
for each VLAN deletion on a user port, it will remain installed on
shared ports, since DSA has no good indication of whether the VLAN is
still in use or not.
Now that the bridge driver emits well-balanced SWITCHDEV_OBJ_ID_PORT_VLAN
addition and removal events, DSA has a simple and straightforward task
of separating the bridge port VLANs (these have an orig_dev which is a
DSA slave interface, or a LAG interface) from the host VLANs (these have
an orig_dev which is a bridge interface), and to keep a simple reference
count of each VID on each shared port.
Forwarding VLANs must be installed on the bridge ports and on all DSA
ports interconnecting them. We don't have a good view of the exact
topology, so we simply install forwarding VLANs on all DSA ports, which
is what has been done until now.
Host VLANs must be installed primarily on the dedicated CPU port of each
bridge port. More subtly, they must also be installed on upstream-facing
and downstream-facing DSA ports that are connecting the bridge ports and
the CPU. This ensures that the mv88e6xxx's problem (VID of host FDB
entry may be absent from VTU) is still addressed even if that switch is
in a cross-chip setup, and it has no local CPU port.
Therefore:
- user ports contain only bridge port (forwarding) VLANs, and no
refcounting is necessary
- DSA ports contain both forwarding and host VLANs. Refcounting is
necessary among these 2 types.
- CPU ports contain only host VLANs. Refcounting is also necessary.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-02-15 17:02:17 +00:00
|
|
|
|
net: dsa: make cross-chip notifiers more efficient for host events
To determine whether a given port should react to the port targeted by
the notifier, dsa_port_host_vlan_match() and dsa_port_host_address_match()
look at the positioning of the switch port currently executing the
notifier relative to the switch port for which the notifier was emitted.
To maintain stylistic compatibility with the other match functions from
switch.c, the host address and host VLAN match functions take the
notifier information about targeted port, switch and tree indices as
argument. However, these functions only use that information to retrieve
the struct dsa_port *targeted_dp, which is an invariant for the outer
loop that calls them. So it makes more sense to calculate the targeted
dp only once, and pass it to them as argument.
But furthermore, the targeted dp is actually known at the time the call
to dsa_port_notify() is made. It is just that we decide to only save the
indices of the port, switch and tree in the notifier structure, just to
retrace our steps and find the dp again using dsa_switch_find() and
dsa_to_port().
But both the above functions are relatively expensive, since they need
to iterate through lists. It appears more straightforward to make all
notifiers just pass the targeted dp inside their info structure, and
have the code that needs the indices to look at info->dp->index instead
of info->port, or info->dp->ds->index instead of info->sw_index, or
info->dp->ds->dst->index instead of info->tree_index.
For the sake of consistency, all cross-chip notifiers are converted to
pass the "dp" directly.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-04-15 15:46:22 +00:00
|
|
|
if (dsa_switch_is_upstream_of(dp->ds, targeted_dp->ds))
|
net: dsa: add explicit support for host bridge VLANs
Currently, DSA programs VLANs on shared (DSA and CPU) ports each time it
does so on user ports. This is good for basic functionality but has
several limitations:
- the VLAN group which must reach the CPU may be radically different
from the VLAN group that must be autonomously forwarded by the switch.
In other words, the admin may want to isolate noisy stations and avoid
traffic from them going to the control processor of the switch, where
it would just waste useless cycles. The bridge already supports
independent control of VLAN groups on bridge ports and on the bridge
itself, and when VLAN-aware, it will drop packets in software anyway
if their VID isn't added as a 'self' entry towards the bridge device.
- Replaying host FDB entries may depend, for some drivers like mv88e6xxx,
on replaying the host VLANs as well. The 2 VLAN groups are
approximately the same in most regular cases, but there are corner
cases when timing matters, and DSA's approximation of replicating
VLANs on shared ports simply does not work.
- If a user makes the bridge (implicitly the CPU port) join a VLAN by
accident, there is no way for the CPU port to isolate itself from that
noisy VLAN except by rebooting the system. This is because for each
VLAN added on a user port, DSA will add it on shared ports too, but
for each VLAN deletion on a user port, it will remain installed on
shared ports, since DSA has no good indication of whether the VLAN is
still in use or not.
Now that the bridge driver emits well-balanced SWITCHDEV_OBJ_ID_PORT_VLAN
addition and removal events, DSA has a simple and straightforward task
of separating the bridge port VLANs (these have an orig_dev which is a
DSA slave interface, or a LAG interface) from the host VLANs (these have
an orig_dev which is a bridge interface), and to keep a simple reference
count of each VID on each shared port.
Forwarding VLANs must be installed on the bridge ports and on all DSA
ports interconnecting them. We don't have a good view of the exact
topology, so we simply install forwarding VLANs on all DSA ports, which
is what has been done until now.
Host VLANs must be installed primarily on the dedicated CPU port of each
bridge port. More subtly, they must also be installed on upstream-facing
and downstream-facing DSA ports that are connecting the bridge ports and
the CPU. This ensures that the mv88e6xxx's problem (VID of host FDB
entry may be absent from VTU) is still addressed even if that switch is
in a cross-chip setup, and it has no local CPU port.
Therefore:
- user ports contain only bridge port (forwarding) VLANs, and no
refcounting is necessary
- DSA ports contain both forwarding and host VLANs. Refcounting is
necessary among these 2 types.
- CPU ports contain only host VLANs. Refcounting is also necessary.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-02-15 17:02:17 +00:00
|
|
|
return dsa_port_is_dsa(dp) || dp == cpu_dp;
|
|
|
|
|
|
|
|
return false;
|
|
|
|
}
|
|
|
|
|
|
|
|
static struct dsa_vlan *dsa_vlan_find(struct list_head *vlan_list,
|
|
|
|
const struct switchdev_obj_port_vlan *vlan)
|
|
|
|
{
|
|
|
|
struct dsa_vlan *v;
|
|
|
|
|
|
|
|
list_for_each_entry(v, vlan_list, list)
|
|
|
|
if (v->vid == vlan->vid)
|
|
|
|
return v;
|
|
|
|
|
|
|
|
return NULL;
|
|
|
|
}
|
|
|
|
|
|
|
|
static int dsa_port_do_vlan_add(struct dsa_port *dp,
|
|
|
|
const struct switchdev_obj_port_vlan *vlan,
|
|
|
|
struct netlink_ext_ack *extack)
|
|
|
|
{
|
|
|
|
struct dsa_switch *ds = dp->ds;
|
|
|
|
int port = dp->index;
|
|
|
|
struct dsa_vlan *v;
|
|
|
|
int err = 0;
|
|
|
|
|
|
|
|
/* No need to bother with refcounting for user ports. */
|
|
|
|
if (!(dsa_port_is_cpu(dp) || dsa_port_is_dsa(dp)))
|
|
|
|
return ds->ops->port_vlan_add(ds, port, vlan, extack);
|
|
|
|
|
|
|
|
/* No need to propagate on shared ports the existing VLANs that were
|
|
|
|
* re-notified after just the flags have changed. This would cause a
|
|
|
|
* refcount bump which we need to avoid, since it unbalances the
|
|
|
|
* additions with the deletions.
|
|
|
|
*/
|
|
|
|
if (vlan->changed)
|
|
|
|
return 0;
|
|
|
|
|
|
|
|
mutex_lock(&dp->vlans_lock);
|
|
|
|
|
|
|
|
v = dsa_vlan_find(&dp->vlans, vlan);
|
|
|
|
if (v) {
|
|
|
|
refcount_inc(&v->refcount);
|
|
|
|
goto out;
|
|
|
|
}
|
|
|
|
|
|
|
|
v = kzalloc(sizeof(*v), GFP_KERNEL);
|
|
|
|
if (!v) {
|
|
|
|
err = -ENOMEM;
|
|
|
|
goto out;
|
|
|
|
}
|
|
|
|
|
|
|
|
err = ds->ops->port_vlan_add(ds, port, vlan, extack);
|
|
|
|
if (err) {
|
|
|
|
kfree(v);
|
|
|
|
goto out;
|
|
|
|
}
|
|
|
|
|
|
|
|
v->vid = vlan->vid;
|
|
|
|
refcount_set(&v->refcount, 1);
|
|
|
|
list_add_tail(&v->list, &dp->vlans);
|
|
|
|
|
|
|
|
out:
|
|
|
|
mutex_unlock(&dp->vlans_lock);
|
|
|
|
|
|
|
|
return err;
|
|
|
|
}
|
|
|
|
|
|
|
|
static int dsa_port_do_vlan_del(struct dsa_port *dp,
|
|
|
|
const struct switchdev_obj_port_vlan *vlan)
|
|
|
|
{
|
|
|
|
struct dsa_switch *ds = dp->ds;
|
|
|
|
int port = dp->index;
|
|
|
|
struct dsa_vlan *v;
|
|
|
|
int err = 0;
|
|
|
|
|
|
|
|
/* No need to bother with refcounting for user ports */
|
|
|
|
if (!(dsa_port_is_cpu(dp) || dsa_port_is_dsa(dp)))
|
|
|
|
return ds->ops->port_vlan_del(ds, port, vlan);
|
|
|
|
|
|
|
|
mutex_lock(&dp->vlans_lock);
|
|
|
|
|
|
|
|
v = dsa_vlan_find(&dp->vlans, vlan);
|
|
|
|
if (!v) {
|
|
|
|
err = -ENOENT;
|
|
|
|
goto out;
|
|
|
|
}
|
|
|
|
|
|
|
|
if (!refcount_dec_and_test(&v->refcount))
|
|
|
|
goto out;
|
|
|
|
|
|
|
|
err = ds->ops->port_vlan_del(ds, port, vlan);
|
|
|
|
if (err) {
|
|
|
|
refcount_set(&v->refcount, 1);
|
|
|
|
goto out;
|
|
|
|
}
|
|
|
|
|
|
|
|
list_del(&v->list);
|
|
|
|
kfree(v);
|
|
|
|
|
|
|
|
out:
|
|
|
|
mutex_unlock(&dp->vlans_lock);
|
|
|
|
|
|
|
|
return err;
|
|
|
|
}
|
|
|
|
|
net: switchdev: remove the transaction structure from port object notifiers
Since the introduction of the switchdev API, port objects were
transmitted to drivers for offloading using a two-step transactional
model, with a prepare phase that was supposed to catch all errors, and a
commit phase that was supposed to never fail.
Some classes of failures can never be avoided, like hardware access, or
memory allocation. In the latter case, merely attempting to move the
memory allocation to the preparation phase makes it impossible to avoid
memory leaks, since commit 91cf8eceffc1 ("switchdev: Remove unused
transaction item queue") which has removed the unused mechanism of
passing on the allocated memory between one phase and another.
It is time we admit that separating the preparation from the commit
phase is something that is best left for the driver to decide, and not
something that should be baked into the API, especially since there are
no switchdev callers that depend on this.
This patch removes the struct switchdev_trans member from switchdev port
object notifier structures, and converts drivers to not look at this
member.
Where driver conversion is trivial (like in the case of the Marvell
Prestera driver, NXP DPAA2 switch, TI CPSW, and Rocker drivers), it is
done in this patch.
Where driver conversion needs more attention (DSA, Mellanox Spectrum),
the conversion is left for subsequent patches and here we only fake the
prepare/commit phases at a lower level, just not in the switchdev
notifier itself.
Where the code has a natural structure that is best left alone as a
preparation and a commit phase (as in the case of the Ocelot switch),
that structure is left in place, just made to not depend upon the
switchdev transactional model.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Acked-by: Linus Walleij <linus.walleij@linaro.org>
Acked-by: Jiri Pirko <jiri@nvidia.com>
Reviewed-by: Ido Schimmel <idosch@nvidia.com>
Signed-off-by: Jakub Kicinski <kuba@kernel.org>
2021-01-09 00:01:48 +00:00
|
|
|
static int dsa_switch_vlan_add(struct dsa_switch *ds,
|
|
|
|
struct dsa_notifier_vlan_info *info)
|
2017-11-30 16:23:59 +00:00
|
|
|
{
|
2021-10-20 17:49:53 +00:00
|
|
|
struct dsa_port *dp;
|
|
|
|
int err;
|
2017-11-30 16:23:59 +00:00
|
|
|
|
2021-01-09 00:01:53 +00:00
|
|
|
if (!ds->ops->port_vlan_add)
|
2017-11-30 16:23:59 +00:00
|
|
|
return -EOPNOTSUPP;
|
|
|
|
|
2021-10-20 17:49:53 +00:00
|
|
|
dsa_switch_for_each_port(dp, ds) {
|
|
|
|
if (dsa_port_vlan_match(dp, info)) {
|
net: dsa: add explicit support for host bridge VLANs
Currently, DSA programs VLANs on shared (DSA and CPU) ports each time it
does so on user ports. This is good for basic functionality but has
several limitations:
- the VLAN group which must reach the CPU may be radically different
from the VLAN group that must be autonomously forwarded by the switch.
In other words, the admin may want to isolate noisy stations and avoid
traffic from them going to the control processor of the switch, where
it would just waste useless cycles. The bridge already supports
independent control of VLAN groups on bridge ports and on the bridge
itself, and when VLAN-aware, it will drop packets in software anyway
if their VID isn't added as a 'self' entry towards the bridge device.
- Replaying host FDB entries may depend, for some drivers like mv88e6xxx,
on replaying the host VLANs as well. The 2 VLAN groups are
approximately the same in most regular cases, but there are corner
cases when timing matters, and DSA's approximation of replicating
VLANs on shared ports simply does not work.
- If a user makes the bridge (implicitly the CPU port) join a VLAN by
accident, there is no way for the CPU port to isolate itself from that
noisy VLAN except by rebooting the system. This is because for each
VLAN added on a user port, DSA will add it on shared ports too, but
for each VLAN deletion on a user port, it will remain installed on
shared ports, since DSA has no good indication of whether the VLAN is
still in use or not.
Now that the bridge driver emits well-balanced SWITCHDEV_OBJ_ID_PORT_VLAN
addition and removal events, DSA has a simple and straightforward task
of separating the bridge port VLANs (these have an orig_dev which is a
DSA slave interface, or a LAG interface) from the host VLANs (these have
an orig_dev which is a bridge interface), and to keep a simple reference
count of each VID on each shared port.
Forwarding VLANs must be installed on the bridge ports and on all DSA
ports interconnecting them. We don't have a good view of the exact
topology, so we simply install forwarding VLANs on all DSA ports, which
is what has been done until now.
Host VLANs must be installed primarily on the dedicated CPU port of each
bridge port. More subtly, they must also be installed on upstream-facing
and downstream-facing DSA ports that are connecting the bridge ports and
the CPU. This ensures that the mv88e6xxx's problem (VID of host FDB
entry may be absent from VTU) is still addressed even if that switch is
in a cross-chip setup, and it has no local CPU port.
Therefore:
- user ports contain only bridge port (forwarding) VLANs, and no
refcounting is necessary
- DSA ports contain both forwarding and host VLANs. Refcounting is
necessary among these 2 types.
- CPU ports contain only host VLANs. Refcounting is also necessary.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-02-15 17:02:17 +00:00
|
|
|
err = dsa_port_do_vlan_add(dp, info->vlan,
|
|
|
|
info->extack);
|
net: dsa: remove bitmap operations
The bitmap operations were introduced to simplify the switch drivers
in the future, since most of them could implement the common VLAN and
MDB operations (add, del, dump) with simple functions taking all target
ports at once, and thus limiting the number of hardware accesses.
Programming an MDB or VLAN this way in a single operation would clearly
simplify the drivers a lot but would require a new get-set interface
in DSA. The usage of such bitmap from the stack also raised concerned
in the past, leading to the dynamic allocation of a new ds->_bitmap
member in the dsa_switch structure. So let's get rid of them for now.
