mirror of
https://github.com/torvalds/linux.git
synced 2024-12-20 18:11:47 +00:00
504 lines
10 KiB
C
504 lines
10 KiB
C
|
/*
|
||
|
* Interface for Dynamic Logical Partitioning of I/O Slots on
|
||
|
* RPA-compliant PPC64 platform.
|
||
|
*
|
||
|
* John Rose <johnrose@austin.ibm.com>
|
||
|
* Linda Xie <lxie@us.ibm.com>
|
||
|
*
|
||
|
* October 2003
|
||
|
*
|
||
|
* Copyright (C) 2003 IBM.
|
||
|
*
|
||
|
* This program is free software; you can redistribute it and/or
|
||
|
* modify it under the terms of the GNU General Public License
|
||
|
* as published by the Free Software Foundation; either version
|
||
|
* 2 of the License, or (at your option) any later version.
|
||
|
*/
|
||
|
#include <linux/init.h>
|
||
|
#include <linux/pci.h>
|
||
|
#include <asm/pci-bridge.h>
|
||
|
#include <asm/semaphore.h>
|
||
|
#include <asm/rtas.h>
|
||
|
#include "../pci.h"
|
||
|
#include "rpaphp.h"
|
||
|
#include "rpadlpar.h"
|
||
|
|
||
|
static DECLARE_MUTEX(rpadlpar_sem);
|
||
|
|
||
|
#define NODE_TYPE_VIO 1
|
||
|
#define NODE_TYPE_SLOT 2
|
||
|
#define NODE_TYPE_PHB 3
|
||
|
|
||
|
static struct device_node *find_php_slot_vio_node(char *drc_name)
|
||
|
{
|
||
|
struct device_node *child;
|
||
|
struct device_node *parent = of_find_node_by_name(NULL, "vdevice");
|
||
|
char *loc_code;
|
||
|
|
||
|
if (!parent)
|
||
|
return NULL;
|
||
|
|
||
|
for (child = of_get_next_child(parent, NULL);
|
||
|
child; child = of_get_next_child(parent, child)) {
|
||
|
loc_code = get_property(child, "ibm,loc-code", NULL);
|
||
|
if (loc_code && !strncmp(loc_code, drc_name, strlen(drc_name)))
|
||
|
return child;
|
||
|
}
|
||
|
|
||
|
return NULL;
|
||
|
}
|
||
|
|
||
|
/* Find dlpar-capable pci node that contains the specified name and type */
|
||
|
static struct device_node *find_php_slot_pci_node(char *drc_name,
|
||
|
char *drc_type)
|
||
|
{
|
||
|
struct device_node *np = NULL;
|
||
|
char *name;
|
||
|
char *type;
|
||
|
int rc;
|
||
|
|
||
|
while ((np = of_find_node_by_type(np, "pci"))) {
|
||
|
rc = rpaphp_get_drc_props(np, NULL, &name, &type, NULL);
|
||
|
if (rc == 0)
|
||
|
if (!strcmp(drc_name, name) && !strcmp(drc_type, type))
|
||
|
break;
|
||
|
}
|
||
|
|
||
|
return np;
|
||
|
}
|
||
|
|
||
|
static struct device_node *find_newly_added_node(char *drc_name, int *node_type)
|
||
|
{
|
||
|
struct device_node *dn;
|
||
|
|
||
|
dn = find_php_slot_pci_node(drc_name, "SLOT");
|
||
|
if (dn) {
|
||
|
*node_type = NODE_TYPE_SLOT;
|
||
|
return dn;
|
||
|
}
|
||
|
|
||
|
dn = find_php_slot_pci_node(drc_name, "PHB");
|
||
|
if (dn) {
|
||
|
*node_type = NODE_TYPE_PHB;
|
||
|
return dn;
|
||
|
}
|
||
|
|
||
|
dn = find_php_slot_vio_node(drc_name);
|
||
|
if (dn) {
|
||
|
*node_type = NODE_TYPE_VIO;
|
||
|
return dn;
|
||
|
}
|
||
|
|
||
|
return NULL;
|
||
|
}
|
||
|
|
||
|
static struct slot *find_slot(char *drc_name)
