2013-08-09 14:49:19 +00:00
|
|
|
NVIDIA Tegra PCIe controller
|
|
|
|
|
|
|
|
Required properties:
|
2015-01-30 22:11:04 +00:00
|
|
|
- compatible: For Tegra20, must contain "nvidia,tegra20-pcie". For Tegra30,
|
|
|
|
"nvidia,tegra30-pcie". For Tegra124, must contain "nvidia,tegra124-pcie".
|
|
|
|
Otherwise, must contain "nvidia,<chip>-pcie", plus one of the above, where
|
|
|
|
<chip> is tegra132 or tegra210.
|
2013-08-09 14:49:19 +00:00
|
|
|
- device_type: Must be "pci"
|
|
|
|
- reg: A list of physical base address and length for each set of controller
|
|
|
|
registers. Must contain an entry for each entry in the reg-names property.
|
|
|
|
- reg-names: Must include the following entries:
|
|
|
|
"pads": PADS registers
|
|
|
|
"afi": AFI registers
|
|
|
|
"cs": configuration space region
|
|
|
|
- interrupts: A list of interrupt outputs of the controller. Must contain an
|
|
|
|
entry for each entry in the interrupt-names property.
|
|
|
|
- interrupt-names: Must include the following entries:
|
|
|
|
"intr": The Tegra interrupt that is asserted for controller interrupts
|
|
|
|
"msi": The Tegra interrupt that is asserted when an MSI is received
|
|
|
|
- bus-range: Range of bus numbers associated with this controller
|
|
|
|
- #address-cells: Address representation for root ports (must be 3)
|
|
|
|
- cell 0 specifies the bus and device numbers of the root port:
|
|
|
|
[23:16]: bus number
|
|
|
|
[15:11]: device number
|
|
|
|
- cell 1 denotes the upper 32 address bits and should be 0
|
|
|
|
- cell 2 contains the lower 32 address bits and is used to translate to the
|
|
|
|
CPU address space
|
|
|
|
- #size-cells: Size representation for root ports (must be 2)
|
|
|
|
- ranges: Describes the translation of addresses for root ports and standard
|
|
|
|
PCI regions. The entries must be 6 cells each, where the first three cells
|
|
|
|
correspond to the address as described for the #address-cells property
|
|
|
|
above, the fourth cell is the physical CPU address to translate to and the
|
|
|
|
fifth and six cells are as described for the #size-cells property above.
|
|
|
|
- The first two entries are expected to translate the addresses for the root
|
|
|
|
port registers, which are referenced by the assigned-addresses property of
|
|
|
|
the root port nodes (see below).
|
|
|
|
- The remaining entries setup the mapping for the standard I/O, memory and
|
|
|
|
prefetchable PCI regions. The first cell determines the type of region
|
|
|
|
that is setup:
|
|
|
|
- 0x81000000: I/O memory region
|
|
|
|
- 0x82000000: non-prefetchable memory region
|
|
|
|
- 0xc2000000: prefetchable memory region
|
|
|
|
Please refer to the standard PCI bus binding document for a more detailed
|
|
|
|
explanation.
|
2014-03-05 13:25:46 +00:00
|
|
|
- #interrupt-cells: Size representation for interrupts (must be 1)
|
|
|
|
- interrupt-map-mask and interrupt-map: Standard PCI IRQ mapping properties
|
|
|
|
Please refer to the standard PCI bus binding document for a more detailed
|
|
|
|
explanation.
|
2013-11-06 21:00:25 +00:00
|
|
|
- clocks: Must contain an entry for each entry in clock-names.
|
|
|
|
See ../clocks/clock-bindings.txt for details.
|
2013-08-09 14:49:19 +00:00
|
|
|
- clock-names: Must include the following entries:
|
2013-11-06 21:00:25 +00:00
|
|
|
- pex
|
|
|
|
- afi
|
|
|
|
- pll_e
|
|
|
|
- cml (not required for Tegra20)
|
2013-11-07 17:11:27 +00:00
|
|
|
- resets: Must contain an entry for each entry in reset-names.
|
|
|
|
See ../reset/reset.txt for details.
|
|
|
|
- reset-names: Must include the following entries:
|
|
|
|
- pex
|
|
|
|
- afi
|
|
|
|
- pcie_x
|
2013-08-09 14:49:19 +00:00
|
|
|
|
2014-08-26 15:11:38 +00:00
|
|
|
Required properties on Tegra124 and later:
|
|
|
|
- phys: Must contain an entry for each entry in phy-names.
|
|
|
|
- phy-names: Must include the following entries:
|
|
|
|
- pcie
|
|
|
|
|
2014-05-28 14:49:11 +00:00
|
|
|
Power supplies for Tegra20:
|
|
|
|
- avdd-pex-supply: Power supply for analog PCIe logic. Must supply 1.05 V.