This commit nicely wraps the ds->ops->port_{mdb,vlan}_{prepare,add}
switch operations into new dsa_switch_{mdb,vlan}_{prepare,add}
variants not using any bitmap argument anymore.
New dsa_switch_{mdb,vlan}_match helpers have been introduced to make
clear which local port of a switch must be programmed with the target
object. While the targeted user port is an obvious candidate, the
DSA links must also be programmed, as well as the CPU port for VLANs.
While at it, also remove local variables that are only used once.
Signed-off-by: Vivien Didelot <vivien.didelot@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2019-08-25 17:25:15 +00:00
|
|
|
if (err)
|
|
|
|
return err;
|
|
|
|
}
|
2017-11-30 16:23:59 +00:00
|
|
|
}
|
|
|
|
|
2017-05-19 21:00:55 +00:00
|
|
|
return 0;
|
|
|
|
}
|
|
|
|
|
|
|
|
static int dsa_switch_vlan_del(struct dsa_switch *ds,
|
|
|
|
struct dsa_notifier_vlan_info *info)
|
|
|
|
{
|
net: dsa: add explicit support for host bridge VLANs
Currently, DSA programs VLANs on shared (DSA and CPU) ports each time it
does so on user ports. This is good for basic functionality but has
several limitations:
- the VLAN group which must reach the CPU may be radically different
from the VLAN group that must be autonomously forwarded by the switch.
In other words, the admin may want to isolate noisy stations and avoid
traffic from them going to the control processor of the switch, where
it would just waste useless cycles. The bridge already supports
independent control of VLAN groups on bridge ports and on the bridge
itself, and when VLAN-aware, it will drop packets in software anyway
if their VID isn't added as a 'self' entry towards the bridge device.
- Replaying host FDB entries may depend, for some drivers like mv88e6xxx,
on replaying the host VLANs as well. The 2 VLAN groups are
approximately the same in most regular cases, but there are corner
cases when timing matters, and DSA's approximation of replicating
VLANs on shared ports simply does not work.
- If a user makes the bridge (implicitly the CPU port) join a VLAN by
accident, there is no way for the CPU port to isolate itself from that
noisy VLAN except by rebooting the system. This is because for each
VLAN added on a user port, DSA will add it on shared ports too, but
for each VLAN deletion on a user port, it will remain installed on
shared ports, since DSA has no good indication of whether the VLAN is
still in use or not.
Now that the bridge driver emits well-balanced SWITCHDEV_OBJ_ID_PORT_VLAN
addition and removal events, DSA has a simple and straightforward task
of separating the bridge port VLANs (these have an orig_dev which is a
DSA slave interface, or a LAG interface) from the host VLANs (these have
an orig_dev which is a bridge interface), and to keep a simple reference
count of each VID on each shared port.
Forwarding VLANs must be installed on the bridge ports and on all DSA
ports interconnecting them. We don't have a good view of the exact
topology, so we simply install forwarding VLANs on all DSA ports, which
is what has been done until now.
Host VLANs must be installed primarily on the dedicated CPU port of each
bridge port. More subtly, they must also be installed on upstream-facing
and downstream-facing DSA ports that are connecting the bridge ports and
the CPU. This ensures that the mv88e6xxx's problem (VID of host FDB
entry may be absent from VTU) is still addressed even if that switch is
in a cross-chip setup, and it has no local CPU port.
Therefore:
- user ports contain only bridge port (forwarding) VLANs, and no
refcounting is necessary
- DSA ports contain both forwarding and host VLANs. Refcounting is
necessary among these 2 types.
- CPU ports contain only host VLANs. Refcounting is also necessary.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-02-15 17:02:17 +00:00
|
|
|
struct dsa_port *dp;
|
|
|
|
int err;
|
|
|
|
|
2017-05-19 21:00:55 +00:00
|
|
|
if (!ds->ops->port_vlan_del)
|
|
|
|
return -EOPNOTSUPP;
|
|
|
|
|
net: dsa: add explicit support for host bridge VLANs
Currently, DSA programs VLANs on shared (DSA and CPU) ports each time it
does so on user ports. This is good for basic functionality but has
several limitations:
- the VLAN group which must reach the CPU may be radically different
from the VLAN group that must be autonomously forwarded by the switch.
In other words, the admin may want to isolate noisy stations and avoid
traffic from them going to the control processor of the switch, where
it would just waste useless cycles. The bridge already supports
independent control of VLAN groups on bridge ports and on the bridge
itself, and when VLAN-aware, it will drop packets in software anyway
if their VID isn't added as a 'self' entry towards the bridge device.
- Replaying host FDB entries may depend, for some drivers like mv88e6xxx,
on replaying the host VLANs as well. The 2 VLAN groups are
approximately the same in most regular cases, but there are corner
cases when timing matters, and DSA's approximation of replicating
VLANs on shared ports simply does not work.
- If a user makes the bridge (implicitly the CPU port) join a VLAN by
accident, there is no way for the CPU port to isolate itself from that
noisy VLAN except by rebooting the system. This is because for each
VLAN added on a user port, DSA will add it on shared ports too, but
for each VLAN deletion on a user port, it will remain installed on
shared ports, since DSA has no good indication of whether the VLAN is
still in use or not.
Now that the bridge driver emits well-balanced SWITCHDEV_OBJ_ID_PORT_VLAN
addition and removal events, DSA has a simple and straightforward task
of separating the bridge port VLANs (these have an orig_dev which is a
DSA slave interface, or a LAG interface) from the host VLANs (these have
an orig_dev which is a bridge interface), and to keep a simple reference
count of each VID on each shared port.
Forwarding VLANs must be installed on the bridge ports and on all DSA
ports interconnecting them. We don't have a good view of the exact
topology, so we simply install forwarding VLANs on all DSA ports, which
is what has been done until now.
Host VLANs must be installed primarily on the dedicated CPU port of each
bridge port. More subtly, they must also be installed on upstream-facing
and downstream-facing DSA ports that are connecting the bridge ports and
the CPU. This ensures that the mv88e6xxx's problem (VID of host FDB
entry may be absent from VTU) is still addressed even if that switch is
in a cross-chip setup, and it has no local CPU port.
Therefore:
- user ports contain only bridge port (forwarding) VLANs, and no
refcounting is necessary
- DSA ports contain both forwarding and host VLANs. Refcounting is
necessary among these 2 types.
- CPU ports contain only host VLANs. Refcounting is also necessary.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-02-15 17:02:17 +00:00
|
|
|
dsa_switch_for_each_port(dp, ds) {
|
|
|
|
if (dsa_port_vlan_match(dp, info)) {
|
|
|
|
err = dsa_port_do_vlan_del(dp, info->vlan);
|
|
|
|
if (err)
|
|
|
|
return err;
|
|
|
|
}
|
|
|
|
}
|
|
|
|
|
|
|
|
return 0;
|
|
|
|
}
|
|
|
|
|
|
|
|
static int dsa_switch_host_vlan_add(struct dsa_switch *ds,
|
|
|
|
struct dsa_notifier_vlan_info *info)
|
|
|
|
{
|
|
|
|
struct dsa_port *dp;
|
|
|
|
int err;
|
|
|
|
|
|
|
|
if (!ds->ops->port_vlan_add)
|
|
|
|
return -EOPNOTSUPP;
|
|
|
|
|
|
|
|
dsa_switch_for_each_port(dp, ds) {
|
net: dsa: make cross-chip notifiers more efficient for host events
To determine whether a given port should react to the port targeted by
the notifier, dsa_port_host_vlan_match() and dsa_port_host_address_match()
look at the positioning of the switch port currently executing the
notifier relative to the switch port for which the notifier was emitted.
To maintain stylistic compatibility with the other match functions from
switch.c, the host address and host VLAN match functions take the
notifier information about targeted port, switch and tree indices as
argument. However, these functions only use that information to retrieve
the struct dsa_port *targeted_dp, which is an invariant for the outer
loop that calls them. So it makes more sense to calculate the targeted
dp only once, and pass it to them as argument.
But furthermore, the targeted dp is actually known at the time the call
to dsa_port_notify() is made. It is just that we decide to only save the
indices of the port, switch and tree in the notifier structure, just to
retrace our steps and find the dp again using dsa_switch_find() and
dsa_to_port().
But both the above functions are relatively expensive, since they need
to iterate through lists. It appears more straightforward to make all
notifiers just pass the targeted dp inside their info structure, and
have the code that needs the indices to look at info->dp->index instead
of info->port, or info->dp->ds->index instead of info->sw_index, or
info->dp->ds->dst->index instead of info->tree_index.
For the sake of consistency, all cross-chip notifiers are converted to
pass the "dp" directly.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-04-15 15:46:22 +00:00
|
|
|
if (dsa_port_host_vlan_match(dp, info->dp)) {
|
net: dsa: add explicit support for host bridge VLANs
Currently, DSA programs VLANs on shared (DSA and CPU) ports each time it
does so on user ports. This is good for basic functionality but has
several limitations:
- the VLAN group which must reach the CPU may be radically different
from the VLAN group that must be autonomously forwarded by the switch.
In other words, the admin may want to isolate noisy stations and avoid
traffic from them going to the control processor of the switch, where
it would just waste useless cycles. The bridge already supports
independent control of VLAN groups on bridge ports and on the bridge
itself, and when VLAN-aware, it will drop packets in software anyway
if their VID isn't added as a 'self' entry towards the bridge device.
- Replaying host FDB entries may depend, for some drivers like mv88e6xxx,
on replaying the host VLANs as well. The 2 VLAN groups are
approximately the same in most regular cases, but there are corner
cases when timing matters, and DSA's approximation of replicating
VLANs on shared ports simply does not work.
- If a user makes the bridge (implicitly the CPU port) join a VLAN by
accident, there is no way for the CPU port to isolate itself from that
noisy VLAN except by rebooting the system. This is because for each
VLAN added on a user port, DSA will add it on shared ports too, but
for each VLAN deletion on a user port, it will remain installed on
shared ports, since DSA has no good indication of whether the VLAN is
still in use or not.
Now that the bridge driver emits well-balanced SWITCHDEV_OBJ_ID_PORT_VLAN
addition and removal events, DSA has a simple and straightforward task
of separating the bridge port VLANs (these have an orig_dev which is a
DSA slave interface, or a LAG interface) from the host VLANs (these have
an orig_dev which is a bridge interface), and to keep a simple reference
count of each VID on each shared port.
Forwarding VLANs must be installed on the bridge ports and on all DSA
ports interconnecting them. We don't have a good view of the exact
topology, so we simply install forwarding VLANs on all DSA ports, which
is what has been done until now.
Host VLANs must be installed primarily on the dedicated CPU port of each
bridge port. More subtly, they must also be installed on upstream-facing
and downstream-facing DSA ports that are connecting the bridge ports and
the CPU. This ensures that the mv88e6xxx's problem (VID of host FDB
entry may be absent from VTU) is still addressed even if that switch is
in a cross-chip setup, and it has no local CPU port.
Therefore:
- user ports contain only bridge port (forwarding) VLANs, and no
refcounting is necessary
- DSA ports contain both forwarding and host VLANs. Refcounting is
necessary among these 2 types.
- CPU ports contain only host VLANs. Refcounting is also necessary.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-02-15 17:02:17 +00:00
|
|
|
err = dsa_port_do_vlan_add(dp, info->vlan,
|
|
|
|
info->extack);
|
|
|
|
if (err)
|
|
|
|
return err;
|
|
|
|
}
|
|
|
|
}
|
|
|
|
|
|
|
|
return 0;
|
|
|
|
}
|
|
|
|
|
|
|
|
static int dsa_switch_host_vlan_del(struct dsa_switch *ds,
|
|
|
|
struct dsa_notifier_vlan_info *info)
|
|
|
|
{
|
|
|
|
struct dsa_port *dp;
|
|
|
|
int err;
|
|
|
|
|
|
|
|
if (!ds->ops->port_vlan_del)
|
|
|
|
return -EOPNOTSUPP;
|
|
|
|
|
|
|
|
dsa_switch_for_each_port(dp, ds) {
|
net: dsa: make cross-chip notifiers more efficient for host events
To determine whether a given port should react to the port targeted by
the notifier, dsa_port_host_vlan_match() and dsa_port_host_address_match()
look at the positioning of the switch port currently executing the
notifier relative to the switch port for which the notifier was emitted.
To maintain stylistic compatibility with the other match functions from
switch.c, the host address and host VLAN match functions take the
notifier information about targeted port, switch and tree indices as
argument. However, these functions only use that information to retrieve
the struct dsa_port *targeted_dp, which is an invariant for the outer
loop that calls them. So it makes more sense to calculate the targeted
dp only once, and pass it to them as argument.
But furthermore, the targeted dp is actually known at the time the call
to dsa_port_notify() is made. It is just that we decide to only save the
indices of the port, switch and tree in the notifier structure, just to
retrace our steps and find the dp again using dsa_switch_find() and
dsa_to_port().
But both the above functions are relatively expensive, since they need
to iterate through lists. It appears more straightforward to make all
notifiers just pass the targeted dp inside their info structure, and
have the code that needs the indices to look at info->dp->index instead
of info->port, or info->dp->ds->index instead of info->sw_index, or
info->dp->ds->dst->index instead of info->tree_index.
For the sake of consistency, all cross-chip notifiers are converted to
pass the "dp" directly.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-04-15 15:46:22 +00:00
|
|
|
if (dsa_port_host_vlan_match(dp, info->dp)) {
|
net: dsa: add explicit support for host bridge VLANs
Currently, DSA programs VLANs on shared (DSA and CPU) ports each time it
does so on user ports. This is good for basic functionality but has
several limitations:
- the VLAN group which must reach the CPU may be radically different
from the VLAN group that must be autonomously forwarded by the switch.
In other words, the admin may want to isolate noisy stations and avoid
traffic from them going to the control processor of the switch, where
it would just waste useless cycles. The bridge already supports
independent control of VLAN groups on bridge ports and on the bridge
itself, and when VLAN-aware, it will drop packets in software anyway
if their VID isn't added as a 'self' entry towards the bridge device.
- Replaying host FDB entries may depend, for some drivers like mv88e6xxx,
on replaying the host VLANs as well. The 2 VLAN groups are
approximately the same in most regular cases, but there are corner
cases when timing matters, and DSA's approximation of replicating
VLANs on shared ports simply does not work.
- If a user makes the bridge (implicitly the CPU port) join a VLAN by
accident, there is no way for the CPU port to isolate itself from that
noisy VLAN except by rebooting the system. This is because for each
VLAN added on a user port, DSA will add it on shared ports too, but
for each VLAN deletion on a user port, it will remain installed on
shared ports, since DSA has no good indication of whether the VLAN is
still in use or not.
Now that the bridge driver emits well-balanced SWITCHDEV_OBJ_ID_PORT_VLAN
addition and removal events, DSA has a simple and straightforward task
of separating the bridge port VLANs (these have an orig_dev which is a
DSA slave interface, or a LAG interface) from the host VLANs (these have
an orig_dev which is a bridge interface), and to keep a simple reference
count of each VID on each shared port.
Forwarding VLANs must be installed on the bridge ports and on all DSA
ports interconnecting them. We don't have a good view of the exact
topology, so we simply install forwarding VLANs on all DSA ports, which
is what has been done until now.
Host VLANs must be installed primarily on the dedicated CPU port of each
bridge port. More subtly, they must also be installed on upstream-facing
and downstream-facing DSA ports that are connecting the bridge ports and
the CPU. This ensures that the mv88e6xxx's problem (VID of host FDB
entry may be absent from VTU) is still addressed even if that switch is
in a cross-chip setup, and it has no local CPU port.
Therefore:
- user ports contain only bridge port (forwarding) VLANs, and no
refcounting is necessary
- DSA ports contain both forwarding and host VLANs. Refcounting is
necessary among these 2 types.