|
||
|
{
|
||
|
struct list_head *tmp, *n;
|
||
|
struct slot *slot;
|
||
|
|
||
|
list_for_each_safe(tmp, n, &rpaphp_slot_head) {
|
||
|
slot = list_entry(tmp, struct slot, rpaphp_slot_list);
|
||
|
if (strcmp(slot->location, drc_name) == 0)
|
||
|
return slot;
|
||
|
}
|
||
|
|
||
|
return NULL;
|
||
|
}
|
||
|
|
||
|
static void rpadlpar_claim_one_bus(struct pci_bus *b)
|
||
|
{
|
||
|
struct list_head *ld;
|
||
|
struct pci_bus *child_bus;
|
||
|
|
||
|
for (ld = b->devices.next; ld != &b->devices; ld = ld->next) {
|
||
|
struct pci_dev *dev = pci_dev_b(ld);
|
||
|
int i;
|
||
|
|
||
|
for (i = 0; i < PCI_NUM_RESOURCES; i++) {
|
||
|
struct resource *r = &dev->resource[i];
|
||
|
|
||
|
if (r->parent || !r->start || !r->flags)
|
||
|
continue;
|
||
|
rpaphp_claim_resource(dev, i);
|
||
|
}
|
||
|
}
|
||
|
|
||
|
list_for_each_entry(child_bus, &b->children, node)
|
||
|
rpadlpar_claim_one_bus(child_bus);
|
||
|
}
|
||
|
|
||
|
static int pci_add_secondary_bus(struct device_node *dn,
|
||
|
struct pci_dev *bridge_dev)
|
||
|
{
|
||
|
struct pci_controller *hose = dn->phb;
|
||
|
struct pci_bus *child;
|
||
|
u8 sec_busno;
|
||
|
|
||
|
/* Get busno of downstream bus */
|
||
|
pci_read_config_byte(bridge_dev, PCI_SECONDARY_BUS, &sec_busno);
|
||
|
|
||
|
/* Allocate and add to children of bridge_dev->bus */
|
||
|
child = pci_add_new_bus(bridge_dev->bus, bridge_dev, sec_busno);
|
||
|
if (!child) {
|
||
|
printk(KERN_ERR "%s: could not add secondary bus\n", __FUNCTION__);
|
||
|
return -ENOMEM;
|
||
|
}
|
||
|
|
||
|
sprintf(child->name, "PCI Bus #%02x", child->number);
|
||
|
|
||
|
/* Fixup subordinate bridge bases and resources */
|
||
|
pcibios_fixup_bus(child);
|
||
|
|
||
|
/* Claim new bus resources */
|
||
|
rpadlpar_claim_one_bus(bridge_dev->bus);
|
||
|
|
||
|
if (hose->last_busno < child->number)
|
||
|
hose->last_busno = child->number;
|
||
|
|
||
|
dn->bussubno = child->number;
|
||
|
|
||
|
/* ioremap() for child bus, which may or may not succeed */
|
||
|
remap_bus_range(child);
|
||
|
|
||
|
return 0;
|
||
|
}
|
||
|
|
||
|
static struct pci_dev *dlpar_pci_add_bus(struct device_node *dn)
|
||
|
{
|
||
|
struct pci_controller *hose = dn->phb;
|
||
|
struct pci_dev *dev = NULL;
|
||
|
|
||
|
/* Scan phb bus for EADS device, adding new one to bus->devices */
|
||
|
if (!pci_scan_single_device(hose->bus, dn->devfn)) {
|
||
|
printk(KERN_ERR "%s: found no device on bus\n", __FUNCTION__);
|
||
|
return NULL;
|
||
|
}
|
||
|
|
||
|
/* Add new devices to global lists. Register in proc, sysfs. */
|
||
|
pci_bus_add_devices(hose->bus);
|
||
|
|
||
|
/* Confirm new bridge dev was created */
|
||
|
dev = rpaphp_find_pci_dev(dn);
|
||
|
if (!dev) {
|
||
|
printk(KERN_ERR "%s: failed to add pci device\n", __FUNCTION__);
|
||
|
return NULL;
|
||
|
}
|
||
|
|
||
|
if (dev->hdr_type != PCI_HEADER_TYPE_BRIDGE) {