|
|
|
|
- vdd-pex-supply: Power supply for digital PCIe I/O. Must supply 1.05 V.
|
|
|
|
- avdd-pex-pll-supply: Power supply for dedicated (internal) PCIe PLL. Must
|
|
|
|
supply 1.05 V.
|
|
|
|
- avdd-plle-supply: Power supply for PLLE, which is shared with SATA. Must
|
|
|
|
supply 1.05 V.
|
|
|
|
- vddio-pex-clk-supply: Power supply for PCIe clock. Must supply 3.3 V.
|
|
|
|
|
|
|
|
Power supplies for Tegra30:
|
|
|
|
- Required:
|
|
|
|
- avdd-pex-pll-supply: Power supply for dedicated (internal) PCIe PLL. Must
|
|
|
|
supply 1.05 V.
|
|
|
|
- avdd-plle-supply: Power supply for PLLE, which is shared with SATA. Must
|
|
|
|
supply 1.05 V.
|
|
|
|
- vddio-pex-ctl-supply: Power supply for PCIe control I/O partition. Must
|
|
|
|
supply 1.8 V.
|
|
|
|
- hvdd-pex-supply: High-voltage supply for PCIe I/O and PCIe output clocks.
|
|
|
|
Must supply 3.3 V.
|
|
|
|
- Optional:
|
|
|
|
- If lanes 0 to 3 are used:
|
|
|
|
- avdd-pexa-supply: Power supply for analog PCIe logic. Must supply 1.05 V.
|
|
|
|
- vdd-pexa-supply: Power supply for digital PCIe I/O. Must supply 1.05 V.
|
|
|
|
- If lanes 4 or 5 are used:
|
|
|
|
- avdd-pexb-supply: Power supply for analog PCIe logic. Must supply 1.05 V.
|
|
|
|
- vdd-pexb-supply: Power supply for digital PCIe I/O. Must supply 1.05 V.
|
|
|
|
|
2014-08-26 15:11:38 +00:00
|
|
|
Power supplies for Tegra124:
|
|
|
|
- Required:
|
|
|
|
- avddio-pex-supply: Power supply for analog PCIe logic. Must supply 1.05 V.
|
|
|
|
- dvddio-pex-supply: Power supply for digital PCIe I/O. Must supply 1.05 V.
|
|
|
|
- avdd-pex-pll-supply: Power supply for dedicated (internal) PCIe PLL. Must
|
|
|
|
supply 1.05 V.
|
|
|
|
- hvdd-pex-supply: High-voltage supply for PCIe I/O and PCIe output clocks.
|
|
|
|
Must supply 3.3 V.
|
|
|
|
- hvdd-pex-pll-e-supply: High-voltage supply for PLLE (shared with USB3).
|
|
|
|
Must supply 3.3 V.
|
|
|
|
- vddio-pex-ctl-supply: Power supply for PCIe control I/O partition. Must
|
|
|
|
supply 2.8-3.3 V.
|
|
|
|
- avdd-pll-erefe-supply: Power supply for PLLE (shared with USB3). Must
|
|
|
|
supply 1.05 V.
|
|
|
|
|
2013-08-09 14:49:19 +00:00
|
|
|
Root ports are defined as subnodes of the PCIe controller node.
|
|
|
|
|
|
|
|
Required properties:
|
|
|
|
- device_type: Must be "pci"
|
|
|
|
- assigned-addresses: Address and size of the port configuration registers
|
|
|
|
- reg: PCI bus address of the root port
|
|
|
|
- #address-cells: Must be 3
|
|
|
|
- #size-cells: Must be 2
|
|
|
|
- ranges: Sub-ranges distributed from the PCIe controller node. An empty
|
|
|
|
property is sufficient.
|
|
|
|
- nvidia,num-lanes: Number of lanes to use for this port. Valid combinations
|
|
|
|
are:
|
|
|
|
- Root port 0 uses 4 lanes, root port 1 is unused.
|
|
|
|
- Both root ports use 2 lanes.