- CPU ports contain only host VLANs. Refcounting is also necessary.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-02-15 17:02:17 +00:00
|
|
|
err = dsa_port_do_vlan_del(dp, info->vlan);
|
|
|
|
if (err)
|
|
|
|
return err;
|
|
|
|
}
|
|
|
|
}
|
2017-06-07 22:12:14 +00:00
|
|
|
|
|
|
|
return 0;
|
2017-05-19 21:00:55 +00:00
|
|
|
}
|
|
|
|
|
net: dsa: allow changing the tag protocol via the "tagging" device attribute
Currently DSA exposes the following sysfs:
$ cat /sys/class/net/eno2/dsa/tagging
ocelot
which is a read-only device attribute, introduced in the kernel as
commit 98cdb4807123 ("net: dsa: Expose tagging protocol to user-space"),
and used by libpcap since its commit 993db3800d7d ("Add support for DSA
link-layer types").
It would be nice if we could extend this device attribute by making it
writable:
$ echo ocelot-8021q > /sys/class/net/eno2/dsa/tagging
This is useful with DSA switches that can make use of more than one
tagging protocol. It may be useful in dsa_loop in the future too, to
perform offline testing of various taggers, or for changing between dsa
and edsa on Marvell switches, if that is desirable.
In terms of implementation, drivers can support this feature by
implementing .change_tag_protocol, which should always leave the switch
in a consistent state: either with the new protocol if things went well,
or with the old one if something failed. Teardown of the old protocol,
if necessary, must be handled by the driver.
Some things remain as before:
- The .get_tag_protocol is currently only called at probe time, to load
the initial tagging protocol driver. Nonetheless, new drivers should
report the tagging protocol in current use now.
- The driver should manage by itself the initial setup of tagging
protocol, no later than the .setup() method, as well as destroying
resources used by the last tagger in use, no earlier than the
.teardown() method.
For multi-switch DSA trees, error handling is a bit more complicated,
since e.g. the 5th out of 7 switches may fail to change the tag
protocol. When that happens, a revert to the original tag protocol is
attempted, but that may fail too, leaving the tree in an inconsistent
state despite each individual switch implementing .change_tag_protocol
transactionally. Since the intersection between drivers that implement
.change_tag_protocol and drivers that support D in DSA is currently the
empty set, the possibility for this error to happen is ignored for now.
Testing:
$ insmod mscc_felix.ko
[ 79.549784] mscc_felix 0000:00:00.5: Adding to iommu group 14
[ 79.565712] mscc_felix 0000:00:00.5: Failed to register DSA switch: -517
$ insmod tag_ocelot.ko
$ rmmod mscc_felix.ko
$ insmod mscc_felix.ko
[ 97.261724] libphy: VSC9959 internal MDIO bus: probed
[ 97.267363] mscc_felix 0000:00:00.5: Found PCS at internal MDIO address 0
[ 97.274998] mscc_felix 0000:00:00.5: Found PCS at internal MDIO address 1
[ 97.282561] mscc_felix 0000:00:00.5: Found PCS at internal MDIO address 2
[ 97.289700] mscc_felix 0000:00:00.5: Found PCS at internal MDIO address 3
[ 97.599163] mscc_felix 0000:00:00.5 swp0 (uninitialized): PHY [0000:00:00.3:10] driver [Microsemi GE VSC8514 SyncE] (irq=POLL)
[ 97.862034] mscc_felix 0000:00:00.5 swp1 (uninitialized): PHY [0000:00:00.3:11] driver [Microsemi GE VSC8514 SyncE] (irq=POLL)
[ 97.950731] mscc_felix 0000:00:00.5 swp0: configuring for inband/qsgmii link mode
[ 97.964278] 8021q: adding VLAN 0 to HW filter on device swp0
[ 98.146161] mscc_felix 0000:00:00.5 swp2 (uninitialized): PHY [0000:00:00.3:12] driver [Microsemi GE VSC8514 SyncE] (irq=POLL)
[ 98.238649] mscc_felix 0000:00:00.5 swp1: configuring for inband/qsgmii link mode
[ 98.251845] 8021q: adding VLAN 0 to HW filter on device swp1
[ 98.433916] mscc_felix 0000:00:00.5 swp3 (uninitialized): PHY [0000:00:00.3:13] driver [Microsemi GE VSC8514 SyncE] (irq=POLL)
[ 98.485542] mscc_felix 0000:00:00.5: configuring for fixed/internal link mode
[ 98.503584] mscc_felix 0000:00:00.5: Link is Up - 2.5Gbps/Full - flow control rx/tx
[ 98.527948] device eno2 entered promiscuous mode
[ 98.544755] DSA: tree 0 setup
$ ping 10.0.0.1
PING 10.0.0.1 (10.0.0.1): 56 data bytes
64 bytes from 10.0.0.1: seq=0 ttl=64 time=2.337 ms
64 bytes from 10.0.0.1: seq=1 ttl=64 time=0.754 ms
^C
- 10.0.0.1 ping statistics -
2 packets transmitted, 2 packets received, 0% packet loss
round-trip min/avg/max = 0.754/1.545/2.337 ms
$ cat /sys/class/net/eno2/dsa/tagging
ocelot
$ cat ./test_ocelot_8021q.sh
#!/bin/bash
ip link set swp0 down
ip link set swp1 down
ip link set swp2 down
ip link set swp3 down
ip link set swp5 down
ip link set eno2 down
echo ocelot-8021q > /sys/class/net/eno2/dsa/tagging
ip link set eno2 up
ip link set swp0 up
ip link set swp1 up
ip link set swp2 up
ip link set swp3 up
ip link set swp5 up
$ ./test_ocelot_8021q.sh
./test_ocelot_8021q.sh: line 9: echo: write error: Protocol not available
$ rmmod tag_ocelot.ko
rmmod: can't unload module 'tag_ocelot': Resource temporarily unavailable
$ insmod tag_ocelot_8021q.ko
$ ./test_ocelot_8021q.sh
$ cat /sys/class/net/eno2/dsa/tagging
ocelot-8021q
$ rmmod tag_ocelot.ko
$ rmmod tag_ocelot_8021q.ko
rmmod: can't unload module 'tag_ocelot_8021q': Resource temporarily unavailable
$ ping 10.0.0.1
PING 10.0.0.1 (10.0.0.1): 56 data bytes
64 bytes from 10.0.0.1: seq=0 ttl=64 time=0.953 ms
64 bytes from 10.0.0.1: seq=1 ttl=64 time=0.787 ms
64 bytes from 10.0.0.1: seq=2 ttl=64 time=0.771 ms
$ rmmod mscc_felix.ko
[ 645.544426] mscc_felix 0000:00:00.5: Link is Down
[ 645.838608] DSA: tree 0 torn down
$ rmmod tag_ocelot_8021q.ko
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: Jakub Kicinski <kuba@kernel.org>
2021-01-29 01:00:06 +00:00
|
|
|
static int dsa_switch_change_tag_proto(struct dsa_switch *ds,
|
|
|
|
struct dsa_notifier_tag_proto_info *info)
|
|
|
|
{
|
|
|
|
const struct dsa_device_ops *tag_ops = info->tag_ops;
|
2021-10-20 17:49:50 +00:00
|
|
|
struct dsa_port *dp, *cpu_dp;
|
|
|
|
int err;
|
net: dsa: allow changing the tag protocol via the "tagging" device attribute
Currently DSA exposes the following sysfs:
$ cat /sys/class/net/eno2/dsa/tagging
ocelot
which is a read-only device attribute, introduced in the kernel as
commit 98cdb4807123 ("net: dsa: Expose tagging protocol to user-space"),
and used by libpcap since its commit 993db3800d7d ("Add support for DSA
link-layer types").
It would be nice if we could extend this device attribute by making it
writable:
$ echo ocelot-8021q > /sys/class/net/eno2/dsa/tagging
This is useful with DSA switches that can make use of more than one
tagging protocol. It may be useful in dsa_loop in the future too, to
perform offline testing of various taggers, or for changing between dsa
and edsa on Marvell switches, if that is desirable.
In terms of implementation, drivers can support this feature by
implementing .change_tag_protocol, which should always leave the switch
in a consistent state: either with the new protocol if things went well,
or with the old one if something failed. Teardown of the old protocol,
if necessary, must be handled by the driver.
Some things remain as before:
- The .get_tag_protocol is currently only called at probe time, to load
the initial tagging protocol driver. Nonetheless, new drivers should
report the tagging protocol in current use now.
- The driver should manage by itself the initial setup of tagging
protocol, no later than the .setup() method, as well as destroying
resources used by the last tagger in use, no earlier than the
.teardown() method.
For multi-switch DSA trees, error handling is a bit more complicated,
since e.g. the 5th out of 7 switches may fail to change the tag
protocol. When that happens, a revert to the original tag protocol is
attempted, but that may fail too, leaving the tree in an inconsistent
state despite each individual switch implementing .change_tag_protocol
transactionally. Since the intersection between drivers that implement
.change_tag_protocol and drivers that support D in DSA is currently the
empty set, the possibility for this error to happen is ignored for now.
Testing:
$ insmod mscc_felix.ko
[ 79.549784] mscc_felix 0000:00:00.5: Adding to iommu group 14
[ 79.565712] mscc_felix 0000:00:00.5: Failed to register DSA switch: -517
$ insmod tag_ocelot.ko
$ rmmod mscc_felix.ko
$ insmod mscc_felix.ko
[ 97.261724] libphy: VSC9959 internal MDIO bus: probed
[ 97.267363] mscc_felix 0000:00:00.5: Found PCS at internal MDIO address 0
[ 97.274998] mscc_felix 0000:00:00.5: Found PCS at internal MDIO address 1
[ 97.282561] mscc_felix 0000:00:00.5: Found PCS at internal MDIO address 2
[ 97.289700] mscc_felix 0000:00:00.5: Found PCS at internal MDIO address 3
[ 97.599163] mscc_felix 0000:00:00.5 swp0 (uninitialized): PHY [0000:00:00.3:10] driver [Microsemi GE VSC8514 SyncE] (irq=POLL)
[ 97.862034] mscc_felix 0000:00:00.5 swp1 (uninitialized): PHY [0000:00:00.3:11] driver [Microsemi GE VSC8514 SyncE] (irq=POLL)
[ 97.950731] mscc_felix 0000:00:00.5 swp0: configuring for inband/qsgmii link mode
[ 97.964278] 8021q: adding VLAN 0 to HW filter on device swp0
[ 98.146161] mscc_felix 0000:00:00.5 swp2 (uninitialized): PHY [0000:00:00.3:12] driver [Microsemi GE VSC8514 SyncE] (irq=POLL)
[ 98.238649] mscc_felix 0000:00:00.5 swp1: configuring for inband/qsgmii link mode
[ 98.251845] 8021q: adding VLAN 0 to HW filter on device swp1
[ 98.433916] mscc_felix 0000:00:00.5 swp3 (uninitialized): PHY [0000:00:00.3:13] driver [Microsemi GE VSC8514 SyncE] (irq=POLL)
[ 98.485542] mscc_felix 0000:00:00.5: configuring for fixed/internal link mode
[ 98.503584] mscc_felix 0000:00:00.5: Link is Up - 2.5Gbps/Full - flow control rx/tx
[ 98.527948] device eno2 entered promiscuous mode
[ 98.544755] DSA: tree 0 setup
$ ping 10.0.0.1
PING 10.0.0.1 (10.0.0.1): 56 data bytes
64 bytes from 10.0.0.1: seq=0 ttl=64 time=2.337 ms
64 bytes from 10.0.0.1: seq=1 ttl=64 time=0.754 ms
^C
- 10.0.0.1 ping statistics -
2 packets transmitted, 2 packets received, 0% packet loss
round-trip min/avg/max = 0.754/1.545/2.337 ms
$ cat /sys/class/net/eno2/dsa/tagging
ocelot
$ cat ./test_ocelot_8021q.sh
#!/bin/bash
ip link set swp0 down
ip link set swp1 down
ip link set swp2 down
ip link set swp3 down
ip link set swp5 down
ip link set eno2 down
echo ocelot-8021q > /sys/class/net/eno2/dsa/tagging
ip link set eno2 up
ip link set swp0 up
ip link set swp1 up
ip link set swp2 up
ip link set swp3 up
ip link set swp5 up
$ ./test_ocelot_8021q.sh
./test_ocelot_8021q.sh: line 9: echo: write error: Protocol not available
$ rmmod tag_ocelot.ko
rmmod: can't unload module 'tag_ocelot': Resource temporarily unavailable
$ insmod tag_ocelot_8021q.ko
$ ./test_ocelot_8021q.sh
$ cat /sys/class/net/eno2/dsa/tagging
ocelot-8021q
$ rmmod tag_ocelot.ko
$ rmmod tag_ocelot_8021q.ko
rmmod: can't unload module 'tag_ocelot_8021q': Resource temporarily unavailable
$ ping 10.0.0.1
PING 10.0.0.1 (10.0.0.1): 56 data bytes
64 bytes from 10.0.0.1: seq=0 ttl=64 time=0.953 ms
64 bytes from 10.0.0.1: seq=1 ttl=64 time=0.787 ms
64 bytes from 10.0.0.1: seq=2 ttl=64 time=0.771 ms
$ rmmod mscc_felix.ko
[ 645.544426] mscc_felix 0000:00:00.5: Link is Down
[ 645.838608] DSA: tree 0 torn down
$ rmmod tag_ocelot_8021q.ko
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: Jakub Kicinski <kuba@kernel.org>
2021-01-29 01:00:06 +00:00
|
|
|
|
|
|
|
if (!ds->ops->change_tag_protocol)
|
|
|
|
return -EOPNOTSUPP;
|
|
|
|
|
|
|
|
ASSERT_RTNL();
|
|
|
|
|
2021-10-20 17:49:50 +00:00
|
|
|
dsa_switch_for_each_cpu_port(cpu_dp, ds) {
|
|
|
|
err = ds->ops->change_tag_protocol(ds, cpu_dp->index,
|
|
|
|
tag_ops->proto);
|
2021-04-20 18:53:09 +00:00
|
|
|
if (err)
|
|
|
|
return err;
|
|
|
|
|
2021-10-20 17:49:50 +00:00
|
|
|
dsa_port_set_tag_protocol(cpu_dp, tag_ops);
|
net: dsa: allow changing the tag protocol via the "tagging" device attribute
Currently DSA exposes the following sysfs:
$ cat /sys/class/net/eno2/dsa/tagging
ocelot
which is a read-only device attribute, introduced in the kernel as
commit 98cdb4807123 ("net: dsa: Expose tagging protocol to user-space"),
and used by libpcap since its commit 993db3800d7d ("Add support for DSA
link-layer types").
It would be nice if we could extend this device attribute by making it
writable:
$ echo ocelot-8021q > /sys/class/net/eno2/dsa/tagging
This is useful with DSA switches that can make use of more than one
tagging protocol. It may be useful in dsa_loop in the future too, to
perform offline testing of various taggers, or for changing between dsa
and edsa on Marvell switches, if that is desirable.
In terms of implementation, drivers can support this feature by
implementing .change_tag_protocol, which should always leave the switch
in a consistent state: either with the new protocol if things went well,
or with the old one if something failed. Teardown of the old protocol,
if necessary, must be handled by the driver.
Some things remain as before:
- The .get_tag_protocol is currently only called at probe time, to load
the initial tagging protocol driver. Nonetheless, new drivers should
report the tagging protocol in current use now.
- The driver should manage by itself the initial setup of tagging
protocol, no later than the .setup() method, as well as destroying
resources used by the last tagger in use, no earlier than the
.teardown() method.
For multi-switch DSA trees, error handling is a bit more complicated,
since e.g. the 5th out of 7 switches may fail to change the tag
protocol. When that happens, a revert to the original tag protocol is
attempted, but that may fail too, leaving the tree in an inconsistent
state despite each individual switch implementing .change_tag_protocol
transactionally. Since the intersection between drivers that implement
.change_tag_protocol and drivers that support D in DSA is currently the
empty set, the possibility for this error to happen is ignored for now.