|
||
|
printk(KERN_ERR "%s: unexpected header type %d\n",
|
||
|
__FUNCTION__, dev->hdr_type);
|
||
|
return NULL;
|
||
|
}
|
||
|
|
||
|
if (pci_add_secondary_bus(dn, dev))
|
||
|
return NULL;
|
||
|
|
||
|
return dev;
|
||
|
}
|
||
|
|
||
|
static int dlpar_pci_remove_bus(struct pci_dev *bridge_dev)
|
||
|
{
|
||
|
struct pci_bus *secondary_bus;
|
||
|
|
||
|
if (!bridge_dev) {
|
||
|
printk(KERN_ERR "%s: unexpected null device\n",
|
||
|
__FUNCTION__);
|
||
|
return -EINVAL;
|
||
|
}
|
||
|
|
||
|
secondary_bus = bridge_dev->subordinate;
|
||
|
|
||
|
if (unmap_bus_range(secondary_bus)) {
|
||
|
printk(KERN_ERR "%s: failed to unmap bus range\n",
|
||
|
__FUNCTION__);
|
||
|
return -ERANGE;
|
||
|
}
|
||
|
|
||
|
pci_remove_bus_device(bridge_dev);
|
||
|
return 0;
|
||
|
}
|
||
|
|
||
|
static inline int dlpar_add_pci_slot(char *drc_name, struct device_node *dn)
|
||
|
{
|
||
|
struct pci_dev *dev;
|
||
|
|
||
|
/* Add pci bus */
|
||
|
dev = dlpar_pci_add_bus(dn);
|
||
|
if (!dev) {
|
||
|
printk(KERN_ERR "%s: unable to add bus %s\n", __FUNCTION__,
|
||
|
drc_name);
|
||
|
return -EIO;
|
||
|
}
|
||
|
|
||
|
return 0;
|
||
|
}
|
||
|
|
||
|
static int dlpar_remove_root_bus(struct pci_controller *phb)
|
||
|
{
|
||
|
struct pci_bus *phb_bus;
|
||
|
int rc;
|
||
|
|
||
|
phb_bus = phb->bus;
|
||
|
if (!(list_empty(&phb_bus->children) &&
|
||
|
list_empty(&phb_bus->devices))) {
|
||
|
return -EBUSY;
|
||
|
}
|
||
|
|
||
|
rc = pcibios_remove_root_bus(phb);
|
||
|
if (rc)
|
||
|
return -EIO;
|
||
|
|
||
|
device_unregister(phb_bus->bridge);
|
||
|
pci_remove_bus(phb_bus);
|
||
|
|
||
|
return 0;
|
||
|
}
|
||
|
|
||
|
static int dlpar_remove_phb(struct slot *slot)
|
||
|
{
|
||
|
struct pci_controller *phb;
|
||
|
struct device_node *dn;
|
||
|
int rc = 0;
|
||
|
|
||
|
dn = slot->dn;
|
||
|
if (!dn) {
|
||
|
printk(KERN_ERR "%s: unexpected NULL slot device node\n",
|
||
|
__FUNCTION__);
|
||
|
return -EIO;
|
||
|
}
|
||
|
|
||
|
phb = dn->phb;
|
||
|
if (!phb) {
|
||
|
printk(KERN_ERR "%s: unexpected NULL phb pointer\n",
|
||
|
__FUNCTION__);
|
||
|
return -EIO;
|
||
|
}
|
||
|
|
||
|
if (rpaphp_remove_slot(slot)) {
|
||
|
printk(KERN_ERR "%s: unable to remove hotplug slot %s\n",
|
||
|
__FUNCTION__, slot->location);
|
||
|
return -EIO;
|
||
|
}
|
||
|
|
||
|
rc = dlpar_remove_root_bus(phb);
|
||
|
if (rc < 0)
|
||
|
return rc;
|
||
|
|
||
|
return 0;
|
||
|
}
|
||
|
|
||
|
static int dlpar_add_phb(struct device_node *dn)
|
||
|
{
|
||
|
struct pci_controller *phb;
|
||
|
|
||
|
phb = init_phb_dynamic(dn);
|
||
|
if (!phb)
|
||
|
return -EINVAL;
|
||
|
|
||
|
return 0;
|
||
|
}
|
||
|
|
||
|
/**
|
||
|
* dlpar_add_slot - DLPAR add an I/O Slot
|
||
|
* @drc_name: drc-name of newly added slot
|
||
|
*
|
||
|
* Make the hotplug module and the kernel aware
|
||
|
* of a newly added I/O Slot.