|
|
|
|
|
|
|
|
Example:
|
|
|
|
|
|
|
|
SoC DTSI:
|
|
|
|
|
|
|
|
pcie-controller {
|
|
|
|
compatible = "nvidia,tegra20-pcie";
|
|
|
|
device_type = "pci";
|
|
|
|
reg = <0x80003000 0x00000800 /* PADS registers */
|
|
|
|
0x80003800 0x00000200 /* AFI registers */
|
|
|
|
0x90000000 0x10000000>; /* configuration space */
|
|
|
|
reg-names = "pads", "afi", "cs";
|
|
|
|
interrupts = <0 98 0x04 /* controller interrupt */
|
|
|
|
0 99 0x04>; /* MSI interrupt */
|
|
|
|
interrupt-names = "intr", "msi";
|
|
|
|
|
2014-03-05 13:25:46 +00:00
|
|
|
#interrupt-cells = <1>;
|
|
|
|
interrupt-map-mask = <0 0 0 0>;
|
|
|
|
interrupt-map = <0 0 0 0 &intc GIC_SPI 98 IRQ_TYPE_LEVEL_HIGH>;
|
|
|
|
|
2013-08-09 14:49:19 +00:00
|
|
|
bus-range = <0x00 0xff>;
|
|
|
|
#address-cells = <3>;
|
|
|
|
#size-cells = <2>;
|
|
|
|
|
|
|
|
ranges = <0x82000000 0 0x80000000 0x80000000 0 0x00001000 /* port 0 registers */
|
|
|
|
0x82000000 0 0x80001000 0x80001000 0 0x00001000 /* port 1 registers */
|
|
|
|
0x81000000 0 0 0x82000000 0 0x00010000 /* downstream I/O */
|
|
|
|
0x82000000 0 0xa0000000 0xa0000000 0 0x10000000 /* non-prefetchable memory */
|
|
|
|
0xc2000000 0 0xb0000000 0xb0000000 0 0x10000000>; /* prefetchable memory */
|
|
|
|
|
2013-11-07 17:11:27 +00:00
|
|
|
clocks = <&tegra_car 70>, <&tegra_car 72>, <&tegra_car 118>;
|
|
|
|
clock-names = "pex", "afi", "pll_e";
|
|
|
|
resets = <&tegra_car 70>, <&tegra_car 72>, <&tegra_car 74>;
|
|
|
|
reset-names = "pex", "afi", "pcie_x";
|
2013-08-09 14:49:19 +00:00
|
|
|
status = "disabled";
|
|
|
|
|
|
|
|
pci@1,0 {
|
|
|
|
device_type = "pci";
|
|
|
|
assigned-addresses = <0x82000800 0 0x80000000 0 0x1000>;
|
|
|
|
reg = <0x000800 0 0 0 0>;
|
|
|
|
status = "disabled";
|
|
|
|
|
|
|
|
#address-cells = <3>;
|
|
|
|
#size-cells = <2>;
|
|
|
|
|
|
|
|
ranges;
|
|
|
|
|
|
|
|
nvidia,num-lanes = <2>;
|
|
|
|
};
|
|
|
|
|
|
|
|
pci@2,0 {
|
|
|
|
device_type = "pci";
|
|
|
|
assigned-addresses = <0x82001000 0 0x80001000 0 0x1000>;
|
|
|
|
reg = <0x001000 0 0 0 0>;
|
|
|
|
status = "disabled";
|
|
|
|
|
|
|
|
#address-cells = <3>;
|
|
|
|
#size-cells = <2>;
|
|
|
|
|
|
|
|
ranges;
|
|
|
|
|
|
|
|
nvidia,num-lanes = <2>;
|
|
|
|
};
|
|
|
|
};
|
|
|
|
|
|
|
|
|
|
|
|
Board DTS:
|
|
|
|
|
|
|
|
pcie-controller {
|
|
|
|
status = "okay";
|
|
|
|
|
|
|
|
vdd-supply = <&pci_vdd_reg>;
|
|
|
|
pex-clk-supply = <&pci_clk_reg>;
|
|
|
|
|
|
|
|
/* root port 00:01.0 */
|
|
|
|
pci@1,0 {
|
|
|
|
status = "okay";
|
|
|
|
|
|
|
|
/* bridge 01:00.0 (optional) */
|
|
|
|
pci@0,0 {
|
|
|
|
reg = <0x010000 0 0 0 0>;
|
|
|
|
|
|
|
|
#address-cells = <3>;
|
|
|
|
#size-cells = <2>;
|
|
|
|
|
|
|
|
device_type = "pci";
|
|
|
|
|
|
|
|
/* endpoint 02:00.0 */
|
|
|
|
pci@0,0 {
|
|
|
|
reg = <0x020000 0 0 0 0>;
|
|
|
|
};
|
|
|
|
};
|
|
|
|
};
|
|
|
|
};
|
|
|
|
|
|
|
|
Note that devices on the PCI bus are dynamically discovered using PCI's bus
|
|
|
|
enumeration and therefore don't need corresponding device nodes in DT. However
|
|
|
|
if a device on the PCI bus provides a non-probeable bus such as I2C or SPI,
|
|
|
|
device nodes need to be added in order to allow the bus' children to be
|
|
|
|
instantiated at the proper location in the operating system's device tree (as
|
|
|
|
illustrated by the optional nodes in the example above).
|