Testing:
$ insmod mscc_felix.ko
[ 79.549784] mscc_felix 0000:00:00.5: Adding to iommu group 14
[ 79.565712] mscc_felix 0000:00:00.5: Failed to register DSA switch: -517
$ insmod tag_ocelot.ko
$ rmmod mscc_felix.ko
$ insmod mscc_felix.ko
[ 97.261724] libphy: VSC9959 internal MDIO bus: probed
[ 97.267363] mscc_felix 0000:00:00.5: Found PCS at internal MDIO address 0
[ 97.274998] mscc_felix 0000:00:00.5: Found PCS at internal MDIO address 1
[ 97.282561] mscc_felix 0000:00:00.5: Found PCS at internal MDIO address 2
[ 97.289700] mscc_felix 0000:00:00.5: Found PCS at internal MDIO address 3
[ 97.599163] mscc_felix 0000:00:00.5 swp0 (uninitialized): PHY [0000:00:00.3:10] driver [Microsemi GE VSC8514 SyncE] (irq=POLL)
[ 97.862034] mscc_felix 0000:00:00.5 swp1 (uninitialized): PHY [0000:00:00.3:11] driver [Microsemi GE VSC8514 SyncE] (irq=POLL)
[ 97.950731] mscc_felix 0000:00:00.5 swp0: configuring for inband/qsgmii link mode
[ 97.964278] 8021q: adding VLAN 0 to HW filter on device swp0
[ 98.146161] mscc_felix 0000:00:00.5 swp2 (uninitialized): PHY [0000:00:00.3:12] driver [Microsemi GE VSC8514 SyncE] (irq=POLL)
[ 98.238649] mscc_felix 0000:00:00.5 swp1: configuring for inband/qsgmii link mode
[ 98.251845] 8021q: adding VLAN 0 to HW filter on device swp1
[ 98.433916] mscc_felix 0000:00:00.5 swp3 (uninitialized): PHY [0000:00:00.3:13] driver [Microsemi GE VSC8514 SyncE] (irq=POLL)
[ 98.485542] mscc_felix 0000:00:00.5: configuring for fixed/internal link mode
[ 98.503584] mscc_felix 0000:00:00.5: Link is Up - 2.5Gbps/Full - flow control rx/tx
[ 98.527948] device eno2 entered promiscuous mode
[ 98.544755] DSA: tree 0 setup
$ ping 10.0.0.1
PING 10.0.0.1 (10.0.0.1): 56 data bytes
64 bytes from 10.0.0.1: seq=0 ttl=64 time=2.337 ms
64 bytes from 10.0.0.1: seq=1 ttl=64 time=0.754 ms
^C
- 10.0.0.1 ping statistics -
2 packets transmitted, 2 packets received, 0% packet loss
round-trip min/avg/max = 0.754/1.545/2.337 ms
$ cat /sys/class/net/eno2/dsa/tagging
ocelot
$ cat ./test_ocelot_8021q.sh
#!/bin/bash
ip link set swp0 down
ip link set swp1 down
ip link set swp2 down
ip link set swp3 down
ip link set swp5 down
ip link set eno2 down
echo ocelot-8021q > /sys/class/net/eno2/dsa/tagging
ip link set eno2 up
ip link set swp0 up
ip link set swp1 up
ip link set swp2 up
ip link set swp3 up
ip link set swp5 up
$ ./test_ocelot_8021q.sh
./test_ocelot_8021q.sh: line 9: echo: write error: Protocol not available
$ rmmod tag_ocelot.ko
rmmod: can't unload module 'tag_ocelot': Resource temporarily unavailable
$ insmod tag_ocelot_8021q.ko
$ ./test_ocelot_8021q.sh
$ cat /sys/class/net/eno2/dsa/tagging
ocelot-8021q
$ rmmod tag_ocelot.ko
$ rmmod tag_ocelot_8021q.ko
rmmod: can't unload module 'tag_ocelot_8021q': Resource temporarily unavailable
$ ping 10.0.0.1
PING 10.0.0.1 (10.0.0.1): 56 data bytes
64 bytes from 10.0.0.1: seq=0 ttl=64 time=0.953 ms
64 bytes from 10.0.0.1: seq=1 ttl=64 time=0.787 ms
64 bytes from 10.0.0.1: seq=2 ttl=64 time=0.771 ms
$ rmmod mscc_felix.ko
[ 645.544426] mscc_felix 0000:00:00.5: Link is Down
[ 645.838608] DSA: tree 0 torn down
$ rmmod tag_ocelot_8021q.ko
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: Jakub Kicinski <kuba@kernel.org>
2021-01-29 01:00:06 +00:00
|
|
|
}
|
|
|
|
|
|
|
|
/* Now that changing the tag protocol can no longer fail, let's update
|
|
|
|
* the remaining bits which are "duplicated for faster access", and the
|
|
|
|
* bits that depend on the tagger, such as the MTU.
|
|
|
|
*/
|
2021-10-20 17:49:50 +00:00
|
|
|
dsa_switch_for_each_user_port(dp, ds) {
|
|
|
|
struct net_device *slave = dp->slave;
|
net: dsa: allow changing the tag protocol via the "tagging" device attribute
Currently DSA exposes the following sysfs:
$ cat /sys/class/net/eno2/dsa/tagging
ocelot
which is a read-only device attribute, introduced in the kernel as
commit 98cdb4807123 ("net: dsa: Expose tagging protocol to user-space"),
and used by libpcap since its commit 993db3800d7d ("Add support for DSA
link-layer types").
It would be nice if we could extend this device attribute by making it
writable:
$ echo ocelot-8021q > /sys/class/net/eno2/dsa/tagging
This is useful with DSA switches that can make use of more than one
tagging protocol. It may be useful in dsa_loop in the future too, to
perform offline testing of various taggers, or for changing between dsa
and edsa on Marvell switches, if that is desirable.
In terms of implementation, drivers can support this feature by
implementing .change_tag_protocol, which should always leave the switch
in a consistent state: either with the new protocol if things went well,
or with the old one if something failed. Teardown of the old protocol,
if necessary, must be handled by the driver.
Some things remain as before:
- The .get_tag_protocol is currently only called at probe time, to load
the initial tagging protocol driver. Nonetheless, new drivers should
report the tagging protocol in current use now.
- The driver should manage by itself the initial setup of tagging
protocol, no later than the .setup() method, as well as destroying
resources used by the last tagger in use, no earlier than the
.teardown() method.
For multi-switch DSA trees, error handling is a bit more complicated,
since e.g. the 5th out of 7 switches may fail to change the tag
protocol. When that happens, a revert to the original tag protocol is
attempted, but that may fail too, leaving the tree in an inconsistent
state despite each individual switch implementing .change_tag_protocol
transactionally. Since the intersection between drivers that implement
.change_tag_protocol and drivers that support D in DSA is currently the
empty set, the possibility for this error to happen is ignored for now.
Testing:
$ insmod mscc_felix.ko
[ 79.549784] mscc_felix 0000:00:00.5: Adding to iommu group 14
[ 79.565712] mscc_felix 0000:00:00.5: Failed to register DSA switch: -517
$ insmod tag_ocelot.ko
$ rmmod mscc_felix.ko
$ insmod mscc_felix.ko
[ 97.261724] libphy: VSC9959 internal MDIO bus: probed
[ 97.267363] mscc_felix 0000:00:00.5: Found PCS at internal MDIO address 0
[ 97.274998] mscc_felix 0000:00:00.5: Found PCS at internal MDIO address 1
[ 97.282561] mscc_felix 0000:00:00.5: Found PCS at internal MDIO address 2
[ 97.289700] mscc_felix 0000:00:00.5: Found PCS at internal MDIO address 3
[ 97.599163] mscc_felix 0000:00:00.5 swp0 (uninitialized): PHY [0000:00:00.3:10] driver [Microsemi GE VSC8514 SyncE] (irq=POLL)
[ 97.862034] mscc_felix 0000:00:00.5 swp1 (uninitialized): PHY [0000:00:00.3:11] driver [Microsemi GE VSC8514 SyncE] (irq=POLL)
[ 97.950731] mscc_felix 0000:00:00.5 swp0: configuring for inband/qsgmii link mode
[ 97.964278] 8021q: adding VLAN 0 to HW filter on device swp0
[ 98.146161] mscc_felix 0000:00:00.5 swp2 (uninitialized): PHY [0000:00:00.3:12] driver [Microsemi GE VSC8514 SyncE] (irq=POLL)
[ 98.238649] mscc_felix 0000:00:00.5 swp1: configuring for inband/qsgmii link mode
[ 98.251845] 8021q: adding VLAN 0 to HW filter on device swp1
[ 98.433916] mscc_felix 0000:00:00.5 swp3 (uninitialized): PHY [0000:00:00.3:13] driver [Microsemi GE VSC8514 SyncE] (irq=POLL)
[ 98.485542] mscc_felix 0000:00:00.5: configuring for fixed/internal link mode
[ 98.503584] mscc_felix 0000:00:00.5: Link is Up - 2.5Gbps/Full - flow control rx/tx
[ 98.527948] device eno2 entered promiscuous mode
[ 98.544755] DSA: tree 0 setup
$ ping 10.0.0.1
PING 10.0.0.1 (10.0.0.1): 56 data bytes
64 bytes from 10.0.0.1: seq=0 ttl=64 time=2.337 ms
64 bytes from 10.0.0.1: seq=1 ttl=64 time=0.754 ms
^C
- 10.0.0.1 ping statistics -
2 packets transmitted, 2 packets received, 0% packet loss
round-trip min/avg/max = 0.754/1.545/2.337 ms
$ cat /sys/class/net/eno2/dsa/tagging
ocelot
$ cat ./test_ocelot_8021q.sh
#!/bin/bash
ip link set swp0 down
ip link set swp1 down
ip link set swp2 down
ip link set swp3 down
ip link set swp5 down
ip link set eno2 down
echo ocelot-8021q > /sys/class/net/eno2/dsa/tagging
ip link set eno2 up
ip link set swp0 up
ip link set swp1 up
ip link set swp2 up
ip link set swp3 up
ip link set swp5 up
$ ./test_ocelot_8021q.sh
./test_ocelot_8021q.sh: line 9: echo: write error: Protocol not available
$ rmmod tag_ocelot.ko
rmmod: can't unload module 'tag_ocelot': Resource temporarily unavailable
$ insmod tag_ocelot_8021q.ko
$ ./test_ocelot_8021q.sh
$ cat /sys/class/net/eno2/dsa/tagging
ocelot-8021q
$ rmmod tag_ocelot.ko
$ rmmod tag_ocelot_8021q.ko
rmmod: can't unload module 'tag_ocelot_8021q': Resource temporarily unavailable
$ ping 10.0.0.1
PING 10.0.0.1 (10.0.0.1): 56 data bytes
64 bytes from 10.0.0.1: seq=0 ttl=64 time=0.953 ms
64 bytes from 10.0.0.1: seq=1 ttl=64 time=0.787 ms
64 bytes from 10.0.0.1: seq=2 ttl=64 time=0.771 ms
$ rmmod mscc_felix.ko
[ 645.544426] mscc_felix 0000:00:00.5: Link is Down
[ 645.838608] DSA: tree 0 torn down
$ rmmod tag_ocelot_8021q.ko
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: Jakub Kicinski <kuba@kernel.org>
2021-01-29 01:00:06 +00:00
|
|
|
|
2021-10-20 17:49:50 +00:00
|
|
|
dsa_slave_setup_tagger(slave);
|
net: dsa: allow changing the tag protocol via the "tagging" device attribute
Currently DSA exposes the following sysfs:
$ cat /sys/class/net/eno2/dsa/tagging
ocelot
which is a read-only device attribute, introduced in the kernel as
commit 98cdb4807123 ("net: dsa: Expose tagging protocol to user-space"),
and used by libpcap since its commit 993db3800d7d ("Add support for DSA
link-layer types").
It would be nice if we could extend this device attribute by making it
writable:
$ echo ocelot-8021q > /sys/class/net/eno2/dsa/tagging
This is useful with DSA switches that can make use of more than one
tagging protocol. It may be useful in dsa_loop in the future too, to
perform offline testing of various taggers, or for changing between dsa
and edsa on Marvell switches, if that is desirable.
In terms of implementation, drivers can support this feature by
implementing .change_tag_protocol, which should always leave the switch
in a consistent state: either with the new protocol if things went well,
or with the old one if something failed. Teardown of the old protocol,
if necessary, must be handled by the driver.
Some things remain as before:
- The .get_tag_protocol is currently only called at probe time, to load
the initial tagging protocol driver. Nonetheless, new drivers should
report the tagging protocol in current use now.
- The driver should manage by itself the initial setup of tagging
protocol, no later than the .setup() method, as well as destroying
resources used by the last tagger in use, no earlier than the
.teardown() method.
For multi-switch DSA trees, error handling is a bit more complicated,
since e.g. the 5th out of 7 switches may fail to change the tag
protocol. When that happens, a revert to the original tag protocol is
attempted, but that may fail too, leaving the tree in an inconsistent
state despite each individual switch implementing .change_tag_protocol
transactionally. Since the intersection between drivers that implement
.change_tag_protocol and drivers that support D in DSA is currently the
empty set, the possibility for this error to happen is ignored for now.