|
||
|
* Return Codes -
|
||
|
* 0 Success
|
||
|
* -ENODEV Not a valid drc_name
|
||
|
* -EINVAL Slot already added
|
||
|
* -ERESTARTSYS Signalled before obtaining lock
|
||
|
* -EIO Internal PCI Error
|
||
|
*/
|
||
|
int dlpar_add_slot(char *drc_name)
|
||
|
{
|
||
|
struct device_node *dn = NULL;
|
||
|
int node_type;
|
||
|
int rc = 0;
|
||
|
|
||
|
if (down_interruptible(&rpadlpar_sem))
|
||
|
return -ERESTARTSYS;
|
||
|
|
||
|
/* Check for existing hotplug slot */
|
||
|
if (find_slot(drc_name)) {
|
||
|
rc = -EINVAL;
|
||
|
goto exit;
|
||
|
}
|
||
|
|
||
|
dn = find_newly_added_node(drc_name, &node_type);
|
||
|
if (!dn) {
|
||
|
rc = -ENODEV;
|
||
|
goto exit;
|
||
|
}
|
||
|
|
||
|
switch (node_type) {
|
||
|
case NODE_TYPE_VIO:
|
||
|
/* Just add hotplug slot */
|
||
|
break;
|
||
|
case NODE_TYPE_SLOT:
|
||
|
rc = dlpar_add_pci_slot(drc_name, dn);
|
||
|
break;
|
||
|
case NODE_TYPE_PHB:
|
||
|
rc = dlpar_add_phb(dn);
|
||
|
break;
|
||
|
default:
|
||
|
printk("%s: unexpected node type\n", __FUNCTION__);
|
||
|
return -EIO;
|
||
|
}
|
||
|
|
||
|
if (!rc && rpaphp_add_slot(dn)) {
|
||
|
printk(KERN_ERR "%s: unable to add hotplug slot %s\n",
|
||
|
__FUNCTION__, drc_name);
|
||
|
rc = -EIO;
|
||
|
}
|
||
|
exit:
|
||
|
up(&rpadlpar_sem);
|
||
|
return rc;
|
||
|
}
|
||
|
|
||
|
/**
|
||
|
* dlpar_remove_vio_slot - DLPAR remove a virtual I/O Slot
|
||
|
* @drc_name: drc-name of newly added slot
|
||
|
*
|
||
|
* Remove the kernel and hotplug representations
|
||
|
* of an I/O Slot.
|
||
|
* Return Codes:
|
||
|
* 0 Success
|
||
|
* -EIO Internal Error
|
||
|
*/
|
||
|
int dlpar_remove_vio_slot(struct slot *slot, char *drc_name)
|
||
|
{
|
||
|
/* Remove hotplug slot */
|
||
|
|
||
|
if (rpaphp_remove_slot(slot)) {
|
||
|
printk(KERN_ERR "%s: unable to remove hotplug slot %s\n",
|
||
|
__FUNCTION__, drc_name);
|
||
|
return -EIO;
|
||
|
}
|
||
|
return 0;
|
||
|
}
|
||
|
|
||
|
/**
|
||
|
* dlpar_remove_slot - DLPAR remove a PCI I/O Slot
|
||
|
* @drc_name: drc-name of newly added slot
|
||
|
*
|
||
|
* Remove the kernel and hotplug representations
|
||
|
* of a PCI I/O Slot.