Testing:
$ insmod mscc_felix.ko
[ 79.549784] mscc_felix 0000:00:00.5: Adding to iommu group 14
[ 79.565712] mscc_felix 0000:00:00.5: Failed to register DSA switch: -517
$ insmod tag_ocelot.ko
$ rmmod mscc_felix.ko
$ insmod mscc_felix.ko
[ 97.261724] libphy: VSC9959 internal MDIO bus: probed
[ 97.267363] mscc_felix 0000:00:00.5: Found PCS at internal MDIO address 0
[ 97.274998] mscc_felix 0000:00:00.5: Found PCS at internal MDIO address 1
[ 97.282561] mscc_felix 0000:00:00.5: Found PCS at internal MDIO address 2
[ 97.289700] mscc_felix 0000:00:00.5: Found PCS at internal MDIO address 3
[ 97.599163] mscc_felix 0000:00:00.5 swp0 (uninitialized): PHY [0000:00:00.3:10] driver [Microsemi GE VSC8514 SyncE] (irq=POLL)
[ 97.862034] mscc_felix 0000:00:00.5 swp1 (uninitialized): PHY [0000:00:00.3:11] driver [Microsemi GE VSC8514 SyncE] (irq=POLL)
[ 97.950731] mscc_felix 0000:00:00.5 swp0: configuring for inband/qsgmii link mode
[ 97.964278] 8021q: adding VLAN 0 to HW filter on device swp0
[ 98.146161] mscc_felix 0000:00:00.5 swp2 (uninitialized): PHY [0000:00:00.3:12] driver [Microsemi GE VSC8514 SyncE] (irq=POLL)
[ 98.238649] mscc_felix 0000:00:00.5 swp1: configuring for inband/qsgmii link mode
[ 98.251845] 8021q: adding VLAN 0 to HW filter on device swp1
[ 98.433916] mscc_felix 0000:00:00.5 swp3 (uninitialized): PHY [0000:00:00.3:13] driver [Microsemi GE VSC8514 SyncE] (irq=POLL)
[ 98.485542] mscc_felix 0000:00:00.5: configuring for fixed/internal link mode
[ 98.503584] mscc_felix 0000:00:00.5: Link is Up - 2.5Gbps/Full - flow control rx/tx
[ 98.527948] device eno2 entered promiscuous mode
[ 98.544755] DSA: tree 0 setup
$ ping 10.0.0.1
PING 10.0.0.1 (10.0.0.1): 56 data bytes
64 bytes from 10.0.0.1: seq=0 ttl=64 time=2.337 ms
64 bytes from 10.0.0.1: seq=1 ttl=64 time=0.754 ms
^C
- 10.0.0.1 ping statistics -
2 packets transmitted, 2 packets received, 0% packet loss
round-trip min/avg/max = 0.754/1.545/2.337 ms
$ cat /sys/class/net/eno2/dsa/tagging
ocelot
$ cat ./test_ocelot_8021q.sh
#!/bin/bash
ip link set swp0 down
ip link set swp1 down
ip link set swp2 down
ip link set swp3 down
ip link set swp5 down
ip link set eno2 down
echo ocelot-8021q > /sys/class/net/eno2/dsa/tagging
ip link set eno2 up
ip link set swp0 up
ip link set swp1 up
ip link set swp2 up
ip link set swp3 up
ip link set swp5 up
$ ./test_ocelot_8021q.sh
./test_ocelot_8021q.sh: line 9: echo: write error: Protocol not available
$ rmmod tag_ocelot.ko
rmmod: can't unload module 'tag_ocelot': Resource temporarily unavailable
$ insmod tag_ocelot_8021q.ko
$ ./test_ocelot_8021q.sh
$ cat /sys/class/net/eno2/dsa/tagging
ocelot-8021q
$ rmmod tag_ocelot.ko
$ rmmod tag_ocelot_8021q.ko
rmmod: can't unload module 'tag_ocelot_8021q': Resource temporarily unavailable
$ ping 10.0.0.1
PING 10.0.0.1 (10.0.0.1): 56 data bytes
64 bytes from 10.0.0.1: seq=0 ttl=64 time=0.953 ms
64 bytes from 10.0.0.1: seq=1 ttl=64 time=0.787 ms
64 bytes from 10.0.0.1: seq=2 ttl=64 time=0.771 ms
$ rmmod mscc_felix.ko
[ 645.544426] mscc_felix 0000:00:00.5: Link is Down
[ 645.838608] DSA: tree 0 torn down
$ rmmod tag_ocelot_8021q.ko
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: Jakub Kicinski <kuba@kernel.org>
2021-01-29 01:00:06 +00:00
|
|
|
|
2021-10-20 17:49:50 +00:00
|
|
|
/* rtnl_mutex is held in dsa_tree_change_tag_proto */
|
|
|
|
dsa_slave_change_mtu(slave, slave->mtu);
|
net: dsa: allow changing the tag protocol via the "tagging" device attribute
Currently DSA exposes the following sysfs:
$ cat /sys/class/net/eno2/dsa/tagging
ocelot
which is a read-only device attribute, introduced in the kernel as
commit 98cdb4807123 ("net: dsa: Expose tagging protocol to user-space"),
and used by libpcap since its commit 993db3800d7d ("Add support for DSA
link-layer types").
It would be nice if we could extend this device attribute by making it
writable:
$ echo ocelot-8021q > /sys/class/net/eno2/dsa/tagging
This is useful with DSA switches that can make use of more than one
tagging protocol. It may be useful in dsa_loop in the future too, to
perform offline testing of various taggers, or for changing between dsa
and edsa on Marvell switches, if that is desirable.
In terms of implementation, drivers can support this feature by
implementing .change_tag_protocol, which should always leave the switch
in a consistent state: either with the new protocol if things went well,
or with the old one if something failed. Teardown of the old protocol,
if necessary, must be handled by the driver.
Some things remain as before:
- The .get_tag_protocol is currently only called at probe time, to load
the initial tagging protocol driver. Nonetheless, new drivers should
report the tagging protocol in current use now.
- The driver should manage by itself the initial setup of tagging
protocol, no later than the .setup() method, as well as destroying
resources used by the last tagger in use, no earlier than the
.teardown() method.
For multi-switch DSA trees, error handling is a bit more complicated,
since e.g. the 5th out of 7 switches may fail to change the tag
protocol. When that happens, a revert to the original tag protocol is
attempted, but that may fail too, leaving the tree in an inconsistent
state despite each individual switch implementing .change_tag_protocol
transactionally. Since the intersection between drivers that implement
.change_tag_protocol and drivers that support D in DSA is currently the
empty set, the possibility for this error to happen is ignored for now.
Testing:
$ insmod mscc_felix.ko
[ 79.549784] mscc_felix 0000:00:00.5: Adding to iommu group 14
[ 79.565712] mscc_felix 0000:00:00.5: Failed to register DSA switch: -517
$ insmod tag_ocelot.ko
$ rmmod mscc_felix.ko
$ insmod mscc_felix.ko
[ 97.261724] libphy: VSC9959 internal MDIO bus: probed
[ 97.267363] mscc_felix 0000:00:00.5: Found PCS at internal MDIO address 0
[ 97.274998] mscc_felix 0000:00:00.5: Found PCS at internal MDIO address 1
[ 97.282561] mscc_felix 0000:00:00.5: Found PCS at internal MDIO address 2
[ 97.289700] mscc_felix 0000:00:00.5: Found PCS at internal MDIO address 3
[ 97.599163] mscc_felix 0000:00:00.5 swp0 (uninitialized): PHY [0000:00:00.3:10] driver [Microsemi GE VSC8514 SyncE] (irq=POLL)
[ 97.862034] mscc_felix 0000:00:00.5 swp1 (uninitialized): PHY [0000:00:00.3:11] driver [Microsemi GE VSC8514 SyncE] (irq=POLL)
[ 97.950731] mscc_felix 0000:00:00.5 swp0: configuring for inband/qsgmii link mode
[ 97.964278] 8021q: adding VLAN 0 to HW filter on device swp0
[ 98.146161] mscc_felix 0000:00:00.5 swp2 (uninitialized): PHY [0000:00:00.3:12] driver [Microsemi GE VSC8514 SyncE] (irq=POLL)
[ 98.238649] mscc_felix 0000:00:00.5 swp1: configuring for inband/qsgmii link mode
[ 98.251845] 8021q: adding VLAN 0 to HW filter on device swp1
[ 98.433916] mscc_felix 0000:00:00.5 swp3 (uninitialized): PHY [0000:00:00.3:13] driver [Microsemi GE VSC8514 SyncE] (irq=POLL)
[ 98.485542] mscc_felix 0000:00:00.5: configuring for fixed/internal link mode
[ 98.503584] mscc_felix 0000:00:00.5: Link is Up - 2.5Gbps/Full - flow control rx/tx
[ 98.527948] device eno2 entered promiscuous mode
[ 98.544755] DSA: tree 0 setup
$ ping 10.0.0.1
PING 10.0.0.1 (10.0.0.1): 56 data bytes
64 bytes from 10.0.0.1: seq=0 ttl=64 time=2.337 ms
64 bytes from 10.0.0.1: seq=1 ttl=64 time=0.754 ms
^C
- 10.0.0.1 ping statistics -
2 packets transmitted, 2 packets received, 0% packet loss
round-trip min/avg/max = 0.754/1.545/2.337 ms
$ cat /sys/class/net/eno2/dsa/tagging
ocelot
$ cat ./test_ocelot_8021q.sh
#!/bin/bash
ip link set swp0 down
ip link set swp1 down
ip link set swp2 down
ip link set swp3 down
ip link set swp5 down
ip link set eno2 down
echo ocelot-8021q > /sys/class/net/eno2/dsa/tagging
ip link set eno2 up
ip link set swp0 up
ip link set swp1 up
ip link set swp2 up
ip link set swp3 up
ip link set swp5 up
$ ./test_ocelot_8021q.sh
./test_ocelot_8021q.sh: line 9: echo: write error: Protocol not available
$ rmmod tag_ocelot.ko
rmmod: can't unload module 'tag_ocelot': Resource temporarily unavailable
$ insmod tag_ocelot_8021q.ko
$ ./test_ocelot_8021q.sh
$ cat /sys/class/net/eno2/dsa/tagging
ocelot-8021q
$ rmmod tag_ocelot.ko
$ rmmod tag_ocelot_8021q.ko
rmmod: can't unload module 'tag_ocelot_8021q': Resource temporarily unavailable
$ ping 10.0.0.1
PING 10.0.0.1 (10.0.0.1): 56 data bytes
64 bytes from 10.0.0.1: seq=0 ttl=64 time=0.953 ms
64 bytes from 10.0.0.1: seq=1 ttl=64 time=0.787 ms
64 bytes from 10.0.0.1: seq=2 ttl=64 time=0.771 ms
$ rmmod mscc_felix.ko
[ 645.544426] mscc_felix 0000:00:00.5: Link is Down
[ 645.838608] DSA: tree 0 torn down
$ rmmod tag_ocelot_8021q.ko
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: Jakub Kicinski <kuba@kernel.org>
2021-01-29 01:00:06 +00:00
|
|
|
}
|
|
|
|
|
|
|
|
return 0;
|
|
|
|
}
|
|
|
|
|
net: dsa: make tagging protocols connect to individual switches from a tree
On the NXP Bluebox 3 board which uses a multi-switch setup with sja1105,
the mechanism through which the tagger connects to the switch tree is
broken, due to improper DSA code design. At the time when tag_ops->connect()
is called in dsa_port_parse_cpu(), DSA hasn't finished "touching" all
the ports, so it doesn't know how large the tree is and how many ports
it has. It has just seen the first CPU port by this time. As a result,
this function will call the tagger's ->connect method too early, and the
tagger will connect only to the first switch from the tree.
This could be perhaps addressed a bit more simply by just moving the
tag_ops->connect(dst) call a bit later (for example in dsa_tree_setup),
but there is already a design inconsistency at present: on the switch
side, the notification is on a per-switch basis, but on the tagger side,
it is on a per-tree basis. Furthermore, the persistent storage itself is
per switch (ds->tagger_data). And the tagger connect and disconnect
procedures (at least the ones that exist currently) could see a fair bit
of simplification if they didn't have to iterate through the switches of
a tree.
To fix the issue, this change transforms tag_ops->connect(dst) into
tag_ops->connect(ds) and moves it somewhere where we already iterate
over all switches of a tree. That is in dsa_switch_setup_tag_protocol(),
which is a good placement because we already have there the connection
call to the switch side of things.
As for the dsa_tree_bind_tag_proto() method (called from the code path
that changes the tag protocol), things are a bit more complicated
because we receive the tree as argument, yet when we unwind on errors,
it would be nice to not call tag_ops->disconnect(ds) where we didn't
previously call tag_ops->connect(ds). We didn't have this problem before
because the tag_ops connection operations passed the entire dst before,
and this is more fine grained now. To solve the error rewind case using
the new API, we have to create yet one more cross-chip notifier for
disconnection, and stay connected with the old tag protocol to all the
switches in the tree until we've succeeded to connect with the new one
as well. So if something fails half way, the whole tree is still
connected to the old tagger. But there may still be leaks if the tagger
fails to connect to the 2nd out of 3 switches in a tree: somebody needs
to tell the tagger to disconnect from the first switch. Nothing comes
for free, and this was previously handled privately by the tagging
protocol driver before, but now we need to emit a disconnect cross-chip
notifier for that, because DSA has to take care of the unwind path. We
assume that the tagging protocol has connected to a switch if it has set
ds->tagger_data to something, otherwise we avoid calling its
disconnection method in the error rewind path.
The rest of the changes are in the tagging protocol drivers, and have to
do with the replacement of dst with ds. The iteration is removed and the
error unwind path is simplified, as mentioned above.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-12-14 01:45:36 +00:00
|
|
|
/* We use the same cross-chip notifiers to inform both the tagger side, as well
|
|
|
|
* as the switch side, of connection and disconnection events.
|
|
|
|
* Since ds->tagger_data is owned by the tagger, it isn't a hard error if the
|
|
|
|
* switch side doesn't support connecting to this tagger, and therefore, the
|
|
|
|
* fact that we don't disconnect the tagger side doesn't constitute a memory
|
|
|
|
* leak: the tagger will still operate with persistent per-switch memory, just
|
|
|
|
* with the switch side unconnected to it. What does constitute a hard error is
|
|
|
|
* when the switch side supports connecting but fails.
|
|
|
|
*/
|
|
|
|
static int
|
|
|
|
dsa_switch_connect_tag_proto(struct dsa_switch *ds,
|
|
|
|
struct dsa_notifier_tag_proto_info *info)
|
net: dsa: introduce tagger-owned storage for private and shared data
Ansuel is working on register access over Ethernet for the qca8k switch
family. This requires the qca8k tagging protocol driver to receive
frames which aren't intended for the network stack, but instead for the
qca8k switch driver itself.
The dp->priv is currently the prevailing method for passing data back
and forth between the tagging protocol driver and the switch driver.
However, this method is riddled with caveats.
The DSA design allows in principle for any switch driver to return any
protocol it desires in ->get_tag_protocol(). The dsa_loop driver can be
modified to do just that. But in the current design, the memory behind
dp->priv has to be allocated by the switch driver, so if the tagging
protocol is paired to an unexpected switch driver, we may end up in NULL
pointer dereferences inside the kernel, or worse (a switch driver may
allocate dp->priv according to the expectations of a different tagger).
The latter possibility is even more plausible considering that DSA
switches can dynamically change tagging protocols in certain cases
(dsa <-> edsa, ocelot <-> ocelot-8021q), and the current design lends
itself to mistakes that are all too easy to make.
This patch proposes that the tagging protocol driver should manage its
own memory, instead of relying on the switch driver to do so.
After analyzing the different in-tree needs, it can be observed that the
required tagger storage is per switch, therefore a ds->tagger_data
pointer is introduced. In principle, per-port storage could also be
introduced, although there is no need for it at the moment. Future
changes will replace the current usage of dp->priv with ds->tagger_data.
We define a "binding" event between the DSA switch tree and the tagging
protocol. During this binding event, the tagging protocol's ->connect()
method is called first, and this may allocate some memory for each
switch of the tree. Then a cross-chip notifier is emitted for the
switches within that tree, and they are given the opportunity to fix up
the tagger's memory (for example, they might set up some function
pointers that represent virtual methods for consuming packets).
Because the memory is owned by the tagger, there exists a ->disconnect()
method for the tagger (which is the place to free the resources), but
there doesn't exist a ->disconnect() method for the switch driver.
This is part of the design. The switch driver should make minimal use of
the public part of the tagger data, and only after type-checking it
using the supplied "proto" argument.
In the code there are in fact two binding events, one is the initial
event in dsa_switch_setup_tag_protocol(). At this stage, the cross chip
notifier chains aren't initialized, so we call each switch's connect()
method by hand. Then there is dsa_tree_bind_tag_proto() during
dsa_tree_change_tag_proto(), and here we have an old protocol and a new
one. We first connect to the new one before disconnecting from the old
one, to simplify error handling a bit and to ensure we remain in a valid
state at all times.
Co-developed-by: Ansuel Smith <ansuelsmth@gmail.com>
Signed-off-by: Ansuel Smith <ansuelsmth@gmail.com>
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-12-09 23:34:37 +00:00
|
|
|
{
|
|
|
|
const struct dsa_device_ops *tag_ops = info->tag_ops;
|
net: dsa: make tagging protocols connect to individual switches from a tree
On the NXP Bluebox 3 board which uses a multi-switch setup with sja1105,
the mechanism through which the tagger connects to the switch tree is
broken, due to improper DSA code design. At the time when tag_ops->connect()
is called in dsa_port_parse_cpu(), DSA hasn't finished "touching" all
the ports, so it doesn't know how large the tree is and how many ports
it has. It has just seen the first CPU port by this time. As a result,
this function will call the tagger's ->connect method too early, and the
tagger will connect only to the first switch from the tree.
This could be perhaps addressed a bit more simply by just moving the
tag_ops->connect(dst) call a bit later (for example in dsa_tree_setup),
but there is already a design inconsistency at present: on the switch
side, the notification is on a per-switch basis, but on the tagger side,
it is on a per-tree basis. Furthermore, the persistent storage itself is
per switch (ds->tagger_data). And the tagger connect and disconnect
procedures (at least the ones that exist currently) could see a fair bit
of simplification if they didn't have to iterate through the switches of
a tree.
To fix the issue, this change transforms tag_ops->connect(dst) into
tag_ops->connect(ds) and moves it somewhere where we already iterate
over all switches of a tree. That is in dsa_switch_setup_tag_protocol(),
which is a good placement because we already have there the connection
call to the switch side of things.
As for the dsa_tree_bind_tag_proto() method (called from the code path
that changes the tag protocol), things are a bit more complicated
because we receive the tree as argument, yet when we unwind on errors,
it would be nice to not call tag_ops->disconnect(ds) where we didn't
previously call tag_ops->connect(ds). We didn't have this problem before
because the tag_ops connection operations passed the entire dst before,
and this is more fine grained now. To solve the error rewind case using
the new API, we have to create yet one more cross-chip notifier for
disconnection, and stay connected with the old tag protocol to all the
switches in the tree until we've succeeded to connect with the new one
as well. So if something fails half way, the whole tree is still
connected to the old tagger. But there may still be leaks if the tagger
fails to connect to the 2nd out of 3 switches in a tree: somebody needs
to tell the tagger to disconnect from the first switch. Nothing comes
for free, and this was previously handled privately by the tagging
protocol driver before, but now we need to emit a disconnect cross-chip
notifier for that, because DSA has to take care of the unwind path. We
assume that the tagging protocol has connected to a switch if it has set
ds->tagger_data to something, otherwise we avoid calling its
disconnection method in the error rewind path.
The rest of the changes are in the tagging protocol drivers, and have to
do with the replacement of dst with ds. The iteration is removed and the
error unwind path is simplified, as mentioned above.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-12-14 01:45:36 +00:00
|
|
|
int err;
|
|
|
|
|
|
|
|
/* Notify the new tagger about the connection to this switch */
|
|
|
|
if (tag_ops->connect) {
|
|
|
|
err = tag_ops->connect(ds);
|
|
|
|
if (err)
|
|
|
|
return err;
|
|
|
|
}
|
net: dsa: introduce tagger-owned storage for private and shared data
Ansuel is working on register access over Ethernet for the qca8k switch
family. This requires the qca8k tagging protocol driver to receive
frames which aren't intended for the network stack, but instead for the
qca8k switch driver itself.
The dp->priv is currently the prevailing method for passing data back
and forth between the tagging protocol driver and the switch driver.
However, this method is riddled with caveats.
The DSA design allows in principle for any switch driver to return any
protocol it desires in ->get_tag_protocol(). The dsa_loop driver can be
modified to do just that. But in the current design, the memory behind
dp->priv has to be allocated by the switch driver, so if the tagging
protocol is paired to an unexpected switch driver, we may end up in NULL
pointer dereferences inside the kernel, or worse (a switch driver may
allocate dp->priv according to the expectations of a different tagger).
The latter possibility is even more plausible considering that DSA
switches can dynamically change tagging protocols in certain cases
(dsa <-> edsa, ocelot <-> ocelot-8021q), and the current design lends
itself to mistakes that are all too easy to make.
This patch proposes that the tagging protocol driver should manage its
own memory, instead of relying on the switch driver to do so.
After analyzing the different in-tree needs, it can be observed that the
required tagger storage is per switch, therefore a ds->tagger_data
pointer is introduced. In principle, per-port storage could also be
introduced, although there is no need for it at the moment. Future
changes will replace the current usage of dp->priv with ds->tagger_data.
We define a "binding" event between the DSA switch tree and the tagging
protocol. During this binding event, the tagging protocol's ->connect()
method is called first, and this may allocate some memory for each
switch of the tree. Then a cross-chip notifier is emitted for the
switches within that tree, and they are given the opportunity to fix up
the tagger's memory (for example, they might set up some function
pointers that represent virtual methods for consuming packets).
Because the memory is owned by the tagger, there exists a ->disconnect()
method for the tagger (which is the place to free the resources), but
there doesn't exist a ->disconnect() method for the switch driver.
This is part of the design. The switch driver should make minimal use of
the public part of the tagger data, and only after type-checking it
using the supplied "proto" argument.
In the code there are in fact two binding events, one is the initial
event in dsa_switch_setup_tag_protocol(). At this stage, the cross chip
notifier chains aren't initialized, so we call each switch's connect()
method by hand. Then there is dsa_tree_bind_tag_proto() during
dsa_tree_change_tag_proto(), and here we have an old protocol and a new
one. We first connect to the new one before disconnecting from the old
one, to simplify error handling a bit and to ensure we remain in a valid
state at all times.
Co-developed-by: Ansuel Smith <ansuelsmth@gmail.com>
Signed-off-by: Ansuel Smith <ansuelsmth@gmail.com>
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-12-09 23:34:37 +00:00
|
|
|
|
|
|
|
if (!ds->ops->connect_tag_protocol)
|
|
|
|
return -EOPNOTSUPP;
|
|
|
|
|
net: dsa: make tagging protocols connect to individual switches from a tree
On the NXP Bluebox 3 board which uses a multi-switch setup with sja1105,
the mechanism through which the tagger connects to the switch tree is
broken, due to improper DSA code design. At the time when tag_ops->connect()
is called in dsa_port_parse_cpu(), DSA hasn't finished "touching" all
the ports, so it doesn't know how large the tree is and how many ports
it has. It has just seen the first CPU port by this time. As a result,
this function will call the tagger's ->connect method too early, and the
tagger will connect only to the first switch from the tree.
This could be perhaps addressed a bit more simply by just moving the
tag_ops->connect(dst) call a bit later (for example in dsa_tree_setup),
but there is already a design inconsistency at present: on the switch
side, the notification is on a per-switch basis, but on the tagger side,
it is on a per-tree basis. Furthermore, the persistent storage itself is
per switch (ds->tagger_data). And the tagger connect and disconnect
procedures (at least the ones that exist currently) could see a fair bit
of simplification if they didn't have to iterate through the switches of
a tree.
To fix the issue, this change transforms tag_ops->connect(dst) into
tag_ops->connect(ds) and moves it somewhere where we already iterate
over all switches of a tree. That is in dsa_switch_setup_tag_protocol(),
which is a good placement because we already have there the connection
call to the switch side of things.
As for the dsa_tree_bind_tag_proto() method (called from the code path
that changes the tag protocol), things are a bit more complicated
because we receive the tree as argument, yet when we unwind on errors,
it would be nice to not call tag_ops->disconnect(ds) where we didn't
previously call tag_ops->connect(ds). We didn't have this problem before
because the tag_ops connection operations passed the entire dst before,
and this is more fine grained now. To solve the error rewind case using
the new API, we have to create yet one more cross-chip notifier for
disconnection, and stay connected with the old tag protocol to all the
switches in the tree until we've succeeded to connect with the new one
as well. So if something fails half way, the whole tree is still
connected to the old tagger. But there may still be leaks if the tagger
fails to connect to the 2nd out of 3 switches in a tree: somebody needs
to tell the tagger to disconnect from the first switch. Nothing comes
for free, and this was previously handled privately by the tagging
protocol driver before, but now we need to emit a disconnect cross-chip
notifier for that, because DSA has to take care of the unwind path. We
assume that the tagging protocol has connected to a switch if it has set
ds->tagger_data to something, otherwise we avoid calling its
disconnection method in the error rewind path.
The rest of the changes are in the tagging protocol drivers, and have to
do with the replacement of dst with ds. The iteration is removed and the
error unwind path is simplified, as mentioned above.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-12-14 01:45:36 +00:00
|
|
|
/* Notify the switch about the connection to the new tagger */
|
|
|
|
err = ds->ops->connect_tag_protocol(ds, tag_ops->proto);
|
|
|
|
if (err) {
|
|
|
|
/* Revert the new tagger's connection to this tree */
|
|
|
|
if (tag_ops->disconnect)
|
|
|
|
tag_ops->disconnect(ds);
|
|
|
|
return err;
|
|
|
|
}
|
|
|
|
|
|
|
|
return 0;
|
|
|
|
}
|
|
|
|
|
|
|
|
static int
|
|
|
|
dsa_switch_disconnect_tag_proto(struct dsa_switch *ds,
|
|
|
|
struct dsa_notifier_tag_proto_info *info)
|
|
|
|
{
|
|
|
|
const struct dsa_device_ops *tag_ops = info->tag_ops;
|
|
|
|
|
|
|
|
/* Notify the tagger about the disconnection from this switch */
|
|
|
|
if (tag_ops->disconnect && ds->tagger_data)
|
|
|
|
tag_ops->disconnect(ds);
|
|
|
|
|
|
|
|
/* No need to notify the switch, since it shouldn't have any
|
|
|
|
* resources to tear down
|
|
|
|
*/
|
|
|
|
return 0;
|
net: dsa: introduce tagger-owned storage for private and shared data
Ansuel is working on register access over Ethernet for the qca8k switch
family. This requires the qca8k tagging protocol driver to receive
frames which aren't intended for the network stack, but instead for the
qca8k switch driver itself.
The dp->priv is currently the prevailing method for passing data back
and forth between the tagging protocol driver and the switch driver.
However, this method is riddled with caveats.
The DSA design allows in principle for any switch driver to return any
protocol it desires in ->get_tag_protocol(). The dsa_loop driver can be
modified to do just that. But in the current design, the memory behind
dp->priv has to be allocated by the switch driver, so if the tagging
protocol is paired to an unexpected switch driver, we may end up in NULL
pointer dereferences inside the kernel, or worse (a switch driver may
allocate dp->priv according to the expectations of a different tagger).
The latter possibility is even more plausible considering that DSA
switches can dynamically change tagging protocols in certain cases
(dsa <-> edsa, ocelot <-> ocelot-8021q), and the current design lends
itself to mistakes that are all too easy to make.
This patch proposes that the tagging protocol driver should manage its
own memory, instead of relying on the switch driver to do so.
After analyzing the different in-tree needs, it can be observed that the
required tagger storage is per switch, therefore a ds->tagger_data
pointer is introduced. In principle, per-port storage could also be
introduced, although there is no need for it at the moment. Future
changes will replace the current usage of dp->priv with ds->tagger_data.
We define a "binding" event between the DSA switch tree and the tagging
protocol. During this binding event, the tagging protocol's ->connect()
method is called first, and this may allocate some memory for each
switch of the tree. Then a cross-chip notifier is emitted for the
switches within that tree, and they are given the opportunity to fix up
the tagger's memory (for example, they might set up some function
pointers that represent virtual methods for consuming packets).
Because the memory is owned by the tagger, there exists a ->disconnect()
method for the tagger (which is the place to free the resources), but
there doesn't exist a ->disconnect() method for the switch driver.
This is part of the design. The switch driver should make minimal use of
the public part of the tagger data, and only after type-checking it
using the supplied "proto" argument.
In the code there are in fact two binding events, one is the initial
event in dsa_switch_setup_tag_protocol(). At this stage, the cross chip
notifier chains aren't initialized, so we call each switch's connect()
method by hand. Then there is dsa_tree_bind_tag_proto() during
dsa_tree_change_tag_proto(), and here we have an old protocol and a new
one. We first connect to the new one before disconnecting from the old
one, to simplify error handling a bit and to ensure we remain in a valid
state at all times.
Co-developed-by: Ansuel Smith <ansuelsmth@gmail.com>
Signed-off-by: Ansuel Smith <ansuelsmth@gmail.com>
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-12-09 23:34:37 +00:00
|
|
|
}
|
|
|
|
|
net: dsa: provide switch operations for tracking the master state
Certain drivers may need to send management traffic to the switch for
things like register access, FDB dump, etc, to accelerate what their
slow bus (SPI, I2C, MDIO) can already do.
Ethernet is faster (especially in bulk transactions) but is also more
unreliable, since the user may decide to bring the DSA master down (or
not bring it up), therefore severing the link between the host and the
attached switch.
Drivers needing Ethernet-based register access already should have
fallback logic to the slow bus if the Ethernet method fails, but that
fallback may be based on a timeout, and the I/O to the switch may slow
down to a halt if the master is down, because every Ethernet packet will
have to time out. The driver also doesn't have the option to turn off
Ethernet-based I/O momentarily, because it wouldn't know when to turn it
back on.
Which is where this change comes in. By tracking NETDEV_CHANGE,
NETDEV_UP and NETDEV_GOING_DOWN events on the DSA master, we should know
the exact interval of time during which this interface is reliably
available for traffic. Provide this information to switches so they can
use it as they wish.
An helper is added dsa_port_master_is_operational() to check if a master
port is operational.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: Ansuel Smith <ansuelsmth@gmail.com>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-02-02 00:03:20 +00:00
|
|
|
static int
|
|
|
|
dsa_switch_master_state_change(struct dsa_switch *ds,
|
|
|
|
struct dsa_notifier_master_state_info *info)
|
|
|
|
{
|
|
|
|
if (!ds->ops->master_state_change)
|
|
|
|
return 0;
|
|
|
|
|
|
|
|
ds->ops->master_state_change(ds, info->master, info->operational);
|
|
|
|
|
|
|
|
return 0;
|
|
|
|
}
|
|
|
|
|
2017-02-03 18:20:20 +00:00
|
|
|
static int dsa_switch_event(struct notifier_block *nb,
|
|
|
|
unsigned long event, void *info)
|
|
|
|
{
|
|
|
|
struct dsa_switch *ds = container_of(nb, struct dsa_switch, nb);
|
|
|
|
int err;
|
|
|
|
|
|
|
|
switch (event) {
|
2017-05-19 21:00:52 +00:00
|
|
|
case DSA_NOTIFIER_AGEING_TIME:
|
|
|
|
err = dsa_switch_ageing_time(ds, info);
|
|
|
|
break;
|
2017-02-03 18:20:21 +00:00
|
|
|
case DSA_NOTIFIER_BRIDGE_JOIN:
|
|
|
|
err = dsa_switch_bridge_join(ds, info);
|
|
|
|
break;
|
|
|
|
case DSA_NOTIFIER_BRIDGE_LEAVE:
|
|
|
|
err = dsa_switch_bridge_leave(ds, info);
|
|
|
|
break;
|
2017-05-19 21:00:53 +00:00
|
|
|
case DSA_NOTIFIER_FDB_ADD:
|
|
|
|
err = dsa_switch_fdb_add(ds, info);
|
|
|
|
break;
|
|
|
|
case DSA_NOTIFIER_FDB_DEL:
|
|
|
|
err = dsa_switch_fdb_del(ds, info);
|
|
|
|
break;
|
2021-06-29 14:06:51 +00:00
|
|
|
case DSA_NOTIFIER_HOST_FDB_ADD:
|
|
|
|
err = dsa_switch_host_fdb_add(ds, info);
|
|
|
|
break;
|
|
|
|
case DSA_NOTIFIER_HOST_FDB_DEL:
|
|
|
|
err = dsa_switch_host_fdb_del(ds, info);
|
|
|
|
break;
|
net: dsa: support FDB events on offloaded LAG interfaces
This change introduces support for installing static FDB entries towards
a bridge port that is a LAG of multiple DSA switch ports, as well as
support for filtering towards the CPU local FDB entries emitted for LAG
interfaces that are bridge ports.
Conceptually, host addresses on LAG ports are identical to what we do
for plain bridge ports. Whereas FDB entries _towards_ a LAG can't simply
be replicated towards all member ports like we do for multicast, or VLAN.
Instead we need new driver API. Hardware usually considers a LAG to be a
"logical port", and sets the entire LAG as the forwarding destination.
The physical egress port selection within the LAG is made by hashing
policy, as usual.
To represent the logical port corresponding to the LAG, we pass by value
a copy of the dsa_lag structure to all switches in the tree that have at
least one port in that LAG.