|
||
|
* Return Codes:
|
||
|
* 0 Success
|
||
|
* -ENODEV Not a valid drc_name
|
||
|
* -EIO Internal PCI Error
|
||
|
*/
|
||
|
int dlpar_remove_pci_slot(struct slot *slot, char *drc_name)
|
||
|
{
|
||
|
struct pci_dev *bridge_dev;
|
||
|
|
||
|
bridge_dev = slot->bridge;
|
||
|
if (!bridge_dev) {
|
||
|
printk(KERN_ERR "%s: unexpected null bridge device\n",
|
||
|
__FUNCTION__);
|
||
|
return -EIO;
|
||
|
}
|
||
|
|
||
|
/* Remove hotplug slot */
|
||
|
if (rpaphp_remove_slot(slot)) {
|
||
|
printk(KERN_ERR "%s: unable to remove hotplug slot %s\n",
|
||
|
__FUNCTION__, drc_name);
|
||
|
return -EIO;
|
||
|
}
|
||
|
|
||
|
/* Remove pci bus */
|
||
|
|
||
|
if (dlpar_pci_remove_bus(bridge_dev)) {
|
||
|
printk(KERN_ERR "%s: unable to remove pci bus %s\n",
|
||
|
__FUNCTION__, drc_name);
|
||
|
return -EIO;
|
||
|
}
|
||
|
return 0;
|
||
|
}
|
||
|
|
||
|
/**
|
||
|
* dlpar_remove_slot - DLPAR remove an I/O Slot
|
||
|
* @drc_name: drc-name of newly added slot
|
||
|
*
|
||
|
* Remove the kernel and hotplug representations
|
||
|
* of an I/O Slot.
|
||
|
* Return Codes:
|
||
|
* 0 Success
|
||
|
* -ENODEV Not a valid drc_name
|
||
|
* -EINVAL Slot already removed
|
||
|
* -ERESTARTSYS Signalled before obtaining lock
|
||
|
* -EIO Internal Error
|
||
|
*/
|
||
|
int dlpar_remove_slot(char *drc_name)
|
||
|
{
|
||
|
struct slot *slot;
|
||
|
int rc = 0;
|
||
|
|
||
|
if (down_interruptible(&rpadlpar_sem))
|
||
|
return -ERESTARTSYS;
|
||
|
|
||
|
if (!find_php_slot_vio_node(drc_name) &&
|
||
|
!find_php_slot_pci_node(drc_name, "SLOT") &&
|
||
|
!find_php_slot_pci_node(drc_name, "PHB")) {
|
||
|
rc = -ENODEV;
|
||
|
goto exit;
|
||
|
}
|
||
|
|
||
|
slot = find_slot(drc_name);
|
||
|
if (!slot) {
|
||
|
rc = -EINVAL;
|
||
|
goto exit;
|
||
|
}
|
||
|
|
||
|
if (slot->type == PHB) {
|
||
|
rc = dlpar_remove_phb(slot);
|
||
|
} else {
|
||
|
switch (slot->dev_type) {
|
||
|
case PCI_DEV:
|
||
|
rc = dlpar_remove_pci_slot(slot, drc_name);
|
||
|
break;
|
||
|
|
||
|
case VIO_DEV:
|
||
|
rc = dlpar_remove_vio_slot(slot, drc_name);
|
||
|
break;
|
||
|
}
|
||
|
}
|
||
|
exit:
|
||
|
up(&rpadlpar_sem);
|
||
|
return rc;
|
||
|
}
|
||
|
|
||
|
static inline int is_dlpar_capable(void)
|
||
|
{
|
||
|
int rc = rtas_token("ibm,configure-connector");
|
||
|
|
||
|
return (int) (rc != RTAS_UNKNOWN_SERVICE);
|
||
|
}
|
||
|
|
||
|
int __init rpadlpar_io_init(void)
|
||
|
{
|
||
|
int rc = 0;
|
||
|
|
||
|
if (!is_dlpar_capable()) {
|
||
|
printk(KERN_WARNING "%s: partition not DLPAR capable\n",
|
||
|
__FUNCTION__);
|
||
|
return -EPERM;
|
||
|
}
|
||
|
|
||
|
rc = dlpar_sysfs_init();
|
||
|
return rc;
|
||
|
}
|
||
|
|
||
|
void rpadlpar_io_exit(void)
|
||
|
{
|
||
|
dlpar_sysfs_exit();
|
||
|
return;
|
||
|
}
|
||
|
|
||
|
module_init(rpadlpar_io_init);
|
||
|
module_exit(rpadlpar_io_exit);
|
||
|
MODULE_LICENSE("GPL");
|