To illustrate why a refcounted list of FDB entries is needed in struct
dsa_lag, it is enough to say that:
- a LAG may be a bridge port and may therefore receive FDB events even
while it isn't yet offloaded by any DSA interface
- DSA interfaces may be removed from a LAG while that is a bridge port;
we don't want FDB entries lingering around, but we don't want to
remove entries that are still in use, either
For all the cases below to work, the idea is to always keep an FDB entry
on a LAG with a reference count equal to the DSA member ports. So:
- if a port joins a LAG, it requests the bridge to replay the FDB, and
the FDB entries get created, or their refcount gets bumped by one
- if a port leaves a LAG, the FDB replay deletes or decrements refcount
by one
- if an FDB is installed towards a LAG with ports already present, that
entry is created (if it doesn't exist) and its refcount is bumped by
the amount of ports already present in the LAG
echo "Adding FDB entry to bond with existing ports"
ip link del bond0
ip link add bond0 type bond mode 802.3ad
ip link set swp1 down && ip link set swp1 master bond0 && ip link set swp1 up
ip link set swp2 down && ip link set swp2 master bond0 && ip link set swp2 up
ip link del br0
ip link add br0 type bridge
ip link set bond0 master br0
bridge fdb add dev bond0 00:01:02:03:04:05 master static
ip link del br0
ip link del bond0
echo "Adding FDB entry to empty bond"
ip link del bond0
ip link add bond0 type bond mode 802.3ad
ip link del br0
ip link add br0 type bridge
ip link set bond0 master br0
bridge fdb add dev bond0 00:01:02:03:04:05 master static
ip link set swp1 down && ip link set swp1 master bond0 && ip link set swp1 up
ip link set swp2 down && ip link set swp2 master bond0 && ip link set swp2 up
ip link del br0
ip link del bond0
echo "Adding FDB entry to empty bond, then removing ports one by one"
ip link del bond0
ip link add bond0 type bond mode 802.3ad
ip link del br0
ip link add br0 type bridge
ip link set bond0 master br0
bridge fdb add dev bond0 00:01:02:03:04:05 master static
ip link set swp1 down && ip link set swp1 master bond0 && ip link set swp1 up
ip link set swp2 down && ip link set swp2 master bond0 && ip link set swp2 up
ip link set swp1 nomaster
ip link set swp2 nomaster
ip link del br0
ip link del bond0
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: Jakub Kicinski <kuba@kernel.org>
2022-02-23 14:00:53 +00:00
|
|
|
case DSA_NOTIFIER_LAG_FDB_ADD:
|
|
|
|
err = dsa_switch_lag_fdb_add(ds, info);
|
|
|
|
break;
|
|
|
|
case DSA_NOTIFIER_LAG_FDB_DEL:
|
|
|
|
err = dsa_switch_lag_fdb_del(ds, info);
|
|
|
|
break;
|
2021-01-13 08:42:53 +00:00
|
|
|
case DSA_NOTIFIER_LAG_CHANGE:
|
|
|
|
err = dsa_switch_lag_change(ds, info);
|
|
|
|
break;
|
|
|
|
case DSA_NOTIFIER_LAG_JOIN:
|
|
|
|
err = dsa_switch_lag_join(ds, info);
|
|
|
|
break;
|
|
|
|
case DSA_NOTIFIER_LAG_LEAVE:
|
|
|
|
err = dsa_switch_lag_leave(ds, info);
|
|
|
|
break;
|
2017-05-19 21:00:54 +00:00
|
|
|
case DSA_NOTIFIER_MDB_ADD:
|
|
|
|
err = dsa_switch_mdb_add(ds, info);
|
|
|
|
break;
|
|
|
|
case DSA_NOTIFIER_MDB_DEL:
|
|
|
|
err = dsa_switch_mdb_del(ds, info);
|
|
|
|
break;
|
net: dsa: introduce a separate cross-chip notifier type for host MDBs
Commit abd49535c380 ("net: dsa: execute dsa_switch_mdb_add only for
routing port in cross-chip topologies") does a surprisingly good job
even for the SWITCHDEV_OBJ_ID_HOST_MDB use case, where DSA simply
translates a switchdev object received on dp into a cross-chip notifier
for dp->cpu_dp.
To visualize how that works, imagine the daisy chain topology below and
consider a SWITCHDEV_OBJ_ID_HOST_MDB object emitted on sw2p0. How does
the cross-chip notifier know to match on all the right ports (sw0p4, the
dedicated CPU port, sw1p4, an upstream DSA link, and sw2p4, another
upstream DSA link)?
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
[ ] [ ] [ ] [ ] [ x ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ user ] [ dsa ]
[ ] [ ] [ ] [ ] [ x ]
The answer is simple: the dedicated CPU port of sw2p0 is sw0p4, and
dsa_routing_port returns the upstream port for all switches.
That is fine, but there are other topologies where this does not work as
well. There are trees with "H" topologies in the wild, where there are 2
or more switches with DSA links between them, but every switch has its
dedicated CPU port. For these topologies, it seems stupid for the neighbor
switches to install an MDB entry on the routing port, since these
multicast addresses are fundamentally different than the usual ones we
support (and that is the justification for this patch, to introduce the
concept of a termination plane multicast MAC address, as opposed to a
forwarding plane multicast MAC address).
For example, when a SWITCHDEV_OBJ_ID_HOST_MDB would get added to sw0p0,
without this patch, it would get treated as a regular port MDB on sw0p2
and it would match on the ports below (including the sw1p3 routing port).
| |
sw0p0 sw0p1 sw0p2 sw0p3 sw1p3 sw1p2 sw1p1 sw1p0
[ user ] [ user ] [ cpu ] [ dsa ] [ dsa ] [ cpu ] [ user ] [ user ]
[ ] [ ] [ x ] [ ] ---- [ x ] [ ] [ ] [ ]
With the patch, the host MDB notifier on sw0p0 matches only on the local
switch, which is what we want for a termination plane address.
| |
sw0p0 sw0p1 sw0p2 sw0p3 sw1p3 sw1p2 sw1p1 sw1p0
[ user ] [ user ] [ cpu ] [ dsa ] [ dsa ] [ cpu ] [ user ] [ user ]
[ ] [ ] [ x ] [ ] ---- [ ] [ ] [ ] [ ]
Name this new matching function "dsa_switch_host_address_match" since we
will be reusing it soon for host FDB entries as well.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-06-29 14:06:49 +00:00
|
|
|
case DSA_NOTIFIER_HOST_MDB_ADD:
|
|
|
|
err = dsa_switch_host_mdb_add(ds, info);
|
|
|
|
break;
|
|
|
|
case DSA_NOTIFIER_HOST_MDB_DEL:
|
|
|
|
err = dsa_switch_host_mdb_del(ds, info);
|
|
|
|
break;
|
2017-05-19 21:00:55 +00:00
|
|
|
case DSA_NOTIFIER_VLAN_ADD:
|
|
|
|
err = dsa_switch_vlan_add(ds, info);
|
|
|
|
break;
|
|
|
|
case DSA_NOTIFIER_VLAN_DEL:
|
|
|
|
err = dsa_switch_vlan_del(ds, info);
|
|
|
|
break;
|
net: dsa: add explicit support for host bridge VLANs
Currently, DSA programs VLANs on shared (DSA and CPU) ports each time it
does so on user ports. This is good for basic functionality but has
several limitations:
- the VLAN group which must reach the CPU may be radically different
from the VLAN group that must be autonomously forwarded by the switch.
In other words, the admin may want to isolate noisy stations and avoid
traffic from them going to the control processor of the switch, where
it would just waste useless cycles. The bridge already supports
independent control of VLAN groups on bridge ports and on the bridge
itself, and when VLAN-aware, it will drop packets in software anyway
if their VID isn't added as a 'self' entry towards the bridge device.
- Replaying host FDB entries may depend, for some drivers like mv88e6xxx,
on replaying the host VLANs as well. The 2 VLAN groups are
approximately the same in most regular cases, but there are corner
cases when timing matters, and DSA's approximation of replicating
VLANs on shared ports simply does not work.
- If a user makes the bridge (implicitly the CPU port) join a VLAN by
accident, there is no way for the CPU port to isolate itself from that
noisy VLAN except by rebooting the system. This is because for each
VLAN added on a user port, DSA will add it on shared ports too, but
for each VLAN deletion on a user port, it will remain installed on
shared ports, since DSA has no good indication of whether the VLAN is
still in use or not.
Now that the bridge driver emits well-balanced SWITCHDEV_OBJ_ID_PORT_VLAN
addition and removal events, DSA has a simple and straightforward task
of separating the bridge port VLANs (these have an orig_dev which is a
DSA slave interface, or a LAG interface) from the host VLANs (these have
an orig_dev which is a bridge interface), and to keep a simple reference
count of each VID on each shared port.
Forwarding VLANs must be installed on the bridge ports and on all DSA
ports interconnecting them. We don't have a good view of the exact
topology, so we simply install forwarding VLANs on all DSA ports, which
is what has been done until now.
Host VLANs must be installed primarily on the dedicated CPU port of each
bridge port. More subtly, they must also be installed on upstream-facing
and downstream-facing DSA ports that are connecting the bridge ports and
the CPU. This ensures that the mv88e6xxx's problem (VID of host FDB
entry may be absent from VTU) is still addressed even if that switch is
in a cross-chip setup, and it has no local CPU port.
Therefore:
- user ports contain only bridge port (forwarding) VLANs, and no
refcounting is necessary
- DSA ports contain both forwarding and host VLANs. Refcounting is
necessary among these 2 types.
- CPU ports contain only host VLANs. Refcounting is also necessary.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-02-15 17:02:17 +00:00
|
|
|
case DSA_NOTIFIER_HOST_VLAN_ADD:
|
|
|
|
err = dsa_switch_host_vlan_add(ds, info);
|
|
|
|
break;
|
|
|
|
case DSA_NOTIFIER_HOST_VLAN_DEL:
|
|
|
|
err = dsa_switch_host_vlan_del(ds, info);
|
|
|
|
break;
|
net: dsa: configure the MTU for switch ports
It is useful be able to configure port policers on a switch to accept
frames of various sizes:
- Increase the MTU for better throughput from the default of 1500 if it
is known that there is no 10/100 Mbps device in the network.
- Decrease the MTU to limit the latency of high-priority frames under
congestion, or work around various network segments that add extra
headers to packets which can't be fragmented.
For DSA slave ports, this is mostly a pass-through callback, called
through the regular ndo ops and at probe time (to ensure consistency
across all supported switches).
The CPU port is called with an MTU equal to the largest configured MTU
of the slave ports. The assumption is that the user might want to
sustain a bidirectional conversation with a partner over any switch
port.
The DSA master is configured the same as the CPU port, plus the tagger
overhead. Since the MTU is by definition L2 payload (sans Ethernet
header), it is up to each individual driver to figure out if it needs to
do anything special for its frame tags on the CPU port (it shouldn't
except in special cases). So the MTU does not contain the tagger
overhead on the CPU port.
However the MTU of the DSA master, minus the tagger overhead, is used as
a proxy for the MTU of the CPU port, which does not have a net device.
This is to avoid uselessly calling the .change_mtu function on the CPU
port when nothing should change.
So it is safe to assume that the DSA master and the CPU port MTUs are
apart by exactly the tagger's overhead in bytes.
Some changes were made around dsa_master_set_mtu(), function which was
now removed, for 2 reasons:
- dev_set_mtu() already calls dev_validate_mtu(), so it's redundant to
do the same thing in DSA
- __dev_set_mtu() returns 0 if ops->ndo_change_mtu is an absent method
That is to say, there's no need for this function in DSA, we can safely
call dev_set_mtu() directly, take the rtnl lock when necessary, and just
propagate whatever errors get reported (since the user probably wants to
be informed).
Some inspiration (mainly in the MTU DSA notifier) was taken from a
vaguely similar patch from Murali and Florian, who are credited as
co-developers down below.
Co-developed-by: Murali Krishna Policharla <murali.policharla@broadcom.com>
Signed-off-by: Murali Krishna Policharla <murali.policharla@broadcom.com>
Co-developed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2020-03-27 19:55:42 +00:00
|
|
|
case DSA_NOTIFIER_MTU:
|
|
|
|
err = dsa_switch_mtu(ds, info);
|
|
|
|
break;
|
net: dsa: allow changing the tag protocol via the "tagging" device attribute
Currently DSA exposes the following sysfs:
$ cat /sys/class/net/eno2/dsa/tagging
ocelot
which is a read-only device attribute, introduced in the kernel as
commit 98cdb4807123 ("net: dsa: Expose tagging protocol to user-space"),
and used by libpcap since its commit 993db3800d7d ("Add support for DSA
link-layer types").
It would be nice if we could extend this device attribute by making it
writable:
$ echo ocelot-8021q > /sys/class/net/eno2/dsa/tagging
This is useful with DSA switches that can make use of more than one
tagging protocol. It may be useful in dsa_loop in the future too, to
perform offline testing of various taggers, or for changing between dsa
and edsa on Marvell switches, if that is desirable.
In terms of implementation, drivers can support this feature by
implementing .change_tag_protocol, which should always leave the switch
in a consistent state: either with the new protocol if things went well,
or with the old one if something failed. Teardown of the old protocol,
if necessary, must be handled by the driver.
Some things remain as before:
- The .get_tag_protocol is currently only called at probe time, to load
the initial tagging protocol driver. Nonetheless, new drivers should
report the tagging protocol in current use now.
- The driver should manage by itself the initial setup of tagging
protocol, no later than the .setup() method, as well as destroying
resources used by the last tagger in use, no earlier than the
.teardown() method.
For multi-switch DSA trees, error handling is a bit more complicated,
since e.g. the 5th out of 7 switches may fail to change the tag
protocol. When that happens, a revert to the original tag protocol is
attempted, but that may fail too, leaving the tree in an inconsistent
state despite each individual switch implementing .change_tag_protocol
transactionally. Since the intersection between drivers that implement
.change_tag_protocol and drivers that support D in DSA is currently the
empty set, the possibility for this error to happen is ignored for now.
Testing:
$ insmod mscc_felix.ko
[ 79.549784] mscc_felix 0000:00:00.5: Adding to iommu group 14
[ 79.565712] mscc_felix 0000:00:00.5: Failed to register DSA switch: -517
$ insmod tag_ocelot.ko
$ rmmod mscc_felix.ko
$ insmod mscc_felix.ko
[ 97.261724] libphy: VSC9959 internal MDIO bus: probed
[ 97.267363] mscc_felix 0000:00:00.5: Found PCS at internal MDIO address 0
[ 97.274998] mscc_felix 0000:00:00.5: Found PCS at internal MDIO address 1
[ 97.282561] mscc_felix 0000:00:00.5: Found PCS at internal MDIO address 2
[ 97.289700] mscc_felix 0000:00:00.5: Found PCS at internal MDIO address 3
[ 97.599163] mscc_felix 0000:00:00.5 swp0 (uninitialized): PHY [0000:00:00.3:10] driver [Microsemi GE VSC8514 SyncE] (irq=POLL)
[ 97.862034] mscc_felix 0000:00:00.5 swp1 (uninitialized): PHY [0000:00:00.3:11] driver [Microsemi GE VSC8514 SyncE] (irq=POLL)
[ 97.950731] mscc_felix 0000:00:00.5 swp0: configuring for inband/qsgmii link mode
[ 97.964278] 8021q: adding VLAN 0 to HW filter on device swp0
[ 98.146161] mscc_felix 0000:00:00.5 swp2 (uninitialized): PHY [0000:00:00.3:12] driver [Microsemi GE VSC8514 SyncE] (irq=POLL)
[ 98.238649] mscc_felix 0000:00:00.5 swp1: configuring for inband/qsgmii link mode
[ 98.251845] 8021q: adding VLAN 0 to HW filter on device swp1
[ 98.433916] mscc_felix 0000:00:00.5 swp3 (uninitialized): PHY [0000:00:00.3:13] driver [Microsemi GE VSC8514 SyncE] (irq=POLL)
[ 98.485542] mscc_felix 0000:00:00.5: configuring for fixed/internal link mode
[ 98.503584] mscc_felix 0000:00:00.5: Link is Up - 2.5Gbps/Full - flow control rx/tx
[ 98.527948] device eno2 entered promiscuous mode
[ 98.544755] DSA: tree 0 setup
$ ping 10.0.0.1
PING 10.0.0.1 (10.0.0.1): 56 data bytes
64 bytes from 10.0.0.1: seq=0 ttl=64 time=2.337 ms
64 bytes from 10.0.0.1: seq=1 ttl=64 time=0.754 ms
^C
- 10.0.0.1 ping statistics -
2 packets transmitted, 2 packets received, 0% packet loss
round-trip min/avg/max = 0.754/1.545/2.337 ms
$ cat /sys/class/net/eno2/dsa/tagging
ocelot
$ cat ./test_ocelot_8021q.sh
#!/bin/bash
ip link set swp0 down
ip link set swp1 down
ip link set swp2 down
ip link set swp3 down
ip link set swp5 down
ip link set eno2 down
echo ocelot-8021q > /sys/class/net/eno2/dsa/tagging
ip link set eno2 up
ip link set swp0 up
ip link set swp1 up
ip link set swp2 up
ip link set swp3 up
ip link set swp5 up
$ ./test_ocelot_8021q.sh
./test_ocelot_8021q.sh: line 9: echo: write error: Protocol not available
$ rmmod tag_ocelot.ko
rmmod: can't unload module 'tag_ocelot': Resource temporarily unavailable
$ insmod tag_ocelot_8021q.ko
$ ./test_ocelot_8021q.sh
$ cat /sys/class/net/eno2/dsa/tagging
ocelot-8021q
$ rmmod tag_ocelot.ko
$ rmmod tag_ocelot_8021q.ko
rmmod: can't unload module 'tag_ocelot_8021q': Resource temporarily unavailable
$ ping 10.0.0.1
PING 10.0.0.1 (10.0.0.1): 56 data bytes
64 bytes from 10.0.0.1: seq=0 ttl=64 time=0.953 ms
64 bytes from 10.0.0.1: seq=1 ttl=64 time=0.787 ms
64 bytes from 10.0.0.1: seq=2 ttl=64 time=0.771 ms
$ rmmod mscc_felix.ko
[ 645.544426] mscc_felix 0000:00:00.5: Link is Down
[ 645.838608] DSA: tree 0 torn down
$ rmmod tag_ocelot_8021q.ko
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: Jakub Kicinski <kuba@kernel.org>
2021-01-29 01:00:06 +00:00
|
|
|
case DSA_NOTIFIER_TAG_PROTO:
|
|
|
|
err = dsa_switch_change_tag_proto(ds, info);
|
|
|
|
break;
|
net: dsa: introduce tagger-owned storage for private and shared data
Ansuel is working on register access over Ethernet for the qca8k switch
family. This requires the qca8k tagging protocol driver to receive
frames which aren't intended for the network stack, but instead for the
qca8k switch driver itself.
The dp->priv is currently the prevailing method for passing data back
and forth between the tagging protocol driver and the switch driver.
However, this method is riddled with caveats.
The DSA design allows in principle for any switch driver to return any
protocol it desires in ->get_tag_protocol(). The dsa_loop driver can be
modified to do just that. But in the current design, the memory behind
dp->priv has to be allocated by the switch driver, so if the tagging
protocol is paired to an unexpected switch driver, we may end up in NULL
pointer dereferences inside the kernel, or worse (a switch driver may
allocate dp->priv according to the expectations of a different tagger).
The latter possibility is even more plausible considering that DSA
switches can dynamically change tagging protocols in certain cases
(dsa <-> edsa, ocelot <-> ocelot-8021q), and the current design lends
itself to mistakes that are all too easy to make.
This patch proposes that the tagging protocol driver should manage its
own memory, instead of relying on the switch driver to do so.
After analyzing the different in-tree needs, it can be observed that the
required tagger storage is per switch, therefore a ds->tagger_data
pointer is introduced. In principle, per-port storage could also be
introduced, although there is no need for it at the moment. Future
changes will replace the current usage of dp->priv with ds->tagger_data.
We define a "binding" event between the DSA switch tree and the tagging
protocol. During this binding event, the tagging protocol's ->connect()
method is called first, and this may allocate some memory for each
switch of the tree. Then a cross-chip notifier is emitted for the
switches within that tree, and they are given the opportunity to fix up
the tagger's memory (for example, they might set up some function
pointers that represent virtual methods for consuming packets).
Because the memory is owned by the tagger, there exists a ->disconnect()
method for the tagger (which is the place to free the resources), but
there doesn't exist a ->disconnect() method for the switch driver.
This is part of the design. The switch driver should make minimal use of
the public part of the tagger data, and only after type-checking it
using the supplied "proto" argument.
In the code there are in fact two binding events, one is the initial
event in dsa_switch_setup_tag_protocol(). At this stage, the cross chip
notifier chains aren't initialized, so we call each switch's connect()
method by hand. Then there is dsa_tree_bind_tag_proto() during
dsa_tree_change_tag_proto(), and here we have an old protocol and a new
one. We first connect to the new one before disconnecting from the old
one, to simplify error handling a bit and to ensure we remain in a valid
state at all times.
Co-developed-by: Ansuel Smith <ansuelsmth@gmail.com>
Signed-off-by: Ansuel Smith <ansuelsmth@gmail.com>
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-12-09 23:34:37 +00:00
|
|
|
case DSA_NOTIFIER_TAG_PROTO_CONNECT:
|
|
|
|
err = dsa_switch_connect_tag_proto(ds, info);
|
|
|
|
break;
|
net: dsa: make tagging protocols connect to individual switches from a tree
On the NXP Bluebox 3 board which uses a multi-switch setup with sja1105,
the mechanism through which the tagger connects to the switch tree is
broken, due to improper DSA code design. At the time when tag_ops->connect()
is called in dsa_port_parse_cpu(), DSA hasn't finished "touching" all
the ports, so it doesn't know how large the tree is and how many ports
it has. It has just seen the first CPU port by this time. As a result,
this function will call the tagger's ->connect method too early, and the
tagger will connect only to the first switch from the tree.
This could be perhaps addressed a bit more simply by just moving the
tag_ops->connect(dst) call a bit later (for example in dsa_tree_setup),
but there is already a design inconsistency at present: on the switch
side, the notification is on a per-switch basis, but on the tagger side,
it is on a per-tree basis. Furthermore, the persistent storage itself is
per switch (ds->tagger_data). And the tagger connect and disconnect
procedures (at least the ones that exist currently) could see a fair bit
of simplification if they didn't have to iterate through the switches of
a tree.
To fix the issue, this change transforms tag_ops->connect(dst) into
tag_ops->connect(ds) and moves it somewhere where we already iterate
over all switches of a tree. That is in dsa_switch_setup_tag_protocol(),
which is a good placement because we already have there the connection
call to the switch side of things.
As for the dsa_tree_bind_tag_proto() method (called from the code path
that changes the tag protocol), things are a bit more complicated
because we receive the tree as argument, yet when we unwind on errors,
it would be nice to not call tag_ops->disconnect(ds) where we didn't
previously call tag_ops->connect(ds). We didn't have this problem before
because the tag_ops connection operations passed the entire dst before,
and this is more fine grained now. To solve the error rewind case using
the new API, we have to create yet one more cross-chip notifier for
disconnection, and stay connected with the old tag protocol to all the
switches in the tree until we've succeeded to connect with the new one
as well. So if something fails half way, the whole tree is still
connected to the old tagger. But there may still be leaks if the tagger
fails to connect to the 2nd out of 3 switches in a tree: somebody needs
to tell the tagger to disconnect from the first switch. Nothing comes
for free, and this was previously handled privately by the tagging
protocol driver before, but now we need to emit a disconnect cross-chip
notifier for that, because DSA has to take care of the unwind path. We
assume that the tagging protocol has connected to a switch if it has set
ds->tagger_data to something, otherwise we avoid calling its
disconnection method in the error rewind path.
The rest of the changes are in the tagging protocol drivers, and have to
do with the replacement of dst with ds. The iteration is removed and the
error unwind path is simplified, as mentioned above.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-12-14 01:45:36 +00:00
|
|
|
case DSA_NOTIFIER_TAG_PROTO_DISCONNECT:
|
|
|
|
err = dsa_switch_disconnect_tag_proto(ds, info);
|
|
|
|
break;
|
net: dsa: tag_8021q: add proper cross-chip notifier support
The big problem which mandates cross-chip notifiers for tag_8021q is
this:
|
sw0p0 sw0p1 sw0p2 sw0p3 sw0p4
[ user ] [ user ] [ user ] [ dsa ] [ cpu ]
|
+---------+
|
sw1p0 sw1p1 sw1p2 sw1p3 sw1p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
|
+---------+
|
sw2p0 sw2p1 sw2p2 sw2p3 sw2p4
[ user ] [ user ] [ user ] [ dsa ] [ dsa ]
When the user runs:
ip link add br0 type bridge
ip link set sw0p0 master br0
ip link set sw2p0 master br0
It doesn't work.
This is because dsa_8021q_crosschip_bridge_join() assumes that "ds" and
"other_ds" are at most 1 hop away from each other, so it is sufficient
to add the RX VLAN of {ds, port} into {other_ds, other_port} and vice
versa and presto, the cross-chip link works. When there is another
switch in the middle, such as in this case switch 1 with its DSA links
sw1p3 and sw1p4, somebody needs to tell it about these VLANs too.
Which is exactly why the problem is quadratic: when a port joins a
bridge, for each port in the tree that's already in that same bridge we
notify a tag_8021q VLAN addition of that port's RX VLAN to the entire
tree. It is a very complicated web of VLANs.
It must be mentioned that currently we install tag_8021q VLANs on too
many ports (DSA links - to be precise, on all of them). For example,
when sw2p0 joins br0, and assuming sw1p0 was part of br0 too, we add the
RX VLAN of sw2p0 on the DSA links of switch 0 too, even though there
isn't any port of switch 0 that is a member of br0 (at least yet).
In theory we could notify only the switches which sit in between the
port joining the bridge and the port reacting to that bridge_join event.
But in practice that is impossible, because of the way 'link' properties
are described in the device tree. The DSA bindings require DT writers to
list out not only the real/physical DSA links, but in fact the entire
routing table, like for example switch 0 above will have:
sw0p3: port@3 {
link = <&sw1p4 &sw2p4>;
};
This was done because:
/* TODO: ideally DSA ports would have a single dp->link_dp member,
* and no dst->rtable nor this struct dsa_link would be needed,
* but this would require some more complex tree walking,
* so keep it stupid at the moment and list them all.
*/
but it is a perfect example of a situation where too much information is
actively detrimential, because we are now in the position where we
cannot distinguish a real DSA link from one that is put there to avoid
the 'complex tree walking'. And because DT is ABI, there is not much we
can change.
And because we do not know which DSA links are real and which ones
aren't, we can't really know if DSA switch A is in the data path between
switches B and C, in the general case.
So this is why tag_8021q RX VLANs are added on all DSA links, and
probably why it will never change.
On the other hand, at least the number of additions/deletions is well
balanced, and this means that once we implement reference counting at
the cross-chip notifier level a la fdb/mdb, there is absolutely zero
need for a struct dsa_8021q_crosschip_link, it's all self-managing.
In fact, with the tag_8021q notifiers emitted from the bridge join
notifiers, it becomes so generic that sja1105 does not need to do
anything anymore, we can just delete its implementation of the
.crosschip_bridge_{join,leave} methods.
Among other things we can simply delete is the home-grown implementation
of sja1105_notify_crosschip_switches(). The reason why that is wrong is
because it is not quadratic - it only covers remote switches to which we
have a cross-chip bridging link and that does not cover in-between
switches. This deletion is part of the same patch because sja1105 used
to poke deep inside the guts of the tag_8021q context in order to do
that. Because the cross-chip links went away, so needs the sja1105 code.
Last but not least, dsa_8021q_setup_port() is simplified (and also
renamed). Because our TAG_8021Q_VLAN_ADD notifier is designed to react
on the CPU port too, the four dsa_8021q_vid_apply() calls:
- 1 for RX VLAN on user port
- 1 for the user port's RX VLAN on the CPU port
- 1 for TX VLAN on user port
- 1 for the user port's TX VLAN on the CPU port
now get squashed into only 2 notifier calls via
dsa_port_tag_8021q_vlan_add.
And because the notifiers to add and to delete a tag_8021q VLAN are
distinct, now we finally break up the port setup and teardown into
separate functions instead of relying on a "bool enabled" flag which
tells us what to do. Arguably it should have been this way from the
get go.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2021-07-19 17:14:52 +00:00
|
|
|
case DSA_NOTIFIER_TAG_8021Q_VLAN_ADD:
|
|
|
|
err = dsa_switch_tag_8021q_vlan_add(ds, info);
|
|
|
|
break;
|
|
|
|
case DSA_NOTIFIER_TAG_8021Q_VLAN_DEL:
|
|
|
|
err = dsa_switch_tag_8021q_vlan_del(ds, info);
|
|
|
|
break;
|
net: dsa: provide switch operations for tracking the master state
Certain drivers may need to send management traffic to the switch for
things like register access, FDB dump, etc, to accelerate what their
slow bus (SPI, I2C, MDIO) can already do.
Ethernet is faster (especially in bulk transactions) but is also more
unreliable, since the user may decide to bring the DSA master down (or
not bring it up), therefore severing the link between the host and the
attached switch.
Drivers needing Ethernet-based register access already should have
fallback logic to the slow bus if the Ethernet method fails, but that
fallback may be based on a timeout, and the I/O to the switch may slow
down to a halt if the master is down, because every Ethernet packet will
have to time out. The driver also doesn't have the option to turn off
Ethernet-based I/O momentarily, because it wouldn't know when to turn it
back on.
Which is where this change comes in. By tracking NETDEV_CHANGE,
NETDEV_UP and NETDEV_GOING_DOWN events on the DSA master, we should know
the exact interval of time during which this interface is reliably
available for traffic. Provide this information to switches so they can
use it as they wish.
An helper is added dsa_port_master_is_operational() to check if a master
port is operational.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: Ansuel Smith <ansuelsmth@gmail.com>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2022-02-02 00:03:20 +00:00
|
|
|
case DSA_NOTIFIER_MASTER_STATE_CHANGE:
|
|
|
|
err = dsa_switch_master_state_change(ds, info);
|
|
|
|
break;
|
2017-02-03 18:20:20 +00:00
|
|
|
default:
|
|
|
|
err = -EOPNOTSUPP;
|
|
|
|
break;
|
|
|
|
}
|
|
|
|
|
|
|
|
if (err)
|
|
|
|
dev_dbg(ds->dev, "breaking chain for DSA event %lu (%d)\n",
|
|
|
|
event, err);
|
|
|
|
|
|
|
|
return notifier_from_errno(err);
|
|
|
|
}
|
|
|
|
|
|
|
|
int dsa_switch_register_notifier(struct dsa_switch *ds)
|
|
|
|
{
|
|
|
|
ds->nb.notifier_call = dsa_switch_event;
|
|
|
|
|
|
|
|
return raw_notifier_chain_register(&ds->dst->nh, &ds->nb);
|
|
|
|
}
|
|
|
|
|
|
|
|
void dsa_switch_unregister_notifier(struct dsa_switch *ds)
|
|
|
|
{
|
|
|
|
int err;
|
|
|
|
|
|
|
|
err = raw_notifier_chain_unregister(&ds->dst->nh, &ds->nb);
|
|
|
|
if (err)
|
|
|
|
dev_err(ds->dev, "failed to unregister notifier (%d)\n", err);
|
|
|
|
}
|